8K Isp Flash Mcu Family: Sar Adc
8K Isp Flash Mcu Family: Sar Adc
C8051F020/1/2/3
Preliminary Rev. 1.4 12/03 Copyright 2003 by Silicon Laboratories C8051F020/1/2/3-DS14
This information applies to a product under development. Its characteristics and specifications are subject to change without notice.
ANALOG PERIPHERALS
- SAR ADC
12-Bit (C8051F020/1)
10-Bit (C8051F022/3)
1 LSB INL
Programmable Throughput up to 100 ksps
Up to 8 External Inputs; Programmable as Single-Ended or
Differential
Programmable Amplifier Gain: 16, 8, 4, 2, 1, 0.5
Data-Dependent Windowed Interrupt Generator
Built-in Temperature Sensor ( 3C)
- 8-bit ADC
Programmable Throughput up to 500 ksps
8 External Inputs
Programmable Amplifier Gain: 4, 2, 1, 0.5
- Two 12-bit DACs
Can Synchronize Outputs to Timers for Jitter-Free Wave-
form Generation
- Two Analog Comparators
- Voltage Reference
- Precision VDD Monitor/Brown-Out Detector
ON-CHIP JTAG DEBUG & BOUNDARY SCAN
- On-Chip Debug Circuitry Facilitates Full- Speed, Non-
Intrusive In-Circuit/In-System Debugging
- Provides Breakpoints, Single-Stepping, Watchpoints,
Stack Monitor; Inspect/Modify Memory and Registers
- Superior Performance to Emulation Systems Using ICE-
Chips, Target Pods, and Sockets
- IEEE1149.1 Compliant Boundary Scan
- Low-Cost, Complete Development Kit
HIGH SPEED 8051 C CORE
- Pipelined Instruction Architecture; Executes 70% of
Instruction Set in 1 or 2 System Clocks
- Up to 25 MIPS Throughput with 25 MHz Clock
- 22 Vectored Interrupt Sources
MEMORY
- 4352 Bytes Internal Data RAM (4k + 256)
- 64k Bytes FLASH; In-System programmable in 512-byte
Sectors
- External 64k Byte Data Memory Interface (programma-
ble multiplexed or non-multiplexed modes)
DIGITAL PERIPHERALS
- 8 Byte-Wide Port I/O (C8051F020/2); 5V tolerant
- 4 Byte-Wide Port I/O (C8051F021/3); 5V tolerant
- Hardware SMBus (I
2
C Compatible), SPI, and
Two UART Serial Ports Available Concurrently
- Programmable 16-bit Counter/Timer Array with
5 Capture/Compare Modules
- 5 General Purpose 16-bit Counter/Timers
- Dedicated Watch-Dog Timer; Bi-directional Reset Pin
CLOCK SOURCES
- Internal Programmable Oscillator: 2-to-16 MHz
- External Oscillator: Crystal, RC, C, or Clock
- Real-Time Clock Mode using Timer 3 or PCA
SUPPLY VOLTAGE .......................... 2.7V TO 3.6V
- Typical Operating Current: 10 mA @ 20 MHz
- Multiple Power Saving Sleep and Shutdown Modes
100-Pin TQFP and 64-Pin TQFP Packages Available
Temperature Range: -40C to +85C
JTAG
64KB
ISP FLASH
4352 B
SRAM
SANITY
CONTROL
+
-
10/12-bit
100ksps
ADC
CLOCK
CIRCUIT
PGA
VREF
12-Bit
DAC
TEMP
SENSOR
VOLTAGE
COMPARATORS
ANALOG PERIPHERALS
Port 0
Port 1
Port 2
Port 3
C
R
O
S
S
B
A
R
DIGITAL I/O
HIGH-SPEED CONTROLLER CORE
DEBUG
CIRCUITRY
22
INTERRUPTS
8051 CPU
(25MIPS)
12-Bit
DAC
+
-
8-bit
500ksps
ADC
Port 4
Port 5
Port 6
Port 7
E
x
t
e
r
n
a
l
M
e
m
o
r
y
I
n
t
e
r
f
a
c
e
100 pin 64 pin
PGA
UART0
SMBus
SPI Bus
PCA
Timer 0
Timer 1
Timer 2
Timer 3
Timer 4
UART1
A
M
U
X
A
M
U
X
C8051F020/1/2/3
2 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 3
TABLE OF CONTENTS
1. SYSTEM OVERVIEW.........................................................................................................17
1.1. CIP-51 Microcontroller Core ......................................................................................22
1.1.1. Fully 8051 Compatible ..........................................................................................22
1.1.2. Improved Throughput ............................................................................................22
1.1.3. Additional Features................................................................................................23
1.2. On-Chip Memory ............................................................................................................24
1.3. JTAG Debug and Boundary Scan ...................................................................................25
1.4. Programmable Digital I/O and Crossbar .........................................................................26
1.5. Programmable Counter Array .........................................................................................27
1.6. Serial Ports.......................................................................................................................27
1.7. 12-Bit Analog to Digital Converter.................................................................................28
1.8. 8-Bit Analog to Digital Converter...................................................................................29
1.9. Comparators and DACs...................................................................................................30
2. ABSOLUTE MAXIMUM RATINGS..................................................................................31
3. GLOBAL DC ELECTRICAL CHARACTERISTICS ......................................................32
4. PINOUT AND PACKAGE DEFINITIONS........................................................................33
5. ADC0 (12-BIT ADC, C8051F020/1 ONLY) ........................................................................43
5.1. Analog Multiplexer and PGA..........................................................................................43
5.2. ADC Modes of Operation ...............................................................................................44
5.2.1. Starting a Conversion.............................................................................................44
5.2.2. Tracking Modes .....................................................................................................45
5.2.3. Settling Time Requirements ..................................................................................46
5.3. ADC0 Programmable Window Detector.........................................................................53
6. ADC0 (10-BIT ADC, C8051F022/3 ONLY) ........................................................................59
6.1. Analog Multiplexer and PGA..........................................................................................59
6.2. ADC Modes of Operation ...............................................................................................60
6.2.1. Starting a Conversion.............................................................................................60
6.2.2. Tracking Modes .....................................................................................................61
6.2.3. Settling Time Requirements ..................................................................................62
6.3. ADC0 Programmable Window Detector.........................................................................69
7. ADC1 (8-BIT ADC) ...............................................................................................................75
7.1. Analog Multiplexer and PGA..........................................................................................75
7.2. ADC1 Modes of Operation .............................................................................................76
7.2.1. Starting a Conversion.............................................................................................76
7.2.2. Tracking Modes .....................................................................................................76
7.2.3. Settling Time Requirements ..................................................................................78
8. DACS, 12-BIT VOLTAGE MODE......................................................................................83
8.1. DAC Output Scheduling..................................................................................................83
8.1.1. Update Output On-Demand...................................................................................84
8.1.2. Update Output Based on Timer Overflow.............................................................84
8.2. DAC Output Scaling/Justification...................................................................................84
9. VOLTAGE REFERENCE (C8051F020/2)..........................................................................91
C8051F020/1/2/3
4 Rev. 1.4
10. VOLTAGE REFERENCE (C8051F021/3)..........................................................................93
11. COMPARATORS..................................................................................................................95
12. CIP-51 MICROCONTROLLER........................................................................................101
12.1. Instruction Set................................................................................................................102
12.1.1. Instruction and CPU Timing................................................................................102
12.1.2. MOVX Instruction and Program Memory...........................................................102
12.2. Memory Organization ...................................................................................................107
12.2.1. Program Memory.................................................................................................107
12.2.2. Data Memory .......................................................................................................108
12.2.3. General Purpose Registers ...................................................................................108
12.2.4. Bit Addressable Locations ...................................................................................108
12.2.5. Stack .................................................................................................................108
12.2.6. Special Function Registers...................................................................................109
12.2.7. Register Descriptions...........................................................................................113
12.3. Interrupt Handler ...........................................................................................................116
12.3.1. MCU Interrupt Sources and Vectors ...................................................................116
12.3.2. External Interrupts ...............................................................................................116
12.3.3. Interrupt Priorities................................................................................................118
12.3.4. Interrupt Latency..................................................................................................118
12.3.5. Interrupt Register Descriptions............................................................................119
12.4. Power Management Modes ...........................................................................................125
12.4.1. Idle Mode.............................................................................................................125
12.4.2. Stop Mode............................................................................................................125
13. RESET SOURCES ..............................................................................................................127
13.1. Power-on Reset..............................................................................................................128
13.2. Power-fail Reset ............................................................................................................128
13.3. External Reset................................................................................................................129
13.4. Software Forced Reset...................................................................................................129
13.5. Missing Clock Detector Reset .......................................................................................129
13.6. Comparator0 Reset ........................................................................................................129
13.7. External CNVSTR Pin Reset.........................................................................................129
13.8. Watchdog Timer Reset ..................................................................................................129
13.8.1. Enable/Reset WDT ..............................................................................................130
13.8.2. Disable WDT.......................................................................................................130
13.8.3. Disable WDT Lockout.........................................................................................130
13.8.4. Setting WDT Interval...........................................................................................130
14. OSCILLATORS...................................................................................................................135
14.1. External Crystal Example..............................................................................................138
14.2. External RC Example....................................................................................................138
14.3. External Capacitor Example..........................................................................................138
15. FLASH MEMORY..............................................................................................................139
15.1. Programming The FLASH Memory .............................................................................139
15.2. Non-volatile Data Storage .............................................................................................140
15.3. Security Options ............................................................................................................140
16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM.......................145
C8051F020/1/2/3
Rev. 1.4 5
16.1. Accessing XRAM..........................................................................................................145
16.1.1. 16-Bit MOVX Example.......................................................................................145
16.1.2. 8-Bit MOVX Example.........................................................................................145
16.2. Configuring the External Memory Interface .................................................................146
16.3. Port Selection and Configuration ..................................................................................146
16.4. Multiplexed and Non-multiplexed Selection.................................................................148
16.4.1. Multiplexed Configuration ..................................................................................148
16.4.2. Non-multiplexed Configuration...........................................................................149
16.5. Memory Mode Selection...............................................................................................150
16.5.1. Internal XRAM Only...........................................................................................150
16.5.2. Split Mode without Bank Select ..........................................................................150
16.5.3. Split Mode with Bank Select ...............................................................................151
16.5.4. External Only.......................................................................................................151
16.6. Timing .......................................................................................................................151
16.6.1. Non-multiplexed Mode........................................................................................153
16.6.1.1. 16-bit MOVX: EMI0CF[4:2] = 101, 110, or 111................................153
16.6.1.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 101 or 111. ...........154
16.6.1.3. 8-bit MOVX with Bank Select: EMI0CF[4:2] = 110. ..............................155
16.6.2. Multiplexed Mode................................................................................................156
16.6.2.1. 16-bit MOVX: EMI0CF[4:2] = 001, 010, or 011................................156
16.6.2.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 001 or 011. ...........157
16.6.2.3. 8-bit MOVX with Bank Select: EMI0CF[4:2] = 010. ..............................158
17. PORT INPUT/OUTPUT.....................................................................................................161
17.1. Ports 0 through 3 and the Priority Crossbar Decoder....................................................163
17.1.1. Crossbar Pin Assignment and Allocation ............................................................163
17.1.2. Configuring the Output Modes of the Port Pins ..................................................164
17.1.3. Configuring Port Pins as Digital Inputs...............................................................165
17.1.4. External Interrupts (IE6 and IE7) ........................................................................165
17.1.5. Weak Pull-ups......................................................................................................165
17.1.6. Configuring Port 1 Pins as Analog Inputs (AIN1.[7:0])......................................165
17.1.7. External Memory Interface Pin Assignments......................................................166
17.1.8. Crossbar Pin Assignment Example......................................................................168
17.2. Ports 4 through 7 (C8051F020/2 only)..........................................................................177
17.2.1. Configuring Ports which are not Pinned Out.......................................................177
17.2.2. Configuring the Output Modes of the Port Pins ..................................................177
17.2.3. Configuring Port Pins as Digital Inputs...............................................................178
17.2.4. Weak Pull-ups......................................................................................................178
17.2.5. External Memory Interface..................................................................................178
18. SYSTEM MANAGEMENT BUS / I2C BUS (SMBUS0) .................................................183
18.1. Supporting Documents ..................................................................................................184
18.2. SMBus Protocol.............................................................................................................185
18.2.1. Arbitration............................................................................................................185
18.2.2. Clock Low Extension...........................................................................................185
18.2.3. SCL Low Timeout ...............................................................................................186
18.2.4. SCL High (SMBus Free) Timeout.......................................................................186
C8051F020/1/2/3
6 Rev. 1.4
18.3. SMBus Transfer Modes.................................................................................................187
18.3.1. Master Transmitter Mode ....................................................................................187
18.3.2. Master Receiver Mode.........................................................................................187
18.3.3. Slave Transmitter Mode.......................................................................................188
18.3.4. Slave Receiver Mode ...........................................................................................188
18.4. SMBus Special Function Registers ...............................................................................189
18.4.1. Control Register ...................................................................................................189
18.4.2. Clock Rate Register .............................................................................................192
18.4.3. Data Register........................................................................................................193
18.4.4. Address Register ..................................................................................................193
18.4.5. Status Register .....................................................................................................194
19. SERIAL PERIPHERAL INTERFACE BUS (SPI0) ........................................................197
19.1. Signal Descriptions........................................................................................................198
19.1.1. Master Out, Slave In (MOSI) ..............................................................................198
19.1.2. Master In, Slave Out (MISO) ..............................................................................198
19.1.3. Serial Clock (SCK) ..............................................................................................198
19.1.4. Slave Select (NSS)...............................................................................................198
19.2. SPI0 Operation ..............................................................................................................199
19.3. Serial Clock Timing ......................................................................................................200
19.4. SPI Special Function Registers .....................................................................................201
20. UART0 ..................................................................................................................................205
20.1. UART0 Operational Modes ..........................................................................................206
20.1.1. Mode 0: Synchronous Mode................................................................................206
20.1.2. Mode 1: 8-Bit UART, Variable Baud Rate .........................................................207
20.1.3. Mode 2: 9-Bit UART, Fixed Baud Rate..............................................................208
20.1.4. Mode 3: 9-Bit UART, Variable Baud Rate .........................................................209
20.2. Multiprocessor Communications...................................................................................210
20.3. Frame and Transmission Error Detection......................................................................211
21. UART1 ..................................................................................................................................215
21.1. UART1 Operational Modes ..........................................................................................216
21.1.1. Mode 0: Synchronous Mode................................................................................216
21.1.2. Mode 1: 8-Bit UART, Variable Baud Rate .........................................................217
21.1.3. Mode 2: 9-Bit UART, Fixed Baud Rate..............................................................218
21.1.4. Mode 3: 9-Bit UART, Variable Baud Rate .........................................................219
21.2. Multiprocessor Communications...................................................................................220
21.3. Frame and Transmission Error Detection......................................................................221
22. TIMERS................................................................................................................................225
22.1. Timer 0 and Timer 1......................................................................................................227
22.1.1. Mode 0: 13-bit Counter/Timer.............................................................................227
22.1.2. Mode 1: 16-bit Counter/Timer.............................................................................228
22.1.3. Mode 2: 8-bit Counter/Timer with Auto-Reload.................................................229
22.1.4. Mode 3: Two 8-bit Counter/Timers (Timer 0 Only) ...........................................230
22.2. Timer 2 .......................................................................................................................234
22.2.1. Mode 0: 16-bit Counter/Timer with Capture.......................................................235
22.2.2. Mode 1: 16-bit Counter/Timer with Auto-Reload...............................................236
C8051F020/1/2/3
Rev. 1.4 7
22.2.3. Mode 2: Baud Rate Generator .............................................................................237
22.3. Timer 3 .......................................................................................................................240
22.4. Timer 4 .......................................................................................................................243
22.4.1. Mode 0: 16-bit Counter/Timer with Capture.......................................................244
22.4.2. Mode 1: 16-bit Counter/Timer with Auto-Reload...............................................245
22.4.3. Mode 2: Baud Rate Generator .............................................................................246
23. PROGRAMMABLE COUNTER ARRAY.......................................................................249
23.1. PCA Counter/Timer.......................................................................................................250
23.2. Capture/Compare Modules............................................................................................252
23.2.1. Edge-triggered Capture Mode .............................................................................253
23.2.2. Software Timer (Compare) Mode........................................................................254
23.2.3. High Speed Output Mode ....................................................................................255
23.2.4. Frequency Output Mode ......................................................................................256
23.2.5. 8-Bit Pulse Width Modulator Mode ....................................................................257
23.2.6. 16-Bit Pulse Width Modulator Mode ..................................................................258
23.3. Register Descriptions for PCA0....................................................................................259
24. JTAG (IEEE 1149.1)............................................................................................................265
24.1. Boundary Scan...............................................................................................................266
24.1.1. EXTEST Instruction ............................................................................................267
24.1.2. SAMPLE Instruction ...........................................................................................267
24.1.3. BYPASS Instruction............................................................................................267
24.1.4. IDCODE Instruction............................................................................................267
24.2. Flash Programming Commands ....................................................................................268
24.3. Debug Support...............................................................................................................271
C8051F020/1/2/3
8 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 9
LIST OF FIGURES AND TABLES
1. SYSTEM OVERVIEW.........................................................................................................17
Table 1.1. Product Selection Guide......................................................................................17
Figure 1.1. C8051F020 Block Diagram.................................................................................18
Figure 1.2. C8051F021 Block Diagram.................................................................................19
Figure 1.3. C8051F022 Block Diagram.................................................................................20
Figure 1.4. C8051F023 Block Diagram.................................................................................21
Figure 1.5. Comparison of Peak MCU Execution Speeds.....................................................22
Figure 1.6. On-Board Clock and Reset ..................................................................................23
Figure 1.7. On-Chip Memory Map........................................................................................24
Figure 1.8. Development/In-System Debug Diagram...........................................................25
Figure 1.9. Digital Crossbar Diagram....................................................................................26
Figure 1.10. PCA Block Diagram............................................................................................27
Figure 1.11. 12-Bit ADC Block Diagram................................................................................28
Figure 1.12. 8-Bit ADC Diagram............................................................................................29
Figure 1.13. Comparator and DAC Diagram...........................................................................30
2. ABSOLUTE MAXIMUM RATINGS..................................................................................31
Table 2.1. Absolute Maximum Ratings*..............................................................................31
3. GLOBAL DC ELECTRICAL CHARACTERISTICS ......................................................32
Table 3.1. Global DC Electrical Characteristics...................................................................32
4. PINOUT AND PACKAGE DEFINITIONS........................................................................33
Table 4.1. Pin Definitions.....................................................................................................33
Figure 4.1. TQFP-100 Pinout Diagram..................................................................................38
Figure 4.2. TQFP-100 Package Drawing...............................................................................39
Figure 4.3. TQFP-64 Pinout Diagram....................................................................................40
Figure 4.4. TQFP-64 Package Drawing.................................................................................41
5. ADC0 (12-BIT ADC, C8051F020/1 ONLY) ........................................................................43
Figure 5.1. 12-Bit ADC0 Functional Block Diagram............................................................43
Figure 5.2. Temperature Sensor Transfer Function...............................................................44
Figure 5.3. 12-Bit ADC Track and Conversion Example Timing.........................................45
Figure 5.4. ADC0 Equivalent Input Circuits .........................................................................46
Figure 5.5. AMX0CF: AMUX0 Configuration Register (C8051F020/1) .............................47
Figure 5.6. AMX0SL: AMUX0 Channel Select Register (C8051F020/1)............................48
Figure 5.7. ADC0CF: ADC0 Configuration Register (C8051F020/1)..................................49
Figure 5.8. ADC0CN: ADC0 Control Register (C8051F020/1) ...........................................50
Figure 5.9. ADC0H: ADC0 Data Word MSB Register (C8051F020/1) ...............................51
Figure 5.10. ADC0L: ADC0 Data Word LSB Register (C8051F020/1).................................51
Figure 5.11. ADC0 Data Word Example (C8051F020/1) .......................................................52
Figure 5.12. ADC0GTH: ADC0 Greater-Than Data High Byte Register (C8051F020/1) .....53
Figure 5.13. ADC0GTL: ADC0 Greater-Than Data Low Byte Register (C8051F020/1) ......53
Figure 5.14. ADC0LTH: ADC0 Less-Than Data High Byte Register (C8051F020/1) ..........53
Figure 5.15. ADC0LTL: ADC0 Less-Than Data Low Byte Register (C8051F020/1) ...........53
Figure 5.16. 12-Bit ADC0 Window Interrupt Example: Right Justified Single-Ended Data .54
C8051F020/1/2/3
10 Rev. 1.4
Figure 5.17. 12-Bit ADC0 Window Interrupt Example: Right Justified Differential Data.....55
Figure 5.18. 12-Bit ADC0 Window Interrupt Example: Left Justified Single-Ended Data....56
Figure 5.19. 12-Bit ADC0 Window Interrupt Example: Left Justified Differential Data.......57
Table 5.1. 12-Bit ADC0 Electrical Characteristics (C8051F020/1).....................................58
6. ADC0 (10-BIT ADC, C8051F022/3 ONLY) ........................................................................59
Figure 6.1. 10-Bit ADC0 Functional Block Diagram............................................................59
Figure 6.2. Temperature Sensor Transfer Function...............................................................60
Figure 6.3. 10-Bit ADC Track and Conversion Example Timing.........................................61
Figure 6.4. ADC0 Equivalent Input Circuits .........................................................................62
Figure 6.5. AMX0CF: AMUX0 Configuration Register (C8051F022/3) .............................63
Figure 6.6. AMX0SL: AMUX0 Channel Select Register (C8051F022/3)............................64
Figure 6.7. ADC0CF: ADC0 Configuration Register (C8051F022/3)..................................65
Figure 6.8. ADC0CN: ADC0 Control Register (C8051F022/3) ...........................................66
Figure 6.9. ADC0H: ADC0 Data Word MSB Register (C8051F022/3) ...............................67
Figure 6.10. ADC0L: ADC0 Data Word LSB Register (C8051F022/3).................................67
Figure 6.11. ADC0 Data Word Example (C8051F022/3) .......................................................68
Figure 6.12. ADC0GTH: ADC0 Greater-Than Data High Byte Register (C8051F022/3) .....69
Figure 6.13. ADC0GTL: ADC0 Greater-Than Data Low Byte Register (C8051F022/3) ......69
Figure 6.14. ADC0LTH: ADC0 Less-Than Data High Byte Register (C8051F022/3) ..........69
Figure 6.15. ADC0LTL: ADC0 Less-Than Data Low Byte Register (C8051F022/3) ...........69
Figure 6.16. 10-Bit ADC0 Window Interrupt Example: Right Justified Single-Ended Data .70
Figure 6.17. 10-Bit ADC0 Window Interrupt Example: Right Justified Differential Data.....71
Figure 6.18. 10-Bit ADC0 Window Interrupt Example: Left Justified Single-Ended Data....72
Figure 6.19. 10-Bit ADC0 Window Interrupt Example: Left Justified Differential Data.......73
Table 6.1. 10-Bit ADC0 Electrical Characteristics (C8051F022/3).....................................74
7. ADC1 (8-BIT ADC) ...............................................................................................................75
Figure 7.1. ADC1 Functional Block Diagram.......................................................................75
Figure 7.2. ADC1 Track and Conversion Example Timing..................................................77
Figure 7.3. ADC1 Equivalent Input Circuit...........................................................................78
Figure 7.4. ADC1CF: ADC1 Configuration Register (C8051F020/1/2/3)............................79
Figure 7.5. AMX1SL: AMUX1 Channel Select Register (C8051F020/1/2/3) .....................79
Figure 7.6. ADC1CN: ADC1 Control Register (C8051F020/1/2/3) .....................................80
Figure 7.7. ADC1: ADC1 Data Word Register .....................................................................81
Figure 7.8. ADC1 Data Word Example.................................................................................81
Table 7.1. ADC1 Electrical Characteristics..........................................................................82
8. DACS, 12-BIT VOLTAGE MODE......................................................................................83
Figure 8.1. DAC Functional Block Diagram.........................................................................83
Figure 8.2. DAC0H: DAC0 High Byte Register ...................................................................85
Figure 8.3. DAC0L: DAC0 Low Byte Register ....................................................................85
Figure 8.4. DAC0CN: DAC0 Control Register .....................................................................86
Figure 8.5. DAC1H: DAC1 High Byte Register ...................................................................87
Figure 8.6. DAC1L: DAC1 Low Byte Register ....................................................................87
Figure 8.7. DAC1CN: DAC1 Control Register .....................................................................88
Table 8.1. DAC Electrical Characteristics............................................................................89
9. VOLTAGE REFERENCE (C8051F020/2)..........................................................................91
C8051F020/1/2/3
Rev. 1.4 11
Figure 9.1. Voltage Reference Functional Block Diagram....................................................91
Figure 9.2. REF0CN: Reference Control Register ................................................................92
Table 9.1. Voltage Reference Electrical Characteristics ......................................................92
10. VOLTAGE REFERENCE (C8051F021/3)..........................................................................93
Figure 10.1. Voltage Reference Functional Block Diagram ...................................................93
Figure 10.2. REF0CN: Reference Control Register ................................................................94
Table 10.1. Voltage Reference Electrical Characteristics ......................................................94
11. COMPARATORS..................................................................................................................95
Figure 11.1. Comparator Functional Block Diagram..............................................................95
Figure 11.2. Comparator Hysteresis Plot.................................................................................96
Figure 11.3. CPT0CN: Comparator0 Control Register ...........................................................97
Figure 11.4. CPT1CN: Comparator1 Control Register ...........................................................98
Table 11.1. Comparator Electrical Characteristics.................................................................99
12. CIP-51 MICROCONTROLLER........................................................................................101
Figure 12.1. CIP-51 Block Diagram......................................................................................101
Table 12.1. CIP-51 Instruction Set Summary.......................................................................103
Figure 12.2. Memory Map.....................................................................................................107
Table 12.2. Special Function Register (SFR) Memory Map................................................109
Table 12.3. Special Function Registers ................................................................................109
Figure 12.3. SP: Stack Pointer ...............................................................................................113
Figure 12.4. DPL: Data Pointer Low Byte ............................................................................113
Figure 12.5. DPH: Data Pointer High Byte ...........................................................................113
Figure 12.6. PSW: Program Status Word..............................................................................114
Figure 12.7. ACC: Accumulator............................................................................................115
Figure 12.8. B: B Register .....................................................................................................115
Table 12.4. Interrupt Summary.............................................................................................117
Figure 12.9. IE: Interrupt Enable...........................................................................................119
Figure 12.10. IP: Interrupt Priority ........................................................................................120
Figure 12.11. EIE1: Extended Interrupt Enable 1 .................................................................121
Figure 12.12. EIE2: Extended Interrupt Enable 2 .................................................................122
Figure 12.13. EIP1: Extended Interrupt Priority 1.................................................................123
Figure 12.14. EIP2: Extended Interrupt Priority 2.................................................................124
Figure 12.15. PCON: Power Control.....................................................................................126
13. RESET SOURCES ..............................................................................................................127
Figure 13.1. Reset Sources ....................................................................................................127
Figure 13.2. Reset Timing .....................................................................................................128
Figure 13.3. WDTCN: Watchdog Timer Control Register ...................................................131
Figure 13.4. RSTSRC: Reset Source Register.......................................................................132
Table 13.1. Reset Electrical Characteristics .........................................................................133
14. OSCILLATORS...................................................................................................................135
Figure 14.1. Oscillator Diagram............................................................................................135
Figure 14.2. OSCICN: Internal Oscillator Control Register .................................................136
Table 14.1. Internal Oscillator Electrical Characteristics.....................................................136
Figure 14.3. OSCXCN: External Oscillator Control Register...............................................137
15. FLASH MEMORY..............................................................................................................139
C8051F020/1/2/3
12 Rev. 1.4
Table 15.1. FLASH Electrical Characteristics .....................................................................140
Figure 15.1. FLASH Program Memory Map and Security Bytes .........................................141
Figure 15.2. FLACL: FLASH Access Limit .........................................................................142
Figure 15.3. FLSCL: FLASH Memory Control ....................................................................143
Figure 15.4. PSCTL: Program Store Read/Write Control .....................................................144
16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM.......................145
Figure 16.1. EMI0CN: External Memory Interface Control .................................................147
Figure 16.2. EMI0CF: External Memory Configuration.......................................................147
Figure 16.3. Multiplexed Configuration Example.................................................................148
Figure 16.4. Non-multiplexed Configuration Example.........................................................149
Figure 16.5. EMIF Operating Modes.....................................................................................150
Figure 16.6. EMI0TC: External Memory Timing Control ....................................................152
Figure 16.7. Non-multiplexed 16-bit MOVX Timing ...........................................................153
Figure 16.8. Non-multiplexed 8-bit MOVX without Bank Select Timing............................154
Figure 16.9. Non-multiplexed 8-bit MOVX with Bank Select Timing.................................155
Figure 16.10. Multiplexed 16-bit MOVX Timing.................................................................156
Figure 16.11. Multiplexed 8-bit MOVX without Bank Select Timing .................................157
Figure 16.12. Multiplexed 8-bit MOVX with Bank Select Timing.......................................158
Table 16.1. AC Parameters for External Memory Interface.................................................159
17. PORT INPUT/OUTPUT.....................................................................................................161
Figure 17.1. Port I/O Cell Block Diagram.............................................................................161
Table 17.1. Port I/O DC Electrical Characteristics ..............................................................161
Figure 17.2. Lower Port I/O Functional Block Diagram.......................................................162
Figure 17.3. Priority Crossbar Decode Table ........................................................................163
Figure 17.4. Priority Crossbar Decode Table ........................................................................166
Figure 17.5. Priority Crossbar Decode Table ........................................................................167
Figure 17.6. Crossbar Example: ............................................................................................169
Figure 17.7. XBR0: Port I/O Crossbar Register 0 .................................................................170
Figure 17.8. XBR1: Port I/O Crossbar Register 1 .................................................................171
Figure 17.9. XBR2: Port I/O Crossbar Register 2 .................................................................172
Figure 17.10. P0: Port0 Data Register ...................................................................................173
Figure 17.11. P0MDOUT: Port0 Output Mode Register.......................................................173
Figure 17.12. P1: Port1 Data Register ...................................................................................174
Figure 17.13. P1MDIN: Port1 Input Mode Register .............................................................174
Figure 17.14. P1MDOUT: Port1 Output Mode Register.......................................................175
Figure 17.15. P2: Port2 Data Register ...................................................................................175
Figure 17.16. P2MDOUT: Port2 Output Mode Register.......................................................175
Figure 17.17. P3: Port3 Data Register ...................................................................................176
Figure 17.18. P3MDOUT: Port3 Output Mode Register.......................................................176
Figure 17.19. P3IF: Port3 Interrupt Flag Register .................................................................177
Figure 17.20. P74OUT: Ports 7 - 4 Output Mode Register ...................................................179
Figure 17.21. P4: Port4 Data Register ...................................................................................180
Figure 17.22. P5: Port5 Data Register ...................................................................................180
Figure 17.23. P6: Port6 Data Register ...................................................................................181
Figure 17.24. P7: Port7 Data Register ...................................................................................181
C8051F020/1/2/3
Rev. 1.4 13
18. SYSTEM MANAGEMENT BUS / I2C BUS (SMBUS0) .................................................183
Figure 18.1. SMBus0 Block Diagram ...................................................................................183
Figure 18.2. Typical SMBus Configuration ..........................................................................184
Figure 18.3. SMBus Transaction ...........................................................................................185
Figure 18.4. Typical Master Transmitter Sequence...............................................................187
Figure 18.5. Typical Master Receiver Sequence ...................................................................187
Figure 18.6. Typical Slave Transmitter Sequence.................................................................188
Figure 18.7. Typical Slave Receiver Sequence .....................................................................188
Figure 18.8. SMB0CN: SMBus0 Control Register ...............................................................191
Figure 18.9. SMB0CR: SMBus0 Clock Rate Register ..........................................................192
Figure 18.10. SMB0DAT: SMBus0 Data Register ...............................................................193
Figure 18.11. SMB0ADR: SMBus0 Address Register..........................................................193
Figure 18.12. SMB0STA: SMBus0 Status Register..............................................................194
Table 18.1. SMB0STA Status Codes and States..................................................................195
19. SERIAL PERIPHERAL INTERFACE BUS (SPI0) ........................................................197
Figure 19.1. SPI Block Diagram............................................................................................197
Figure 19.2. Typical SPI Interconnection..............................................................................198
Figure 19.3. Full Duplex Operation.......................................................................................199
Figure 19.4. Data/Clock Timing Diagram.............................................................................200
Figure 19.5. SPI0CFG: SPI0 Configuration Register............................................................201
Figure 19.6. SPI0CN: SPI0 Control Register ........................................................................202
Figure 19.7. SPI0CKR: SPI0 Clock Rate Register ................................................................203
Figure 19.8. SPI0DAT: SPI0 Data Register ..........................................................................203
20. UART0 ..................................................................................................................................205
Figure 20.1. UART0 Block Diagram.....................................................................................205
Table 20.1. UART0 Modes ..................................................................................................206
Figure 20.2. UART0 Mode 0 Interconnect............................................................................206
Figure 20.3. UART0 Mode 0 Timing Diagram.....................................................................206
Figure 20.4. UART0 Mode 1 Timing Diagram.....................................................................207
Figure 20.5. UART Modes 2 and 3 Timing Diagram............................................................208
Figure 20.6. UART Modes 1, 2, and 3 Interconnect Diagram ..............................................209
Figure 20.7. UART Multi-Processor Mode Interconnect Diagram.......................................210
Table 20.2. Oscillator Frequencies for Standard Baud Rates...............................................212
Figure 20.8. SCON0: UART0 Control Register....................................................................213
Figure 20.9. SBUF0: UART0 Data Buffer Register..............................................................214
Figure 20.10. SADDR0: UART0 Slave Address Register ....................................................214
Figure 20.11. SADEN0: UART0 Slave Address Enable Register ........................................214
21. UART1 ..................................................................................................................................215
Figure 21.1. UART1 Block Diagram.....................................................................................215
Table 21.1. UART1 Modes ..................................................................................................216
Figure 21.2. UART1 Mode 0 Interconnect............................................................................216
Figure 21.3. UART1 Mode 0 Timing Diagram.....................................................................216
Figure 21.4. UART1 Mode 1 Timing Diagram.....................................................................217
Figure 21.5. UART Modes 2 and 3 Timing Diagram............................................................218
Figure 21.6. UART Modes 1, 2, and 3 Interconnect Diagram ..............................................219
C8051F020/1/2/3
14 Rev. 1.4
Figure 21.7. UART Multi-Processor Mode Interconnect Diagram.......................................220
Table 21.2. Oscillator Frequencies for Standard Baud Rates...............................................222
Figure 21.8. SCON1: UART1 Control Register....................................................................223
Figure 21.9. SBUF1: UART1 Data Buffer Register..............................................................224
Figure 21.10. SADDR1: UART1 Slave Address Register ....................................................224
Figure 21.11. SADEN1: UART1 Slave Address Enable Register ........................................224
22. TIMERS................................................................................................................................225
Figure 22.1. CKCON: Clock Control Register......................................................................226
Figure 22.2. T0 Mode 0 Block Diagram................................................................................228
Figure 22.3. T0 Mode 2 (8-bit Auto-Reload) Block Diagram...............................................229
Figure 22.4. T0 Mode 3 (Two 8-bit Timers) Block Diagram................................................230
Figure 22.5. TCON: Timer Control Register.........................................................................231
Figure 22.6. TMOD: Timer Mode Register...........................................................................232
Figure 22.7. TL0: Timer 0 Low Byte ....................................................................................233
Figure 22.8. TL1: Timer 1 Low Byte ....................................................................................233
Figure 22.9. TH0 Timer 0 High Byte ....................................................................................233
Figure 22.10. TH1: Timer 1 High Byte .................................................................................233
Figure 22.11. T2 Mode 0 Block Diagram..............................................................................235
Figure 22.12. T2 Mode 1 Block Diagram..............................................................................236
Figure 22.13. T2 Mode 2 Block Diagram..............................................................................237
Figure 22.14. T2CON: Timer 2 Control Register..................................................................238
Figure 22.15. RCAP2L: Timer 2 Capture Register Low Byte ..............................................239
Figure 22.16. RCAP2H: Timer 2 Capture Register High Byte .............................................239
Figure 22.17. TL2: Timer 2 Low Byte ..................................................................................239
Figure 22.18. TH2 Timer 2 High Byte ..................................................................................239
Figure 22.19. Timer 3 Block Diagram...................................................................................240
Figure 22.20. TMR3CN: Timer 3 Control Register ..............................................................241
Figure 22.21. TMR3RLL: Timer 3 Reload Register Low Byte ............................................241
Figure 22.22. TMR3RLH: Timer 3 Reload Register High Byte ...........................................242
Figure 22.23. TMR3L: Timer 3 Low Byte ............................................................................242
Figure 22.24. TMR3H: Timer 3 High Byte...........................................................................242
Figure 22.25. T4 Mode 0 Block Diagram..............................................................................244
Figure 22.26. T4 Mode 1 Block Diagram..............................................................................245
Figure 22.27. T4 Mode 2 Block Diagram..............................................................................246
Figure 22.28. T4CON: Timer 4 Control Register..................................................................247
Figure 22.29. RCAP4L: Timer 4 Capture Register Low Byte ..............................................248
Figure 22.30. RCAP4H: Timer 4 Capture Register High Byte .............................................248
Figure 22.31. TL4: Timer 4 Low Byte ..................................................................................248
Figure 22.32. TH4 Timer 4 High Byte ..................................................................................248
23. PROGRAMMABLE COUNTER ARRAY.......................................................................249
Figure 23.1. PCA Block Diagram..........................................................................................249
Figure 23.2. PCA Counter/Timer Block Diagram.................................................................250
Table 23.1. PCA Timebase Input Options............................................................................250
Figure 23.3. PCA Interrupt Block Diagram...........................................................................252
Table 23.2. PCA0CPM Register Settings for PCA Capture/Compare Modules..................252
C8051F020/1/2/3
Rev. 1.4 15
Figure 23.4. PCA Capture Mode Diagram............................................................................253
Figure 23.5. PCA Software Timer Mode Diagram................................................................254
Figure 23.6. PCA High Speed Output Mode Diagram..........................................................255
Figure 23.7. PCA Frequency Output Mode...........................................................................256
Figure 23.8. PCA 8-Bit PWM Mode Diagram......................................................................257
Figure 23.9. PCA 16-Bit PWM Mode ...................................................................................258
Figure 23.10. PCA0CN: PCA Control Register ....................................................................259
Figure 23.11. PCA0MD: PCA0 Mode Register ....................................................................260
Figure 23.12. PCA0CPMn: PCA0 Capture/Compare Mode Registers .................................261
Figure 23.13. PCA0L: PCA0 Counter/Timer Low Byte .......................................................262
Figure 23.14. PCA0H: PCA0 Counter/Timer High Byte ......................................................262
Figure 23.15. PCA0CPLn: PCA0 Capture Module Low Byte ..............................................263
Figure 23.16. PCA0CPHn: PCA0 Capture Module High Byte.............................................263
24. JTAG (IEEE 1149.1)............................................................................................................265
Figure 24.1. IR: JTAG Instruction Register ..........................................................................265
Table 24.1. Boundary Data Register Bit Definitions............................................................266
Figure 24.2. DEVICEID: JTAG Device ID Register ............................................................267
Figure 24.3. FLASHCON: JTAG Flash Control Register.....................................................269
Figure 24.4. FLASHADR: JTAG Flash Address Register ....................................................270
Figure 24.5. FLASHDAT: JTAG Flash Data Register..........................................................270
C8051F020/1/2/3
16 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 17
1. SYSTEM OVERVIEW
The C8051F020/1/2/3 devices are fully integrated mixed-signal System-on-a-Chip MCUs with 64 digital I/O pins
(C8051F020/2) or 32 digital I/O pins (C8051F021/3). Highlighted features are listed below; refer to Table 1.1 for
specific product feature selection.
