1. Sensitivity Label: General
Escondida Autonomy Program
Minera Escondida - Autonomous Trucks
Taller de entrenamiento proyecto
New Wireless Services (NWS).
JUNIO 2024
7. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
General Requirements Specific Project Data
Product Type Airscale eNB
Frequency Band B40 2300 MHZ
Duplex Mode TDD
Bandwidth (Mhz) 20 MHz
Antenna Scheme 2x2 or 4X4 MIMO (site dependent)
Radio Module AZNA
Atoll compatible Terrain Data Yes
Coverage Areas, Polygon Provided by BHP
UL Throughput@Cell EDGE 3 Mbps on Surface zones and 10 Mbps on pit/drill zones
General Requirements Specific Project Data
Product Type Airscale eNB
Frequency Band B28 700 MHZ
Duplex Mode FDD
Bandwidth (Mhz) 5 MHz
Antenna Scheme 2x2 or 4X4 MIMO (site dependent)
Radio Module AHPE
Atoll compatible Terrain Data Yes
Coverage Areas, Polygon Provided by BHP
UL Throughput@Cell EDGE 3 Mbps on Surface zones
2 link budgets were defined based on the following cell edge requirements:
Pits: DL/UL Throughput >= 10Mbps (-97.5 dBm)
o This requirement will help to assure the operation mainly for the autonomous drills, that have the higher throughput requirements (about 6Mbps)
Surfaces: DL/UL Throughput >= 3Mbps (-101.6 dBm)
The objective of the link budget is to estimate the maximum losses allowed in a radio link to achieve the minimum service defined at the cell edge.
In the surfaces the throughout target is lower than the pit because the applications that runs in these zones have a lower throughput requirement.
Link Budget and RF Equipment
8. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
23 eNB RF y 5 Site de MMOO:
6 Existing sites are re-used:
o 2 existing HD 1.0 sites B28/B40 (existing eNBs)
o 1 existing HD 1.0 site B7/B40 (existing eNB)
o 3 existing light Cows V2.0 NOKIA (1-2 Sectors 10 meters) B40.
11 totally new Sites.
o 5 light Cows V3.0 NOKIA (1-2 Sectors 12 meters), B40
o 6 HD Cows V2 (3 Sectors 20 meters), B40
6 Existing structures will be used:
o 4 new dual band B28/B40 will be mounted on existing towers
o 2 sites B40 will be on a tower
5 MMOO site on the top of building
Final Name+HA1:H29Tipo COW Alt [m] Final Config Ubicacion
ESCRLLTE35 LT 2.0 10 2300/2600 MEL RAJO SUR
ESCRLLTE34 LT 2.0 10 2300/2600 MEL RAJO SUR
ESCRLLTE33 LT 2.0 10 2300/2600 MEL RAJO SUR
ESCRHLTE32 HD 2.0 20 2300/2600 MEL RAJO SUR
ESCRHLTE07 HD 1.0 27 2300/700 Botadero N17
ESCRHLTE06 HD 1.0 27 2300/700 MEL RAJO SUR
ESCRBLTE05 Torre 30 2300/700 MEL RAJO SUR
ESCPLL127 LT 3.0 12 2300/2600 MEL RAJO SUR
ESCPLL126 LT 3.0 12 2300/2600 MEL RAJO SUR
ESCPLL125 LT 3.0 12 2300/2600 MEL RAJO SUR
ESCPLL120 LT 3.0 12 2300 OLAP
ESCPLL119 LT 3.0 12 2300 Chancador 4
ESCPHL118 HD 3.0 20 2300/2600 MEL RAJO SUR PL1
ESCPHL115 HD 3.0 12 2300 Comedor 3262
ESCPHL114 HD 3.0 20 2300/2600 Rajo Sur N17
ESCPFL123 Fast Site 2.0 20 2300/700 Tailing Danm
ESCPFL122 Fast Site 3.0 20 2300 Coloso
ESCPFL117 Fast Site 3.0 20 2300 Cancha de entrenamiento
ESCPFL116 Fast Site 3.0 20 2300 Patio de Cable Rajo Sur
ESCPBL18 Torre 18 2300/700 Cerro 2000
ESCPBL17 Torre 18 2300/700 VSL
ESCPBL132 Poste 10 MW Coloso
ESCPBL124 Torre 18 2300/700 Campamento 7000
ESCPBL121 Torre 22 2300 GGOM
ESCPAL134 Laguna Seca 4 Data Center Sala ER500
ESCPAL131 Nave Taller 793 27 MW Zona Los Colorados
ESCPAL130 Nave Taller 797 27 MW Zona Los Colorados
ESCPAL129 Nave Los Colorados 27 MW Los Colorados
ESCPAL128 Nave Laguna Seca 27 MW Laguna Seca
Site Distribution
10. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
16 sites will be inside de pit polygon.