High-Speed pipelined 8051-compatible CIP-51 microcontroller core (up to 25 MIPS)
In-system, full-speed, non-intrusive debug interface (on-chip)
True 12-bit (C8051F020/1) or 10-bit (C8051F022/3) 100 ksps 8-channel ADC with PGA and analog multiplexer
True 8-bit ADC 500 ksps 8-channel ADC with PGA and analog multiplexer
Two 12-bit DACs with programmable update scheduling
64k bytes of in-system programmable FLASH memory
4352 (4096 + 256) bytes of on-chip RAM
External Data Memory Interface with 64k byte address space
SPI, SMBus/I
2
C, and (2) UART serial interfaces implemented in hardware
Five general purpose 16-bit Timers
Programmable Counter/Timer Array with five capture/compare modules
On-chip Watchdog Timer, VDD Monitor, and Temperature Sensor
With on-chip VDD monitor, Watchdog Timer, and clock oscillator, the C8051F020/1/2/3 devices are truly stand-
alone System-on-a-Chip solutions. All analog and digital peripherals are enabled/disabled and configured by user
firmware. The FLASH memory can be reprogrammed even in-circuit, providing non-volatile data storage, and also
allowing field upgrades of the 8051 firmware.
On-board JTAG debug circuitry allows non-intrusive (uses no on-chip resources), full speed, in-circuit debugging
using the production MCU installed in the final application. This debug system supports inspection and modification
of memory and registers, setting breakpoints, watchpoints, single stepping, run and halt commands. All analog and
digital peripherals are fully functional while debugging using JTAG.
Each MCU is specified for 2.7 V-to-3.6 V operation over the industrial temperature range (-45 C to +85 C). The
Port I/Os, /RST, and JTAG pins are tolerant for input signals up to 5 V. The C8051F020/2 are available in a 100-pin
TQFP package (see block diagrams in Figure 1.1 and Figure 1.3). The C8051F021/3 are available in a 64-pin TQFP
package (see block diagrams in Figure 1.2 and Figure 1.4).
Table 1.1. Product Selection Guide
M
I
P
S
(
P
e
a
k
)
F
L
A
S
H
M
e
m
o
r
y
R
A
M
E
x
t
e
r
n
a
l
M
e
m
o
r
y
I
n
t
e
r
f
a
c
e
S
M
B
u
s
/
I
2
C
S
P
I
U
A
R
T
S
T
i
m
e
r
s
(
1
6
-
b
i
t
)
P
r
o
g
r
a
m
m
a
b
l
e
C
o
u
n
t
e
r
A
r
r
a
y
D
i
g
i
t
a
l
P
o
r
t
I
/
O
s
1
2
-
b
i
t
1
0
0
k
s
p
s
A
D
C
I
n
p
u
t
s
1
0
-
b
i
t
1
0
0
k
s
p
s
A
D
C
I
n
p
u
t
s
8
-
b
i
t
5
0
0
k
s
p
s
A
D
C
I
n
p
u
t
s
V
o
l
t
a
g
e
R
e
f
e
r
e
n
c
e
T
e
m
p
e
r
a
t
u
r
e
S
e
n
s
o
r
D
A
C
R
e
s
o
l
u
t
i
o
n
(
b
i
t
s
)
D
A
C
O
u
t
p
u
t
s
A
n
a
l
o
g
C
o
m
p
a
r
a
t
o
r
s
P
a
c
k
a
g
e
C8051F020 25 64k 4352 2 5 64 8 - 8 12 2 2 100TQFP
C8051F021 25 64k 4352 2 5 32 8 - 8 12 2 2 64TQFP
C8051F022 25 64k 4352 2 5 64 - 8 8 12 2 2 100TQFP
C8051F023 25 64k 4352 2 5 32 - 8 8 12 2 2 64TQFP
C8051F020/1/2/3
18 Rev. 1.4
Figure 1.1. C8051F020 Block Diagram
P0, P1,
P2, P3
Latches
JTAG
Logic
TCK
TMS
TDI
TDO
UART1
SMBus
SPI Bus
PCA
64kbyte
FLASH
256 byte
RAM
VDD
Monitor
SFR Bus
8
0
5
1
C
o
r
e
Timers 0,
1, 2, 4
Timer 3/
RTC
P0
Drv
C
R
O
S
S
B
A
R
Port I/O
Config.
Crossbar
Config.
AV+
AV+
VDD
VDD
VDD
DGND
DGND
DGND
AGND
AGND
Reset /RST
XTAL1
XTAL2
External
Oscillator
Circuit
System
Clock
Internal
Oscillator
Digital Power
Analog Power
Debug HW
Boundary Scan
4kbyte
RAM
P2.0
P2.7
P1.0/AIN1.0
P1.7/AIN1.7
P0.0
P0.7
P1
Drv
P2
Drv
Data Bus
Address Bus
Bus Control
DAC1
DAC1
(12-Bit)
VREF
DAC0
(12-Bit)
ADC
100ksps
(12-Bit)
A
M
U
X
AIN0.0
AIN0.1
AIN0.2
AIN0.3
AIN0.4
AIN0.5
AIN0.6
AIN0.7
DAC0
CP0+
CP0-
CP1+
CP1-
VREF
TEMP
SENSOR
UART0
P3.0
P3.7
P3
Drv
8:1
MONEN WDT
VREFD
VREF0
Prog
Gain
CP0
CP1
C
T
L
P4 Latch
D
a
t
a
P7 Latch
A
d
d
r
P5 Latch
P6 Latch
P7.0/D0
P7.7/D7
P7
DRV
P5.0/A8
P5.7/A15
P5
DRV
P6.0/A0
P6.7/A7
P6
DRV
P4
DRV
P4.5/ALE
P4.6/RD
P4.7/WR
P4.0
P4.4
External Data Memory Bus
Prog
Gain
ADC
500ksps
(8-Bit)
A
M
U
X
VREF1
C8051F020/1/2/3
Rev. 1.4 19
Figure 1.2. C8051F021 Block Diagram
P0, P1,
P2, P3
Latches
JTAG
Logic
TCK
TMS
TDI
TDO
UART1
SMBus
SPI Bus
PCA
64kbyte
FLASH
256 byte
RAM
VDD
Monitor
SFR Bus
8
0
5
1
C
o
r
e
Timers 0,
1, 2, 4
Timer 3/
RTC
P0
Drv
C
R
O
S
S
B
A
R
Port I/O
Config.
Crossbar
Config.
AV+
VDD
VDD
VDD
DGND
DGND
DGND
AGND
Reset /RST
XTAL1
XTAL2
External
Oscillator
Circuit
System
Clock
Internal
Oscillator
Digital Power
Analog Power
Debug HW
Boundary Scan
4kbyte
RAM
P2.0
P2.7
P1.0/AIN1.0
P1.7/AIN1.7
P0.0
P0.7
P1
Drv
P2
Drv
Data Bus
Address Bus
Bus Control
DAC1
DAC1
(12-Bit)
VREF
DAC0
(12-Bit)
ADC
100ksps
(12-Bit)
A
M
U
X
AIN0.0
AIN0.1
AIN0.2
AIN0.3
AIN0.4
AIN0.5
AIN0.6
AIN0.7
DAC0
CP0+
CP0-
CP1+
CP1-
VREF
TEMP
SENSOR
UART0
P3.0
P3.7
P3
Drv
8:1
MONEN WDT
VREFA
Prog
Gain
CP0
CP1
C
T
L
P4 Latch
D
a
t
a
P7 Latch
A
d
d
r
P5 Latch
P6 Latch
P7
DRV
P5
DRV
P6
DRV
P4
DRV
External Data Memory Bus
Prog
Gain
ADC
500ksps
(8-Bit)
A
M
U
X
VREFA
AV+
C8051F020/1/2/3
20 Rev. 1.4
P0, P1,
P2, P3
Latches
JTAG
Logic
TCK
TMS
TDI
TDO
UART1
SMBus
SPI Bus
PCA
64kbyte
FLASH
256 byte
RAM
VDD
Monitor
SFR Bus
8
0
5
1
C
o
r
e
Timers 0,
1, 2, 4
Timer 3/
RTC
P0
Drv
C
R
O
S
S
B
A
R
Port I/O
Config.
Crossbar
Config.
AV+
AV+
VDD
VDD
VDD
DGND
DGND
DGND
AGND
AGND
Reset /RST
XTAL1
XTAL2
External
Oscillator
Circuit
System
Clock
Internal
Oscillator
Digital Power
Analog Power
Debug HW
Boundary Scan
4kbyte
RAM
P2.0
P2.7
P1.0/AIN1.0
P1.7/AIN1.7
P0.0
P0.7
P1
Drv
P2
Drv
Data Bus
Address Bus
Bus Control
DAC1
DAC1
(12-Bit)
VREF
DAC0
(12-Bit)
ADC
100ksps
(10-Bit)
A
M
U
X
AIN0.0
AIN0.1
AIN0.2
AIN0.3
AIN0.4
AIN0.5
AIN0.6
AIN0.7
DAC0
CP0+
CP0-
CP1+
CP1-
VREF
TEMP
SENSOR
UART0
P3.0
P3.7
P3
Drv
8:1
MONEN WDT
VREFD
VREF0
Prog
Gain
CP0
CP1
C
T
L
P4 Latch
D
a
t
a
P7 Latch
A
d
d
r
P5 Latch
P6 Latch
P7.0/D0
P7.7/D7
P7
DRV
P5.0/A8
P5.7/A15
P5
DRV
P6.0/A0
P6.7/A7
P6
DRV
P4
DRV
P4.5/ALE
P4.6/RD
P4.7/WR
P4.0
P4.4
External Data Memory Bus
Prog
Gain
ADC
500ksps
(8-Bit)
A
M
U
X
VREF1
Figure 1.3. C8051F022 Block Diagram
C8051F020/1/2/3
Rev. 1.4 21
P0, P1,
P2, P3
Latches
JTAG
Logic
TCK
TMS
TDI
TDO
UART1
SMBus
SPI Bus
PCA
64kbyte
FLASH
256 byte
RAM
VDD
Monitor
SFR Bus
8
0
5
1
C
o
r
e
Timers 0,
1, 2, 4
Timer 3/
RTC
P0
Drv
C
R
O
S
S
B
A
R
Port I/O
Config.
Crossbar
Config.
AV+
VDD
VDD
VDD
DGND
DGND
DGND
AGND
Reset /RST
XTAL1
XTAL2
External
Oscillator
Circuit
System
Clock
Internal
Oscillator
Digital Power
Analog Power
Debug HW
Boundary Scan
4kbyte
RAM
P2.0
P2.7
P1.0/AIN1.0
P1.7/AIN1.7
P0.0
P0.7
P1
Drv
P2
Drv
Data Bus
Address Bus
Bus Control
DAC1
DAC1
(12-Bit)
VREF
DAC0
(12-Bit)
ADC
100ksps
(10-Bit)
A
M
U
X
AIN0.0
AIN0.1
AIN0.2
AIN0.3
AIN0.4
AIN0.5
AIN0.6
AIN0.7
DAC0
CP0+
CP0-
CP1+
CP1-
VREF
TEMP
SENSOR
UART0
P3.0
P3.7
P3
Drv
8:1
MONEN WDT
VREFA
Prog
Gain
CP0
CP1
C
T
L
P4 Latch
D
a
t
a
P7 Latch
A
d
d
r
P5 Latch
P6 Latch
P7
DRV
P5
DRV
P6
DRV
P4
DRV
External Data Memory Bus
Prog
Gain
ADC
500ksps
(8-Bit)
A
M
U
X
VREFA
AV+
Figure 1.4. C8051F023 Block Diagram
C8051F020/1/2/3
22 Rev. 1.4
1.1. CIP-51 Microcontroller Core
1.1.1. Fully 8051 Compatible
The C8051F020 family utilizes Silicon Labs' proprietary CIP-51 microcontroller core. The CIP-51 is fully compati-
ble with the MCS-51 instruction set; standard 803x/805x assemblers and compilers can be used to develop soft-
ware. The core has all the peripherals included with a standard 8052, including five 16-bit counter/timers, two full-
duplex UARTs, 256 bytes of internal RAM, 128 byte Special Function Register (SFR) address space, and 8/4 byte-
wide I/O Ports.
1.1.2. Improved Throughput
The CIP-51 employs a pipelined architecture that greatly increases its instruction throughput over the standard 8051
architecture. In a standard 8051, all instructions except for MUL and DIV take 12 or 24 system clock cycles to exe-
cute with a maximum system clock of 12-to-24 MHz. By contrast, the CIP-51 core executes 70% of its instructions in
one or two system clock cycles, with only four instructions taking more than four system clock cycles.
The CIP-51 has a total of 109 instructions. The table below shows the total number of instructions that require each
execution time.
With the CIP-51's maximum system clock at 25 MHz, it has a peak throughput of 25 MIPS. Figure 1.5 shows a com-
parison of peak throughputs of various 8-bit microcontroller cores with their maximum system clocks.
Clocks to Execute 1 2 2/3 3 3/4 4 4/5 5 8
Number of Instructions 26 50 5 14 7 3 1 2 1
5
10
15
20
ADuC812
8051
(16MHz clk)
Philips
80C51
(33MHz clk)
Microchip
PIC17C75x
(33MHz clk)
Silicon Labs
CIP-51
(25MHz clk)
M
I
P
S
25
Figure 1.5. Comparison of Peak MCU Execution Speeds
C8051F020/1/2/3
Rev. 1.4 23
1.1.3. Additional Features
The C8051F020 MCU family includes several key enhancements to the CIP-51 core and peripherals to improve over-
all performance and ease of use in end applications.
The extended interrupt handler provides 22 interrupt sources into the CIP-51 (as opposed to 7 for the standard 8051),
allowing the numerous analog and digital peripherals to interrupt the controller. An interrupt driven system requires
less intervention by the MCU, giving it more effective throughput. The extra interrupt sources are very useful when
building multi-tasking, real-time systems.
There are up to seven reset sources for the MCU: an on-board VDD monitor, a Watchdog Timer, a missing clock
detector, a voltage level detection from Comparator0, a forced software reset, the CNVSTR input pin, and the /RST
pin. The /RST pin is bi-directional, accommodating an external reset, or allowing the internally generated POR to be
output on the /RST pin. Each reset source except for the VDD monitor and Reset Input pin may be disabled by the
user in software; the VDD monitor is enabled/disabled via the MONEN pin. The Watchdog Timer may be perma-
nently enabled in software after a power-on reset during MCU initialization.
The MCU has an internal, stand alone clock generator which is used by default as the system clock after any reset. If
desired, the clock source may be switched on the fly to the external oscillator, which can use a crystal, ceramic reso-
nator, capacitor, RC, or external clock source to generate the system clock. This can be extremely useful in low power
applications, allowing the MCU to run from a slow (power saving) external crystal source, while periodically switch-
ing to the fast (up to 16 MHz) internal oscillator as needed.
WDT
XTAL1
XTAL2
OSC
Internal
Clock
Generator
System
Clock
CIP-51
Microcontroller
Core
Missing
Clock
Detector
(one-
shot)
W
D
T
S
t
r
o
b
e
Software Reset
Extended Interrupt
Handler
Clock Select
/RST
+
-
VDD
Supply
Reset
Timeout
(wired-OR)
System Reset
Supply
Monitor
PRE
Reset
Funnel
+
-
CP0+
Comparator0
CP0-
(Port
I/O)
Crossbar
CNVSTR
(CNVSTR
reset
enable)
(CP0
reset
enable)
EN
W
D
T
E
n
a
b
l
e
EN
M
C
D
E
n
a
b
l
e
Figure 1.6. On-Board Clock and Reset
C8051F020/1/2/3
24 Rev. 1.4
1.2. On-Chip Memory
The CIP-51 has a standard 8051 program and data address configuration. It includes 256 bytes of data RAM, with the
upper 128 bytes dual-mapped. Indirect addressing accesses the upper 128 bytes of general purpose RAM, and direct
addressing accesses the 128 byte SFR address space. The lower 128 bytes of RAM are accessible via direct and indi-
rect addressing. The first 32 bytes are addressable as four banks of general purpose registers, and the next 16 bytes
can be byte addressable or bit addressable.
The CIP-51 in the C8051F020/1/2/3 MCUs additionally has an on-chip 4k byte RAM block and an external memory
interface (EMIF) for accessing off-chip data memory. The on-chip 4k byte block can be addressed over the entire 64k
external data memory address range (overlapping 4k boundaries). External data memory address space can be
mapped to on-chip memory only, off-chip memory only, or a combination of the two (addresses up to 4k directed to
on-chip, above 4k directed to EMIF). The EMIF is also configurable for multiplexed or non-multiplexed address/data
lines.
The MCUs program memory consists of 64k bytes of FLASH. This memory may be reprogrammed in-system in
512 byte sectors, and requires no special off-chip programming voltage. The 512 bytes from addresses 0xFE00 to
0xFFFF are reserved for factory use. There is also a single 128 byte sector at address 0x10000 to 0x1007F, which
may be useful as a small table for software constants. See Figure 1.7 for the MCU system memory map.
PROGRAM/DATA MEMORY
(FLASH)
(Direct and Indirect
Addressing)
0x00
0x7F
Upper 128 RAM
(Indirect Addressing
Only)
0x80
0xFF
Special Function
Register's
(Direct Addressing Only)
DATA MEMORY (RAM)
General Purpose
Registers
0x1F
0x20
0x2F
Bit Addressable
Lower 128 RAM
(Direct and Indirect
Addressing)
0x30
INTERNAL DATA ADDRESS SPACE
EXTERNAL DATA ADDRESS SPACE
XRAM - 4096 Bytes
(accessable using MOVX
instruction)
0x0000
0x0FFF
Off-chip XRAM space
0x1000
0xFFFF
FLASH
(In-System
Programmable in 512
Byte Sectors)
0x0000
0xFFFF
RESERVED
0xFE00
0xFDFF
Scrachpad Memory
(DATA only)
0x1007F
0x10000
Figure 1.7. On-Chip Memory Map
C8051F020/1/2/3
Rev. 1.4 25
1.3. JTAG Debug and Boundary Scan
The C8051F020 family has on-chip JTAG boundary scan and debug circuitry that provides non-intrusive, full speed,
in-circuit debugging using the production part installed in the end application, via the four-pin JTAG interface. The
JTAG port is fully compliant to IEEE 1149.1, providing full boundary scan for test and manufacturing purposes.
Silicon Labs' debugging system supports inspection and modification of memory and registers, breakpoints, watch-
points, a stack monitor, and single stepping. No additional target RAM, program memory, timers, or communications
channels are required. All the digital and analog peripherals are functional and work correctly while debugging. All
the peripherals (except for the ADC and SMBus) are stalled when the MCU is halted, during single stepping, or at a
breakpoint in order to keep them synchronized.
The C8051F020DK development kit provides all the hardware and software necessary to develop application code
and perform in-circuit debugging with the C8051F020/1/2/3 MCUs. The kit includes software with a developer's stu-
dio and debugger, an integrated 8051 assembler, and an RS-232 to JTAG serial adapter. It also has a target application
board with the associated MCU installed, plus the RS-232 and JTAG cables, and wall-mount power supply. The
Development Kit requires a Windows 95/98/NT/ME/2000 computer with one available RS-232 serial port. As shown
in Figure 1.8, the PC is connected via RS-232 to the Serial Adapter. A six-inch ribbon cable connects the Serial
Adapter to the user's application board, picking up the four JTAG pins and VDD and GND. The Serial Adapter takes
its power from the application board; it requires roughly 20 mA at 2.7-3.6 V. For applications where there is not suf-
ficient power available from the target system, the provided power supply can be connected directly to the Serial
Adapter.
Silicon Labs debug environment is a vastly superior configuration for developing and debugging embedded applica-
tions compared to standard MCU emulators, which use on-board "ICE Chips" and target cables and require the MCU
in the application board to be socketed. Silicon Labs' debug environment both increases ease of use and preserves the
performance of the precision analog peripherals.
TARGET PCB
RS-232
Serial
Adapter
C8051
F020
VDD GND
JTAG (x4), VDD, GND
WINDOWS 95/98/NT/ME/2000
Silicon Labs Integrated
Development Environment
Figure 1.8. Development/In-System Debug Diagram
C8051F020/1/2/3
26 Rev. 1.4
1.4. Programmable Digital I/O and Crossbar
The standard 8051 Ports (0, 1, 2, and 3) are available on the MCUs. The C8051F020/2 have 4 additional ports (4, 5,
6, and 7) for a total of 64 general-purpose port I/O. The Port I/O behave like the standard 8051 with a few enhance-
ments.
Each Port I/O pin can be configured as either a push-pull or open-drain output. Also, the "weak pull-ups" which are
normally fixed on an 8051 can be globally disabled, providing additional power saving capabilities for low-power
applications.
Perhaps the most unique enhancement is the Digital Crossbar. This is essentially a large digital switching network
that allows mapping of internal digital system resources to Port I/O pins on P0, P1, P2, and P3. (See Figure 1.9)
Unlike microcontrollers with standard multiplexed digital I/O, all combinations of functions are supported.
The on-chip counter/timers, serial buses, HW interrupts, ADC Start of Conversion input, comparator outputs, and
other digital signals in the controller can be configured to appear on the Port I/O pins specified in the Crossbar Con-
trol registers. This allows the user to select the exact mix of general purpose Port I/O and digital resources needed for
the particular application.
External
Pins
Digital
Crossbar
Priority
Decoder
SMBus
2
SPI
4
UART0
2
PCA
2
T0, T1,
T2, T2EX,
T4,T4EX
/INT0,
/INT1
P1.0
P1.7
P2.0
P2.7
P0.0
P0.7
Highest
Priority
Lowest
Priority
8
8
Comptr.
Outputs
(
I
n
t
e
r
n
a
l
D
i
g
i
t
a
l
S
i
g
n
a
l
s
)
Highest
Priority
Lowest
Priority
UART1
/SYSCLK
CNVSTR
6
2
P3.0
P3.7
8
8
P0MDOUT, P1MDOUT,
P2MDOUT, P3MDOUT
Registers
XBR0, XBR1,
XBR2, P1MDIN
Registers
P1
I/O
Cells
P3
I/O
Cells
P0
I/O
Cells
P2
I/O
Cells
8
Port
Latches
P0
P1
P2
8
8
8
P3
8
(P2.0-P2.7)
(P1.0-P1.7)
(P0.0-P0.7)
(P3.0-P3.7)
To
ADC1
Input
To External
Memory
Interface
(EMIF)
Figure 1.9. Digital Crossbar Diagram
C8051F020/1/2/3
Rev. 1.4 27
1.5. Programmable Counter Array
The C8051F020 MCU family includes an on-board Programmable Counter/Timer Array (PCA) in addition to the five
16-bit general purpose counter/timers. The PCA consists of a dedicated 16-bit counter/timer time base with 5 pro-
grammable capture/compare modules. The timebase is clocked from one of six sources: the system clock divided by
12, the system clock divided by 4, Timer 0 overflow, an External Clock Input (ECI pin), the system clock, or the
external oscillator source divided by 8.
Each capture/compare module can be configured to operate in one of six modes: Edge-Triggered Capture, Software
Timer, High Speed Output, Frequency Output, 8-Bit Pulse Width Modulator, or 16-Bit Pulse Width Modulator. The
PCA Capture/Compare Module I/O and External Clock Input are routed to the MCU Port I/O via the Digital Cross-
bar.
1.6. Serial Ports
The C8051F020 MCU Family includes two Enhanced Full-Duplex UARTs, SPI Bus, and SMBus/I
2
C. Each of the
serial buses is fully implemented in hardware and makes extensive use of the CIP-51's interrupts, thus requiring very
little intervention by the CPU. The serial buses do not "share" resources such as timers, interrupts, or Port I/O, so any
or all of the serial buses may be used together with any other.
Capture/Compare
Module 1
Capture/Compare
Module 0
Capture/Compare
Module 2
Capture/Compare
Module 3
Capture/Compare
Module 4
C
E
X
1
E
C
I
Crossbar
C
E
X
2
C
E
X
3
C
E
X
4
C
E
X
0
Port I/O
16-Bit Counter/Timer
PCA
CLOCK
MUX
SYSCLK/12
SYSCLK/4
Timer 0 Overflow
ECI
SYSCLK
External Clock/8
Figure 1.10. PCA Block Diagram
C8051F020/1/2/3
28 Rev. 1.4
1.7. 12-Bit Analog to Digital Converter
The C8051F020/1 has an on-chip 12-bit SAR ADC (ADC0) with a 9-channel input multiplexer and programmable
gain amplifier. With a maximum throughput of 100 ksps, the ADC offers true 12-bit accuracy with an INL of 1LSB.
C8051F022/3 devices include a 10-bit SAR ADC with similar specifications and configuration options. The ADC0
voltage reference is selected between the DAC0 output and an external VREF pin. On C8051F020/2 devices, ADC0
has its own dedicated VREF0 input pin; on C8051F021/3 devices, the ADC0 shares the VREFA input pin with the 8-
bit ADC1. The on-chip 15 ppm/C voltage reference may generate the voltage reference for other system components
or the on-chip ADCs via the VREF output pin.
The ADC is under full control of the CIP-51 microcontroller via its associated Special Function Registers. One input
channel is tied to an internal temperature sensor, while the other eight channels are available externally. Each pair of
the eight external input channels can be configured as either two single-ended inputs or a single differential input.
The system controller can also put the ADC into shutdown mode to save power.
A programmable gain amplifier follows the analog multiplexer. The gain can be set in software from 0.5 to 16 in
powers of 2. The gain stage can be especially useful when different ADC input channels have widely varied input
voltage signals, or when it is necessary to "zoom in" on a signal with a large DC offset (in differential mode, a DAC
could be used to provide the DC offset).
Conversions can be started in four ways; a software command, an overflow of Timer 2, an overflow of Timer 3, or an
external signal input. This flexibility allows the start of conversion to be triggered by software events, external HW
signals, or a periodic timer overflow signal. Conversion completions are indicated by a status bit and an interrupt (if
enabled). The resulting 10 or 12-bit data word is latched into two SFRs upon completion of a conversion. The data
can be right or left justified in these registers under software control.
Window Compare registers for the ADC data can be configured to interrupt the controller when ADC data is within
or outside of a specified range. The ADC can monitor a key voltage continuously in background mode, but not inter-
rupt the controller unless the converted data is within the specified window.
12-Bit
SAR
ADC
12
+
-
TEMP
SENSOR
+
-
+
-
+
-
9-to-1
AMUX
(SE or
DIFF)
+
-
X
AIN0.0
AIN0.1
AIN0.2
AIN0.3
AIN0.4
AIN0.5
AIN0.6
AIN0.7
AV+
Programmable Gain
Amplifier
Analog Multiplexer
Window Compare
Logic
ADC Data
Registers
Window
Compare
Interrupt
Conversion
Complete
Interrupt
Configuration, Control, and Data
Registers
Start
Conversion Timer 3 Overflow
Timer 2 Overflow
Write to AD0BUSY
CNVSTR
External VREF
Pin
DAC0 Output
VREF
AGND
Figure 1.11. 12-Bit ADC Block Diagram
C8051F020/1/2/3
Rev. 1.4 29
1.8. 8-Bit Analog to Digital Converter
The C8051F020/1/2/3 has an on-board 8-bit SAR ADC (ADC1) with an 8-channel input multiplexer and programma-
ble gain amplifier. This ADC features a 500 ksps maximum throughput and true 8-bit accuracy with an INL of
1LSB. Eight input pins are available for measurement. The ADC is under full control of the CIP-51 microcontroller
via the Special Function Registers. The ADC1 voltage reference is selected between the analog power supply (AV+)
and an external VREF pin. On C8051F020/2 devices, ADC1 has its own dedicated VREF1 input pin; on
C8051F021/3 devices, ADC1 shares the VREFA input pin with the 12/10-bit ADC0. User software may put ADC1
into shutdown mode to save power.