o 5 New HD cows V2.0 B40
o 5 New Light cows V3.0 B40
o 2 existing Light cows V2.0 B40
o 1 existing HD cows V2.0 B7/B40
o 2 existing HD cows V1.0 B28/B40
o 1 B40 site mounted on an existing tower
RSRP South Pit MEL % Focus Zone
RSRP Level (DL) >-97,5 (10mbps@Frame) 51,1
RSRP Level (DL) >-101,6 (3mbps@Frame) 66,2
RSRP Level (DL) >-112,9 94,1
RSRP Level (DL) >-120 98,2
Coverage Prediction B40 Escondida
11. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
RSRP South Zone MEL % Focus Zine
RSRP Level (DL) >-97,5 (10mbps@Frame) 20,8
RSRP Level (DL) >-101,6 (3mbps@Frame) 31,9
RSRP Level (DL) >-112,9 69,2
RSRP Level (DL) >-120 90
6 New sites will be inside the south polygon.
• 4 dual band B28/B40 mounted on a tower.
• 1 FastSite B28/B40 site.
• 1 Light COW V3.0 B40 .
Coverage Prediction B40 South Escondida
12. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
1 new site will be installed on a COW HD
RSRP % Focus Zine
RSRP Level (DL) >-97,5 (10mbps@Frame) 95,5
RSRP Level (DL) >-101,6 (3mbps@Frame) 96,5
RSRP Level (DL) >-112,9 98,9
RSRP Level (DL) >-120 99,6
Coverage Prediction B40 Puerto Coloso
13. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
RSRP % Focus Zine
RSRP Level (DL) >-101,1 (3mbps@Frame) 91,2
4 New sites will be inside the south polygon.
o 3 dual band B28/B40 mounted on a tower.
o 1 FastSite B28/B40 site.
Coverage Prediction B40 Escondida
14. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
Original Name
Número
MicroCeldas
Tipo Infra Altura [m]
SC1: 12m
SC2: 12m
SC3: 12m
SC4: 12m
SC1: 12m
SC2: 12m
SC3: 12m
SC4: 12m
SC5: 12m
SC1: 12m
SC2: 12m
SC3: 12m
SC4: 12m
SC1:12m
SC2: 12m
SC3: 12m
SC4: 12m
SC1: 12m
SC2: 12m
Linea 1 4 Flexi Zone Micro FWND
OGP1 5 Flexi Zone Micro FWND
TruckShop Taller 793 2 Flexi Zone Micro FWND
Los Colorados 4 Flezi Zone Micro FWND
TruckShop Taller 797 4 Flezi Zone Micro FWND
Proyecto indoor en edificio industriales:
• Laguna Seca – 9 Smallcells
• Los Colorados – 4 Smallcells
• Truckshop Taller 797 - 4 Smallcells
• Truckshop Taller 793 - 2 SmallCells
Indoor Projects
15. Sensitivity Label: General
Red de acceso de radio | Proyecto NWS
Capacity Simulation (11 drills, 4 precut drills and scaling factor 1)
17. Sensitivity Label: General
17
Red de transportes MMOO | Proyecto NWS
Equipos de MMOO utilizados: Nokia Wavence
UBT-T
UBT-T is a “dual arrier in a box” configuration supporting traditional multiple microwave frequencies up to 42 GHz. Using the most
advanced radio technologies, UBT-T provides multi-gigabit capacity and low latency transport with best-in-class transmitted power,
which can manage the following operating modes as:
•Full Outdoor (for native Ethernet applications)
•Split-Mount in conjunction with MSS Box
UBT-T supports the following functionalities:
Capacity: 4 x E1 to 255 x E1 with single transceiver, 8 x E1 to
510 x E1 with dual transceiver
High performance dual carrier radio unit in one box
Frequencies: 6-42 GHz
Modulation: up to 4096 QAM
Channel size: up to 2 x 112 MHz (ETSI)
Throughput: 2.5 Gbps (1.3 Gbps per channel)
Latency: down to 100 μs
XPIC and High PTx
Embedded Radio LAG
Packet throughput booster
Y.1731 BNM
Interfaces:
o Electrical 1Gbps (PFoE)
o Optical (SFP)1/2.5/10 Gbps
o Optical (SFP) 1/2.5/10 Gbps/ Coupling/ Management
o DC power (bi-filar or Coaxial)
18. Sensitivity Label: General
Red de transportes MMOO | Proyecto NWS
Equipos de MMOO utilizados: Nokia Wavence
UBT-T hardware is divided into two parts:
•Wide Band Active Part (Radio + digital)
•Antenna Interface Module (AIM) Passive Part
Wavence UBT-T implements an innovative product design, with hardware split between the active wideband radio part and the Antenna Interface Module (AIM), a passive
component interfacing the antenna. Thanks to this innovative design, UBT-T can support channels belonging to different sub-bands on the same box. This offers high flexibility
in deployment options, the configuration specificities being managed inside the AIM, thus simplifying the installation, maintenance and spare part management.
Antenna, AIM-T and UBT-T
19. Sensitivity Label: General
Red de transportes MMOO | Proyecto NWS
Equipos de MMOO utilizados: Nokia Wavence
The Nokia 7250 IXR-e is the interface
between the eNB and UBT-T, the router
interconnect local transport Wavence as
indoor Unit (IDU).
The Nokia 7250 IXR-e platform are
purpose-built for access and aggregation
in mobile anyhaul, fixed-mobile
convergence, and mission-critical
enterprise applications. They offer
compact, temperature-hardened platforms
with advanced timing, security and quality
of service features.
Nokia 7250 IXR-e
Element Ports Specs Power
7250
IXR-e
(small)
14 x SFP+/SFP
10/1GE
4 x RJ-45 100/1000
Mb/s
Height: 1RU,
4.5 cm (1.75
in)
• Depth: 25.4
cm (10.0 in)
• Width: 43.8
cm (17.25 in)
• Rack-
mountable in a
48.2-cm rack,
30-cm depth
(standard 19-in
equip-ment
rack, 12-in
depth)
• ETSI 300 mm
compliant
DC PSU: 250
Watts
Two feeds:
Modular AC and
DC power
supplies
Supports
concurrent use of
AC and DC power
supplies
AC input: 100 V
to 240 V, 50 Hz to
60 Hz
DC input: 20 V to
60 V
Low Voltage DC
with single feed: -
40 V to -72 V
20. Sensitivity Label: General
Red de transportes MMOO | Proyecto NWS
Equipos de MMOO utilizados: Nokia Wavence
Each site being part of a ring topology,
there is two microwave directions, each
connected to a router 7250 IXR-e, as
follows:
Typical Drop/Insert eNB, two MW
directions
Typical Termination Site
21. Sensitivity Label: General
Red de transportes MMOO | Proyecto NWS
Consideraciones de diseño y topología:
The Microwave solution is considering:
MW equipment Wavence UBT-T SA.
2+0 XPIC configuration.
200 Mbps Capacity per channel (Total 400 Mbps).
Frequencies 38, 23 and 15 GHz.
Bandwidth channel 28 MHz.
Antenna diameter 1, 2 and 3Ft.
Ring protection MW links topology.
The MW links unmounted will be used for
reinstalling in the new MW links.
The design contemplates a maximum of 7 nodes
per ring.
The MW link ESCPFL122 - ESCPAL132 don’t
belong to the MW protection ring.
27. Sensitivity Label: General
27
RED METRO | Proyecto NWS
1. Revisar topología red de Transmisión/Red Metro.
2. Revisar equipamiento a instalar/versiones de
Software
3. Topología Final desplegada
4. Ubicación de equipos en Rack/Salas
5. Mostrar pendientes para la energización de
equipos IP de red Metro
28. Sensitivity Label: General
RED DWDM – Base Transporte Red Metro
LEGEND:
ACCESS 200
10 x 10G
1830PSS-16
DWDM
DWDM @
400G
LAGUNA SECA
GOM
C3260
OGP
OXIDO
ER16A VSL
SULFURO
31. Sensitivity Label: General
Proyecto Red Metro – Disposición de equipos:
7210 SAS
7210 SAS
• En cada site se desplegarán:
• 2 * 7750 – SR1
• 2 * 7210 – SAS-Sx
• 2 * Optical Patch Panel
33. Sensitivity Label: General
Topología de integración IP/Backhaul – Red Metro MEL
• Backbone OSPF area 0.0.0.0
• point.-to-point interfaces
• All interfaces with BFD
• Protocols:
• MPLS
• RSVP-TE
• BGP
• LDP
36. Sensitivity Label: General
LAGUNA SECA
Se propone la utilización
de Racks 1 y 7 en las
posiciones de las figuras
Verificaciones a realizar en
levantamientos de infraestructura:
• Revisar y asignar espacios
disponibles en rPDU A y rPDU B.