A programmable gain amplifier follows the analog multiplexer. The gain stage can be especially useful when differ-
ent ADC input channels have widely varied input voltage signals, or when it is necessary to "zoom in" on a signal
with a large DC offset (in differential mode, a DAC could be used to provide the DC offset). The PGA gain can be set
in software to 0.5, 1, 2, or 4.
A flexible conversion scheduling system allows ADC1 conversions to be initiated by software commands, timer
overflows, or an external input signal. ADC1 conversions may also be synchronized with ADC0 software-com-
manded conversions. Conversion completions are indicated by a status bit and an interrupt (if enabled), and the
resulting 8-bit data word is latched into an SFR upon completion.
+
-
AV+
8
8-to-1
AMUX
X
AIN1.0
AIN1.1
AIN1.2
AIN1.3
AIN1.4
AIN1.5
AIN1.6
AIN1.7
Configuration, Control, and Data Registers
Programmable Gain
Amplifier
Analog Multiplexer
8-Bit
SAR
ADC
Start Conversion
Timer 3 Overflow
Timer 2 Overflow
Write to AD1BUSY
CNVSTR Input
Write to AD0BUSY
(synchronized with
ADC0)
ADC Data
Register
Conversion
Complete
Interrupt
External VREF
Pin
AV+
VREF
Figure 1.12. 8-Bit ADC Diagram
C8051F020/1/2/3
30 Rev. 1.4
1.9. Comparators and DACs
Each C8051F020/1/2/3 MCU has two 12-bit DACs and two comparators on chip. The MCU data and control inter-
face to each comparator and DAC is via the Special Function Registers. The MCU can place any DAC or comparator
in low power shutdown mode.
The comparators have software programmable hysteresis. Each comparator can generate an interrupt on its rising
edge, falling edge, or both; these interrupts are capable of waking up the MCU from sleep mode. The comparators'
output state can also be polled in software. The comparator outputs can be programmed to appear on the Port I/O pins
via the Crossbar.
The DACs are voltage output mode, and include a flexible output scheduling mechanism. This scheduling mecha-
nism allows DAC output updates to be forced by a software write or a Timer 2, 3, or 4 overflow. The DAC voltage
reference is supplied via the dedicated VREFD input pin on C8051F020/2 devices or via the internal voltage refer-
ence on C8051F021/3 devices. The DACs are especially useful as references for the comparators or offsets for the
differential inputs of the ADC.
+
- CP1
CP1+
CP1-
DAC0
DAC1
REF
REF
CP0
CIP-51
and
Interrupt
Handler
CP1
DAC0
DAC1
CP0+
CP0-
CP1
CP0
(Port I/O)
(Port I/O)
+
-
CP0
SFR's
(Data
and
Cntrl)
CROSSBAR
Figure 1.13. Comparator and DAC Diagram
C8051F020/1/2/3
Rev. 1.4 31
2. ABSOLUTE MAXIMUM RATINGS
Table 2.1. Absolute Maximum Ratings
*
PARAMETER CONDITIONS MIN TYP MAX UNITS
Ambient temperature under bias -55 125 C
Storage Temperature -65 150 C
Voltage on any Pin (except VDD and Port I/O) with
respect to DGND
-0.3
VDD +
0.3
V
Voltage on any Port I/O Pin or /RST with respect to
DGND
-0.3 5.8 V
Voltage on VDD with respect to DGND -0.3 4.2 V
Maximum Total current through VDD, AV+, DGND,
and AGND
800 mA
Maximum output current sunk by any Port pin 100 mA
Maximum output current sunk by any other I/O pin 50 mA
Maximum output current sourced by any Port pin 100 mA
Maximum output current sourced by any other I/O pin 50 mA
*
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This
is a stress rating only and functional operation of the devices at those or any other conditions above those indicated
in the operation listings of this specification is not implied. Exposure to maximum rating conditions for extended
periods may affect device reliability.
C8051F020/1/2/3
32 Rev. 1.4
3. GLOBAL DC ELECTRICAL CHARACTERISTICS
Table 1.1. Global DC Electrical Characteristics
-40C to +85C, 25 MHz System Clock unless otherwise specified.
PARAMETER CONDITIONS MIN TYP MAX UNITS
Analog Supply Voltage
2.7
3.0 3.6 V
Analog Supply Current AV+=2.7 V, Internal REF, ADC,
DAC, Comparators all active
1.7 mA
Analog Supply Current with
analog sub-systems inactive
AV+=2.7 V, Internal REF, ADC,
DAC, Comparators all disabled,
oscillator disabled, VDD Monitor
disabled
0.2 A
Analog-to-Digital Supply Delta
(|VDD - AV+|)
0.5 V
Digital Supply Voltage 2.7 3.0 3.6 V
Digital Supply Current with
CPU active
VDD=2.7 V, Clock=25 MHz
VDD=2.7 V, Clock=1 MHz
VDD=2.7 V, Clock=32 kHz
10
0.5
20
mA
mA
A
Digital Supply Current with
CPU inactive (not accessing
FLASH)
VDD=2.7 V, Clock=25 MHz
VDD=2.7 V, Clock=1 MHz
VDD=2.7 V, Clock=32 kHz
5
0.2
10
mA
mA
A
Digital Supply Current (shut-
down)
VDD=2.7 V, Oscillator not running,
VDD Monitor disabled
0.2 A
Digital Supply RAM Data
Retention Voltage
1.5 V
Specified Operating Tempera-
ture Range
-40 +85 C
SYSCLK (system clock fre-
quency)
0
25 MHz
Tsysl (SYSCLK low time) 18 ns
Tsysh (SYSCLK high time) 18 ns
Analog Supply AV+ must be greater than 1 V for VDD monitor to operate.
C8051F020/1/2/3
Rev. 1.4 131
Bits7-0: WDT Control
Writing 0xA5 both enables and reloads the WDT.
Writing 0xDE followed within 4 system clocks by 0xAD disables the WDT.
Writing 0xFF locks out the disable feature.
Bit4: Watchdog Status Bit (when Read)
Reading the WDTCN.[4] bit indicates the Watchdog Timer Status.
0: WDT is inactive
1: WDT is active
Bits2-0: Watchdog Timeout Interval Bits
The WDTCN.[2:0] bits set the Watchdog Timeout Interval. When writing these bits, WDTCN.7 must
be set to 0.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
xxxxx111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xFF
Figure 13.3. WDTCN: Watchdog Timer Control Register
C8051F020/1/2/3
132 Rev. 1.4
Figure 13.4. RSTSRC: Reset Source Register
(Note: Do not use read-modify-write operations on this register.)
Bit7: Reserved.
Bit6: CNVRSEF: Convert Start Reset Source Enable and Flag
Write: 0: CNVSTR is not a reset source.
1: CNVSTR is a reset source (active low).
Read: 0: Source of prior reset was not CNVSTR.
1: Source of prior reset was CNVSTR.
Bit5: C0RSEF: Comparator0 Reset Enable and Flag
Write: 0: Comparator0 is not a reset source.
1: Comparator0 is a reset source (active low).
Read: 0: Source of prior reset was not Comparator0.
1: Source of prior reset was Comparator0.
Bit4: SWRSF: Software Reset Force and Flag
Write: 0: No Effect.
1: Forces an internal reset. /RST pin is not affected.
Read: 0: Prior reset source was not a write to the SWRSF bit.
1: Prior reset source was a write to the SWRSF bit.
Bit3: WDTRSF: Watchdog Timer Reset Flag
0: Source of prior reset was not WDT timeout.
1: Source of prior reset was WDT timeout.
Bit2: MCDRSF: Missing Clock Detector Flag
0: Source of prior reset was not Missing Clock Detector timeout.
1: Source of prior reset was Missing Clock Detector timeout.
Bit1: PORSF: Power-On Reset Force and Flag
Write: 0: No effect.
1: Forces a Power-On Reset. /RST is driven low.
Read: 0: Source of prior reset was not POR.
1: Source of prior reset was POR.
Bit0: PINRSF: HW Pin Reset Flag
0: Source of prior reset was not /RST pin.
1: Source of prior reset was /RST pin.
R R/W R/W R/W R R R/W R Reset Value
- CNVRSEF C0RSEF SWRSEF WDTRSF MCDRSF PORSF PINRSF Variable
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xEF
C8051F020/1/2/3
Rev. 1.4 133
Table 13.1. Reset Electrical Characteristics
-40C to +85C unless otherwise specified.
PARAMETER CONDITIONS MIN TYP MAX UNITS
/RST Output High Voltage I
OH
= -3 mA
VDD -
0.7
V
/RST Output Low Voltage I
OL
= 8.5 mA, VDD = 2.7 V to 3.6 V 0.6 V
/RST Input High Voltage
0.7 x
VDD
V
/RST Input Low Voltage
0.3 x
VDD
/RST Input Leakage Current /RST = 0.0 V 50 A
VDD for /RST Output Valid 1.0 V
AV+ for /RST Output Valid 1.0 V
VDD POR Threshold (V
RST
) 2.40 2.55 2.70 V
Minimum /RST Low Time to
Generate a System Reset
10 ns
Reset Time Delay
/RST rising edge after VDD crosses
V
RST
threshold
80 100 120 ms
Missing Clock Detector Timeout
Time from last system clock to reset
initiation
100 220 500 s
C8051F020/1/2/3
134 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 135
14. OSCILLATORS
Each MCU includes an internal oscillator and an external oscillator drive circuit, either of which can generate the sys-
tem clock. The MCUs operate from the internal oscillator after any reset. This internal oscillator can be enabled/dis-
abled and its frequency can be set using the Internal Oscillator Control Register (OSCICN) as shown in Figure 14.1.
The internal oscillator's electrical specifications are given in Table 14.1.
Both oscillators are disabled when the /RST pin is held low. The MCUs can run from the internal oscillator perma-
nently, or can switch to the external oscillator if desired using CLKSL bit in the OSCICN Register. The external oscil-
lator requires an external resonator, crystal, capacitor, or RC network connected to the XTAL1/XTAL2 pins (see
Table 14.1). The oscillator circuit must be configured for one of these sources in the OSCXCN register. An external
CMOS clock can also provide the system clock; in this configuration, the XTAL1 pin is used as the CMOS clock
input. The XTAL1 and XTAL2 pins are NOT 5V tolerant.
Figure 14.1. Oscillator Diagram
OSC
Internal Clock
Generator
SYSCLK
Input
Circuit
OSCXCN
EN
X
T
L
V
L
D
X
O
S
C
M
D
2
X
O
S
C
M
D
1
X
O
S
C
M
D
0
X
F
C
N
2
X
F
C
N
1
X
F
C
N
0
OSCICN
M
S
C
L
K
E
I
F
R
D
Y
C
L
K
S
L
I
O
S
C
E
N
I
F
C
N
1
I
F
C
N
0
XTAL1
XTAL2
opt. 1
opt. 2
opt. 4 opt. 3
XTAL1
XTAL2
XTAL1 XTAL1
AV+
AGND
VDD
AV+
C8051F020/1/2/3
136 Rev. 1.4
Table 14.1. Internal Oscillator Electrical Characteristics
VDD = 2.7V to 3.6V; T
a
= -40C to +85C
PARAMETER CONDITIONS MIN TYP MAX UNITS
Internal Oscillator Frequency
OSCICN.[1:0] = 00
OSCICN.[1:0] = 01
OSCICN.[1:0] = 10
OSCICN.[1:0] = 11
1.5
3.1
6.2
12.3
2
4
8
16
2.4
4.8
9.6
19.2
MHz
Internal Oscillator Current
Consumption (from VDD)
OSCICN.2 = 1 200 A
Figure 14.2. OSCICN: Internal Oscillator Control Register
Bit7: MSCLKE: Missing Clock Enable Bit
0: Missing Clock Detector Disabled
1: Missing Clock Detector Enabled; reset triggered if clock is missing for more than 100 s
Bits6-5: UNUSED. Read = 00b, Write = don't care
Bit4: IFRDY: Internal Oscillator Frequency Ready Flag
0: Internal Oscillator Frequency not running at speed specified by the IFCN bits.
1: Internal Oscillator Frequency running at speed specified by the IFCN bits.
Bit3: CLKSL: System Clock Source Select Bit
0: Uses Internal Oscillator as System Clock.
1: Uses External Oscillator as System Clock.
Bit2: IOSCEN: Internal Oscillator Enable Bit
0: Internal Oscillator Disabled
1: Internal Oscillator Enabled
Bits1-0: IFCN1-0: Internal Oscillator Frequency Control Bits
00: Internal Oscillator typical frequency is 2 MHz.
01: Internal Oscillator typical frequency is 4 MHz.
10: Internal Oscillator typical frequency is 8 MHz.
11: Internal Oscillator typical frequency is 16 MHz.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
MSCLKE - - IFRDY CLKSL IOSCEN IFCN1 IFCN0 00010100
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB2
C8051F020/1/2/3
Rev. 1.4 137
Figure 14.3. OSCXCN: External Oscillator Control Register
Bit7: XTLVLD: Crystal Oscillator Valid Flag
(Valid only when XOSCMD = 11x.)
0: Crystal Oscillator is unused or not yet stable
1: Crystal Oscillator is running and stable
Bits6-4: XOSCMD2-0: External Oscillator Mode Bits
00x: Off. XTAL1 pin is grounded internally.
010: System Clock from External CMOS Clock on XTAL1 pin.
011: System Clock from External CMOS Clock on XTAL1 pin divided by 2.
10x: RC/C Oscillator Mode with divide by 2 stage.
110: Crystal Oscillator Mode
111: Crystal Oscillator Mode with divide by 2 stage.
Bit3: RESERVED. Read = undefined, Write = don't care
Bits2-0: XFCN2-0: External Oscillator Frequency Control Bits
000-111:
CRYSTAL MODE (Circuit from Figure 14.1, Option 1; XOSCMD = 11x)
Choose XFCN value to match the crystal or ceramic resonator frequency.
RC MODE (Circuit from Figure 14.1, Option 2; XOSCMD = 10x)
Choose oscillation frequency range where:
f = 1.23(10
3
) / (R * C), where
f = frequency of oscillation in MHz
C = capacitor value in pF
R = Pull-up resistor value in kO
C MODE (Circuit from Figure 14.1, Option 3; XOSCMD = 10x)
Choose K Factor (KF) for the oscillation frequency desired:
f = KF / (C * AV+), where
f = frequency of oscillation in MHz
C = capacitor value on XTAL1, XTAL2 pins in pF
AV+ = Analog Power Supply on MCU in volts
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
XTLVLD XOSCMD2 XOSCMD1 XOSCMD0 - XFCN2 XFCN1 XFCN0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB1
XFCN Crystal (XOSCMD = 11x) RC (XOSCMD = 10x) C (XOSCMD = 10x)
000 f < 12 kHz f < 25 kHz K Factor = 0.44
001 12 kHz < f s 30 kHz 25 kHz < f s 50 kHz K Factor = 1.4
010 30 kHz < f s 95 kHz 50 kHz < f s 100 kHz K Factor = 4.4
011 95 kHz < f s 270 kHz 100 kHz < f s 200 kHz K Factor = 13
100 270 kHz < f s 720 kHz 200 kHz < f s 400 kHz K Factor = 38
101 720 kHz < f s 2.2 MHz 400 kHz < f s 800 kHz K Factor = 100
110 2.2 MHz < f s 6.7 MHz 800 kHz < f s 1.6 MHz K Factor = 420
111 f > 6.7 MHz 1.6 MHz < f s 3.2 MHz K Factor = 1400
C8051F020/1/2/3
138 Rev. 1.4
14.1. External Crystal Example
If a crystal or ceramic resonator is used as an external oscillator source for the MCU, the circuit should be as shown
in Figure 14.1, Option 1. The External Oscillator Frequency Control value (XFCN) should be chosen from the Crys-
tal column of the table in Figure 14.3 (OSCXCN register). For example, an 11.0592 MHz crystal requires an XFCN
setting of 111b.
The Crystal Oscillator Valid Flag (XTLVLD in register OSCXCN) is set to logic 1 by hardware when the external
crystal oscillator is running and stable. The XTLVLD detection circuit requires a startup time of at least 1 ms between
enabling the oscillator and checking the XTLVLD bit. Switching to the external oscillator before the crystal oscillator
has stabilized can result in unpredictable behavior. The recommended procedure is:
Step 1. Enable the external oscillator.
Step 2. Wait at least 1 ms.
Step 3. Poll for XTLVLD => 1.
Step 4. Switch the system clock to the external oscillator.
Important Note: Crystal oscillator circuits are quite sensitive to PCB layout. The crystal should be placed as close as
possible to the XTAL pins on the device, as should the loading capacitors on the crystal pins. The traces should be as
short as possible and shielded with ground plane from any other traces which could introduce noise or interference.
14.2. External RC Example
If an RC network is used as an external oscillator source for the MCU, the circuit should be as shown in Figure 14.1,
Option 2. The capacitor must be no greater than 100 pF; however for small capacitors (less than ~20 pF), the total
capacitance may be dominated by PWB parasitic capacitance. To determine the required External Oscillator Fre-
quency Control value (XFCN) in the OSCXCN Register, first select the RC network value to produce the desired fre-
quency of oscillation. If the frequency desired is 100 kHz, let R = 246 kO and C = 50 pF:
f = 1.23( 10
3
) / RC = 1.23 ( 10
3
) / [ 246 * 50 ] = 0.1 MHz = 100 kHz
XFCN > log
2
( f / 25 kHz )
XFCN > log
2
( 100 kHz / 25 kHz ) = log
2
( 4 )
XFCN > 2, or code 010b
14.3. External Capacitor Example
If a capacitor is used as an external oscillator for the MCU, the circuit should be as shown in Figure 14.1, Option 3.
The capacitor must be no greater than 100 pF; however for small capacitors (less than ~20 pF), the total capacitance
may be dominated by PWB parasitic capacitance. To determine the required External Oscillator Frequency Control
value (XFCN) in the OSCXCN Register, select the capacitor to be used and find the frequency of oscillation from the
equations below. Assume VDD = 3.0 V and C = 50 pF:
f = KF / ( C * VDD ) = KF / ( 50 * 3 )
f = KF / 150
If a frequency of roughly 90 kHz is desired, select the K Factor from the table in Figure 14.3 as KF = 13:
f = 13 / 150 = 0.087 MHz, or 87 kHz
Therefore, the XFCN value to use in this example is 011b.
C8051F020/1/2/3
Rev. 1.4 139
15. FLASH MEMORY
The C8051F020/1/2/3 family includes 64k + 128 bytes of on-chip, reprogrammable FLASH memory for program
code and non-volatile data storage. The FLASH memory can be programmed in-system, a single byte at a time,
through the JTAG interface or by software. Once cleared to logic 0, a FLASH bit must be erased to set it back to
logic 1. The bytes would typically be erased (set to 0xFF) before being reprogrammed. FLASH write and erase oper-
ations are automatically timed by hardware for proper execution; data polling to determine the end of the write/erase
operation is not required. Refer to Table 15.1 for the electrical characteristics of the FLASH memory.
15.1. Programming The FLASH Memory
The simplest means of programming the FLASH memory is through the JTAG interface using programming tools
provided by Silicon Labs or a third party vendor. This is the only means for programming a non-initialized device.
For details on the JTAG commands to program FLASH memory, see Section 24.2. Flash Programming Com-
mands on page 268.
The FLASH memory can be programmed by software using a MOVX write instruction, with the address and data
byte to be programmed provided as normal operands. Before writing to FLASH memory using a MOVX write,
FLASH write operations must be enabled by setting the PSWE Program Store Write Enable bit (PSCTL.0) to logic 1.
This directs the MOVX writes to FLASH memory instead of XRAM. The PSWE bit remains set until cleared by soft-
ware. To avoid errant FLASH writes, it is recommended that interrupts be disabled while the PSWE bit is logic 1.
FLASH memory is read using the MOVC read instruction. MOVX reads are always directed to XRAM, regardless of
the state of PSWE.
To ensure the integrity of FLASH contents, it is strongly recommended that the on-chip VDD monitor be
enabled by tying the MONEN pin to VDD in any system which includes code that writes to or erases FLASH
memory from software.
A write to FLASH memory can clear bits but cannot set them; only an erase operation can set bits in FLASH. A byte
location to be programmed must be erased before a new value can be written. The 64k byte FLASH memory is
organized in 512-byte pages. The erase operation applies to an entire page (setting all bytes in the page to 0xFF). The
following steps illustrate the algorithm for programming FLASH by user software.
Step 1. Disable interrupts.
Step 2. Set FLWE (FLSCL.0) to enable FLASH writes/erases via user software.
Step 3. Set PSEE (PSCTL.1) to enable FLASH erases.
Step 4. Set PSWE (PSCTL.0) to redirect MOVX commands to write to FLASH.
Step 5. Use the MOVX command to write a data byte to any location within the 512-byte page to be erased.
Step 6. Clear PSEE to disable FLASH erases
Step 7. Use the MOVX command to write a data byte to the desired byte location within the erased 512-byte
page. Repeat this step until all desired bytes are written (within the target page).
Step 8. Clear the PSWE bit to redirect MOVX commands to the XRAM data space.
Step 9. Re-enable interrupts.
C8051F020/1/2/3
140 Rev. 1.4
Write/Erase timing is automatically controlled by hardware. Note that code execution in the 8051 is stalled while the
FLASH is being programmed or erased. Interrupts that are posted during a FLASH write or erase operation are held
pending until the FLASH operation has completed, at which time they are serviced by the CPU in priority order.
15.2. Non-volatile Data Storage
The FLASH memory can be used for non-volatile data storage as well as program code. This allows data such as cal-
ibration coefficients to be calculated and stored at run time. Data is written using the MOVX write instruction (as
described in the previous section) and read using the MOVC read instruction.
An additional 128-byte sector of FLASH memory is included for non-volatile data storage. Its smaller sector size
makes it particularly well suited as general purpose, non-volatile scratchpad memory. Even though FLASH memory
can be written a single byte at a time, an entire sector must be erased first. In order to change a single byte of a multi-
byte data set, the data must be moved to temporary storage. The 128-byte sector-size facilitates updating data without
wasting program memory or RAM space. The 128-byte sector is double-mapped over the 64k byte FLASH memory;
its address ranges from 0x00 to 0x7F (see Figure 15.1). To access this 128-byte sector, the SFLE bit in PSCTL must
be set to logic 1. Code execution from this 128-byte scratchpad sector is not permitted.
15.3. Security Options
The CIP-51 provides security options to protect the FLASH memory from inadvertent modification by software as
well as prevent the viewing of proprietary program code and constants. The Program Store Write Enable (PSCTL.0)
and the Program Store Erase Enable (PSCTL.1) bits protect the FLASH memory from accidental modification by
software. These bits must be explicitly set to logic 1 before software can modify the FLASH memory. Additional
security features prevent proprietary program code and data constants from being read or altered across the JTAG
interface or by software running on the system controller.
A set of security lock bytes stored at 0xFDFE and 0xFDFF protect the FLASH program memory from being read or
altered across the JTAG interface. Each bit in a security lock-byte protects one 8k-byte block of memory. Clearing a
bit to logic 0 in a Read Lock Byte prevents the corresponding block of FLASH memory from being read across the
JTAG interface. Clearing a bit in the Write/Erase Lock Byte protects the block from JTAG erasures and/or writes. The
128-byte scratchpad sector is locked only when all other sectors are locked.
The Read Lock Byte is at location 0xFDFF. The Write/Erase Lock Byte is located at 0xFDFE. Figure 15.1 shows the
location and bit definitions of the security bytes. The 512-byte sector containing the lock bytes can be written to, but
not erased by software. An attempted read of a read-locked byte returns undefined data. Debugging code in a read-
locked sector is not possible through the JTAG port.
Table 15.1. FLASH Electrical Characteristics
VDD = 2.7V to 3.6V; T
a
= -40C to +85C
PARAMETER CONDITIONS MIN TYP MAX UNITS
Endurance 20k 100k Erase/Write
Erase Cycle Time 10 12 14 ms
Write Cycle Time 40 50 60 s
C8051F020/1/2/3
Rev. 1.4 141
The lock bits can always be read and cleared to logic 0 regardless of the security setting applied to the block contain-
ing the security bytes. This allows additional blocks to be protected after the block containing the security bytes has
been locked. Important Note: The only means of removing a lock once set is to erase the entire program mem-
ory space by performing a JTAG erase operation (i.e. cannot be done in user firmware). Addressing either
security byte while performing a JTAG erase operation will automatically initiate erasure of the entire pro-
gram memory space (except for the reserved area). This erasure can only be performed via JTAG. If a non-
security byte in the 0xFBFF-0xFDFF page is addressed during the JTAG erasure, only that page (including the
security bytes) will be erased.
The FLASH Access Limit security feature (see Figure 15.1) protects proprietary program code and data from being
read by software running on the C8051F020/1/2/3. This feature provides support for OEMs that wish to program the
0xFE00
0xFDFE
Program/Data
Memory Space
0x0000
0xFDFF Read Lock Byte
Write/Erase Lock Byte
Software Read Limit
Reserved
0xFFFF
0xFDFD
SFLE = 0
Bit Memory Block
7
6
5
4
0xC000 - 0xDFFF
0xE000 - 0xFDFD
0xA000 - 0xBFFF
0x8000 - 0x9FFF
3
2
1
0
0x4000 - 0x5FFF
0x6000 - 0x7FFF
0x2000 - 0x3FFF
0x0000 - 0x1FFF
Read and Write/Erase Security Bits.
(Bit 7 is MSB.)
0x007F
0x0000
Scratchpad Memory
(Data only)
SFLE = 1
Figure 15.1. FLASH Program Memory Map and Security Bytes
FLASH Read Lock Byte
Bits7-0: Each bit locks a corresponding block of memory. (Bit7 is MSB).
0: Read operations are locked (disabled) for corresponding block across the JTAG interface.
1: Read operations are unlocked (enabled) for corresponding block across the JTAG interface.
FLASH Write/Erase Lock Byte
Bits7-0: Each bit locks a corresponding block of memory.
0: Write/Erase operations are locked (disabled) for corresponding block across the JTAG interface.
1: Write/Erase operations are unlocked (enabled) for corresponding block across the JTAG interface.
NOTE: When the highest block is locked, the security bytes may be written but not erased.
FLASH access Limit Register (FLACL)
The content of this register is used as the high byte of the 16-bit software read limit address. This 16-
bit read limit address value is calculated as 0xNN00 where NN is replaced by content of this register
on reset. Software running at or above this address is prohibited from using the MOVX and MOVC
instructions to read, write, or erase FLASH locations below this address. Any attempts to read loca-
tions below this limit will return the value 0x00.
C8051F020/1/2/3
142 Rev. 1.4
MCU with proprietary value-added firmware before distribution. The value-added firmware can be protected while
allowing additional code to be programmed in remaining program memory space later.
The Software Read Limit (SRL) is a 16-bit address that establishes two logical partitions in the program memory
space. The first is an upper partition consisting of all the program memory locations at or above the SRL address, and
the second is a lower partition consisting of all the program memory locations starting at 0x0000 up to (but exclud-
ing) the SRL address. Software in the upper partition can execute code in the lower partition, but is prohibited from
reading locations in the lower partition using the MOVC instruction. (Executing a MOVC instruction from the upper
partition with a source address in the lower partition will always return a data value of 0x00.) Software running in the
lower partition can access locations in both the upper and lower partition without restriction.
The Value-added firmware should be placed in the lower partition. On reset, control is passed to the value-added
firmware via the reset vector. Once the value-added firmware completes its initial execution, it branches to a predeter-
mined location in the upper partition. If entry points are published, software running in the upper partition may exe-
cute program code in the lower partition, but it cannot read the contents of the lower partition. Parameters may be
passed to the program code running in the lower partition either through the typical method of placing them on the
stack or in registers before the call or by placing them in prescribed memory locations in the upper partition.
The SRL address is specified using the contents of the FLASH Access Register. The 16-bit SRL address is calculated
as 0xNN00, where NN is the contents of the SRL Security Register. Thus, the SRL can be located on 256-byte bound-
aries anywhere in program memory space. However, the 512-byte erase sector size essentially requires that a 512
boundary be used. The contents of a non-initialized SRL security byte is 0x00, thereby setting the SRL address to
0x0000 and allowing read access to all locations in program memory space by default.
Bits 7-0: FLACL: FLASH Access Limit.
This register holds the high byte of the 16-bit program memory read/write/erase limit address. The
entire 16-bit access limit address value is calculated as 0xNN00 where NN is replaced by contents of
FLACL. A write to this register sets the FLASH Access Limit. This register can only be written once
after any reset. Any subsequent writes are ignored until the next reset.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB7
Figure 15.2. FLACL: FLASH Access Limit
C8051F020/1/2/3
Rev. 1.4 143
Figure 15.3. FLSCL: FLASH Memory Control
Bit7: FOSE: FLASH One-Shot Timer Enable
This is the timer that turns off the sense amps after a FLASH read.
0: FLASH One-Shot Timer disabled.
1: FLASH One-Shot Timer enabled.
Bit6: FRAE: FLASH Read Always Enable
0: FLASH reads per One-Shot Timer.
1: FLASH always in read mode.
Bits5-1: RESERVED. Read = 00000b. Must Write 00000b.
Bit0: FLWE: FLASH Read/Write Enable
This bit must be set to allow FLASH writes from user software.
0: FLASH writes disabled.
1: FLASH writes enabled.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
FOSE FRAE Reserved Reserved Reserved Reserved Reserved FLWE 10000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB6
C8051F020/1/2/3
144 Rev. 1.4
Figure 15.4. PSCTL: Program Store Read/Write Control
Bits7-3: UNUSED. Read = 00000b, Write = don't care.
Bit2: SFLE: Scratchpad FLASH Memory Access Enable.
When this bit is set, FLASH reads and writes from user software are directed to the 128-byte Scratch-
pad FLASH sector. When SFLE is set to logic 1, FLASH accesses out of the address range 0x00-
0x7F should not be attempted. Reads/Writes out of this range will yield unpredictable results.
0: FLASH access from user software directed to the 64k byte Program/Data FLASH sector.
1: FLASH access from user software directed to the 128 byte Scratchpad sector.
Bit1: PSEE: Program Store Erase Enable.
Setting this bit allows an entire page of the FLASH program memory to be erased provided the
PSWE bit is also set. After setting this bit, a write to FLASH memory using the MOVX instruction
will erase the entire page that contains the location addressed by the MOVX instruction. The value of
the data byte written does not matter.
0: FLASH program memory erasure disabled.
1: FLASH program memory erasure enabled.
Bit0: PSWE: Program Store Write Enable.
Setting this bit allows writing a byte of data to the FLASH program memory using the MOVX
instruction. The location must be erased before writing data.
0: Write to FLASH program memory disabled.
1: Write to FLASH program memory enabled.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
- - - - - SFLE PSEE PSWE 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8F
C8051F020/1/2/3
Rev. 1.4 145
16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM
The C8051F020/1/2/3 MCUs include 4k bytes of on-chip RAM mapped into the external data memory space
(XRAM), as well as an External Data Memory Interface which can be used to access off-chip memories and memory-
mapped devices connected to the GPIO ports. The external memory space may be accessed using the external move
instruction (MOVX) and the data pointer (DPTR), or using the MOVX indirect addressing mode using R0 or R1. If
the MOVX instruction is used with an 8-bit address operand (such as @R1), then the high byte of the 16-bit address
is provided by the External Memory Interface Control Register (EMI0CN, shown in Figure 16.1). Note: the MOVX
instruction can also be used for writing to the FLASH memory. See Section 15. FLASH MEMORY on page 139
for details. The MOVX instruction accesses XRAM by default. The EMIF can be configured to appear on the lower
I/O ports (P0-P3) or the upper I/O ports (P4-P7).
16.1. Accessing XRAM
The XRAM memory space is accessed using the MOVX instruction. The MOVX instruction has two forms, both of
which use an indirect addressing method. The first method uses the Data Pointer, DPTR, a 16-bit register which con-
tains the effective address of the XRAM location to be read or written. The second method uses R0 or R1 in combina-
tion with the EMI0CN register to generate the effective XRAM address. Examples of both of these methods are given
below.
16.1.1. 16-Bit MOVX Example
The 16-bit form of the MOVX instruction accesses the memory location pointed to by the contents of the DPTR reg-
ister. The following series of instructions reads the value of the byte at address 0x1234 into the accumulator A:
MOV DPTR, #1234h ; load DPTR with 16-bit address to read (0x1234)
MOVX A, @DPTR ; load contents of 0x1234 into accumulator A
The above example uses the 16-bit immediate MOV instruction to set the contents of DPTR. Alternately, the DPTR
can be accessed through the SFR registers DPH, which contains the upper 8-bits of DPTR, and DPL, which contains
the lower 8-bits of DPTR.
16.1.2. 8-Bit MOVX Example
The 8-bit form of the MOVX instruction uses the contents of the EMI0CN SFR to determine the upper 8-bits of the
effective address to be accessed and the contents of R0 or R1 to determine the lower 8-bits of the effective address to
be accessed. The following series of instructions read the contents of the byte at address 0x1234 into the accumulator
A.
MOV EMI0CN, #12h ; load high byte of address into EMI0CN
MOV R0, #34h ; load low byte of address into R0 (or R1)
MOVX a, @R0 ; load contents of 0x1234 into accumulator A
C8051F020/1/2/3
146 Rev. 1.4
16.2. Configuring the External Memory Interface
Configuring the External Memory Interface consists of four steps:
1. Select EMIF on Low Ports (P3, P2, P1, and P0) or High Ports (P7, P6, P5, and P4).
2. Select Multiplexed mode or Non-multiplexed mode.
3. Select the memory mode (on-chip only, split mode without bank select, split mode with bank select, or
off-chip only).
4. Set up timing to interface with off-chip memory or peripherals.
5. Select the desired output mode for the associated Ports (registers PnMDOUT, P74OUT).
Each of these four steps is explained in detail in the following sections. The Port selection, Multiplexed mode selec-
tion, and Mode bits are located in the EMI0CF register shown in Figure 16.2.
16.3. Port Selection and Configuration
The External Memory Interface can appear on Ports 3, 2, 1, and 0 (C8051F020/1/2/3 devices) or on Ports 7, 6, 5, and
4 (C8051F020/2 devices only), depending on the state of the PRTSEL bit (EMI0CF.5). If the lower Ports are selected,
the EMIFLE bit (XBR2.1) must be set to a 1 so that the Crossbar will skip over P0.7 (/WR), P0.6 (/RD), and if mul-
tiplexed mode is selected P0.5 (ALE). For more information about the configuring the Crossbar, see Section
17. PORT INPUT/OUTPUT on page 161.
The External Memory Interface claims the associated Port pins for memory operations ONLY during the execution of
an off-chip MOVX instruction. Once the MOVX instruction has completed, control of the Port pins reverts to the Port
latches or to the Crossbar (on Ports 3, 2, 1, and 0). See Section 17. PORT INPUT/OUTPUT on page 161 for
more information about the Crossbar and Port operation and configuration. The Port latches should be explicitly
configured to park the External Memory Interface pins in a dormant state, most commonly by setting them
to a logic 1.
During the execution of the MOVX instruction, the External Memory Interface will explicitly disable the drivers on
all Port pins that are acting as Inputs (Data[7:0] during a READ operation, for example). The Output mode of the Port
pins (whether the pin is configured as Open-Drain or Push-Pull) is unaffected by the External Memory Interface oper-
ation, and remains controlled by the PnMDOUT registers. See Section 17. PORT INPUT/OUTPUT on page 161
for more information about Port output mode configuration.
C8051F020/1/2/3
Rev. 1.4 147
Figure 16.1. EMI0CN: External Memory Interface Control
Bits7-0: PGSEL[7:0]: XRAM Page Select Bits.
The XRAM Page Select Bits provide the high byte of the 16-bit external data memory address when
using an 8-bit MOVX command, effectively selecting a 256-byte page of RAM.
0x00: 0x0000 to 0x00FF
0x01: 0x0100 to 0x01FF
...
0xFE: 0xFE00 to 0xFEFF
0xFF: 0xFF00 to 0xFFFF
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
PGSEL7 PGSEL6 PGSEL5 PGSEL4 PGSEL3 PGSEL2 PGSEL1 PGSEL0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xAF
Figure 16.2. EMI0CF: External Memory Configuration
Bits7-6: Unused. Read = 00b. Write = dont care.
Bit5: PRTSEL: EMIF Port Select.
0: EMIF active on P0-P3.
1: EMIF active on P4-P7.
Bit4: EMD2: EMIF Multiplex Mode Select.
0: EMIF operates in multiplexed address/data mode.
1: EMIF operates in non-multiplexed mode (separate address and data pins).
Bits3-2: EMD1-0: EMIF Operating Mode Select.
These bits control the operating mode of the External Memory Interface.
00: Internal Only: MOVX accesses on-chip XRAM only. All effective addresses alias to on-chip
memory space.
01: Split Mode without Bank Select: Accesses below the 4k boundary are directed on-chip. Accesses
above the 4k boundary are directed off-chip. 8-bit off-chip MOVX operations use the current contents
of the Address High port latches to resolve upper address byte. Note that in order to access off-chip
space, EMI0CN must be set to a page that is not contained in the on-chip address space.
10: Split Mode with Bank Select: Accesses below the 4k boundary are directed on-chip. Accesses
above the 4k boundary are directed off-chip. 8-bit off-chip MOVX operations use the contents of
EMI0CN to determine the high-byte of the address.
11: External Only: MOVX accesses off-chip XRAM only. On-chip XRAM is not visible to the CPU.
Bits1-0: EALE1-0: ALE Pulse-Width Select Bits (only has effect when EMD2 = 0).
00: ALE high and ALE low pulse width = 1 SYSCLK cycle.
01: ALE high and ALE low pulse width = 2 SYSCLK cycles.
10: ALE high and ALE low pulse width = 3 SYSCLK cycles.
11: ALE high and ALE low pulse width = 4 SYSCLK cycles.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
- - PRTSEL EMD2 EMD1 EMD0 EALE1 EALE0 00000011
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA3
C8051F020/1/2/3
148 Rev. 1.4
16.4. Multiplexed and Non-multiplexed Selection
The External Memory Interface is capable of acting in a Multiplexed mode or a Non-multiplexed mode, depending
on the state of the EMD2 (EMI0CF.4) bit.
16.4.1. Multiplexed Configuration
In Multiplexed mode, the Data Bus and the lower 8-bits of the Address Bus share the same Port pins: AD[7:0]. In this
mode, an external latch (74HC373 or equivalent logic gate) is used to hold the lower 8-bits of the RAM address. The
external latch is controlled by the ALE (Address Latch Enable) signal, which is driven by the External Memory Inter-
face logic. An example of a Multiplexed Configuration is shown in Figure 16.3.
In Multiplexed mode, the external MOVX operation can be broken into two phases delineated by the state of the ALE
signal. During the first phase, ALE is high and the lower 8-bits of the Address Bus are presented to AD[7:0]. During
this phase, the address latch is configured such that the Q outputs reflect the states of the D inputs. When ALE
falls, signaling the beginning of the second phase, the address latch outputs remain fixed and are no longer dependent
on the latch inputs. Later in the second phase, the Data Bus controls the state of the AD[7:0] port at the time /RD or
/WR is asserted.
See Section 16.6.2. Multiplexed Mode on page 156 for more information.
ADDRESS/DATA BUS
ADDRESS BUS
E
M
I
F
A[15:8]
AD[7:0]
/WR
/RD
ALE
64K X 8
SRAM
OE
WE
I/O[7:0]
74HC373
G
D Q
A[15:8]
A[7:0]
CE
V
DD
8
Figure 16.3. Multiplexed Configuration Example
C8051F020/1/2/3
Rev. 1.4 149
16.4.2. Non-multiplexed Configuration
In Non-multiplexed mode, the Data Bus and the Address Bus pins are not shared. An example of a Non-multiplexed
Configuration is shown in Figure 16.4. See Section 16.6.1. Non-multiplexed Mode on page 153 for more infor-
mation about Non-multiplexed operation.
ADDRESS BUS
E
M
I
F
A[15:0]
64K X 8
SRAM
A[15:0]
DATA BUS D[7:0] I/O[7:0]
V
DD
8
/WR
/RD OE
WE
CE
Figure 16.4. Non-multiplexed Configuration Example
C8051F020/1/2/3
150 Rev. 1.4
16.5. Memory Mode Selection
The external data memory space can be configured in one of four modes, shown in Figure 16.5, based on the EMIF
Mode bits in the EMI0CF register (Figure 16.2). These modes are summarized below. More information about the
different modes can be found in Section . on page 152.
16.5.1. Internal XRAM Only
When EMI0CF.[3:2] are set to 00, all MOVX instructions will target the internal XRAM space on the device. Mem-
ory accesses to addresses beyond the populated space will wrap on 4k boundaries. As an example, the addresses
0x1000 and 0x2000 both evaluate to address 0x0000 in on-chip XRAM space.
8-bit MOVX operations use the contents of EMI0CN to determine the high-byte of the effective address and R0
or R1 to determine the low-byte of the effective address.
16-bit MOVX operations use the contents of the 16-bit DPTR to determine the effective address.
16.5.2. Split Mode without Bank Select
When EMI0CF.[3:2] are set to 01, the XRAM memory map is split into two areas, on-chip space and off-chip space.
Effective addresses below the 4k boundary will access on-chip XRAM space.
Effective addresses beyond the 4k boundary will access off-chip space.
8-bit MOVX operations use the contents of EMI0CN to determine whether the memory access is on-chip or off-
chip. The lower 8-bits of the Address Bus A[7:0] are driven as defined by R0 or R1. However, in the No Bank
Select mode, an 8-bit MOVX operation will not drive the upper 8-bits A[15:8] of the Address Bus during an
off-chip access. This allows the user to manipulate the upper address bits at will by setting the Port state directly.
This behavior is in contrast with Split Mode with Bank Select described below.
16-bit MOVX operations use the contents of DPTR to determine whether the memory access is on-chip or off-
chip, and unlike 8-bit MOVX operations, the full 16-bits of the Address Bus A[15:0] are driven during the off-
chip transaction.
EMI0CF[3:2] = 00
0xFFFF
0x0000
EMI0CF[3:2] = 11
0xFFFF
0x0000
EMI0CF[3:2] = 01
0xFFFF
0x0000
EMI0CF[3:2] = 10
On-Chip XRAM
On-Chip XRAM
On-Chip XRAM
On-Chip XRAM
On-Chip XRAM
On-Chip XRAM
Off-Chip
Memory
(No Bank Select)
On-Chip XRAM
0xFFFF
0x0000
Off-Chip
Memory
(Bank Select)
On-Chip XRAM
Off-Chip
Memory
Figure 16.5. EMIF Operating Modes
C8051F020/1/2/3
Rev. 1.4 151
16.5.3. Split Mode with Bank Select
When EMI0CF.[3:2] are set to 10, the XRAM memory map is split into two areas, on-chip space and off-chip space.
Effective addresses below the 4k boundary will access on-chip XRAM space.
Effective addresses beyond the 4k boundary will access off-chip space.
8-bit MOVX operations use the contents of EMI0CN to determine whether the memory access is on-chip or off-
chip. The upper 8-bits of the Address Bus A[15:8] are determined by EMI0CN, and the lower 8-bits of the
Address Bus A[7:0] are determined by R0 or R1. All 16-bits of the Address Bus A[15:0] are driven in Bank
Select mode.
16-bit MOVX operations use the contents of DPTR to determine whether the memory access is on-chip or off-
chip, and the full 16-bits of the Address Bus A[15:0] are driven during the off-chip transaction.
16.5.4. External Only
When EMI0CF[3:2] are set to 11, all MOVX operations are directed to off-chip space. On-chip XRAM is not visi-
ble to the CPU. This mode is useful for accessing off-chip memory located between 0x0000 and the 4k boundary.
8-bit MOVX operations ignore the contents of EMI0CN. The upper Address bits A[15:8] are not driven (identi-
cal behavior to an off-chip access in Split Mode without Bank Select described above). This allows the user to
manipulate the upper address bits at will by setting the Port state directly. The lower 8-bits of the effective
address A[7:0] are determined by the contents of R0 or R1.
16-bit MOVX operations use the contents of DPTR to determine the effective address A[15:0]. The full 16-bits
of the Address Bus A[15:0] are driven during the off-chip transaction.
16.6. Timing
The timing parameters of the External Memory Interface can be configured to enable connection to devices having
different setup and hold time requirements. The Address Setup time, Address Hold time, /RD and /WR strobe widths,
and in multiplexed mode, the width of the ALE pulse are all programmable in units of SYSCLK periods through
EMI0TC, shown in Figure 16.6, and EMI0CF[1:0].
The timing for an off-chip MOVX instruction can be calculated by adding 4 SYSCLK cycles to the timing parameters
defined by the EMI0TC register. Assuming non-multiplexed operation, the minimum execution time for an off-chip
XRAM operation is 5 SYSCLK cycles (1 SYSCLK for /RD or /WR pulse + 4 SYSCLKs). For multiplexed opera-
tions, the Address Latch Enable signal will require a minimum of 2 additional SYSCLK cycles. Therefore, the mini-
mum execution time of an off-chip XRAM operation in multiplexed mode is 7 SYSCLK cycles (2 SYSCLKs for
/ALE, 1 for /RD or /WR + 4 SYSCLKs). The programmable setup and hold times default to the maximum delay set-
tings after a reset.
Table 16.1 lists the AC parameters for the External Memory Interface, and Figure 16.7 through Figure 16.11 show the
timing diagrams for the different External Memory Interface modes and MOVX operations
C8051F020/1/2/3
152 Rev. 1.4
.
Figure 16.6. EMI0TC: External Memory Timing Control
Bits7-6: EAS1-0: EMIF Address Setup Time Bits.
00: Address setup time = 0 SYSCLK cycles.
01: Address setup time = 1 SYSCLK cycle.
10: Address setup time = 2 SYSCLK cycles.
11: Address setup time = 3 SYSCLK cycles.
Bits5-2: EWR3-0: EMIF /WR and /RD Pulse-Width Control Bits.
0000: /WR and /RD pulse width = 1 SYSCLK cycle.
0001: /WR and /RD pulse width = 2 SYSCLK cycles.
0010: /WR and /RD pulse width = 3 SYSCLK cycles.
0011: /WR and /RD pulse width = 4 SYSCLK cycles.
0100: /WR and /RD pulse width = 5 SYSCLK cycles.
0101: /WR and /RD pulse width = 6 SYSCLK cycles.
0110: /WR and /RD pulse width = 7 SYSCLK cycles.
0111: /WR and /RD pulse width = 8 SYSCLK cycles.
1000: /WR and /RD pulse width = 9 SYSCLK cycles.
1001: /WR and /RD pulse width = 10 SYSCLK cycles.
1010: /WR and /RD pulse width = 11 SYSCLK cycles.
1011: /WR and /RD pulse width = 12 SYSCLK cycles.
1100: /WR and /RD pulse width = 13 SYSCLK cycles.
1101: /WR and /RD pulse width = 14 SYSCLK cycles.
1110: /WR and /RD pulse width = 15 SYSCLK cycles.
1111: /WR and /RD pulse width = 16 SYSCLK cycles.
Bits1-0: EAH1-0: EMIF Address Hold Time Bits.
00: Address hold time = 0 SYSCLK cycles.
01: Address hold time = 1 SYSCLK cycle.
10: Address hold time = 2 SYSCLK cycles.
11: Address hold time = 3 SYSCLK cycles.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
EAS1 EAS0 EWR3 EWR2 EWR1 EWR0 EAH1 EAH0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA1
C8051F020/1/2/3
Rev. 1.4 153
16.6.1. Non-multiplexed Mode
16.6.1.1. 16-bit MOVX: EMI0CF[4:2] = 101, 110, or 111.
EMIF ADDRESS (8 MSBs) from DPH
EMIF ADDRESS (8 LSBs) from DPL P2/P6
P1/P5
P0.7/P4.7
P0.6/P4.6
P3/P7 EMIF WRITE DATA
P2/P6
P1/P5
P0.7/P4.7
P0.6/P4.6
P3/P7
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/WR
/RD
EMIF ADDRESS (8 MSBs) from DPH
EMIF ADDRESS (8 LSBs) from DPL P2/P6
P1/P5
P0.6/P4.6
P0.7/P4.7
P3/P7
P2/P6
P1/P5
P0.6/P4.6
P0.7/P4.7
P3/P7
T
ACH
T
RDH
T
ACW
T
ACS
T
RDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/RD
/WR
EMIF READ DATA
Nonmuxed 16-bit WRITE
Nonmuxed 16-bit READ
Figure 16.7. Non-multiplexed 16-bit MOVX Timing
C8051F020/1/2/3
154 Rev. 1.4
16.6.1.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 101 or 111.
EMIF ADDRESS (8 LSBs) from R0 or R1 P2/P6
P1/P5
P0.7/P4.7
P0.6/P4.6
P3/P7 EMIF WRITE DATA
P2/P6
P0.7/P4.7
P0.6/P4.6
P3/P7
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/WR
/RD
EMIF ADDRESS (8 LSBs) from R0 or R1 P2/P6
P1/P5
P0.6/P4.6
P0.7/P4.7
P3/P7
P2/P6
P0.6/P4.6
P0.7/P4.7
P3/P7
T
ACH
T
RDH
T
ACW
T
ACS
T
RDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/RD
/WR
EMIF READ DATA
Nonmuxed 8-bit WRITE without Bank Select
Nonmuxed 8-bit READ without Bank Select
Figure 16.8. Non-multiplexed 8-bit MOVX without Bank Select Timing
C8051F020/1/2/3
Rev. 1.4 155
16.6.1.3. 8-bit MOVX with Bank Select: EMI0CF[4:2] = 110.
EMIF ADDRESS (8 MSBs) from EMI0CN
EMIF ADDRESS (8 LSBs) from R0 or R1 P2/P6
P1/P5
P0.7/P4.7
P0.6/P4.6
P3/P7 EMIF WRITE DATA
P2/P6
P1/P5
P0.7/P4.7
P0.6/P4.6
P3/P7
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/WR
/RD
EMIF ADDRESS (8 MSBs) from EMI0CN
EMIF ADDRESS (8 LSBs) from R0 or R1 P2/P6
P1/P5
P0.6/P4.6
P0.7/P4.7
P3/P7
P2/P6
P1/P5
P0.6/P4.6
P0.7/P4.7
P3/P7
T
ACH
T
RDH
T
ACW
T
ACS
T
RDS
ADDR[15:8]
ADDR[7:0]
DATA[7:0]
/RD
/WR
EMIF READ DATA
Nonmuxed 8-bit WRITE with Bank Select
Nonmuxed 8-bit READ with Bank Select
Figure 16.9. Non-multiplexed 8-bit MOVX with Bank Select Timing
C8051F020/1/2/3
156 Rev. 1.4
16.6.2. Multiplexed Mode
16.6.2.1. 16-bit MOVX: EMI0CF[4:2] = 001, 010, or 011.
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P2/P6
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ALE
/WR
/RD
EMIF ADDRESS (8 MSBs) from DPH
EMIF WRITE DATA
EMIF ADDRESS (8 LSBs) from
DPL
T
ALEH
T
ALEL
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P2/P6
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
T
ACH
T
ACW
T
ACS
ALE
/RD
/WR
EMIF ADDRESS (8 MSBs) from DPH
EMIF ADDRESS (8 LSBs) from
DPL
T
ALEH
T
ALEL T
RDH
T
RDS
EMIF READ DATA
Muxed 16-bit WRITE
Muxed 16-bit READ
Figure 16.10. Multiplexed 16-bit MOVX Timing
C8051F020/1/2/3
Rev. 1.4 157
16.6.2.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 001 or 011.
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ALE
/WR
/RD
EMIF WRITE DATA
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
T
ACH
T
ACW
T
ACS
ALE
/RD
/WR
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL T
RDH
T
RDS
EMIF READ DATA
Muxed 8-bit WRITE Without Bank Select
Muxed 8-bit READ Without Bank Select
Figure 16.11. Multiplexed 8-bit MOVX without Bank Select Timing
C8051F020/1/2/3
158 Rev. 1.4
16.6.2.3. 8-bit MOVX with Bank Select: EMI0CF[4:2] = 010.
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P2/P6
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
P0.7/P4.7
P0.6/P4.6
P0.5/P4.5
T
ACH
T
WDH
T
ACW
T
ACS
T
WDS
ALE
/WR
/RD
EMIF ADDRESS (8 MSBs) from EMI0CN
EMIF WRITE DATA
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL
P3/P7
P2/P6
P3/P7
ADDR[15:8]
AD[7:0]
P2/P6
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
P0.6/P4.6
P0.7/P4.7
P0.5/P4.5
T
ACH
T
ACW
T
ACS
ALE
/RD
/WR
EMIF ADDRESS (8 MSBs) from EMI0CN
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL T
RDH
T
RDS
EMIF READ DATA
Muxed 8-bit WRITE with Bank Select
Muxed 8-bit READ with Bank Select
Figure 16.12. Multiplexed 8-bit MOVX with Bank Select Timing
C8051F020/1/2/3
Rev. 1.4 159
Table 16.1. AC Parameters for External Memory Interface
PARAMETER DESCRIPTION MIN MAX UNITS
T
SYSCLK
System Clock Period 40 ns
T
ACS
Address / Control Setup Time 0 3*T
SYSCLK
ns
T
ACW
Address / Control Pulse Width 1*T
SYSCLK
16*T
SYSCLK
ns
T
ACH
Address / Control Hold Time 0 3*T
SYSCLK
ns
T
ALEH
Address Latch Enable High Time 1*T
SYSCLK
4*T
SYSCLK
ns
T
ALEL
Address Latch Enable Low Time 1*T
SYSCLK
4*T
SYSCLK
ns
T
WDS
Write Data Setup Time 1*T
SYSCLK
19*T
SYSCLK
ns
T
WDH
Write Data Hold Time 0 3*T
SYSCLK
ns
T
RDS
Read Data Setup Time 20 ns
T
RDH
Read Data Hold Time 0 ns
C8051F020/1/2/3
160 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 161
17. PORT INPUT/OUTPUT
The C8051F020/1/2/3 are fully integrated mixed-signal System on a Chip MCUs with 64 digital I/O pins
(C8051F020/2) or 32 digital I/O pins (C8051F021/3), organized as 8-bit Ports. The lower ports: P0, P1, P2, and P3,
are both bit- and byte-addressable through their corresponding Port Data registers. The upper ports: P4, P5, P6, and
P7 are byte-addressable. All Port pins are 5 V-tolerant, and all support configurable Open-Drain or Push-Pull output
modes and weak pull-ups. A block diagram of the Port I/O cell is shown in Figure 17.1. Complete Electrical Specifi-
cations for the Port I/O pins are given in Table 16.1.
Table 17.1. Port I/O DC Electrical Characteristics
VDD = 2.7 V to 3.6 V, -40C to +85C unless otherwise specified.
PARAMETER CONDITIONS MIN TYP MAX UNITS
Output High Voltage (V
OH
) I
OH
= -10 A, Port I/O Push-Pull
I
OH
= -3 mA, Port I/O Push-Pull
I
OH
= -10 mA, Port I/O Push-Pull
VDD - 0.1
VDD - 0.7
VDD - 0.8
V
Output Low Voltage (V
OL
) I
OL
= 10 A
I
OL
= 8.5 mA
I
OL
= 25 mA 1.0
0.1
0.6 V
Input High Voltage (VIH) 0.7 x VDD V
Input Low Voltage (VIL) 0.3 x
VDD
V
Input Leakage Current DGND < Port Pin < VDD, Pin Tri-state
Weak Pull-up Off
Weak Pull-up On 10
1
A
Input Capacitance 5 pF
DGND
/PORT-OUTENABLE
PORT-OUTPUT
PUSH-PULL VDD VDD
/WEAK-PULLUP
(WEAK)
PORT
PAD
ANALOG INPUT
Analog Select
(Port 1 Only)
PORT-INPUT
Figure 17.1. Port I/O Cell Block Diagram
C8051F020/1/2/3
162 Rev. 1.4
The C8051F020/1/2/3 devices have a wide array of digital resources which are available through the four lower I/O
Ports: P0, P1, P2, and P3. Each of the pins on P0, P1, P2, and P3, can be defined as a General-Purpose I/O (GPIO) pin
or can be controlled by a digital peripheral or function (like UART0 or /INT1 for example), as shown in Figure 17.2.
The system designer controls which digital functions are assigned pins, limited only by the number of pins available.
This resource assignment flexibility is achieved through the use of a Priority Crossbar Decoder. Note that the state of
a Port I/O pin can always be read from its associated Data register regardless of whether that pin has been assigned to
a digital peripheral or behaves as GPIO. The Port pins on Port 1 can be used as Analog Inputs to ADC1.
An External Memory Interface which is active during the execution of a MOVX instruction whose target address
resides in off-chip memory can be active on either the lower Ports or the upper Ports. See Section 16. EXTERNAL
DATA MEMORY INTERFACE AND ON-CHIP XRAM on page 145 for more information about the External
Memory Interface.
The upper Ports (available on C8051F020/2) can be byte-accessed as GPIO pins.
External
Pins
Digital
Crossbar
Priority
Decoder
SMBus
2
SPI
4
UART0
2
PCA
2
T0, T1,
T2, T2EX,
T4,T4EX
/INT0,
/INT1
P1.0
P1.7
P2.0
P2.7
P0.0
P0.7
Highest
Priority
Lowest
Priority
8
8
Comptr.
Outputs
(
I
n
t
e
r
n
a
l
D
i
g
i
t
a
l
S
i
g
n
a
l
s
)
Highest
Priority
Lowest
Priority
UART1
/SYSCLK
CNVSTR
6
2
P3.0
P3.7
8
8
P0MDOUT, P1MDOUT,
P2MDOUT, P3MDOUT
Registers
XBR0, XBR1,
XBR2, P1MDIN
Registers
P1
I/O
Cells
P3
I/O
Cells
P0
I/O
Cells
P2
I/O
Cells
8
Port
Latches
P0
P1
P2
8
8
8
P3
8
(P2.0-P2.7)
(P1.0-P1.7)
(P0.0-P0.7)
(P3.0-P3.7)
To
ADC1
Input
To External
Memory
Interface
(EMIF)
Figure 17.2. Lower Port I/O Functional Block Diagram
C8051F020/1/2/3
Rev. 1.4 163
17.1. Ports 0 through 3 and the Priority Crossbar Decoder
The Priority Crossbar Decoder, or Crossbar, allocates and assigns Port pins on Port 0 through Port 3 to the digital
peripherals (UARTs, SMBus, PCA, Timers, etc.) on the device using a priority order. The Port pins are allocated in
order starting with P0.0 and continue through P3.7 if necessary. The digital peripherals are assigned Port pins in a pri-
ority order which is listed in Figure 17.3, with UART0 having the highest priority and CNVSTR having the lowest
priority.
17.1.1. Crossbar Pin Assignment and Allocation
The Crossbar assigns Port pins to a peripheral if the corresponding enable bits of the peripheral are set to a logic 1 in
the Crossbar configuration registers XBR0, XBR1, and XBR2, shown in Figure 17.7, Figure 17.8, and Figure 17.9.
For example, if the UART0EN bit (XBR0.2) is set to a logic 1, the TX0 and RX0 pins will be mapped to P0.0 and
P0.1 respectively. Because UART0 has the highest priority, its pins will always be mapped to P0.0 and P0.1 when
UART0EN is set to a logic 1. If a digital peripherals enable bits are not set to a logic 1, then its ports are not accessi-
ble at the Port pins of the device. Also note that the Crossbar assigns pins to all associated functions when a serial
communication peripheral is selected (i.e. SMBus, SPI, UART). It would be impossible, for example, to assign TX0
Figure 17.3. Priority Crossbar Decode Table
(EMIFLE = 0; P1MDIN = 0xFF)
PIN I/O 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
TX0
RX0
SCK
MISO
MOSI
NSS
SDA
SCL
TX1
RX1
CEX0
CEX1
CEX2
CEX3
CEX4
ECI
ECI0E: XBR0.6
CP0
CP0E: XBR0.7
CP1
CP1E: XBR1.0
T0
T0E: XBR1.1
/INT0
INT0E: XBR1.2
T1
T1E: XBR1.3
/INT1
INT1E: XBR1.4
T2
T2E: XBR1.5
T2EX
T2EXE: XBR1.6
T4
T4E: XBR2.3
T4EX
T4EXE: XBR2.4
/SYSCLK
SYSCKE: XBR1.7
CNVSTR
CNVSTE: XBR2.0
A
L
E
/
R
D
/
W
R
A
I
N
1
.
0
/
A
8
A
I
N
1
.
1
/
A
9
A
I
N
1
.
2
/
A
1
A
I
N
1
.
3
/
A
1
A
I
N
1
.
4
/
A
1
A
I
N
1
.
5
/
A
1
A
I
N
1
.
6
/
A
1
A
I
N
1
.
7
/
A
1
A
8
m
/
A
0
A
9
m
/
A
1
A
1
0
m
/
A
2
A
1
1
m
/
A
3
A
1
2
m
/
A
4
A
1
3
m
/
A
5
A
1
4
m
/
A
6
A
1
5
m
/
A
7
A
D
0
/
D
0
A
D
1
/
D
1
A
D
2
/
D
2
A
D
3
/
D
3
A
D
4
/
D
4
A
D
5
/
D
5
A
D
6
/
D
6
A
D
7
/
D
7
P0 P1 P2 P3
AIN1 Inputs/Non-muxed Addr H Muxed Addr H/Non-muxed Addr L Muxed Data/Non-muxed Data
UART1EN:
PCA0ME:
Crossbar Register Bits
XBR0.2
XBR0.1
XBR0.0 SMB0EN:
XBR2.2
XBR0.[5:3]
UART0EN:
SPI0EN:
C8051F020/1/2/3
164 Rev. 1.4
to a Port pin without assigning RX0 as well. Each combination of enabled peripherals results in a unique device pin-
out.
All Port pins on Ports 0 through 3 that are not allocated by the Crossbar can be accessed as General-Purpose I/O
(GPIO) pins by reading and writing the associated Port Data registers (See Figure 17.10, Figure 17.12, Figure 17.15,
and Figure 17.17), a set of SFRs which are both byte- and bit-addressable. The output states of Port pins that are allo-
cated by the Crossbar are controlled by the digital peripheral that is mapped to those pins. Writes to the Port Data reg-
isters (or associated Port bits) will have no effect on the states of these pins.
A Read of a Port Data register (or Port bit) will always return the logic state present at the pin itself, regardless of
whether the Crossbar has allocated the pin for peripheral use or not. An exception to this occurs during the execution
of a read-modify-write instruction (ANL, ORL, XRL, CPL, INC, DEC, DJNZ, JBC, CLR, SET, and the bitwise MOV
operation). During the read cycle of the read-modify-write instruction, it is the contents of the Port Data register, not
the state of the Port pins themselves, which is read.
Because the Crossbar registers affect the pinout of the peripherals of the device, they are typically configured in the
initialization code of the system before the peripherals themselves are configured. Once configured, the Crossbar reg-
isters are typically left alone.
Once the Crossbar registers have been properly configured, the Crossbar is enabled by setting XBARE (XBR2.6) to a
logic 1. Until XBARE is set to a logic 1, the output drivers on Ports 0 through 3 are explicitly disabled in order
to prevent possible contention on the Port pins while the Crossbar registers and other registers which can
affect the device pinout are being written.
The output drivers on Crossbar-assigned input signals (like RX0, for example) are explicitly disabled; thus the values
of the Port Data registers and the PnMDOUT registers have no effect on the states of these pins.
17.1.2. Configuring the Output Modes of the Port Pins
The output drivers on Ports 0 through 3 remain disabled until the Crossbar is enabled by setting XBARE (XBR2.6) to
a logic 1.
The output mode of each port pin can be configured as either Open-Drain or Push-Pull; the default state is Open-
Drain. In the Push-Pull configuration, writing a logic 0 to the associated bit in the Port Data register will cause the
Port pin to be driven to GND, and writing a logic 1 will cause the Port pin to be driven to VDD. In the Open-Drain
configuration, writing a logic 0 to the associated bit in the Port Data register will cause the Port pin to be driven to
GND, and a logic 1 will cause the Port pin to assume a high-impedance state. The Open-Drain configuration is useful
to prevent contention between devices in systems where the Port pin participates in a shared interconnection in which
multiple outputs are connected to the same physical wire (like the SDA signal on an SMBus connection).
The output modes of the Port pins on Ports 0 through 3 are determined by the bits in the associated PnMDOUT regis-
ters (See Figure 17.11, Figure 17.14, Figure 17.16, and Figure 17.18). For example, a logic 1 in P3MDOUT.7 will
configure the output mode of P3.7 to Push-Pull; a logic 0 in P3MDOUT.7 will configure the output mode of P3.7 to
Open-Drain. All Port pins default to Open-Drain output.
The PnMDOUT registers control the output modes of the port pins regardless of whether the Crossbar has allocated
the Port pin for a digital peripheral or not. The exceptions to this rule are: the Port pins connected to SDA, SCL, RX0
(if UART0 is in Mode 0), and RX1 (if UART1 is in Mode 0) are always configured as Open-Drain outputs, regardless
of the settings of the associated bits in the PnMDOUT registers.
C8051F020/1/2/3
Rev. 1.4 165
17.1.3. Configuring Port Pins as Digital Inputs
A Port pin is configured as a digital input by setting its output mode to Open-Drain and writing a logic 1 to the
associated bit in the Port Data register. For example, P3.7 is configured as a digital input by setting P3MDOUT.7 to a
logic 0 and P3.7 to a logic 1.
If the Port pin has been assigned to a digital peripheral by the Crossbar and that pin functions as an input (for example
RX0, the UART0 receive pin), then the output drivers on that pin are automatically disabled.
17.1.4. External Interrupts (IE6 and IE7)
In addition to the external interrupts /INT0 and /INT1, whose Port pins are allocated and assigned by the Crossbar,
P3.6 and P3.7 can be configured to generate edge sensitive interrupts; these interrupts are configurable as falling- or
rising-edge sensitive using the IE6CF (P3IF.2) and IE7CF (P3IF.3) bits. When an active edge is detected on P3.6 or
P3.7, a corresponding External Interrupt flag (IE6 or IE7) will be set to a logic 1 in the P3IF register (See
Figure 17.19). If the associated interrupt is enabled, an interrupt will be generated and the CPU will vector to the
associated interrupt vector location. See Section 12.3. Interrupt Handler on page 116 for more information about
interrupts.