• Verificar condiciones de
temperatura de la sala y capacidad
de los equipos HVAC.
• Verificar corriente/potencia
disponible en circuitos que alimentan
las rPDU A y B del rack.
• Verificar corriente/potencia
disponible en las UPS A y B.
• Revisar posibles interferencias para
el montaje de los equipos y su
conexionado.
• Verificar reflejos disponibles o
disponibilidad en canalización según
ruta de destino para interconexión
37. Sensitivity Label: General
GOM
Se propone la utilización
de Racks 6 y 1 en las
posiciones de las figuras
Verificaciones a realizar en
levantamientos de infraestructura:
• Revisar y asignar espacios
disponibles en rPDU A y rPDU B.
• Verificar condiciones de
temperatura de la sala y capacidad
de los equipos HVAC.
• Verificar corriente/potencia
disponible en circuitos que alimentan
las rPDU A y B del rack.
• Verificar corriente/potencia
disponible en las UPS A y B.
• Revisar posibles interferencias para
el montaje de los equipos y su
conexionado.
• Verificar reflejos disponibles o
disponibilidad en canalización según
ruta de destino para interconexión
38. Sensitivity Label: General
ER16-A
Se propone la utilización
de Racks 2 y 3 en las
posiciones de las figuras
Verificaciones a realizar en
levantamientos de infraestructura:
• Revisar y asignar espacios
disponibles en rPDU A y rPDU B.
• Verificar condiciones de
temperatura de la sala y capacidad
de los equipos HVAC.
• Verificar corriente/potencia
disponible en circuitos que alimentan
las rPDU A y B del rack.
• Verificar corriente/potencia
disponible en las UPS A y B.
• Revisar posibles interferencias para
el montaje de los equipos y su
conexionado.
• Verificar reflejos disponibles o
disponibilidad en canalización según
ruta de destino para interconexión
39. Sensitivity Label: General
OXIDO
Se propone la utilización
de Racks 6 y 11 en las
posiciones de las figuras
Verificaciones a realizar en
levantamientos de infraestructura:
• Revisar y asignar espacios
disponibles en rPDU A y rPDU B.
• Verificar condiciones de
temperatura de la sala y capacidad
de los equipos HVAC.
• Verificar corriente/potencia
disponible en circuitos que alimentan
las rPDU A y B del rack.
• Verificar corriente/potencia
disponible en las UPS A y B.
• Revisar posibles interferencias para
el montaje de los equipos y su
conexionado.
• Verificar reflejos disponibles o
disponibilidad en canalización según
ruta de destino para interconexión
40. Sensitivity Label: General
SULFURO
Se propone la utilización
de Racks 1 y 3 en las
posiciones de las figuras
Verificaciones a realizar en
levantamientos de infraestructura:
• Revisar y asignar espacios
disponibles en rPDU A y rPDU B.
• Verificar condiciones de
temperatura de la sala y capacidad
de los equipos HVAC.
• Verificar corriente/potencia
disponible en circuitos que alimentan
las rPDU A y B del rack.
• Verificar corriente/potencia
disponible en las UPS A y B.
• Revisar posibles interferencias para
el montaje de los equipos y su
conexionado.
• Verificar reflejos disponibles o
disponibilidad en canalización según
ruta de destino para interconexión
41. Sensitivity Label: General
VSL
- No se cuenta con autorización para la instalación de equipos
debido a problemas de energía/clima en Sala
- Se ha propuesto la instalación futura de este equipamiento en
nuevo contenedor de VSL (Autonomy)
42. Sensitivity Label: General
Documentación
- HLD/LLD Nokia Aprobado por Ingeniería y Operaciones
- BHP MEL – Metro HLD – v1.4
- BHP MEL – Metro LLD – v1.3
- LLD BHP (en revisión)
- Technology Detailed Design Template TDT00002_Metro
Network_v1.0
Minerals America Autonomy - 3.5.1.1.3 Red Metro - All Documents
(bhpbilliton.com)