17.1.5. Weak Pull-ups
By default, each Port pin has an internal weak pull-up device enabled which provides a resistive connection (about
100 kO) between the pin and VDD. The weak pull-up devices can be globally disabled by writing a logic 1 to the
Weak Pull-up Disable bit, (WEAKPUD, XBR2.7). The weak pull-up is automatically deactivated on any pin that is
driving a logic 0; that is, an output pin will not contend with its own pull-up device. The weak pull-up device can also
be explicitly disabled on a Port 1 pin by configuring the pin as an Analog Input, as described below.
17.1.6. Configuring Port 1 Pins as Analog Inputs (AIN1.[7:0])
The pins on Port 1 can serve as analog inputs to the ADC1 analog MUX. A Port pin is configured as an Analog Input
by writing a logic 0 to the associated bit in the P1MDIN register (see Figure 17.13). All Port pins default to a Digital
Input mode. Configuring a Port pin as an analog input:
1. Disables the digital input path from the pin. This prevents additional power supply current
from being drawn when the voltage at the pin is near VDD / 2. A read of the Port Data bit will
return a logic 0 regardless of the voltage at the Port pin.
2. Disables the weak pull-up device on the pin.
3. Causes the Crossbar to skip over the pin when allocating Port pins for digital peripherals.
Note that the output drivers on a pin configured as an Analog Input are not explicitly disabled. Therefore, the
associated P1MDOUT bits of pins configured as Analog Inputs should explicitly be set to logic 0 (Open-Drain output
mode), and the associated Port Data bits should be set to logic 1 (high-impedance). Also note that it is not required to
configure a Port pin as an Analog Input in order to use it as an input to the ADC1 MUX; however, it is strongly rec-
ommended. See Section 7. ADC1 (8-Bit ADC) on page 75 for more information about ADC1.
C8051F020/1/2/3
166 Rev. 1.4
17.1.7. External Memory Interface Pin Assignments
If the External Memory Interface (EMIF) is enabled on the Low ports (Ports 0 through 3), EMIFLE (XBR2.1) should
be set to a logic 1 so that the Crossbar will not assign peripherals to P0.7 (/WR), P0.6 (/RD), and if the External Mem-
ory Interface is in Multiplexed mode, P0.5 (ALE). Figure 17.4 shows an example Crossbar Decode Table with
EMIFLE=1 and the EMIF in Multiplexed mode. Figure 17.5 shows an example Crossbar Decode Table with
EMIFLE=1 and the EMIF in Non-multiplexed mode.
If the External Memory Interface is enabled on the Low ports and an off-chip MOVX operation occurs, the External
Memory Interface will control the output states of the affected Port pins during the execution phase of the MOVX
instruction, regardless of the settings of the Crossbar registers or the Port Data registers. The output configuration of
the Port pins is not affected by the EMIF operation, except that Read operations will explicitly disable the output
drivers on the Data Bus. See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP
XRAM on page 145 for more information about the External Memory Interface.
PIN I/O 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
TX0
RX0
SCK
MISO
MOSI
NSS
SDA
SCL
TX1
RX1
CEX0
CEX1
CEX2
CEX3
CEX4
ECI
ECI0E: XBR0.6
CP0
CP0E: XBR0.7
CP1
CP1E: XBR1.0
T0
T0E: XBR1.1
/INT0
INT0E: XBR1.2
T1
T1E: XBR1.3
/INT1
INT1E: XBR1.4
T2
T2E: XBR1.5
T2EX
T2EXE: XBR1.6
T4
T4E: XBR2.3
T4EX
T4EXE: XBR2.4
/SYSCLK
SYSCKE: XBR1.7
CNVSTR
CNVSTE: XBR2.0
A
L
E
/
R
D
/
W
R
A
I
N
1
.
0
/
A
8
A
I
N
1
.
1
/
A
9
A
I
N
1
.
2
/
A
1
A
I
N
1
.
3
/
A
1
A
I
N
1
.
4
/
A
1
A
I
N
1
.
5
/
A
1
A
I
N
1
.
6
/
A
1
A
I
N
1
.
7
/
A
1
A
8
m
/
A
0
A
9
m
/
A
1
A
1
0
m
/
A
2
A
1
1
m
/
A
3
A
1
2
m
/
A
4
A
1
3
m
/
A
5
A
1
4
m
/
A
6
A
1
5
m
/
A
7
A
D
0
/
D
0
A
D
1
/
D
1
A
D
2
/
D
2
A
D
3
/
D
3
A
D
4
/
D
4
A
D
5
/
D
5
A
D
6
/
D
6
A
D
7
/
D
7
XBR2.2
XBR0.[5:3]
UART0EN:
SPI0EN:
Crossbar Register Bits
XBR0.2
XBR0.1
XBR0.0 SMB0EN:
AIN1 Inputs/Non-muxed Addr H Muxed Addr H/Non-muxed Addr L Muxed Data/Non-muxed Data
UART1EN:
PCA0ME:
P0 P1 P2 P3
Figure 17.4. Priority Crossbar Decode Table
EMIFLE = 1; EMIF in Multiplexed Mode; P1MDIN = 0xFF)
C8051F020/1/2/3
Rev. 1.4 167
Figure 17.5. Priority Crossbar Decode Table
(EMIFLE = 1; EMIF in Non-multiplexed Mode; P1MDIN = 0xFF)
PIN I/O 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
TX0
RX0
SCK
MISO
MOSI
NSS
SDA
SCL
TX1
RX1
CEX0
CEX1
CEX2
CEX3
CEX4
ECI
ECI0E: XBR0.6
CP0
CP0E: XBR0.7
CP1
CP1E: XBR1.0
T0
T0E: XBR1.1
/INT0
INT0E: XBR1.2
T1
T1E: XBR1.3
/INT1
INT1E: XBR1.4
T2
T2E: XBR1.5
T2EX
T2EXE: XBR1.6
T4
T4E: XBR2.3
T4EX
T4EXE: XBR2.4
/SYSCLK
SYSCKE: XBR1.7
CNVSTR
CNVSTE: XBR2.0
A
L
E
/
R
D
/
W
R
A
I
N
1
.
0
/
A
8
A
I
N
1
.
1
/
A
9
A
I
N
1
.
2
/
A
1
A
I
N
1
.
3
/
A
1
A
I
N
1
.
4
/
A
1
A
I
N
1
.
5
/
A
1
A
I
N
1
.
6
/
A
1
A
I
N
1
.
7
/
A
1
A
8
m
/
A
0
A
9
m
/
A
1
A
1
0
m
/
A
2
A
1
1
m
/
A
3
A
1
2
m
/
A
4
A
1
3
m
/
A
5
A
1
4
m
/
A
6
A
1
5
m
/
A
7
A
D
0
/
D
0
A
D
1
/
D
1
A
D
2
/
D
2
A
D
3
/
D
3
A
D
4
/
D
4
A
D
5
/
D
5
A
D
6
/
D
6
A
D
7
/
D
7
XBR2.2
XBR0.[5:3]
UART0EN:
SPI0EN:
Crossbar Register Bits
XBR0.2
XBR0.1
XBR0.0 SMB0EN:
AIN1 Inputs/Non-muxed Addr H Muxed Addr H/Non-muxed Addr L Muxed Data/Non-muxed Data
UART1EN:
PCA0ME:
P0 P1 P2 P3
C8051F020/1/2/3
168 Rev. 1.4
17.1.8. Crossbar Pin Assignment Example
In this example (Figure 17.6), we configure the Crossbar to allocate Port pins for UART0, the SMBus, UART1,
/INT0, and /INT1 (8 pins total). Additionally, we configure the External Memory Interface to operate in Multiplexed
mode and to appear on the Low ports. Further, we configure P1.2, P1.3, and P1.4 for Analog Input mode so that the
voltages at these pins can be measured by ADC1. The configuration steps are as follows:
1. XBR0, XBR1, and XBR2 are set such that UART0EN = 1, SMB0EN = 1, INT0E = 1, INT1E
= 1, and EMIFLE = 1. Thus: XBR0 = 0x05, XBR1 = 0x14, and XBR2 = 0x02.
2. We configure the External Memory Interface to use Multiplexed mode and to appear on the
Low ports. PRTSEL = 0, EMD2 = 0.
3. We configure the desired Port 1 pins to Analog Input mode by setting P1MDIN to 0xE3 (P1.4,
P1.3, and P1.2 are Analog Inputs, so their associated P1MDIN bits are set to logic 0).
4. We enable the Crossbar by setting XBARE = 1: XBR2 = 0x46.
- UART0 has the highest priority, so P0.0 is assigned to TX0, and P0.1 is assigned to RX0.
- The SMBus is next in priority order, so P0.2 is assigned to SDA, and P0.3 is assigned to SCL.
- UART1 is next in priority order, so P0.4 is assigned to TX1. Because the External Memory Inter-
face is selected on the lower Ports, EMIFLE = 1, which causes the Crossbar to skip P0.6 (/RD) and
P0.7 (/WR). Because the External Memory Interface is configured in Multiplexed mode, the Cross-
bar will also skip P0.5 (ALE). RX1 is assigned to the next non-skipped pin, which in this case is
P1.0.
- /INT0 is next in priority order, so it is assigned to P1.1.
- P1MDIN is set to 0xE3, which configures P1.2, P1.3, and P1.4 as Analog Inputs, causing the
Crossbar to skip these pins.
- /INT1 is next in priority order, so it is assigned to the next non-skipped pin, which is P1.5.
- The External Memory Interface will drive Ports 2 and 3 (denoted by red dots in Figure 17.6) during
the execution of an off-chip MOVX instruction.
5. We set the UART0 TX pin (TX0, P0.0), UART1 TX pin (TX1, P0.4), ALE, /RD, /WR
(P0.[7:3]) outputs to Push-Pull by setting P0MDOUT = 0xF1.
6. We configure the output modes of the EMIF Ports (P2, P3) to Push-Pull by setting P2MDOUT
= 0xFF and P3MDOUT = 0xFF.
7. We explicitly disable the output drivers on the 3 Analog Input pins by setting P1MDOUT =
0x00 (configure outputs to Open-Drain) and P1 = 0xFF (a logic 1 selects the high-impedance
state).
C8051F020/1/2/3
Rev. 1.4 169
Figure 17.6. Crossbar Example:
(EMIFLE = 1; EMIF in Multiplexed Mode; P1MDIN = 0xE3;
XBR0 = 0x05; XBR1 = 0x14; XBR2 = 0x46)
PIN I/O 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
TX0
RX0
SCK
MISO
MOSI
NSS
SDA
SCL
TX1
RX1
CEX0
CEX1
CEX2
CEX3
CEX4
ECI
ECI0E: XBR0.6
CP0
CP0E: XBR0.7
CP1
CP1E: XBR1.0
T0
T0E: XBR1.1
/INT0
INT0E: XBR1.2
T1
T1E: XBR1.3
/INT1
INT1E: XBR1.4
T2
T2E: XBR1.5
T2EX
T2EXE: XBR1.6
T4
T4E: XBR2.3
T4EX
T4EXE: XBR2.4
/SYSCLK
SYSCKE: XBR1.7
CNVSTR
CNVSTE: XBR2.0
A
L
E
/
R
D
/
W
R
A
I
N
1
.
0
/
A
8
A
I
N
1
.
1
/
A
9
A
I
N
1
.
2
/
A
1
A
I
N
1
.
3
/
A
1
A
I
N
1
.
4
/
A
1
A
I
N
1
.
5
/
A
1
A
I
N
1
.
6
/
A
1
A
I
N
1
.
7
/
A
1
A
8
m
/
A
0
A
9
m
/
A
1
A
1
0
m
/
A
2
A
1
1
m
/
A
3
A
1
2
m
/
A
4
A
1
3
m
/
A
5
A
1
4
m
/
A
6
A
1
5
m
/
A
7
A
D
0
/
D
0
A
D
1
/
D
1
A
D
2
/
D
2
A
D
3
/
D
3
A
D
4
/
D
4
A
D
5
/
D
5
A
D
6
/
D
6
A
D
7
/
D
7
P0 P1 P2 P3
AIN1 Inputs/Non-muxed Addr H Muxed Addr H/Non-muxed Addr L Muxed Data/Non-muxed Data
UART1EN:
PCA0ME:
Crossbar Register Bits
XBR0.2
XBR0.1
XBR0.0 SMB0EN:
XBR2.2
XBR0.[5:3]
UART0EN:
SPI0EN:
C8051F020/1/2/3
170 Rev. 1.4
Figure 17.7. XBR0: Port I/O Crossbar Register 0
Bit7: CP0E: Comparator 0 Output Enable Bit.
0: CP0 unavailable at Port pin.
1: CP0 routed to Port pin.
Bit6: ECI0E: PCA0 External Counter Input Enable Bit.
0: PCA0 External Counter Input unavailable at Port pin.
1: PCA0 External Counter Input (ECI0) routed to Port pin.
Bits5-3: PCA0ME: PCA0 Module I/O Enable Bits.
000: All PCA0 I/O unavailable at Port pins.
001: CEX0 routed to Port pin.
010: CEX0, CEX1 routed to 2 Port pins.
011: CEX0, CEX1, and CEX2 routed to 3 Port pins.
100: CEX0, CEX1, CEX2, and CEX3 routed to 4 Port pins.
101: CEX0, CEX1, CEX2, CEX3, and CEX4 routed to 5 Port pins.
110: RESERVED
111: RESERVED
Bit2: UART0EN: UART0 I/O Enable Bit.
0: UART0 I/O unavailable at Port pins.
1: UART0 TX routed to P0.0, and RX routed to P0.1.
Bit1: SPI0EN: SPI0 Bus I/O Enable Bit.
0: SPI0 I/O unavailable at Port pins.
1: SPI0 SCK, MISO, MOSI, and NSS routed to 4 Port pins.
Bit0: SMB0EN: SMBus0 Bus I/O Enable Bit.
0: SMBus0 I/O unavailable at Port pins.
1: SMBus0 SDA and SCL routed to 2 Port pins.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
CP0E ECI0E PCA0ME UART0EN SPI0EN SMB0EN 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE1
C8051F020/1/2/3
Rev. 1.4 171
Figure 17.8. XBR1: Port I/O Crossbar Register 1
Bit7: SYSCKE: /SYSCLK Output Enable Bit.
0: /SYSCLK unavailable at Port pin.
1: /SYSCLK routed to Port pin.
Bit6: T2EXE: T2EX Input Enable Bit.
0: T2EX unavailable at Port pin.
1: T2EX routed to Port pin.
Bit5: T2E: T2 Input Enable Bit.
0: T2 unavailable at Port pin.
1: T2 routed to Port pin.
Bit4: INT1E: /INT1 Input Enable Bit.
0: /INT1 unavailable at Port pin.
1: /INT1 routed to Port pin.
Bit3: T1E: T1 Input Enable Bit.
0: T1 unavailable at Port pin.
1: T1 routed to Port pin.
Bit2: INT0E: /INT0 Input Enable Bit.
0: /INT0 unavailable at Port pin.
1: /INT1 routed to Port pin.
Bit1: T0E: T0 Input Enable Bit.
0: T0 unavailable at Port pin.
1: T0 routed to Port pin.
Bit0: CP1E: CP1 Output Enable Bit.
0: CP1 unavailable at Port pin.
1: CP1 routed to Port pin.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
SYSCKE T2EXE T2E INT1E T1E INT0E T0E CP1E 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE2
C8051F020/1/2/3
172 Rev. 1.4
Figure 17.9. XBR2: Port I/O Crossbar Register 2
Bit7: WEAKPUD: Weak Pull-Up Disable Bit.
0: Weak pull-ups globally enabled.
1: Weak pull-ups globally disabled.
Bit6: XBARE: Crossbar Enable Bit.
0: Crossbar disabled. All pins on Ports 0, 1, 2, and 3, are forced to Input mode.
1: Crossbar enabled.
Bit5: UNUSED. Read = 0, Write = don't care.
Bit4: T4EXE: T4EX Input Enable Bit.
0: T4EX unavailable at Port pin.
1: T4EX routed to Port pin.
Bit3: T4E: T4 Input Enable Bit.
0: T4 unavailable at Port pin.
1: T4 routed to Port pin.
Bit2: UART1E: UART1 I/O Enable Bit.
0: UART1 I/O unavailable at Port pins.
1: UART1 TX and RX routed to 2 Port pins.
Bit1: EMIFLE: External Memory Interface Low-Port Enable Bit.
0: P0.7, P0.6, and P0.5 functions are determined by the Crossbar or the Port latches.
1: If EMI0CF.4 = 0 (External Memory Interface is in Multiplexed mode)
P0.7 (/WR), P0.6 (/RD), and P0.5 (ALE) are skipped by the Crossbar and their output
states are determined by the Port latches and the External Memory Interface.
1: If EMI0CF.4 = 1 (External Memory Interface is in Non-multiplexed mode)
P0.7 (/WR) and P0.6 (/RD) are skipped by the Crossbar and their output states are
determined by the Port latches and the External Memory Interface.
Bit0: CNVSTE: External Convert Start Input Enable Bit.
0: CNVSTR unavailable at Port pin.
1: CNVSTR routed to Port pin.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
WEAKPUD XBARE - T4EXE T4E UART1E EMIFLE CNVSTE 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE3
C8051F020/1/2/3
Rev. 1.4 173
Figure 17.10. P0: Port0 Data Register
Bits7-0: P0.[7:0]: Port0 Output Latch Bits.
(Write - Output appears on I/O pins per XBR0, XBR1, XBR2, and XBR3 Registers)
0: Logic Low Output.
1: Logic High Output (open if corresponding P0MDOUT.n bit = 0).
(Read - Regardless of XBR0, XBR1, XBR2, and XBR3 Register settings).
0: P0.n pin is logic low.
1: P0.n pin is logic high.
Note: P0.7 (/WR), P0.6 (/RD), and P0.5 (ALE) can be driven by the External Data Memory Interface.
See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM on
page 145 for more information. See also Figure 17.9 for information about configuring the Crossbar
for External Memory accesses.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0x80
Figure 17.11. P0MDOUT: Port0 Output Mode Register
Bits7-0: P0MDOUT.[7:0]: Port0 Output Mode Bits.
0: Port Pin output mode is configured as Open-Drain.
1: Port Pin output mode is configured as Push-Pull.
Note: SDA, SCL, and RX0 (when UART0 is in Mode 0) and RX1 (when UART1 is in Mode 0) are always
configured as Open-Drain when they appear on Port pins.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA4
C8051F020/1/2/3
174 Rev. 1.4
Figure 17.12. P1: Port1 Data Register
Bits7-0: P1.[7:0]: Port1 Output Latch Bits.
(Write - Output appears on I/O pins per XBR0, XBR1, XBR2, and XBR3 Registers)
0: Logic Low Output.
1: Logic High Output (open if corresponding P1MDOUT.n bit = 0).
(Read - Regardless of XBR0, XBR1, XBR2, and XBR3 Register settings).
0: P1.n pin is logic low.
1: P1.n pin is logic high.
Notes:
1. P1.[7:0] can be configured as inputs to ADC1 as AIN1.[7:0], in which case they are skipped by the
Crossbar assignment process and their digital input paths are disabled, depending on P1MDIN (See
Figure 17.13). Note that in analog mode, the output mode of the pin is determined by the Port 1 latch
and P1MDOUT (Figure 17.14). See Section 7. ADC1 (8-Bit ADC) on page 75 for more informa-
tion about ADC1.
2. P1.[7:0] can be driven by the External Data Memory Interface (as Address[15:8] in Non-multiplexed
mode). See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM
on page 145 for more information about the External Memory Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P1.7 P1.6 P1.5 P1.4 P1.3 P1.2 P1.1 P1.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0x90
Figure 17.13. P1MDIN: Port1 Input Mode Register
Bits7-0: P1MDIN.[7:0]: Port 1 Input Mode Bits.
0: Port Pin is configured in Analog Input mode. The digital input path is disabled (a read from the
Port bit will always return 0). The weak pull-up on the pin is disabled.
1: Port Pin is configured in Digital Input mode. A read from the Port bit will return the logic level at
the Pin. The state of the weak pull-up is determined by the WEAKPUD bit (XBR2.7, see
Figure 17.9).
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xBD
C8051F020/1/2/3
Rev. 1.4 175
Figure 17.14. P1MDOUT: Port1 Output Mode Register
Bits7-0: P1MDOUT.[7:0]: Port1 Output Mode Bits.
0: Port Pin output mode is configured as Open-Drain.
1: Port Pin output mode is configured as Push-Pull.
Note: SDA, SCL, and RX0 (when UART0 is in Mode 0) and RX1 (when UART1 is in Mode 0) are always
configured as Open-Drain when they appear on Port pins.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA5
Figure 17.15. P2: Port2 Data Register
Bits7-0: P2.[7:0]: Port2 Output Latch Bits.
(Write - Output appears on I/O pins per XBR0, XBR1, XBR2, and XBR3 Registers)
0: Logic Low Output.
1: Logic High Output (open if corresponding P2MDOUT.n bit = 0).
(Read - Regardless of XBR0, XBR1, XBR2, and XBR3 Register settings).
0: P2.n pin is logic low.
1: P2.n pin is logic high.
Note: P2.[7:0] can be driven by the External Data Memory Interface (as Address[15:8] in Multiplexed
mode, or as Address[7:0] in Non-multiplexed mode). See Section 16. EXTERNAL DATA MEM-
ORY INTERFACE AND ON-CHIP XRAM on page 145 for more information about the External
Memory Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P2.7 P2.6 P2.5 P2.4 P2.3 P2.2 P2.1 P2.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xA0
Figure 17.16. P2MDOUT: Port2 Output Mode Register
Bits7-0: P2MDOUT.[7:0]: Port2 Output Mode Bits.
0: Port Pin output mode is configured as Open-Drain.
1: Port Pin output mode is configured as Push-Pull.
Note: SDA, SCL, and RX0 (when UART0 is in Mode 0) and RX1 (when UART1 is in Mode 0) are always
configured as Open-Drain when they appear on Port pins.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA6
C8051F020/1/2/3
176 Rev. 1.4
Figure 17.17. P3: Port3 Data Register
Bits7-0: P3.[7:0]: Port3 Output Latch Bits.
(Write - Output appears on I/O pins per XBR0, XBR1, XBR2, and XBR3 Registers)
0: Logic Low Output.
1: Logic High Output (open if corresponding P3MDOUT.n bit = 0).
(Read - Regardless of XBR0, XBR1, XBR2, and XBR3 Register settings).
0: P3.n pin is logic low.
1: P3.n pin is logic high.
Note: P3.[7:0] can be driven by the External Data Memory Interface (as AD[7:0] in Multiplexed mode, or
as D[7:0] in Non-multiplexed mode). See Section 16. EXTERNAL DATA MEMORY INTER-
FACE AND ON-CHIP XRAM on page 145 for more information about the External Memory
Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P3.7 P3.6 P3.5 P3.4 P3.3 P3.2 P3.1 P3.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xB0
Figure 17.18. P3MDOUT: Port3 Output Mode Register
Bits7-0: P3MDOUT.[7:0]: Port3 Output Mode Bits.
0: Port Pin output mode is configured as Open-Drain.
1: Port Pin output mode is configured as Push-Pull.
Note: SDA, SCL, and RX0 (when UART0 is in Mode 0) and RX1 (when UART1 is in Mode 0) are always
configured as Open-Drain when they appear on Port pins.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA7
C8051F020/1/2/3
Rev. 1.4 177
17.2. Ports 4 through 7 (C8051F020/2 only)
All Port pins on Ports 4 through 7 can be accessed as General-Purpose I/O (GPIO) pins by reading and writing the
associated Port Data registers (See Figure 17.21, Figure 17.22, Figure 17.23, and Figure 17.24), a set of SFRs which
are byte-addressable.
A Read of a Port Data register (or Port bit) will always return the logic state present at the pin itself, regardless of
whether the Crossbar has allocated the pin for peripheral use or not. An exception to this occurs during the execution
of a read-modify-write instruction (ANL, ORL, XRL, CPL, INC, DEC, DJNZ, JBC, CLR, SET, and the bitwise MOV
operation). During the read cycle of the read-modify-write instruction, it is the contents of the Port Data register, not
the state of the Port pins themselves, which is read.
17.2.1. Configuring Ports which are not Pinned Out
Although P4, P5, P6, and P7 are not brought out to pins on the C8051F021/3 devices, the Port Data registers are still
present and can be used by software. Because the digital input paths also remain active, it is recommended that these
pins not be left in a floating state in order to avoid unnecessary power dissipation arising from the inputs floating to
non-valid logic levels. This condition can be prevented by any of the following:
1. Leave the weak pull-up devices enabled by setting WEAKPUD (XBR2.7) to a logic 0.
2. Configure the output modes of P4, P5, P6, and P7 to Push-Pull by writing P74OUT = 0xFF.
3. Force the output states of P4, P5, P6, and P7 to logic 0 by writing zeros to the Port Data regis-
ters: P4 = 0x00, P5 = 0x00, P6= 0x00, and P7 = 0x00.
17.2.2. Configuring the Output Modes of the Port Pins
The output mode of each port pin can be configured to be either Open-Drain or Push-Pull. In the Push-Pull configura-
tion, a logic 0 in the associated bit in the Port Data register will cause the Port pin to be driven to GND, and a logic 1
will cause the Port pin to be driven to VDD. In the Open-Drain configuration, a logic 0 in the associated bit in the
Figure 17.19. P3IF: Port3 Interrupt Flag Register
Bit7: IE7: External Interrupt 7 Pending Flag
0: No falling edge has been detected on P3.7 since this bit was last cleared.
1: This flag is set by hardware when a falling edge on P3.7 is detected.
Bit6: IE6: External Interrupt 6 Pending Flag
0: No falling edge has been detected on P3.6 since this bit was last cleared.
1: This flag is set by hardware when a falling edge on P3.6 is detected.
Bits5-4: UNUSED. Read = 00b, Write = dont care.
Bit3: IE7CF: External Interrupt 7 Edge Configuration
0: External Interrupt 7 triggered by a falling edge on the IE7 input.
1: External Interrupt 7 triggered by a rising edge on the IE7 input.
Bit2: IE6CF: External Interrupt 6 Edge Configuration
0: External Interrupt 6 triggered by a falling edge on the IE6 input.
1: External Interrupt 6 triggered by a rising edge on the IE6 input.
Bits1-0: UNUSED. Read = 00b, Write = dont care.
R/W R/W R R R/W R/W R/W R/W Reset Value
IE7 IE6 - - IE7CF IE6CF - - 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xAD
C8051F020/1/2/3
178 Rev. 1.4
Port Data register will cause the Port pin to be driven to GND, and a logic 1 will cause the Port pin to assume a high-
impedance state. The Open-Drain configuration is useful to prevent contention between devices in systems where the
Port pin participates in a shared interconnection in which multiple outputs are connected to the same physical wire.
The output modes of the Port pins on Ports 4 through 7 are determined by the bits in the P74OUT register (see
Figure 17.20). Each bit in P74OUT controls the output mode of a 4-bit bank of Port pins on Ports 4, 5, 6, and 7. A
logic 1 in P74OUT.7 will configure the output modes of 4 most-significant bits of Port 7, P7.[7:4], to Push-Pull; a
logic 0 in P74OUT.7 will configure the output modes of P7.[7:4] to Open-Drain.
17.2.3. Configuring Port Pins as Digital Inputs
A Port pin is configured as a digital input by setting its output mode to Open-Drain and writing a logic 1 to the
associated bit in the Port Data register. For example, P7.7 is configured as a digital input by setting P74OUT.7 to a
logic 0 and P7.7 to a logic 1.
17.2.4. Weak Pull-ups
By default, each Port pin has an internal weak pull-up device enabled which provides a resistive connection (about
100 kO) between the pin and VDD. The weak pull-up devices can be globally disabled by writing a logic 1 to the
Weak Pull-up Disable bit, (WEAKPUD, XBR2.7). The weak pull-up is automatically deactivated on any pin that is
driving a logic 0; that is, an output pin will not contend with its own pull-up device.
17.2.5. External Memory Interface
If the External Memory Interface (EMIF) is enabled on the High ports (Ports 4 through 7), EMIFLE (XBR2.1) should
be set to a logic 0.
If the External Memory Interface is enabled on the High ports and an off-chip MOVX operation occurs, the External
Memory Interface will control the output states of the affected Port pins during the execution phase of the MOVX
instruction, regardless of the settings of the Port Data registers. The output configuration of the Port pins is not
affected by the EMIF operation, except that Read operations will explicitly disable the output drivers on the Data Bus
during the MOVX execution. See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP
XRAM on page 145 for more information about the External Memory Interface.
C8051F020/1/2/3
Rev. 1.4 179
Figure 17.20. P74OUT: Ports 7 - 4 Output Mode Register
Bit7: P7H: Port7 Output Mode High Nibble Bit.
0: P7.[7:4] configured as Open-Drain.
1: P7.[7:4] configured as Push-Pull.
Bit6: P7L: Port7 Output Mode Low Nibble Bit.
0: P7.[3:0] configured as Open-Drain.
1: P7.[3:0] configured as Push-Pull.
Bit5: P6H: Port6 Output Mode High Nibble Bit.
0: P6.[7:4] configured as Open-Drain.
1: P6.[7:4] configured as Push-Pull.
Bit4: P6L: Port6 Output Mode Low Nibble Bit.
0: P6.[3:0] configured as Open-Drain.
1: P6.[3:0] configured as Push-Pull.
Bit3: P5H: Port5 Output Mode High Nibble Bit.
0: P5.[7:4] configured as Open-Drain.
1: P5.[7:4] configured as Push-Pull.
Bit2: P5L: Port5 Output Mode Low Nibble Bit.
0: P5.[3:0] configured as Open-Drain.
1: P5.[3:0] configured as Push-Pull.
Bit1: P4H: Port4 Output Mode High Nibble Bit.
0: P4.[7:4] configured as Open-Drain.
1: P4.[7:4] configured as Push-Pull.
Bit0: P4L: Port4 Output Mode Low Nibble Bit.
0: P4.[3:0] configured as Open-Drain.
1: P4.[3:0] configured as Push-Pull.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P7H P7L P6H P6L P5H P5L P4H P4L 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB5
C8051F020/1/2/3
180 Rev. 1.4
Figure 17.21. P4: Port4 Data Register
Bits7-0: P4.[7:0]: Port4 Output Latch Bits.
Write - Output appears on I/O pins.
0: Logic Low Output.
1: Logic High Output (Open-Drain if corresponding P74OUT bit = 0). See Figure 17.20.
Read - Returns states of I/O pins.
0: P4.n pin is logic low.
1: P4.n pin is logic high.
Note: P4.7 (/WR), P4.6 (/RD), and P4.5 (ALE) can be driven by the External Data Memory Interface.
See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM on
page 145 for more information.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P4.7 P4.6 P4.5 P4.4 P4.3 P4.2 P4.1 P4.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x84
Figure 17.22. P5: Port5 Data Register
Bits7-0: P5.[7:0]: Port5 Output Latch Bits.
Write - Output appears on I/O pins.
0: Logic Low Output.
1: Logic High Output (Open-Drain if corresponding P74OUT bit = 0). See Figure 17.20.
Read - Returns states of I/O pins.
0: P5.n pin is logic low.
1: P5.n pin is logic high.
Note: P5.[7:0] can be driven by the External Data Memory Interface (as Address[15:8] in Non-multiplexed
mode). See Section 16. EXTERNAL DATA MEMORY INTERFACE AND ON-CHIP XRAM
on page 145 for more information about the External Memory Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P5.7 P5.6 P5.5 P5.4 P5.3 P5.2 P5.1 P5.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x85
C8051F020/1/2/3
Rev. 1.4 181
Figure 17.23. P6: Port6 Data Register
Bits7-0: P6.[7:0]: Port6 Output Latch Bits.
Write - Output appears on I/O pins.
0: Logic Low Output.
1: Logic High Output (Open-Drain if corresponding P74OUT bit = 0). See Figure 17.20.
Read - Returns states of I/O pins.
0: P6.n pin is logic low.
1: P6.n pin is logic high.
Note: P6.[7:0] can be driven by the External Data Memory Interface (as Address[15:8] in Multiplexed
mode, or as Address[7:0] in Non-multiplexed mode). See Section 16. EXTERNAL DATA MEM-
ORY INTERFACE AND ON-CHIP XRAM on page 145 for more information about the External
Memory Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P6.7 P6.6 P6.5 P6.4 P6.3 P6.2 P6.1 P6.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x86
Figure 17.24. P7: Port7 Data Register
Bits7-0: P7.[7:0]: Port7 Output Latch Bits.
Write - Output appears on I/O pins.
0: Logic Low Output.
1: Logic High Output (Open-Drain if corresponding P74OUT bit = 0). See Figure 17.20.
Read - Returns states of I/O pins.
0: P7.n pin is logic low.
1: P7.n pin is logic high.
Note: P7.[7:0] can be driven by the External Data Memory Interface (as AD[7:0] in Multiplexed mode, or
as D[7:0] in Non-multiplexed mode). See Section 16. EXTERNAL DATA MEMORY INTER-
FACE AND ON-CHIP XRAM on page 145 for more information about the External Memory
Interface.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
P7.7 P7.6 P7.5 P7.4 P7.3 P7.2 P7.1 P7.0 11111111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x96
C8051F020/1/2/3
182 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 183
18. SYSTEM MANAGEMENT BUS / I
2
C BUS (SMBUS0)
The SMBus0 I/O interface is a two-wire, bi-directional serial bus. SMBus0 is compliant with the System Manage-
ment Bus Specification, version 1.1, and compatible with the I
2
C serial bus. Reads and writes to the interface by the
system controller are byte oriented with the SMBus0 interface autonomously controlling the serial transfer of the
data. Data can be transferred at up to 1/8th of the system clock if desired (this can be faster than allowed by the
SMBus specification, depending on the system clock used). A method of extending the clock-low duration is avail-
able to accommodate devices with different speed capabilities on the same bus.
SMBus0 may operate as a master and/or slave, and may function on a bus with multiple masters. SMBus0 provides
control of SDA (serial data), SCL (serial clock) generation and synchronization, arbitration logic, and START/STOP
control and generation. SMBus0 is controlled by SFRs as described in Section 18.4 on page 189.
Figure 18.1. SMBus0 Block Diagram
SFR Bus
Data Path
Control
SFR Bus
Write to
SMB0DAT
SMBUS CONTROL LOGIC
Read
SMB0DAT
SMB0ADR
S
L
V
6
G
C
S
L
V
5
S
L
V
4
S
L
V
3
S
L
V
2
S
L
V
1
S
L
V
0
C
R
O
S
S
B
A
R
Clock Divide
Logic
SYSCLK
SMB0CR
C
R
7
C
R
6
C
R
5
C
R
4
C
R
3
C
R
2
C
R
1
C
R
0
SCL
FILTER
N
SDA
Control
0000000b
7 MSBs 8
A B
A
=
B
8
0 1 2 3 4 5 6 7
SMB0DAT
8
SMB0CN
S
T
A
S
I
A
A
F
T
E
T
O
E
E
N
S
M
B
B
U
S
Y
S
T
O
SMB0STA
S
T
A
4
S
T
A
3
S
T
A
2
S
T
A
1
S
T
A
0
SCL
Control
Status Generation
Arbitration
SCL Synchronization
SCL Generation (Master Mode)
IRQ Generation
S
T
A
5
S
T
A
6
S
T
A
7
A B
A
=
B
SMBUS
IRQ
Interrupt
Request
Port I/O
1
0
SDA
FILTER
N
7
C8051F020/1/2/3
184 Rev. 1.4
Figure 18.2 shows a typical SMBus configuration. The SMBus0 interface will work at any voltage between 3.0 V and
5.0 V and different devices on the bus may operate at different voltage levels. The bi-directional SCL (serial clock)
and SDA (serial data) lines must be connected to a positive power supply voltage through a pull-up resistor or similar
circuit. Every device connected to the bus must have an open-drain or open-collector output for both the SCL and
SDA lines, so that both are pulled high when the bus is free. The maximum number of devices on the bus is limited
only by the requirement that the rise and fall times on the bus will not exceed 300 ns and 1000 ns, respectively.
18.1. Supporting Documents
It is assumed the reader is familiar with or has access to the following supporting documents:
1. The I
2
C-bus and how to use it (including specifications), Philips Semiconductor.
2. The I
2
C-Bus Specification -- Version 2.0, Philips Semiconductor.
3. System Management Bus Specification -- Version 1.1, SBS Implementers Forum.
Figure 18.2. Typical SMBus Configuration
VDD = 5V
Master
Device
Slave
Device 1
Slave
Device 2
VDD = 3V VDD = 5V VDD = 3V
SDA
SCL
C8051F020/1/2/3
Rev. 1.4 185
18.2. SMBus Protocol
Two types of data transfers are possible: data transfers from a master transmitter to an addressed slave receiver
(WRITE), and data transfers from an addressed slave transmitter to a master receiver (READ). The master device ini-
tiates both types of data transfers and provides the serial clock pulses on SCL. Note: multiple master devices on the
same bus are supported. If two or more masters attempt to initiate a data transfer simultaneously, an arbitration
scheme is employed with a single master always winning the arbitration. Note that it is not necessary to specify one
device as the master in a system; any device who transmits a START and a slave address becomes the master for that
transfer.
A typical SMBus transaction consists of a START condition followed by an address byte (Bits7-1: 7-bit slave
address; Bit0: R/W direction bit), one or more bytes of data, and a STOP condition. Each byte that is received (by a
master or slave) must be acknowledged (ACK) with a low SDA during a high SCL (see Figure 18.3). If the receiving
device does not ACK, the transmitting device will read a not acknowledge (NACK), which is a high SDA during a
high SCL.
The direction bit (R/W) occupies the least-significant bit position of the address. The direction bit is set to logic 1 to
indicate a "READ" operation and cleared to logic 0 to indicate a "WRITE" operation.
All transactions are initiated by a master, with one or more addressed slave devices as the target. The master gener-
ates the START condition and then transmits the slave address and direction bit. If the transaction is a WRITE opera-
tion from the master to the slave, the master transmits the data a byte at a time waiting for an ACK from the slave at
the end of each byte. For READ operations, the slave transmits the data waiting for an ACK from the master at the
end of each byte. At the end of the data transfer, the master generates a STOP condition to terminate the transaction
and free the bus. Figure 18.3 illustrates a typical SMBus transaction.
18.2.1. Arbitration
A master may start a transfer only if the bus is free. The bus is free after a STOP condition or after the SCL and SDA
lines remain high for a specified time (see Section 18.2.4). In the event that two or more devices attempt to begin a
transfer at the same time, an arbitration scheme is employed to force one master to give up the bus. The master
devices continue transmitting until one attempts a HIGH while the other transmits a LOW. Since the bus is open-
drain, the bus will be pulled LOW. The master attempting the HIGH will detect a LOW SDA and give up the bus. The
winning master continues its transmission without interruption; the losing master becomes a slave and receives the
rest of the transfer. This arbitration scheme is non-destructive: one device always wins, and no data is lost.
18.2.2. Clock Low Extension
SMBus provides a clock synchronization mechanism, similar to I
2
C, which allows devices with different speed capa-
bilities to coexist on the bus. A clock-low extension is used during a transfer in order to allow slower slave devices to
communicate with faster masters. The slave may temporarily hold the SCL line LOW to extend the clock low period,
effectively decreasing the serial clock frequency.
SLA6
SDA
SLA5-0 R/W D7 D6-0
SCL
Slave Address + R/W Data Byte START ACK NACK STOP
Figure 18.3. SMBus Transaction
C8051F020/1/2/3
186 Rev. 1.4
18.2.3. SCL Low Timeout
If the SCL line is held low by a slave device on the bus, no further communication is possible. Furthermore, the mas-
ter cannot force the SCL line high to correct the error condition. To solve this problem, the SMBus protocol specifies
that devices participating in a transfer must detect any clock cycle held low longer than 25 ms as a timeout condi-
tion. Devices that have detected the timeout condition must reset the communication no later than 10 ms after detect-
ing the timeout condition.
18.2.4. SCL High (SMBus Free) Timeout
The SMBus specification stipulates that if the SCL and SDA lines remain high for more that 50 s, the bus is desig-
nated as free. If an SMBus device is waiting to generate a Master START, the START will be generated following a
bus free timeout.
C8051F020/1/2/3
Rev. 1.4 187
18.3. SMBus Transfer Modes
The SMBus0 interface may be configured to operate as a master and/or a slave. At any particular time, the interface
will be operating in one of the following modes: Master Transmitter, Master Receiver, Slave Transmitter, or Slave
Receiver. See Table 18.1 for transfer mode status decoding using the SMB0STA status register. The following mode
descriptions illustrate an interrupt-driven SMBus0 application; SMBus0 may alternatively be operated in polled
mode.
18.3.1. Master Transmitter Mode
Serial data is transmitted on SDA while the serial clock is output on SCL. SMBus0 generates a START condition and
then transmits the first byte containing the address of the target slave device and the data direction bit. In this case the
data direction bit (R/W) will be logic 0 to indicate a "WRITE" operation. The SMBus0 interface transmits one or
more bytes of serial data, waiting for an acknowledge (ACK) from the slave after each byte. To indicate the end of the
serial transfer, SMBus0 generates a STOP condition.
18.3.2. Master Receiver Mode
Serial data is received on SDA while the serial clock is output on SCL. The SMBus0 interface generates a START
followed by the first data byte containing the address of the target slave and the data direction bit. In this case the data
direction bit (R/W) will be logic 1 to indicate a "READ" operation. The SMBus0 interface receives serial data from
the slave and generates the clock on SCL. After each byte is received, SMBus0 generates an ACK or NACK depend-
ing on the state of the AA bit in register SMB0CN. SMBus0 generates a STOP condition to indicate the end of the
serial transfer.
A A A S W P Data Byte Data Byte SLA
S = START
P = STOP
A = ACK
W = WRITE
SLA = Slave Address
Received by SMBus
Interface
Transmitted by
SMBus Interface
Interrupt Interrupt Interrupt Interrupt
Figure 18.4. Typical Master Transmitter Sequence
Data Byte Data Byte A N A S R P SLA
S = START
P = STOP
A = ACK
N = NACK
R = READ
SLA = Slave Address
Received by SMBus
Interface
Transmitted by
SMBus Interface
Interrupt Interrupt Interrupt Interrupt
Figure 18.5. Typical Master Receiver Sequence
C8051F020/1/2/3
188 Rev. 1.4
18.3.3. Slave Transmitter Mode
Serial data is transmitted on SDA while the serial clock is received on SCL. The SMBus0 interface receives a START
followed by data byte containing the slave address and direction bit. If the received slave address matches the address
held in register SMB0ADR, the SMBus0 interface generates an ACK. SMBus0 will also ACK if the general call
address (0x00) is received and the General Call Address Enable bit (SMB0ADR.0) is set to logic 1. In this case the
data direction bit (R/W) will be logic 1 to indicate a "READ" operation. The SMBus0 interface receives the clock on
SCL and transmits one or more bytes of serial data, waiting for an ACK from the master after each byte. SMBus0
exits slave mode after receiving a STOP condition from the master.
18.3.4. Slave Receiver Mode
Serial data is received on SDA while the serial clock is received on SCL. The SMBus0 interface receives a START
followed by data byte containing the slave address and direction bit. If the received slave address matches the address
held in register SMB0ADR, the interface generates an ACK. SMBus0 will also ACK if the general call address
(0x00) is received and the General Call Address Enable bit (SMB0ADR.0) is set to logic 1. In this case the data direc-
tion bit (R/W) will be logic 0 to indicate a "WRITE" operation. The SMBus0 interface receives one or more bytes of
serial data; after each byte is received, the interface transmits an ACK or NACK depending on the state of the AA bit
in SMB0CN. SMBus0 exits Slave Receiver Mode after receiving a STOP condition from the master.
P R SLA S Data Byte Data Byte A N A
S = START
P = STOP
N = NACK
W = WRITE
SLA = Slave Address
Received by SMBus
Interface
Transmitted by
SMBus Interface
Interrupt Interrupt Interrupt
Interrupt
Figure 18.6. Typical Slave Transmitter Sequence
P W SLA S Data Byte Data Byte A A A
S = START
P = STOP
A = ACK
R = READ
SLA = Slave Address
Received by SMBus
Interface
Transmitted by
SMBus Interface
Interrupt Interrupt Interrupt
Interrupt
Figure 18.7. Typical Slave Receiver Sequence
C8051F020/1/2/3
Rev. 1.4 189
18.4. SMBus Special Function Registers
The SMBus0 serial interface is accessed and controlled through five SFRs: SMB0CN Control Register, SMB0CR
Clock Rate Register, SMB0ADR Address Register, SMB0DAT Data Register and SMB0STA Status Register. The
five special function registers related to the operation of the SMBus0 interface are described in the following sec-
tions.
18.4.1. Control Register
The SMBus0 Control register SMB0CN is used to configure and control the SMBus0 interface. All of the bits in the
register can be read or written by software. Two of the control bits are also affected by the SMBus0 hardware. The
Serial Interrupt flag (SI, SMB0CN.3) is set to logic 1 by the hardware when a valid serial interrupt condition occurs.
It can only be cleared by software. The Stop flag (STO, SMB0CN.4) is cleared to logic 0 by hardware when a STOP
condition is detected on the bus.
Setting the ENSMS flag to logic 1 enables the SMBus0 interface. Clearing the ENSMB flag to logic 0 disables the
SMBus0 interface and removes it from the bus. Momentarily clearing the ENSMB flag and then resetting it to logic 1
will reset SMBus0 communication. However, ENSMB should not be used to temporarily remove a device from the
bus since the bus state information will be lost. Instead, the Assert Acknowledge (AA) flag should be used to tempo-
rarily remove the device from the bus (see description of AA flag below).
Setting the Start flag (STA, SMB0CN.5) to logic 1 will put SMBus0 in a master mode. If the bus is free, SMBus0 will
generate a START condition. If the bus is not free, SMBus0 waits for a STOP condition to free the bus and then gen-
erates a START condition after a 5 s delay per the SMB0CR value (In accordance with the SMBus protocol, the
SMBus0 interface also considers the bus free if the bus is idle for 50 s and no STOP condition was recognized). If
STA is set to logic 1 while SMBus0 is in master mode and one or more bytes have been transferred, a repeated
START condition will be generated. To ensure proper operation, the STO bit should be explicitly cleared to 0 before
setting the STA bit to 1.
When the Stop flag (STO, SMB0CN.4) is set to logic 1 while the SMBus0 interface is in master mode, the interface
generates a STOP condition. In a slave mode, the STO flag may be used to recover from an error condition. In this
case, a STOP condition is not generated on the bus, but the SMBus hardware behaves as if a STOP condition has been
received and enters the "not addressed" slave receiver mode. Note that this simulated STOP will not cause the bus to
appear free to SMBus0. The bus will remain occupied until a STOP appears on the bus or a Bus Free Timeout occurs.
Hardware automatically clears the STO flag to logic 0 when a STOP condition is detected on the bus.
The Serial Interrupt flag (SI, SMB0CN.3) is set to logic 1 by hardware when the SMBus0 interface enters one of 27
possible states. If interrupts are enabled for the SMBus0 interface, an interrupt request is generated when the SI flag
is set. The SI flag must be cleared by software.
Important Note: If SI is set to logic 1 while the SCL line is low, the clock-low period of the serial clock will be
stretched and the serial transfer is suspended until SI is cleared to logic 0. A high level on SCL is not affected by the
setting of the SI flag.
The Assert Acknowledge flag (AA, SMB0CN.2) is used to set the level of the SDA line during the acknowledge
clock cycle on the SCL line. Setting the AA flag to logic 1 will cause an ACK (low level on SDA) to be sent during
the acknowledge cycle if the device has been addressed. Setting the AA flag to logic 0 will cause a NACK (high level
on SDA) to be sent during acknowledge cycle. After the transmission of a byte in slave mode, the slave can be tempo-
rarily removed from the bus by clearing the AA flag. The slave's own address and general call address will be
ignored. To resume operation on the bus, the AA flag must be reset to logic 1 to allow the slave's address to be recog-
nized.
C8051F020/1/2/3
190 Rev. 1.4
Setting the SMBus0 Free Timer Enable bit (FTE, SMB0CN.1) to logic 1 enables the timer in SMB0CR. When SCL
goes high, the timer in SMB0CR counts up. A timer overflow indicates a free bus timeout: if SMBus0 is waiting to
generate a START, it will do so after this timeout. The bus free period should be less than 50 s (see Figure 18.9,
SMBus0 Clock Rate Register).
When the TOE bit in SMB0CN is set to logic 1, Timer 3 is used to detect SCL low timeouts. If Timer 3 is enabled
(see Section 22.2. Timer 3 on page 240), Timer 3 is forced to reload when SCL is high, and forced to count when
SCL is low. With Timer 3 enabled and configured to overflow after 25 ms (and TOE set), a Timer 3 overflow indi-
cates a SCL low timeout; the Timer 3 interrupt service routine can then be used to reset SMBus0 communication in
the event of an SCL low timeout.
C8051F020/1/2/3
Rev. 1.4 191
Figure 18.8. SMB0CN: SMBus0 Control Register
Bit7: BUSY: Busy Status Flag.
0: SMBus0 is free
1: SMBus0 is busy
Bit6: ENSMB: SMBus Enable.
This bit enables/disables the SMBus serial interface.
0: SMBus0 disabled.
1: SMBus0 enabled.
Bit5: STA: SMBus Start Flag.
0: No START condition is transmitted.
1: When operating as a master, a START condition is transmitted if the bus is free. (If the bus is not
free, the START is transmitted after a STOP is received.) If STA is set after one or more bytes have
been transmitted or received and before a STOP is received, a repeated START condition is transmit-
ted. To ensure proper operation, the STO bit should be explicitly cleared to 0 before setting the STA
bit to 1.
Bit4: STO: SMBus Stop Flag.
0: No STOP condition is transmitted.
1: Setting STO to logic 1 causes a STOP condition to be transmitted. When a STOP condition is
received, hardware clears STO to logic 0. If both STA and STO are set, a STOP condition is transmit-
ted followed by a START condition. In slave mode, setting the STO flag causes SMBus to behave as
if a STOP condition was received.
Bit3: SI: SMBus Serial Interrupt Flag.
This bit is set by hardware when one of 27 possible SMBus0 states is entered. (Status code 0xF8 does
not cause SI to be set.) When the SI interrupt is enabled, setting this bit causes the CPU to vector to
the SMBus interrupt service routine. This bit is not automatically cleared by hardware and must be
cleared by software.
Bit2: AA: SMBus Assert Acknowledge Flag.
This bit defines the type of acknowledge returned during the acknowledge cycle on the SCL line.
0: A "not acknowledge" (high level on SDA) is returned during the acknowledge cycle.
1: An "acknowledge" (low level on SDA) is returned during the acknowledge cycle.
Bit1: FTE: SMBus Free Timer Enable Bit
0: No timeout when SCL is high
1: Timeout when SCL high time exceeds limit specified by the SMB0CR value.
Bit0: TOE: SMBus Timeout Enable Bit
0: No timeout when SCL is low.
R R/W R/W R/W R/W R/W R/W R/W Reset Value
BUSY ENSMB STA STO SI AA FTE TOE 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xC0
C8051F020/1/2/3
192 Rev. 1.4
18.4.2. Clock Rate Register
Figure 18.9. SMB0CR: SMBus0 Clock Rate Register
Bits7-0: SMB0CR.[7:0]: SMBus0 Clock Rate Preset
The SMB0CR Clock Rate register controls the frequency of the serial clock SCL in master mode. The
8-bit word stored in the SMB0CR Register preloads a dedicated 8-bit timer. The timer counts up, and
when it rolls over to 0x00, the SCL logic state toggles.
The SMB0CR setting should be bounded by the following equation , where SMB0CR is the unsigned
8-bit value in register SMB0CR, and SYSCLK is the system clock frequency in Hz:
The resulting SCL signal high and low times are given by the following equations:
Using the same value of SMB0CR from above, the Bus Free Timeout period is given in the following
equation:
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xCF
SMB0CR 288 ( ( 0.85 SYSCLK) 1.125) <
T
LOW
256 SMB0CR ( ) SYSCLK =
T
HIGH
258 SMB0CR ( ) SYSCLK 625ns + ~
T
BFT
10
256 SMB0CR ( ) 1 +
SYSCLK
----------------------------------------------------- ~
C8051F020/1/2/3
Rev. 1.4 193
18.4.3. Data Register
The SMBus0 Data register SMB0DAT holds a byte of serial data to be transmitted or one that has just been received.
Software can read or write to this register while the SI flag is set to logic 1; software should not attempt to access the
SMB0DAT register when the SMBus is enabled and the SI flag is cleared to logic 0 since the hardware may be in the
process of shifting a byte of data in or out of the register.
Data in SMB0DAT is always shifted out MSB first. After a byte has been received, the first bit of received data is
located at the MSB of SMB0DAT. While data is being shifted out, data on the bus is simultaneously being shifted in.
Therefore, SMB0DAT always contains the last data byte present on the bus. In the event of lost arbitration, the transi-
tion from master transmitter to slave receiver is made with the correct data in SMB0DAT.
18.4.4. Address Register
The SMB0ADR Address register holds the slave address for the SMBus0 interface. In slave mode, the seven most-
significant bits hold the 7-bit slave address. The least significant bit (Bit0) is used to enable the recognition of the
general call address (0x00). If Bit0 is set to logic 1, the general call address will be recognized. Otherwise, the general
call address is ignored. The contents of this register are ignored when SMBus0 is operating in master mode.
Figure 18.10. SMB0DAT: SMBus0 Data Register
Bits7-0: SMB0DAT: SMBus0 Data.
The SMB0DAT register contains a byte of data to be transmitted on the SMBus0 serial interface or a
byte that has just been received on the SMBus0 serial interface. The CPU can read from or write to
this register whenever the SI serial interrupt flag (SMB0CN.3) is set to logic 1. When the SI flag is
not set, the system may be in the process of shifting data in/out and the CPU should not attempt to
access this register.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xC2
Figure 18.11. SMB0ADR: SMBus0 Address Register
Bits7-1: SLV6-SLV0: SMBus0 Slave Address.
These bits are loaded with the 7-bit slave address to which SMBus0 will respond when operating as a
slave transmitter or slave receiver. SLV6 is the most significant bit of the address and corresponds to
the first bit of the address byte received.
Bit0: GC: General Call Address Enable.
This bit is used to enable general call address (0x00) recognition.
0: General call address is ignored.
1: General call address is recognized.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
SLV6 SLV5 SLV4 SLV3 SLV2 SLV1 SLV0 GC 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xC3
C8051F020/1/2/3
194 Rev. 1.4
18.4.5. Status Register
The SMB0STA Status register holds an 8-bit status code indicating the current state of the SMBus0 interface. There
are 28 possible SMBus0 states, each with a corresponding unique status code. The five most significant bits of the
status code vary while the three least-significant bits of a valid status code are fixed at zero when SI = 1. Therefore,
all possible status codes are multiples of eight. This facilitates the use of status codes in software as an index used to
branch to appropriate service routines (allowing 8 bytes of code to service the state or jump to a more extensive ser-
vice routine).
For the purposes of user software, the contents of the SMB0STA register is only defined when the SI flag is logic 1.
Software should never write to the SMB0STA register; doing so will yield indeterminate results. The 28 SMBus0
states, along with their corresponding status codes, are given in Table 1.1.
Figure 18.12. SMB0STA: SMBus0 Status Register
Bits7-3: STA7-STA3: SMBus0 Status Code.
These bits contain the SMBus0 Status Code. There are 28 possible status codes; each status code cor-
responds to a single SMBus state. A valid status code is present in SMB0STA when the SI flag
(SMB0CN.3) is set to logic 1. The content of SMB0STA is not defined when the SI flag is logic 0.
Writing to the SMB0STA register at any time will yield indeterminate results.
Bits2-0: STA2-STA0: The three least significant bits of SMB0STA are always read as logic 0 when the SI flag
is logic 1.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
STA7 STA6 STA5 STA4 STA3 STA2 STA1 STA0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xC1
C8051F020/1/2/3
Rev. 1.4 195
Table 18.1. SMB0STA Status Codes and States
Mode
Status
Code
SMBus State Typical Action
M
T
/
M
R
0x08 START condition transmitted. Load SMB0DAT with Slave Address +
R/W. Clear STA.
0x10 Repeated START condition transmitted. Load SMB0DAT with Slave Address +
R/W. Clear STA.
M
a
s
t
e
r
T
r
a
n
s
m
i
t
t
e
r
0x18 Slave Address + W transmitted. ACK
received.
Load SMB0DAT with data to be transmit-
ted.
0x20 Slave Address + W transmitted. NACK
received.
Acknowledge poll to retry. Set STO +
STA.
0x28 Data byte transmitted. ACK received.
1) Load SMB0DAT with next byte, OR
2) Set STO, OR
3) Clear STO then set STA for repeated
START.
0x30 Data byte transmitted. NACK received. 1) Retry transfer OR
2) Set STO.
0x38 Arbitration Lost. Save current data.
M
a
s
t
e
r
R
e
c
e
i
v
e
r
0x40 Slave Address + R transmitted. ACK received. If only receiving one byte, clear AA (send
NACK after received byte). Wait for
received data.
0x48 Slave Address + R transmitted. NACK
received.
Acknowledge poll to retry. Set STO +
STA.
0x50 Data byte received. ACK transmitted. Read SMB0DAT. Wait for next byte. If
next byte is last byte, clear AA.
0x58 Data byte received. NACK transmitted. Set STO.
C8051F020/1/2/3
196 Rev. 1.4
S
l
a
v
e
R
e
c
e
i
v
e
r
0x60 Own slave address + W received. ACK trans-
mitted.
Wait for data.
0x68 Arbitration lost in sending SLA + R/W as mas-
ter. Own address + W received. ACK transmit-
ted.
Save current data for retry when bus is
free. Wait for data.
0x70 General call address received. ACK transmit-
ted.
Wait for data.
0x78 Arbitration lost in sending SLA + R/W as mas-
ter. General call address received. ACK trans-
mitted.
Save current data for retry when bus is
free.
0x80 Data byte received. ACK transmitted. Read SMB0DAT. Wait for next byte or
STOP.
0x88 Data byte received. NACK transmitted. Set STO to reset SMBus.
0x90 Data byte received after general call address.
ACK transmitted.
Read SMB0DAT. Wait for next byte or
STOP.
0x98 Data byte received after general call address.
NACK transmitted.
Set STO to reset SMBus.
0xA0 STOP or repeated START received. No action necessary.
S
l
a
v
e
T
r
a
n
s
m
i
t
t
e
r
0xA8 Own address + R received. ACK transmitted. Load SMB0DAT with data to transmit.
0xB0 Arbitration lost in transmitting SLA + R/W as
master. Own address + R received. ACK
transmitted.
Save current data for retry when bus is
free. Load SMB0DAT with data to trans-
mit.
0xB8 Data byte transmitted. ACK received. Load SMB0DAT with data to transmit.
0xC0 Data byte transmitted. NACK received. Wait for STOP.
0xC8 Last data byte transmitted (AA=0). ACK
received.
Set STO to reset SMBus.
S
l
a
v
e
0xD0 SCL Clock High Timer per SMB0CR timed out Set STO to reset SMBus.
A
l
l
0x00 Bus Error (illegal START or STOP) Set STO to reset SMBus.
0xF8 Idle State does not set SI.
Table 18.1. SMB0STA Status Codes and States
Mode
Status
Code
SMBus State Typical Action
C8051F020/1/2/3
Rev. 1.4 197
19. SERIAL PERIPHERAL INTERFACE BUS (SPI0)
The Serial Peripheral Interface (SPI0) provides access to a four-wire, full-duplex, serial bus. SPI0 may operate as a
master or a slave, and supports the connection of multiple slaves and masters on the same bus. A slave-select input
(NSS) is included in the SPI0 interface to select SPI0 as a slave; additional general purpose port I/O can be used as
slave-select outputs when SPI0 is operating as a master. Collision detection is provided when two or more masters
attempt a data transfer at the same time. When the SPI is configured as a master, the maximum data transfer rate (bits/
sec) is one-half the system clock frequency.
When the SPI is configured as a slave, the maximum data transfer rate (bits/sec) for full-duplex operation is 1/10 the
system clock frequency, provided that the master issues SCK, NSS, and the serial input data synchronously with the
system clock. If the master issues SCK, NSS, and the serial input data asynchronously, the maximum data transfer
rate (bits/sec) must be less that 1/10 the system clock frequency. In the special case where the master only wants to
transmit data to the slave and does not need to receive data from the slave (i.e. half-duplex operation), the SPI slave
can receive data at a maximum data transfer rate (bits/sec) of 1/4 the system clock frequency. This is provided that the
master issues SCK, NSS, and the serial input data synchronously with the system clock.
Figure 19.1. SPI Block Diagram
SFR Bus
Clock Divide
Logic
Data Path
Control
SFR Bus
Write to
SPI0DAT
Receive Data Register
SPI0DAT
0 1 2 3 4 5 6 7
Shift Register
SPI CONTROL LOGIC
Bit Count
Logic
SPI0CKR
S
C
R
7
S
C
R
6
S
C
R
5
S
C
R
4
S
C
R
3
S
C
R
2
S
C
R
1
S
C
R
0
SPI0CFG
C
K
P
H
A
C
K
P
O
L
B
C
2
B
C
1
B
C
0
F
R
S
2
F
R
S
1
F
R
S
0
SPI0CN
M
O
D
F
T
X
B
S
Y
S
L
V
S
E
L
M
S
T
E
N
S
P
I
E
N
W
C
O
L
S
P
I
F
R
X
O
V
R
N
Pin Control
Interface
SPI Clock
(Master Mode)
Pin
Control
Logic
C
R
O
S
S
B
A
R
Port I/O
Read
SPI0DAT
SPI IRQ
SYSCLK
Tx Data
Rx Data
SCK
MOSI
MISO
NSS
C8051F020/1/2/3
198 Rev. 1.4
19.1. Signal Descriptions
The four signals used by SPI0 (MOSI, MISO, SCK, NSS) are described below.
19.1.1. Master Out, Slave In (MOSI)
The master-out, slave-in (MOSI) signal is an output from a master device and an input to slave devices. It is used to
serially transfer data from the master to the slave. This signal is an output when SPI0 is operating as a master, and an
input when SPI0 is operating as a slave. Data is transferred most-significant bit first.
19.1.2. Master In, Slave Out (MISO)
The master-in, slave-out (MISO) signal is an output from a slave device and an input to the master device. It is used
to serially transfer data from the slave to the master. This signal is an input when SPI0 is operating as a master, and an
output when SPI0 is operating as a slave. Data is transferred most-significant bit first. A SPI slave places the MISO
pin in a high-impedance state when the slave is not selected.
19.1.3. Serial Clock (SCK)
The serial clock (SCK) signal is an output from the master device and an input to slave devices. It is used to synchro-
nize the transfer of data between the master and slave on the MOSI and MISO lines. SPI0 generates this signal when
operating as a master.
19.1.4. Slave Select (NSS)
The slave select (NSS) signal is an input used to select SPI0 as a slave, or to disable SPI0 as a master. Note that the
NSS signal is always an input to SPI0; with SPI0 operating as a master, slave select signals must be output via general
purpose port I/O pins. See Figure 19.2 for a typical configuration; see Section 17.1. Ports 0 through 3 and the Pri-
ority Crossbar Decoder on page 163 for general purpose port configuration.
The NSS signal must be low to initiate a transfer with SPI0 as a slave; SPI0 will exit slave mode when NSS is
released high. Note that received data is not latched into the receive buffer until NSS is high. For multiple-byte trans-
fers, NSS must be released high for at least 4 system clocks following each byte that is received by the SPI0 slave.
Figure 19.2. Typical SPI Interconnection
Slave
Device
Slave
Device
Master
Device
MOSI
Slave
Device
NSS NSS
MISO
SCK
NSS
VDD
GPIO
MISO
MOSI
SCK
C8051F020/1/2/3
Rev. 1.4 199
19.2. SPI0 Operation
Only a SPI master device can initiate a data transfer. SPI0 is placed in master mode by setting the Master Enable flag
(MSTEN, SPI0CN.1). Writing a byte of data to the SPI0 data register (SPI0DAT) when in Master Mode starts a data
transfer. The SPI0 master immediately shifts out the data serially on the MOSI line while providing the serial clock
on SCK. The SPIF (SPI0CN.7) flag is set to logic 1 at the end of the transfer. If interrupts are enabled, an interrupt
request is generated when the SPIF flag is set. The SPI0 master can be configured to shift in/out from one to eight bits
in a transfer operation in order to accommodate slave devices with different word lengths. The SPIFRS bits in the
SP0I Configuration Register (SPI0CFG.[2:0]) are used to select the number of bits to shift in/out in a transfer opera-
tion.
While the SPI0 master transfers data to a slave on the MOSI line, the addressed SPI slave device simultaneously
transfers the contents of its shift register to the SPI master on the MISO line in a full-duplex operation. The data byte
received from the slave replaces the data in the master's data register. Therefore, the SPIF flag serves as both a trans-
mit-complete and receive-data-ready flag. The data transfer in both directions is synchronized with the serial clock
generated by the master. Figure 19.3 illustrates the full-duplex operation of an SPI master and an addressed slave.
When SPI0 is enabled and not configured as a master, it will operate as an SPI slave. Another SPI device acting as a
master will initiate a transfer by driving the NSS input signal low. The master then shifts data out of the shift register
on the MOSI pin using the its serial clock. The SPIF flag is set to logic 1 when the NSS signal goes high, indicating
the end of a data transfer. Note that following a rising edge on NSS, the receive buffer will always contain the last
8 bits of data in the slave shift register. The slave can load its shift register for the next data transfer by writing to the
SPI0 data register. The slave must make the write to the data register at least one SPI serial clock cycle before the
master starts the next transmission. Otherwise, the byte of data already in the slave's shift register will be transferred.
Note that the NSS signal must be driven low at least 2 system clocks before the first active edge of SCK for each byte
transfer.
The SPI0 data register is double buffered on reads, but not on writes. If a write to SPI0DAT is attempted during a data
transfer, the WCOL flag (SPI0CN.6) will be set to logic 1 and the write will be ignored. The current data transfer will
continue uninterrupted. A read of the SPI0 data register by the system controller actually reads the receive buffer. The
receive overrun flag (RXOVRN in register SPI0CN) is set anytime a SPI0 slave detects a rising edge on NSS while
the receive buffer still holds unread data from a previous transfer. The new data is not transferred to the receive buf-
fer, allowing the previously received data byte to be read. The data byte causing the overrun is lost.
Figure 19.3. Full Duplex Operation
Receive Buffer
0 1 2 3 4 5 6 7
SPI SHIFT REGISTER
SLAVE DEVICE
MOSI
MISO
NSS
Receive Buffer
0 1 2 3 4 5 6 7
SPI SHIFT REGISTER
MASTER DEVICE
MOSI
MISO
NSS
VDD
Baud Rate
Generator
SCK SCK
Px.y
C8051F020/1/2/3
200 Rev. 1.4
Multiple masters may reside on the same bus. A Mode Fault flag (MODF, SPI0CN.5) is set to logic 1 when SPI0 is
configured as a master (MSTEN = 1) and its slave select signal NSS is pulled low. When the Mode Fault flag is set,
the MSTEN and SPIEN bits of the SPI control register are cleared by hardware, thereby placing the SPI0 module in
an "off-line" state. In a multiple-master environment, the system controller should check the state of the SLVSEL flag
(SPI0CN.2) to ensure the bus is free before setting the MSTEN bit and initiating a data transfer.
19.3. Serial Clock Timing
As shown in Figure 19.4, four combinations of serial clock phase and polarity can be selected using the clock control
bits in the SPI0 Configuration Register (SPI0CFG). The CKPHA bit (SPI0CFG.7) selects one of two clock phases
(edge used to latch the data). The CKPOL bit (SPI0CFG.6) selects between an active-high or active-low clock. Both
master and slave devices must be configured to use the same clock phase and polarity. Note: SPI0 should be disabled
(by clearing the SPIEN bit, SPI0CN.0) while changing the clock phase and polarity.
The SPI0 Clock Rate Register (SPI0CKR) as shown in Figure 19.7 controls the master mode serial clock frequency.
This register is ignored when operating in slave mode.
Figure 19.4. Data/Clock Timing Diagram
MISO/MOSI
NSS
SCK
(CKPOL=0, CKPHA=0)
SCK
(CKPOL=0, CKPHA=1)
SCK
(CKPOL=1, CKPHA=0)
SCK
(CKPOL=1, CKPHA=1)
MSB Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
C8051F020/1/2/3
Rev. 1.4 201
19.4. SPI Special Function Registers
SPI0 is accessed and controlled through four special function registers in the system controller: SPI0CN Control Reg-
ister, SPI0DAT Data Register, SPI0CFG Configuration Register, and SPI0CKR Clock Rate Register. The four special
function registers related to the operation of the SPI0 Bus are described in the following section.
Figure 19.5. SPI0CFG: SPI0 Configuration Register
Bit7: CKPHA: SPI0 Clock Phase.
This bit controls the SPI0 clock phase.
0: Data sampled on first edge of SCK period.
1: Data sampled on second edge of SCK period.
Bit6: CKPOL: SPI0 Clock Polarity.
This bit controls the SPI0 clock polarity.
0: SCK line low in idle state.
1: SCK line high in idle state.
Bits5-3: BC2-BC0: SPI0 Bit Count.
Indicates which of the up to 8 bits of the SPI0 word have been transmitted.
Bits2-0: SPIFRS2-SPIFRS0: SPI0 Frame Size.
These three bits determine the number of bits to shift in/out of the SPI0 shift register during a data
transfer in master mode. They are ignored in slave mode.
R/W R/W R R R R/W R/W R/W Reset Value
CKPHA CKPOL BC2 BC1 BC0 SPIFRS2 SPIFRS1 SPIFRS0 00000111
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x9A
BC2-BC0 BIT Transmitted
0 0 0 Bit 0 (LSB)
0 0 1 Bit 1
0 1 0 Bit 2
0 1 1 Bit 3
1 0 0 Bit 4
1 0 1 Bit 5
1 1 0 Bit 6
1 1 1 Bit 7 (MSB)
SPIFRS Bits Shifted
0 0 0 1
0 0 1 2
0 1 0 3
0 1 1 4
1 0 0 5
1 0 1 6
1 1 0 7
1 1 1 8
C8051F020/1/2/3
202 Rev. 1.4
Figure 19.6. SPI0CN: SPI0 Control Register
Bit7: SPIF: SPI0 Interrupt Flag.
This bit is set to logic 1 by hardware at the end of a data transfer. If interrupts are enabled, setting this
bit causes the CPU to vector to the SPI0 interrupt service routine. This bit is not automatically cleared
by hardware. It must be cleared by software.
Bit6: WCOL: Write Collision Flag.
This bit is set to logic 1 by hardware (and generates a SPI0 interrupt) to indicate a write to the SPI0
data register was attempted while a data transfer was in progress. If interrupts are enabled, setting this
bit causes the CPU to vector to the SPI0 interrupt service routine. This bit is not automatically cleared
by hardware. It must be cleared by software.
Bit5: MODF: Mode Fault Flag.
This bit is set to logic 1 by hardware (and generates a SPI0 interrupt) when a master mode collision is
detected (NSS is low and MSTEN = 1). If interrupts are enabled, setting this bit causes the CPU to
vector to the SPI0 interrupt service routine. This bit is not automatically cleared by hardware. It must
be cleared by software.
Bit4: RXOVRN: Receive Overrun Flag.
This bit is set to logic 1 by hardware (and generates a SPI0 interrupt) when the receive buffer still
holds unread data from a previous transfer and the last bit of the current transfer is shifted into the
SPI0 shift register. If interrupts are enabled, setting this bit causes the CPU to vector to the SPI0 inter-
rupt service routine. This bit is not automatically cleared by hardware. It must be cleared by software.
Bit3: TXBSY: Transmit Busy Flag.
This bit is set to logic 1 by hardware while a master mode transfer is in progress. It is cleared by hard-
ware at the end of the transfer.
Bit2: SLVSEL: Slave Selected Flag.
This bit is set to logic 1 whenever the NSS pin is low indicating it is enabled as a slave. It is cleared to
logic 0 when NSS is high (slave disabled).
Bit1: MSTEN: Master Mode Enable.
0: Disable master mode. Operate in slave mode.
1: Enable master mode. Operate as a master.
Bit0: SPIEN: SPI0 Enable.
This bit enables/disables the SPI.
0: SPI disabled.
R/W R/W R/W R/W R R R/W R/W Reset Value
SPIF WCOL MODF RXOVRN TXBSY SLVSEL MSTEN SPIEN 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xF8
C8051F020/1/2/3
Rev. 1.4 203
Figure 19.7. SPI0CKR: SPI0 Clock Rate Register
Bits7-0: SCR7-SCR0: SPI0 Clock Rate
These bits determine the frequency of the SCK output when the SPI0 module is configured for master
mode operation. The SCK clock frequency is a divided down version of the system clock, and is
given in the following equation, where SYSCLK is the system clock frequency and SPI0CR is the 8-
bit value held in the SPI0CR register.
for 0 <= SPI0CKR <= 255
Example: If SYSCLK = 2 MHz and SPI0CKR = 0x04,
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
SCR7 SCR6 SCR5 SCR4 SCR3 SCR2 SCR1 SCR0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x9D
f
SCK
SYSCLK
2 SPI0CKR 1 + ( )
------------------------------------------------- =
f
SCK
2000000
2 4 1 + ( )
-------------------------- =
f
SCK
200kHz =
Figure 19.8. SPI0DAT: SPI0 Data Register
Bits7-0: SPI0DAT: SPI0 Transmit and Receive Data.
The SPI0DAT register is used to transmit and receive SPI0 data. Writing data to SPI0DAT places the
data immediately into the shift register and initiates a transfer when in Master Mode. A read of
SPI0DAT returns the contents of the receive buffer.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x9B
C8051F020/1/2/3
204 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 205
20. UART0
UART0 is an enhanced serial port with frame error detection and address recognition hardware. UART0 may operate
in full-duplex asynchronous or half-duplex synchronous modes, and mutiproccessor communication is fully sup-
ported. Receive data is buffered in a holding register, allowing UART0 to start reception of a second incoming data
byte before software has finished reading the previous data byte. A Receive Overrun bit indicates when new received
data is latched into the receive buffer before the previous received byte is read.
UART0 is accessed via its associated SFRs, Serial Control (SCON0) and Serial Data Buffer (SBUF0). The single
SBUF0 location provides access to both transmit and receive registers. Reads access the Receive register and writes
access the Transmit register automatically.
UART0 may be operated in polled or interrupt mode. UART0 has two sources of interrupts: a Transmit Interrupt flag,
TI0 (SCON0.1) set when transmission of a data byte is complete, and a Receive Interrupt flag, RI0 (SCON0.0) set
when reception of a data byte is complete. UART0 interrupt flags are not cleared by hardware when the CPU vectors
to the interrupt service routine; they must be cleared manually by software. This allows software to determine the
cause of the UART0 interrupt (transmit complete or receive complete).
Figure 20.1. UART0 Block Diagram
Tx Control
Tx Clock
Tx IRQ
Zero Detector
Send
Shift
SET
Q D
CLR
Stop Bit
Gen.
TB8
Start
Data
Write to
SBUF
Crossbar
TX
Port I/O
Serial Port
(UART0/1)
Interrupt
TI
RI
SCON
S
M
2
T
B
8
R
B
8
T
I
R
I
S
M
1
S
M
0
R
E
N
Rx Control
Start
Rx Clock Load
SBUF
0x1FF Shift
EN Rx IRQ
UART
Baud Rate
Generation
Logic
SFR Bus
Input Shift Register
(9 bits)
Frame Error
Detection
SBUF
(Receive Latch)
Read
SBUF
SFR Bus
SADDR
SADEN
Match Detect
RB8 Load SBUF
Crossbar
RX
SBUF
(Transmit Shift)
Address
Match
C8051F020/1/2/3
206 Rev. 1.4
20.1. UART0 Operational Modes
UART0 provides four operating modes (one synchronous and three asynchronous) selected by setting configuration
bits in the SCON0 register. These four modes offer different baud rates and communication protocols. The four
modes are summarized in Table 20.1.
20.1.1. Mode 0: Synchronous Mode
Mode 0 provides synchronous, half-duplex communication. Serial data is transmitted and received on the RX0 pin.
The TX0 pin provides the shift clock for both transmit and receive. The MCU must be the master since it generates
the shift clock for transmission in both directions (see the interconnect diagram in Figure 20.2).
Data transmission begins when an instruction writes a data byte to the SBUF0 register. Eight data bits are transferred
LSB first (see the timing diagram in Figure 20.3), and the TI0 Transmit Interrupt Flag (SCON0.1) is set at the end of
the eighth bit time. Data reception begins when the REN0 Receive Enable bit (SCON0.4) is set to logic 1 and the RI0
Receive Interrupt Flag (SCON0.0) is cleared. One cycle after the eighth bit is shifted in, the RI0 flag is set and recep-
tion stops until software clears the RI0 bit. An interrupt will occur if enabled when either TI0 or RI0 are set.
The Mode 0 baud rate is SYSCLK / 12. RX0 is forced to open-drain in Mode 0, and an external pull-up will typically
be required.
Table 20.1. UART0 Modes
Mode Synchronization Baud Clock Data Bits Start/Stop Bits
0 Synchronous SYSCLK / 12 8 None
1 Asynchronous Timer 1 or 2 Overflow 8 1 Start, 1 Stop
2 Asynchronous SYSCLK / 32 or SYSCLK / 64 9 1 Start, 1 Stop
3 Asynchronous Timer 1 or 2 Overflow 9 1 Start, 1 Stop
Figure 20.2. UART0 Mode 0 Interconnect
Shift
Reg.
CLK
C8051Fxxx
RX
TX
DATA
8 Extra Outputs
Figure 20.3. UART0 Mode 0 Timing Diagram
D0
MODE 0 RECEIVE
RX (data in)
D1 D2 D3 D4 D5 D6 D7
TX (clk out)
D1 D0 D2 D3 D4 D5 D6 D7
RX (data out)
MODE 0 TRANSMIT
TX (clk out)
C8051F020/1/2/3
Rev. 1.4 207
20.1.2. Mode 1: 8-Bit UART, Variable Baud Rate
Mode 1 provides standard asynchronous, full duplex communication using a total of 10 bits per data byte: one start
bit, eight data bits (LSB first), and one stop bit. Data are transmitted from the TX0 pin and received at the RX0 pin.
On receive, the eight data bits are stored in SBUF0 and the stop bit goes into RB80 (SCON0.2).
Data transmission begins when an instruction writes a data byte to the SBUF0 register. The TI0 Transmit Interrupt
Flag (SCON0.1) is set at the end of the transmission (the beginning of the stop-bit time). Data reception can begin
any time after the REN0 Receive Enable bit (SCON0.4) is set to logic 1. After the stop bit is received, the data byte
will be loaded into the SBUF0 receive register if the following conditions are met: RI0 must be logic 0, and if SM20
is logic 1, the stop bit must be logic 1.
If these conditions are met, the eight bits of data are stored in SBUF0, the stop bit is stored in RB80 and the RI0 flag
is set. If these conditions are not met, SBUF0 and RB80 will not be loaded and the RI0 flag will not be set. An inter-
rupt will occur if enabled when either TI0 or RI0 is set.
The baud rate generated in Mode 1 is a function of timer overflow, shown in Equation 20.1 and Equation 20.2.
UART0 can use Timer 1 operating in 8-Bit Auto-Reload Mode, or Timer 2 operating in Baud Rate Generator Mode to
generate the baud rate (note that the TX and RX clocks are selected separately). On each timer overflow event (a roll-
over from all ones - (0xFF for Timer 1, 0xFFFF for Timer 2) - to zero) a clock is sent to the baud rate logic.
Timer 2 is selected as TX and/or RX baud clock source by setting the TCLK0 (T2CON.4) and/or RCLK0 (T2CON.5)
bits, respectively (see Section 22. TIMERS on page 225 for complete timer configuration details). When either
TCLK0 or RCLK0 is set to logic 1, Timer 2 is forced into Baud Rate Generator Mode, with SYSCLK / 2 as its clock
source. If TCLK0 and/or RCLK0 is logic 0, Timer 1 acts as the baud clock source for the TX and/or RX circuits,
respectively.
The Mode 1 baud rate equations are shown below, where T1M is the Timer 1 Clock Select bit (register CKCON),
TH1 is the 8-bit reload register for Timer 1, SMOD0 is the UART0 baud rate doubler (register PCON) and
[RCAP2H , RCAP2L] is the 16-bit reload register for Timer 2.
Figure 20.4. UART0 Mode 1 Timing Diagram
D1 D0 D2 D3 D4 D5 D6 D7
START
BIT
MARK
STOP
BIT
BIT TIMES
BIT SAMPLING
SPACE
Equation 20.1. Mode 1 Baud Rate using Timer 1
BaudRate
2
SMOD0
32
-------------------
\ .
| |
SYSCLK 12
T1M 1) ( )
256 TH1 ( )
--------------------------------------------------------
\ .
| |
=
Equation 20.2. Mode 1 Baud Rate using Timer 2
BaudRate
SYSCLK
32 65536 RCAP2H RCAP2L [ , ] ( )
--------------------------------------------------------------------------------------------- =
C8051F020/1/2/3
208 Rev. 1.4
20.1.3. Mode 2: 9-Bit UART, Fixed Baud Rate
Mode 2 provides asynchronous, full-duplex communication using a total of eleven bits per data byte: a start bit, 8 data
bits (LSB first), a programmable ninth data bit, and a stop bit. Mode 2 supports multiprocessor communications and
hardware address recognition (see Section 20.2. Multiprocessor Communications on page 210). On transmit,
the ninth data bit is determined by the value in TB80 (SCON0.3). It can be assigned the value of the parity flag P in
the PSW or used in multiprocessor communications. On receive, the ninth data bit goes into RB80 (SCON0.2) and
the stop bit is ignored.
Data transmission begins when an instruction writes a data byte to the SBUF0 register. The TI0 Transmit Interrupt
Flag (SCON0.1) is set at the end of the transmission (the beginning of the stop-bit time). Data reception can begin
any time after the REN0 Receive Enable bit (SCON0.4) is set to logic 1. After the stop bit is received, the data byte
will be loaded into the SBUF0 receive register if RI0 is logic 0 and one of the following requirements are met:
1. SM20 is logic 0
2. SM20 is logic 1, the received 9th bit is logic 1, and the received address matches the UART0 address as
described in Section 20.2.
If the above conditions are satisfied, the eight bits of data are stored in SBUF0, the ninth bit is stored in RB80 and the
RI0 flag is set. If these conditions are not met, SBUF0 and RB80 will not be loaded and the RI0 flag will not be set.
An interrupt will occur if enabled when either TI0 or RI0 is set.
The baud rate in Mode 2 is either SYSCLK / 32 or SYSCLK / 64, depending on the value of the SMOD0 bit in regis-
ter PCON.
Equation 20.3. Mode 2 Baud Rate
BaudRate 2
SMOD0 SYSCLK
64
----------------------
\ .
| |
=
Figure 20.5. UART Modes 2 and 3 Timing Diagram
D1 D0 D2 D3 D4 D5 D6 D7
START
BIT
MARK
STOP
BIT
BIT TIMES
BIT SAMPLING
SPACE
D8
C8051F020/1/2/3
Rev. 1.4 209
20.1.4. Mode 3: 9-Bit UART, Variable Baud Rate
Mode 3 uses the Mode 2 transmission protocol with the Mode 1 baud rate generation. Mode 3 operation transmits
11 bits: a start bit, 8 data bits (LSB first), a programmable ninth data bit, and a stop bit. The baud rate is derived from
Timer 1 or Timer 2 overflows, as defined by Equation 20.1 and Equation 20.2. Multiprocessor communications and
hardware address recognition are supported, as described in Section 20.2.
Figure 20.6. UART Modes 1, 2, and 3 Interconnect Diagram
OR
RS-232
C8051Fxxx
RS-232
LEVEL
XLTR
TX
RX
C8051Fxxx
RX
TX
MCU
RX
TX
C8051F020/1/2/3
210 Rev. 1.4
20.2. Multiprocessor Communications
Modes 2 and 3 support multiprocessor communication between a master processor and one or more slave processors
by special use of the ninth data bit and the built-in UART0 address recognition hardware. A master processor begins
a transfer with an address byte to select one or more target slave devices. An address byte differs from a data byte in
that its ninth bit is logic 1; in a data byte, the ninth bit is always set to logic 0.
The UART0 address is configured via two SFRs: SADDR0 (Serial Address) and SADEN0 (Serial Address Enable).
SADEN0 sets the bit mask for the address held in SADDR0: bits set to logic 1 in SADEN0 correspond to bits in
SADDR0 that are checked against the received address byte; bits set to logic 0 in SADEN0 correspond to dont
care bits in SADDR0.
Setting the SM20 bit (SCON0.5) configures UART0 such that when a stop bit is received, UART0 will generate an
interrupt only if the ninth bit is logic 1 (RB80 = 1) and the received data byte matches the UART0 slave address. Fol-
lowing the received address interrupt, the slave should clear its SM20 bit to enable interrupts on the reception of the
following data byte(s). Once the entire message is received, the addressed slave should reset its SM20 bit to ignore all
transmissions until it receives the next address byte. While SM20 is logic 1, UART0 ignores all bytes that do not
match the UART0 address and include a ninth bit that is logic 1.
Multiple addresses can be assigned to a single slave and/or a single address can be assigned to multiple slaves,
thereby enabling "broadcast" transmissions to more than one slave simultaneously. The broadcast address is the logi-
cal OR of registers SADDR0 and SADEN0, and 0s of the result are treated as dont cares. Typically a broadcast
address of 0xFF (hexadecimal) is acknowledged by all slaves, assuming dont care bits as 1s. The master proces-
sor can be configured to receive all transmissions or a protocol can be implemented such that the master/slave role is
temporarily reversed to enable half-duplex transmission between the original master and slave(s).
Example 1 Example 2 Example 3
SADDR0 = 00110101 SADDR0 = 00110101 SADDR0 = 00110101
SADEN0 = 00001111 SADEN0 = 11110011 SADEN0 = 11000000
UART0 Address = xxxx0101 UART0 Address = 0011xx01 UART0 Address = 00xxxxxx
Figure 20.7. UART Multi-Processor Mode Interconnect Diagram
Master
Device
Slave
Device
TX RX RX TX
Slave
Device
RX TX
Slave
Device
RX TX
+5V
C8051F020/1/2/3
Rev. 1.4 211
20.3. Frame and Transmission Error Detection
Frame error detection is available in the following modes when the SSTAT0 bit in register PCON is set to logic 1.
Note: The SSTAT0 bit must be logic 1 to access any of the status bits (FE0, RXOVR0, and TXCOL0). To access the
UART0 Mode Select bits (SM00, SM10, and SM20), the SSTAT0 bit must be logic 0.
All Modes:
The Transmit Collision bit (TXCOL0 bit in register SCON0) reads 1 if user software writes data to the SBUF0 reg-
ister while a transmit is in progress. Note that the TXCOL0 bit also functions as the SM20 bit when the SSTAT0 bit in
register PCON is logic 0.
Modes 1, 2, and 3:
The Receive Overrun bit (RXOVR0 in register SCON0) reads 1 if a new data byte is latched into the receive buffer
before software has read the previous byte. Note that the RXOVR0 bit also functions as the SM10 bit when the
SSTAT0 bit in register PCON is logic 0.
The Frame Error bit (FE0 in register SCON0) reads 1 if an invalid (low) STOP bit is detected. Note that the FE0 bit
also functions as the SM00 bit when the SSTAT0 bit in register PCON is logic 0.
C8051F020/1/2/3
212 Rev. 1.4
Table 20.2. Oscillator Frequencies for Standard Baud Rates
Oscillator frequency (MHz) Divide Factor Timer 1 Load Value* Resulting Baud Rate (Hz)**
25.0 434 0xE5 57600 (57870)
25.0 868 0xCA 28800
24.576 320 0xEC 76800
24.576 848 0xCB 28800 (28921)
24.0 208 0XF3 115200 (115384)
24.0 833 0xCC 28800 (28846)
23.592 205 0xF3 115200 (113423)
23.592 819 0xCD 28800 (28911)
22.1184 192 0xF4 115200
22.1184 768 0xD0 28800
18.432 160 0xF6 115200
18.432 640 0xD8 28800
16.5888 144 0xF7 115200
16.5888 576 0xDC 28800
14.7456 128 0xF8 115200
14.7456 512 0xE0 28800
12.9024 112 0xF9 115200
12.9024 448 0xE4 28800
11.0592 96 0xFA 115200
11.0592 348 0xE8 28800
9.216 80 0xFB 115200
9.216 320 0xEC 28800
7.3728 64 0xFC 115200
7.3728 256 0xF0 28800
5.5296 48 0xFD 115200
5.5296 192 0xF4 28800
3.6864 32 0xFE 115200
3.6864 128 0xF8 28800
1.8432 16 0xFF 115200
1.8432 64 0xFC 28800
* Assumes SMOD0=1 and T1M=1.
** Numbers in parenthesis show the actual baud rate.
C8051F020/1/2/3
Rev. 1.4 213
Figure 20.8. SCON0: UART0 Control Register
Bits7-6: The function of these bits is determined by the SSTAT0 bit in register PCON.
If SSTAT0 is logic 1, these bits are UART0 status indicators as described in Section 20.3.
If SSTAT0 is logic 0, these bits select the Serial Port Operation Mode as shown below.
SM00-SM10: Serial Port Operation Mode:
Bit5: SM20: Multiprocessor Communication Enable.
If SSTAT0 is logic 1, this bit is a UART0 status indicator as described in Section 20.3.
If SSTAT0 is logic 0, the function of this bit is dependent on the Serial Port Operation Mode.
Mode 0: No effect.
Mode 1: Checks for valid stop bit.
0: Logic level of stop bit is ignored.
1: RI0 will only be activated if stop bit is logic level 1.
Modes 2 and 3: Multiprocessor Communications Enable.
0: Logic level of ninth bit is ignored.
1: RI0 is set and an interrupt is generated only when the ninth bit is logic 1 and the received
address matches the UART0 address or the broadcast address.
Bit4: REN0: Receive Enable.
This bit enables/disables the UART0 receiver.
0: UART0 reception disabled.
1: UART0 reception enabled.
Bit3: TB80: Ninth Transmission Bit.
The logic level of this bit will be assigned to the ninth transmission bit in Modes 2 and 3. It is not used
in Modes 0 and 1. Set or cleared by software as required.
Bit2: RB80: Ninth Receive Bit.
The bit is assigned the logic level of the ninth bit received in Modes 2 and 3. In Mode 1, if SM20 is
logic 0, RB80 is assigned the logic level of the received stop bit. RB8 is not used in Mode 0.
Bit1: TI0: Transmit Interrupt Flag.
Set by hardware when a byte of data has been transmitted by UART0 (after the 8th bit in Mode 0, or
at the beginning of the stop bit in other modes). When the UART0 interrupt is enabled, setting this bit
causes the CPU to vector to the UART0 interrupt service routine. This bit must be cleared manually
by software
Bit0: RI0: Receive Interrupt Flag.
Set by hardware when a byte of data has been received by UART0 (as selected by the SM20 bit).
When the UART0 interrupt is enabled, setting this bit causes the CPU to vector to the UART0 inter-
rupt service routine. This bit must be cleared manually by software.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
SM00/FE0 SM10/RXOV0 SM20/TXCOL0 REN0 TB80 RB80 TI0 RI0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x98
SM00 SM10 Mode
0 0 Mode 0: Synchronous Mode
0 1 Mode 1: 8-Bit UART, Variable Baud Rate
1 0 Mode 2: 9-Bit UART, Fixed Baud Rate
1 1 Mode 3: 9-Bit UART, Variable Baud Rate
C8051F020/1/2/3
214 Rev. 1.4
Figure 20.9. SBUF0: UART0 Data Buffer Register
Bits7-0: SBUF0.[7:0]: UART0 Buffer Bits 7-0 (MSB-LSB)
This SFR accesses two registers; a transmit shift register and a receive latch register. When data is
written to SBUF0, it goes to the transmit shift register and is held for serial transmission. Writing a
byte to SBUF0 is what initiates the transmission. A read of SBUF0 returns the contents of the receive
latch.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x99
Figure 20.10. SADDR0: UART0 Slave Address Register
Bits7-0: SADDR0.[7:0]: UART0 Slave Address
The contents of this register are used to define the UART0 slave address. Register SADEN0 is a bit
mask to determine which bits of SADDR0 are checked against a received address: corresponding bits
set to logic 1 in SADEN0 are checked; corresponding bits set to logic 0 are dont cares.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xA9
Figure 20.11. SADEN0: UART0 Slave Address Enable Register
Bits7-0: SADEN0.[7:0]: UART0 Slave Address Enable
Bits in this register enable corresponding bits in register SADDR0 to determine the UART0 slave
address.
0: Corresponding bit in SADDR0 is a dont care.
1: Corresponding bit in SADDR0 is checked against a received address.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xB9
C8051F020/1/2/3
Rev. 1.4 215
21. UART1
UART1 is an enhanced serial port with frame error detection and address recognition hardware. UART1 may operate
in full-duplex asynchronous or half-duplex synchronous modes, and mutiproccessor communication is fully sup-
ported. Receive data is buffered in a holding register, allowing UART1 to start reception of a second incoming data
byte before software has finished reading the previous data byte. A Receive Overrun bit indicates when new received
data is latched into the receive buffer before the previous received byte is read.
UART1 is accessed via its associated SFRs, Serial Control (SCON1) and Serial Data Buffer (SBUF1). The single
SBUF1 location provides access to both transmit and receive registers. Reads access the Receive register and writes
access the Transmit register automatically.
UART1 may be operated in polled or interrupt mode. UART1 has two sources of interrupts: a Transmit Interrupt flag,
TI1 (SCON1.1) set when transmission of a data byte is complete, and a Receive Interrupt flag, RI1 (SCON1.0) set
when reception of a data byte is complete. UART1 interrupt flags are not cleared by hardware when the CPU vectors
to the interrupt service routine; they must be cleared manually by software. This allows software to determine the
cause of the UART1 interrupt (transmit complete or receive complete).
Figure 21.1. UART1 Block Diagram
Tx Control
Tx Clock
Tx IRQ
Zero Detector
Send
Shift
SET
Q D
CLR
Stop Bit
Gen.
TB8
Start
Data
Write to
SBUF
Crossbar
TX
Port I/O
Serial Port
(UART0/1)
Interrupt
TI
RI
SCON
S
M
2
T
B
8
R
B
8
T
I
R
I
S
M
1
S
M
0
R
E
N
Rx Control
Start
Rx Clock Load
SBUF
0x1FF Shift
EN Rx IRQ
UART
Baud Rate
Generation
Logic
SFR Bus
Input Shift Register
(9 bits)
Frame Error
Detection
SBUF
(Receive Latch)
Read
SBUF
SFR Bus
SADDR
SADEN
Match Detect
RB8 Load SBUF
Crossbar
RX
SBUF
(Transmit Shift)
Address
Match
C8051F020/1/2/3
216 Rev. 1.4
21.1. UART1 Operational Modes
UART1 provides four operating modes (one synchronous and three asynchronous) selected by setting configuration
bits in the SCON1 register. These four modes offer different baud rates and communication protocols. The four
modes are summarized in Table 21.1.
21.1.1. Mode 0: Synchronous Mode
Mode 0 provides synchronous, half-duplex communication. Serial data is transmitted and received on the RX1 pin.
The TX1 pin provides the shift clock for both transmit and receive. The MCU must be the master since it generates
the shift clock for transmission in both directions (see the interconnect diagram in Figure 21.2).
Data transmission begins when an instruction writes a data byte to the SBUF1 register. Eight data bits are transferred
LSB first (see the timing diagram in Figure 21.3), and the TI1 Transmit Interrupt Flag (SCON1.1) is set at the end of
the eighth bit time. Data reception begins when the REN1 Receive Enable bit (SCON1.4) is set to logic 1 and the RI1
Receive Interrupt Flag (SCON1.0) is cleared. One cycle after the eighth bit is shifted in, the RI1 flag is set and recep-
tion stops until software clears the RI1 bit. An interrupt will occur if enabled when either TI1 or RI1 are set.
The Mode 0 baud rate is SYSCLK / 12. RX1 is forced to open-drain in Mode 0, and an external pull-up will typically
be required.
Table 21.1. UART1 Modes
Mode Synchronization Baud Clock Data Bits Start/Stop Bits
0 Synchronous SYSCLK / 12 8 None
1 Asynchronous Timer 1 or 4 Overflow 8 1 Start, 1 Stop
2 Asynchronous SYSCLK / 32 or SYSCLK / 64 9 1 Start, 1 Stop
3 Asynchronous Timer 1 or 4 Overflow 9 1 Start, 1 Stop
Figure 21.2. UART1 Mode 0 Interconnect
Shift
Reg.
CLK
C8051Fxxx
RX
TX
DATA
8 Extra Outputs
Figure 21.3. UART1 Mode 0 Timing Diagram
D0
MODE 0 RECEIVE
RX (data in)
D1 D2 D3 D4 D5 D6 D7
TX (clk out)
D1 D0 D2 D3 D4 D5 D6 D7
RX (data out)
MODE 0 TRANSMIT
TX (clk out)
C8051F020/1/2/3
Rev. 1.4 217
21.1.2. Mode 1: 8-Bit UART, Variable Baud Rate
Mode 1 provides standard asynchronous, full duplex communication using a total of 10 bits per data byte: one start
bit, eight data bits (LSB first), and one stop bit. Data are transmitted from the TX1 pin and received at the RX1 pin.
On receive, the eight data bits are stored in SBUF1 and the stop bit goes into RB81 (SCON1.2).
Data transmission begins when an instruction writes a data byte to the SBUF1 register. The TI1 Transmit Interrupt
Flag (SCON1.1) is set at the end of the transmission (the beginning of the stop-bit time). Data reception can begin
any time after the REN1 Receive Enable bit (SCON1.4) is set to logic 1. After the stop bit is received, the data byte
will be loaded into the SBUF1 receive register if the following conditions are met: RI1 must be logic 0, and if SM21
is logic 1, the stop bit must be logic 1.
If these conditions are met, the eight bits of data are stored in SBUF1, the stop bit is stored in RB81 and the RI1 flag
is set. If these conditions are not met, SBUF1 and RB81 will not be loaded and the RI1 flag will not be set. An inter-
rupt will occur if enabled when either TI1 or RI1 is set.
The baud rate generated in Mode 1 is a function of timer overflow, shown in Equation 21.1 and Equation 21.2.
UART1 can use Timer 1 operating in 8-Bit Auto-Reload Mode, or Timer 4 operating in Baud Rate Generator Mode to
generate the baud rate (note that the TX and RX clocks are selected separately). On each timer overflow event (a roll-
over from all ones - (0xFF for Timer 1, 0xFFFF for Timer 4) - to zero) a clock is sent to the baud rate logic.
Timer 4 is selected as TX and/or RX baud clock source by setting the TCLK1 (T4CON.4) and/or RCLK1 (T4CON.5)
bits, respectively (see Section 22. TIMERS on page 225 for complete timer configuration details). When either
TCLK1 or RCLK1 is set to logic 1, Timer 4 is forced into Baud Rate Generator Mode, with SYSCLK / 2 as its clock
source. If TCLK1 and/or RCLK1 is logic 0, Timer 1 acts as the baud clock source for the TX and/or RX circuits,
respectively.
The Mode 1 baud rate equations are shown below, where T1M is the Timer 1 Clock Select bit (register CKCON),
TH1 is the 8-bit reload register for Timer 1, SMOD1 is the UART1 baud rate doubler (register PCON), and
[RCAP4H , RCAP4L] is the 16-bit reload register for Timer 4.
Figure 21.4. UART1 Mode 1 Timing Diagram
D1 D0 D2 D3 D4 D5 D6 D7
START
BIT
MARK
STOP
BIT
BIT TIMES
BIT SAMPLING
SPACE
Equation 21.1. Mode 1 Baud Rate using Timer 1
BaudRate
2
SMOD1
32
-------------------
\ .
| |
SYSCLK 12
T1M 1) ( )
256 TH1 ( )
--------------------------------------------------------
\ .
| |
=
Equation 21.2. Mode 1 Baud Rate using Timer 4
BaudRate
SYSCLK
32 65536 RCAP4H RCAP4L [ , ] ( ) | |
-------------------------------------------------------------------------------------------------- =
C8051F020/1/2/3
218 Rev. 1.4
21.1.3. Mode 2: 9-Bit UART, Fixed Baud Rate
Mode 2 provides asynchronous, full-duplex communication using a total of eleven bits per data byte: a start bit, 8 data
bits (LSB first), a programmable ninth data bit, and a stop bit. Mode 2 supports multiprocessor communications and
hardware address recognition (see Section 21.2. Multiprocessor Communications on page 220). On transmit,
the ninth data bit is determined by the value in TB81 (SCON1.3). It can be assigned the value of the parity flag P in
the PSW or used in multiprocessor communications. On receive, the ninth data bit goes into RB81 (SCON1.2) and
the stop bit is ignored.
Data transmission begins when an instruction writes a data byte to the SBUF1 register. The TI1 Transmit Interrupt
Flag (SCON1.1) is set at the end of the transmission (the beginning of the stop-bit time). Data reception can begin
any time after the REN1 Receive Enable bit (SCON1.4) is set to logic 1. After the stop bit is received, the data byte
will be loaded into the SBUF1 receive register if RI1 is logic 0 and one of the following requirements are met:
1. SM21 is logic 0
2. SM21 is logic 1, the received 9th bit is logic 1, and the received address matches the UART1 address as
described in Section 21.2.
If the above conditions are satisfied, the eight bits of data are stored in SBUF1, the ninth bit is stored in RB81 and the
RI1 flag is set. If these conditions are not met, SBUF1 and RB81 will not be loaded and the RI1 flag will not be set.
An interrupt will occur if enabled when either TI1 or RI1 is set.
The baud rate in Mode 2 is either SYSCLK / 32 or SYSCLK / 64, depending on the value of the SMOD1 bit in regis-
ter PCON.
Equation 21.3. Mode 2 Baud Rate
BaudRate 2
SMOD1 SYSCLK
64
----------------------
\ .
| |
=
Figure 21.5. UART Modes 2 and 3 Timing Diagram
D1 D0 D2 D3 D4 D5 D6 D7
START
BIT
MARK
STOP
BIT
BIT TIMES
BIT SAMPLING
SPACE
D8
C8051F020/1/2/3
Rev. 1.4 219
21.1.4. Mode 3: 9-Bit UART, Variable Baud Rate
Mode 3 uses the Mode 2 transmission protocol with the Mode 1 baud rate generation. Mode 3 operation transmits
11 bits: a start bit, 8 data bits (LSB first), a programmable ninth data bit, and a stop bit. The baud rate is derived from
Timer 1 or Timer 4 overflows, as defined by Equation 21.1 and Equation 21.2. Multiprocessor communications and
hardware address recognition are supported, as described in Section 21.2.
Figure 21.6. UART Modes 1, 2, and 3 Interconnect Diagram
OR
RS-232
C8051Fxxx
RS-232
LEVEL
XLTR
TX
RX
C8051Fxxx
RX
TX
MCU
RX
TX
C8051F020/1/2/3
220 Rev. 1.4
21.2. Multiprocessor Communications
Modes 2 and 3 support multiprocessor communication between a master processor and one or more slave processors
by special use of the ninth data bit and the built-in UART1 address recognition hardware. A master processor begins
a transfer with an address byte to select one or more target slave devices. An address byte differs from a data byte in
that its ninth bit is logic 1; in a data byte, the ninth bit is always set to logic 0.
The UART1 address is configured via two SFRs: SADDR1 (Serial Address) and SADEN1 (Serial Address Enable).
SADEN1 sets the bit mask for the address held in SADDR1: bits set to logic 1 in SADEN1 correspond to bits in
SADDR1 that are checked against the received address byte; bits set to logic 0 in SADEN1 correspond to dont
care bits in SADDR1.
Setting the SM21 bit (SCON1.5) configures UART1 such that when a stop bit is received, UART1 will generate an
interrupt only if the ninth bit is logic 1 (RB81 = 1) and the received data byte matches the UART1 slave address. Fol-
lowing the received address interrupt, the slave should clear its SM21 bit to enable interrupts on the reception of the
following data byte(s). Once the entire message is received, the addressed slave should reset its SM21 bit to ignore all
transmissions until it receives the next address byte. While SM21 is logic 1, UART1 ignores all bytes that do not
match the UART1 address and include a ninth bit that is logic 1.
Multiple addresses can be assigned to a single slave and/or a single address can be assigned to multiple slaves,
thereby enabling "broadcast" transmissions to more than one slave simultaneously. The broadcast address is the logi-
cal OR of registers SADDR1 and SADEN1, and 0s of the result are treated as dont cares. Typically a broadcast
address of 0xFF (hexadecimal) is acknowledged by all slaves, assuming dont care bits as 1s. The master proces-
sor can be configured to receive all transmissions or a protocol can be implemented such that the master/slave role is
temporarily reversed to enable half-duplex transmission between the original master and slave(s).
Example 1 Example 2 Example 3
SADDR1 = 00110101 SADDR1 = 00110101 SADDR1 = 00110101
SADEN1 = 00001111 SADEN1 = 11110011 SADEN1 = 11000000
UART1 Address = xxxx0101 UART1 Address = 0011xx01 UART1 Address = 00xxxxxx
Figure 21.7. UART Multi-Processor Mode Interconnect Diagram
Master
Device
Slave
Device
TX RX RX TX
Slave
Device
RX TX
Slave
Device
RX TX
+5V
C8051F020/1/2/3
Rev. 1.4 221
21.3. Frame and Transmission Error Detection
Frame error detection is available in the following modes when the SSTAT1 bit in register PCON is set to logic 1.
Note: The SSTAT1 bit must be logic 1 to access any of the status bits (FE1, RXOVR1, and TXCOL1). To access the
UART1 Mode Select bits (SM01, SM11, and SM21), the SSTAT1 bit must be logic 0.
All Modes:
The Transmit Collision bit (TXCOL1 bit in register SCON1) reads 1 if user software writes data to the SBUF1 reg-
ister while a transmit is in progress. Note that the TXCOL1 bit also functions as the SM21 bit when the SSTAT1 bit in
register PCON is logic 0.
Modes 1, 2, and 3:
The Receive Overrun bit (RXOVR1 in register SCON1) reads 1 if a new data byte is latched into the receive buffer
before software has read the previous byte. Note that the RXOVR1 bit also functions as the SM11 bit when the
SSTAT1 bit in register PCON is logic 0.
The Frame Error bit (FE1 in register SCON1) reads 1 if an invalid (low) STOP bit is detected. Note that the FE1 bit
also functions as the SM01 bit when the SSTAT1 bit in register PCON is logic 0.
C8051F020/1/2/3
222 Rev. 1.4
Table 21.2. Oscillator Frequencies for Standard Baud Rates
Oscillator frequency (MHz) Divide Factor Timer 1 Load Value* Resulting Baud Rate (Hz)**
25.0 434 0xE5 57600 (57870)
25.0 868 0xCA 28800
24.576 320 0xEC 76800
24.576 848 0xCB 28800 (28921)
24.0 208 0XF3 115200 (115384)
24.0 833 0xCC 28800 (28846)
23.592 205 0xF3 115200 (113423)
23.592 819 0xCD 28800 (28911)
22.1184 192 0xF4 115200
22.1184 768 0xD0 28800
18.432 160 0xF6 115200
18.432 640 0xD8 28800
16.5888 144 0xF7 115200
16.5888 576 0xDC 28800
14.7456 128 0xF8 115200
14.7456 512 0xE0 28800
12.9024 112 0xF9 115200
12.9024 448 0xE4 28800
11.0592 96 0xFA 115200
11.0592 348 0xE8 28800
9.216 80 0xFB 115200
9.216 320 0xEC 28800
7.3728 64 0xFC 115200
7.3728 256 0xF0 28800
5.5296 48 0xFD 115200
5.5296 192 0xF4 28800
3.6864 32 0xFE 115200
3.6864 128 0xF8 28800
1.8432 16 0xFF 115200
1.8432 64 0xFC 28800
* Assumes SMOD1=1 and T1M=1.
** Numbers in parenthesis show the actual baud rate.
C8051F020/1/2/3
Rev. 1.4 223
Figure 21.8. SCON1: UART1 Control Register
Bits7-6: The function of these bits is determined by the SSTAT1 bit in register PCON.
If SSTAT1 is logic 1, these bits are UART1 status indicators as described in Section 21.3.
If SSTAT1 is logic 0, these bits select the Serial Port Operation Mode as shown below.
SM01-SM11: Serial Port Operation Mode:
Bit5: SM21: Multiprocessor Communication Enable.
If SSTAT1 is logic 1, this bit is a UART1 status indicator as described in Section 21.3.
If SSTAT1 is logic 0, the function of this bit is dependent on the Serial Port Operation Mode.
Mode 0: No effect.
Mode 1: Checks for valid stop bit.
0: Logic level of stop bit is ignored.
1: RI1 will only be activated if stop bit is logic level 1.
Modes 2 and 3: Multiprocessor Communications Enable.
0: Logic level of ninth bit is ignored.
1: RI1 is set and an interrupt is generated only when the ninth bit is logic 1 and the received
address matches the UART1 address or the broadcast address.
Bit4: REN1: Receive Enable.
This bit enables/disables the UART1 receiver.
0: UART1 reception disabled.
1: UART1 reception enabled.
Bit3: TB81: Ninth Transmission Bit.
The logic level of this bit will be assigned to the ninth transmission bit in Modes 2 and 3. It is not used
in Modes 0 and 1. Set or cleared by software as required.
Bit2: RB81: Ninth Receive Bit.
The bit is assigned the logic level of the ninth bit received in Modes 2 and 3. In Mode 1, if SM21 is
logic 0, RB81 is assigned the logic level of the received stop bit. RB8 is not used in Mode 0.
Bit1: TI1: Transmit Interrupt Flag.
Set by hardware when a byte of data has been transmitted by UART1 (after the 8th bit in Mode 0, or
at the beginning of the stop bit in other modes). When the UART1 interrupt is enabled, setting this bit
causes the CPU to vector to the UART1 interrupt service routine. This bit must be cleared manually
by software
Bit0: RI1: Receive Interrupt Flag.
Set by hardware when a byte of data has been received by UART1 (as selected by the SM21 bit).
When the UART1 interrupt is enabled, setting this bit causes the CPU to vector to the UART1 inter-
rupt service routine. This bit must be cleared manually by software.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
SM01/FE1 SM11/RXOV1 SM21/TXCOL1 REN1 TB81 RB81 TI1 RI1 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF1
SM01 SM11 Mode
0 0 Mode 0: Synchronous Mode
0 1 Mode 1: 8-Bit UART, Variable Baud Rate
1 0 Mode 2: 9-Bit UART, Fixed Baud Rate
1 1 Mode 3: 9-Bit UART, Variable Baud Rate
C8051F020/1/2/3
224 Rev. 1.4
Figure 21.9. SBUF1: UART1 Data Buffer Register
Bits7-0: SBUF1.[7:0]: UART1 Buffer Bits 7-0 (MSB-LSB)
This SFR accesses two registers; a transmit shift register and a receive latch register. When data is
written to SBUF1, it goes to the transmit shift register and is held for serial transmission. Writing a
byte to SBUF1 is what initiates the transmission. A read of SBUF1 returns the contents of the receive
latch.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF2
Figure 21.10. SADDR1: UART1 Slave Address Register
Bits7-0: SADDR1.[7:0]: UART1 Slave Address
The contents of this register are used to define the UART1 slave address. Register SADEN1 is a bit
mask to determine which bits of SADDR1 are checked against a received address: corresponding bits
set to logic 1 in SADEN1 are checked; corresponding bits set to logic 0 are dont cares.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF3
Figure 21.11. SADEN1: UART1 Slave Address Enable Register
Bits7-0: SADEN1.[7:0]: UART1 Slave Address Enable
Bits in this register enable corresponding bits in register SADDR1 to determine the UART1 slave
address.
0: Corresponding bit in SADDR1 is a dont care.
1: Corresponding bit in SADDR1 is checked against a received address.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xAE
C8051F020/1/2/3
Rev. 1.4 225
22. TIMERS
The C8051F020/1/2/3 devices contain 5 counter/timers: three are 16-bit counter/timers compatible with those found
in the standard 8051, and two are 16-bit auto-reload timers for use with the ADCs, SMBus, UART1, or for general
purpose use. These can be used to measure time intervals, count external events and generate periodic interrupt
requests. Timer 0 and Timer 1 are nearly identical and have four primary modes of operation. Timer 2 offers addi-
tional capabilities not available in Timers 0 and 1. Timer 3 is similar to Timer 2, but without the capture or Baud Rate
Generator modes. Timer 4 is identical to Timer 2, and can supply baud-rate generation capabilities to UART1.
When functioning as a timer, the counter/timer registers are incremented on each clock tick. Clock ticks are derived
from the system clock divided by either one or twelve as specified by the Timer Clock Select bits (T4M-T0M) in
CKCON, shown in Figure 22.1. The twelve-clocks-per-tick option provides compatibility with the older generation
of the 8051 family. Applications that require a faster timer can use the one-clock-per-tick option.
When functioning as a counter, a counter/timer register is incremented on each high-to-low transition at the selected
input pin. Events with a frequency of up to one-fourth the system clock's frequency can be counted. The input signal
need not be periodic, but it should be held at a given level for at least two full system clock cycles to ensure the level
is sampled.
Timer 0 and Timer 1: Timer 2: Timer 3: Timer 4
13-bit counter/timer
16-bit counter/timer with
auto-reload
16-bit timer with auto-
reload
16-bit counter/timer with
auto-reload
16-bit counter/timer
16-bit counter/timer with
capture
16-bit counter/timer with
capture
8-bit counter/timer with
auto-reload
Baud rate generator for
UART0
Baud rate generator for
UART1
Two 8-bit counter/timers
(Timer 0 only)
C8051F020/1/2/3
226 Rev. 1.4
Figure 22.1. CKCON: Clock Control Register
Bit7: UNUSED. Read = 0b, Write = dont care.
Bit6: T4M: Timer 4 Clock Select.
This bit controls the division of the system clock supplied to Timer 4. This bit is ignored when the
timer is in baud rate generator mode or counter mode (i.e. C/T4 = 1).
0: Timer 4 uses the system clock divided by 12.
1: Timer 4 uses the system clock.
Bit5: T2M: Timer 2 Clock Select.
This bit controls the division of the system clock supplied to Timer 2. This bit is ignored when the
timer is in baud rate generator mode or counter mode (i.e. C/T2 = 1).
0: Timer 2 uses the system clock divided by 12.
1: Timer 2 uses the system clock.
Bit4: T1M: Timer 1 Clock Select.
This bit controls the division of the system clock supplied to Timer 1.
0: Timer 1 uses the system clock divided by 12.
1: Timer 1 uses the system clock.
Bit3: T0M: Timer 0 Clock Select.
This bit controls the division of the system clock supplied to Counter/Timer 0.
0: Counter/Timer uses the system clock divided by 12.
1: Counter/Timer uses the system clock.
Bits2-0: Reserved. Read = 000b, Must Write = 000.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
- T4M T2M T1M T0M Reserved Reserved Reserved 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8E
C8051F020/1/2/3
Rev. 1.4 227
22.1. Timer 0 and Timer 1
Timer 0 and Timer 1 are accessed and controlled through SFRs. Each counter/timer is implemented as a 16-bit regis-
ter accessed as two separate bytes: a low byte (TL0 or TL1) and a high byte (TH0 or TH1). The Counter/Timer Con-
trol (TCON) register is used to enable Timer 0 and Timer 1 as well as indicate their status. Both counter/timers
operate in one of four primary modes selected by setting the Mode Select bits M1-M0 in the Counter/Timer Mode
(TMOD) register. Each timer can be configured independently. Following is a detailed description of each operating
mode.
22.1.1. Mode 0: 13-bit Counter/Timer
Timer 0 and Timer 1 operate as a 13-bit counter/timer in Mode 0. The following describes the configuration and oper-
ation of Timer 0. However, both timers operate identically and Timer 1 is configured in the same manner as described
for Timer 0.
The TH0 register holds the eight MSBs of the 13-bit counter/timer. TL0 holds the five LSBs in bit positions TL0.4-
TL0.0. The three upper bits of TL0 (TL0.7-TL0.5) are indeterminate and should be masked out or ignored when read-
ing. As the 13-bit timer register increments and overflows from 0x1FFF (all ones) to 0x0000, the timer overflow flag
TF0 (TCON.5) is set and an interrupt will occur if enabled.
The C/T0 bit (TMOD.2) selects the counter/timer's clock source. Clearing C/T selects the system clock as the input
for the timer. When C/T0 is set to logic 1, high-to-low transitions at the selected input pin (T0) increment the timer
register. (Refer to Section 17.1. Ports 0 through 3 and the Priority Crossbar Decoder on page 163 for informa-
tion on selecting and configuring external I/O pins for digital peripherals.)
Setting the TR0 bit (TCON.4) enables the timer when either GATE0 (TMOD.3) is 0 or the input signal /INT0 is
logic-level one. Setting GATE0 to logic 1 allows the timer to be controlled by the external input signal /INT0, facili-
tating pulse width measurements.
Setting TR0 does not reset the timer register. The timer register should be initialized to the desired value before
enabling the timer.
TL1 and TH1 form the 13-bit register for Timer 1 in the same manner as described above for TL0 and TH0. Timer 1
is configured and controlled using the relevant TCON and TMOD bits just as with Timer 0.
TR0 GATE0 /INT0 Counter/Timer
0 X X Disabled
1 0 X Enabled
1 1 0 Disabled
1 1 1 Enabled
X = Don't Care
C8051F020/1/2/3
228 Rev. 1.4
22.1.2. Mode 1: 16-bit Counter/Timer
Mode 1 operation is the same as Mode 0, except that the counter/timer registers use all 16 bits. The counter/timers are
enabled and configured in Mode 1 in the same manner as for Mode 0.
Figure 22.2. T0 Mode 0 Block Diagram
TCLK
TL0
(5 bits)
TH0
(8 bits)
T
C
O
N
TF0
TR0
TR1
TF1
IE1
IT1
IE0
IT0
Interrupt
/INT0 TR0
T0
Crossbar
0
1
0
1
TMOD
T
1
M
1
T
1
M
0
C
/
T
1
G
A
T
E
1
G
A
T
E
0
C
/
T
0
T
0
M
1
T
0
M
0
SYSCLK
12
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
GATE0
C8051F020/1/2/3
Rev. 1.4 229
22.1.3. Mode 2: 8-bit Counter/Timer with Auto-Reload
Mode 2 configures Timer 0 and Timer 1 to operate as 8-bit counter/timers with automatic reload of the start value.
The TL0 holds the count and TH0 holds the reload value. When the counter in TL0 overflows from all ones to 0x00,
the timer overflow flag TF0 (TCON.5) is set and the counter value in TL0 is reloaded from TH0. If enabled, an inter-
rupt will occur when the TF0 flag is set. The reload value in TH0 is not changed. TL0 must be initialized to the
desired value before enabling the timer for the first count to be correct. When in Mode 2, Timer 1 operates identically
to Timer 0. Both counter/timers are enabled and configured in Mode 2 in the same manner as Mode 0.
Figure 22.3. T0 Mode 2 (8-bit Auto-Reload) Block Diagram
TCLK
TMOD
T
1
M
1
T
1
M
0
C
/
T
1
G
A
T
E
1
G
A
T
E
0
C
/
T
0
T
0
M
1
T
0
M
0
T
C
O
N
TF0
TR0
TR1
TF1
IE1
IT1
IE0
IT0
Interrupt
TL0
(8 bits)
Reload
TH0
(8 bits)
/INT0 TR0
T0
Crossbar
0
1
0
1
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
SYSCLK
12
GATE0
C8051F020/1/2/3
230 Rev. 1.4
22.1.4. Mode 3: Two 8-bit Counter/Timers (Timer 0 Only)
Timer 0 and Timer 1 behave differently in Mode 3. Timer 0 is configured as two separate 8-bit counter/timers held in
TL0 and TH0. The counter/timer in TL0 is controlled using the Timer 0 control/status bits in TCON and TMOD:
TR0, C/T0, GATE0 and TF0. It can use either the system clock or an external input signal as its timebase. The timer
in the TH0 register is restricted to a timer function sourced by the system clock. TH0 is enabled using the Timer 1 run
control bit TR1. TH0 sets the Timer 1 overflow flag TF1 on overflow and thus controls the Timer 1 interrupt.
Timer 1 is inactive in Mode 3, so with Timer 0 in Mode 3, Timer 1 can be turned off and on by switching it into and
out of its Mode 3. When Timer 0 is in Mode 3, Timer 1 can be operated in Modes 0, 1 or 2, but cannot be clocked by
external signals nor set the TF1 flag and generate an interrupt. However, the Timer 1 overflow can be used to gener-
ate the baud clock for UART0 and/or UART1. Refer to Section 20. UART0 on page 205 and Section
21. UART1 on page 215 for information on configuring Timer 1 for baud rate generation.
Figure 22.4. T0 Mode 3 (Two 8-bit Timers) Block Diagram
TL0
(8 bits)
TMOD
/INT0
TR0
T0
Crossbar
0
1
T
C
O
N
TF0
TR0
TR1
TF1
IE1
IT1
IE0
IT0
Interrupt
Interrupt
TR1
TH0
(8 bits)
T
1
M
1
T
1
M
0
C
/
T
1
G
A
T
E
1
G
A
T
E
0
C
/
T
0
T
0
M
1
T
0
M
0
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
0
1
SYSCLK
12
GATE0
C8051F020/1/2/3
Rev. 1.4 231
Figure 22.5. TCON: Timer Control Register
Bit7: TF1: Timer 1 Overflow Flag.
Set by hardware when Timer 1 overflows. This flag can be cleared by software but is automatically
cleared when the CPU vectors to the Timer 1 interrupt service routine.
0: No Timer 1 overflow detected.
1: Timer 1 has overflowed.
Bit6: TR1: Timer 1 Run Control.
0: Timer 1 disabled.
1: Timer 1 enabled.
Bit5: TF0: Timer 0 Overflow Flag.
Set by hardware when Timer 0 overflows. This flag can be cleared by software but is automatically
cleared when the CPU vectors to the Timer 0 interrupt service routine.
0: No Timer 0 overflow detected.
1: Timer 0 has overflowed.
Bit4: TR0: Timer 0 Run Control.
0: Timer 0 disabled.
1: Timer 0 enabled.
Bit3: IE1: External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It can be cleared
by software but is automatically cleared when the CPU vectors to the External Interrupt 1 service rou-
tine if IT1 = 1. This flag is the inverse of the /INT1 input signal's logic level when IT1 = 0.
Bit2: IT1: Interrupt 1 Type Select.
This bit selects whether the configured /INT1 signal will detect falling edge or active-low level-sensi-
tive interrupts.
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
Bit1: IE0: External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT0 is detected. It can be cleared
by software but is automatically cleared when the CPU vectors to the External Interrupt 0 service rou-
tine if IT0 = 1. This flag is the inverse of the /INT0 input signal's logic level when IT0 = 0.
Bit0: IT0: Interrupt 0 Type Select.
This bit selects whether the configured /INT0 signal will detect falling edge or active-low level-sensi-
tive interrupts.
0: /INT0 is level triggered.
1: /INT0 is edge triggered.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0x88
C8051F020/1/2/3
232 Rev. 1.4
Figure 22.6. TMOD: Timer Mode Register
Bit7: GATE1: Timer 1 Gate Control.
0: Timer 1 enabled when TR1 = 1 irrespective of /INT1 logic level.
1: Timer 1 enabled only when TR1 = 1 AND /INT1 = logic 1.
Bit6: C/T1: Counter/Timer 1 Select.
0: Timer Function: Timer 1 incremented by clock defined by T1M bit (CKCON.4).
1: Counter Function: Timer 1 incremented by high-to-low transitions on external input pin (T1).
Bits5-4: T1M1-T1M0: Timer 1 Mode Select.
These bits select the Timer 1 operation mode.
Bit3: GATE0: Timer 0 Gate Control.
0: Timer 0 enabled when TR0 = 1 irrespective of /INT0 logic level.
1: Timer 0 enabled only when TR0 = 1 AND /INT0 = logic 1.
Bit2: C/T0: Counter/Timer Select.
0: Timer Function: Timer 0 incremented by clock defined by T0M bit (CKCON.3).
1: Counter Function: Timer 0 incremented by high-to-low transitions on external input pin (T0).
Bits1-0: T0M1-T0M0: Timer 0 Mode Select.
These bits select the Timer 0 operation mode.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
GATE1 C/T1 T1M1 T1M0 GATE0 C/T0 T0M1 T0M0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x89
T1M1 T1M0 Mode
0 0 Mode 0: 13-bit counter/timer
0 1 Mode 1: 16-bit counter/timer
1 0 Mode 2: 8-bit counter/timer with auto-reload
1 1 Mode 3: Timer 1 inactive
T0M1 T0M0 Mode
0 0 Mode 0: 13-bit counter/timer
0 1 Mode 1: 16-bit counter/timer
1 0 Mode 2: 8-bit counter/timer with auto-reload
1 1 Mode 3: Two 8-bit counter/timers
C8051F020/1/2/3
Rev. 1.4 233
Figure 22.7. TL0: Timer 0 Low Byte
Bits 7-0: TL0: Timer 0 Low Byte.
The TL0 register is the low byte of the 16-bit Timer 0.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8A
Figure 22.8. TL1: Timer 1 Low Byte
Bits 7-0: TH0: Timer 0 High Byte.
The TH0 register is the low byte of the 16-bit Timer 1.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8B
Bits 7-0: TH0: Timer 0 High Byte.
The TH0 register is the high byte of the 16-bit Timer 0.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8C
Figure 22.9. TH0 Timer 0 High Byte
Figure 22.10. TH1: Timer 1 High Byte
Bits 7-0: TH1: Timer 1 High Byte.
The TH1 register is the high byte of the 16-bit Timer 1.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x8D
C8051F020/1/2/3
234 Rev. 1.4
22.1. Timer 2
Timer 2 is a 16-bit counter/timer formed by the two 8-bit SFRs: TL2 (low byte) and TH2 (high byte). As with
Timers 0 and 1, Timer 2 can use either the system clock or transitions on an external input pin (T2) as its clock
source. The Counter/Timer Select bit C/T2 bit (T2CON.1) selects the clock source for Timer 2. Clearing C/T2 selects
the system clock as the input for the timer (divided by either one or twelve as specified by the Timer Clock Select bit
T2M in CKCON). When C/T2 is set to 1, high-to-low transitions at the T2 input pin increment the counter/timer reg-
ister. (Refer to Section 17.1. Ports 0 through 3 and the Priority Crossbar Decoder on page 163 for information on
selecting and configuring external I/O pins for digital peripherals.) Timer 2 can also be used to start an ADC Data
Conversion.
Timer 2 offers capabilities not found in Timer 0 and Timer 1. It operates in one of three modes: 16-bit Counter/Timer
with Capture, 16-bit Counter/Timer with Auto-Reload or Baud Rate Generator Mode. Timer 2's operating mode is
selected by setting configuration bits in the Timer 2 Control register (T2CON). Below is a summary of the Timer 2
operating modes and the T2CON bits used to configure the counter/timer. Detailed descriptions of each mode follow.
RCLK0 TCLK0 CP/RL2 TR2 Mode
0 0 1 1 16-bit Counter/Timer with Capture
0 0 0 1 16-bit Counter/Timer with Auto-Reload
0 1 X 1 Baud Rate Generator for UART0
1 0 X 1 Baud Rate Generator for UART0
1 1 X 1 Baud Rate Generator for UART0
X X X 0 Off
C8051F020/1/2/3
Rev. 1.4 235
22.1.1. Mode 0: 16-bit Counter/Timer with Capture
In this mode, Timer 2 operates as a 16-bit counter/timer with capture facility. A high-to-low transition on the T2EX
input pin causes the following to occur:
1. The 16-bit value in Timer 2 (TH2, TL2) is loaded into the capture registers (RCAP2H, RCAP2L).
2. The Timer 2 External Flag (EXF2) is set to 1.
3. A Timer 2 interrupt is generated if enabled.
Timer 2 can use either SYSCLK, SYSCLK divided by 12, or high-to-low transitions on the T2 input pin as its clock
source when operating in Capture mode. Clearing the C/T2 bit (T2CON.1) selects the system clock as the input for
the timer (divided by one or twelve as specified by the Timer Clock Select bit T2M in CKCON). When C/T2 is set to
logic 1, a high-to-low transition at the T2 input pin increments the counter/timer register. As the 16-bit counter/timer
register increments and overflows from 0xFFFF to 0x0000, the TF2 timer overflow flag (T2CON.7) is set and an
interrupt will occur if the interrupt is enabled.
Counter/Timer with Capture mode is selected by setting the Capture/Reload Select bit CP/RL2 (T2CON.0) and the
Timer 2 Run Control bit TR2 (T2CON.2) to logic 1. The Timer 2 External Enable EXEN2 (T2CON.3) must also be
set to logic 1 to enable a capture. If EXEN2 is cleared, transitions on T2EX will be ignored.
Figure 22.11. T2 Mode 0 Block Diagram
TL2 TH2
Interrupt
TCLK
RCAP2L RCAP2H
Capture
T
2
C
O
N
RCLK0
TCLK0
EXF2
EXEN2
TR2
C/T2
CP/RL2
TF2
EXEN2
Crossbar
T2EX
TR2
T2
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
0
1
SYSCLK
12
0
1
C8051F020/1/2/3
236 Rev. 1.4
22.1.2. Mode 1: 16-bit Counter/Timer with Auto-Reload
The Counter/Timer with Auto-Reload mode sets the TF2 timer overflow flag when the counter/timer register over-
flows from 0xFFFF to 0x0000. An interrupt is generated if enabled. On overflow, the 16-bit value held in the two
capture registers (RCAP2H, RCAP2L) is automatically loaded into the counter/timer register and the timer is
restarted.
Counter/Timer with Auto-Reload mode is selected by clearing the CP/RL2 bit. Setting TR2 to logic 1 enables and
starts the timer. Timer 2 can use either the system clock or transitions on an external input pin (T2) as its clock source,
as specified by the C/T2 bit. If EXEN2 is set to logic 1, a high-to-low transition on T2EX will also cause a Timer 2
reload, and a Timer 2 interrupt if enabled. If EXEN2 is logic 0, transitions on T2EX will be ignored.
Figure 22.12. T2 Mode 1 Block Diagram
TL2 TH2
TR2
T2 TCLK
RCAP2L RCAP2H
Reload
Interrupt
T
2
C
O
N
RCLK0
TCLK0
EXF2
EXEN2
TR2
C/T2
CP/RL2
TF2
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
0
1
SYSCLK
12
0
1
EXEN2
Crossbar
T2EX
C8051F020/1/2/3
Rev. 1.4 237
22.1.3. Mode 2: Baud Rate Generator
Timer 2 can be used as a baud rate generator for UART0 when UART0 is operated in modes 1 or 3 (refer to Section
20.1. UART0 Operational Modes on page 206 for more information on the UART0 operational modes). In Baud
Rate Generator mode, Timer 2 works similarly to the auto-reload mode. On overflow, the 16-bit value held in the two
capture registers (RCAP2H, RCAP2L) is automatically loaded into the counter/timer register. However, the TF2
overflow flag is not set and no interrupt is generated. Instead, the overflow event is used as the input to the UART's
shift clock. Timer 2 overflows can be selected to generate baud rates for transmit and/or receive independently.
The Baud Rate Generator mode is selected by setting RCLK0 (T2CON.5) and/or TCLK0 (T2CON.2) to 1. When
RCLK0 or TCLK0 is set to logic 1, Timer 2 operates in the auto-reload mode regardless of the state of the CP/RL2
bit. Note that in Baud Rate Generator mode, the Timer 2 timebase is the system clock divided by two. When selected
as the UART0 baud clock source, Timer 2 defines the UART0 baud rate as follows:
Baud Rate = SYSCLK / ((65536 - [RCAP2H, RCAP2L] ) * 32)
If a different time base is required, setting the C/T2 bit to logic 1 will allow the timebase to be derived from the exter-
nal input pin T2. In this case, the baud rate for the UART is calculated as:
Baud Rate = F
CLK
/ ( (65536 - [RCAP2H, RCAP2L] ) * 16)
Where F
CLK
is the frequency of the signal (TCLK) supplied to Timer 2 and [RCAP2H, RCAP2L] is the 16-bit value
held in the capture registers.
As explained above, in Baud Rate Generator mode, Timer 2 does not set the TF2 overflow flag and therefore cannot
generate an interrupt. However, if EXEN2 is set to logic 1, a high-to-low transition on the T2EX input pin will set the
EXF2 flag and a Timer 2 interrupt will occur if enabled. Therefore, the T2EX input may be used as an additional
external interrupt source.
Figure 22.13. T2 Mode 2 Block Diagram
TL2 TH2
TR2
T2
SYSCLK
C/T2
2
TCLK
RCAP2L RCAP2H
Reload
Crossbar
Timer 2
Overflow
PCON
0
1
EXEN2
T2EX
Interrupt
Timer 1
Overflow
T
2
C
O
N
RCLK0
TCLK0
EXF2
EXEN2
TR2
C/T2
CP/RL2
TF2
Crossbar
0
1
2
S
M
O
D
0
S
M
O
D
1
S
S
T
A
T
0
S
S
T
A
T
1
S
T
O
P
I
D
L
E
RCLK0
0
1
16
RX0 Clock
TCLK0
0
1
16
TX0 Clock
C8051F020/1/2/3
238 Rev. 1.4
Bit7: TF2: Timer 2 Overflow Flag.
Set by hardware when Timer 2 overflows. When the Timer 2 interrupt is enabled, setting this bit
causes the CPU to vector to the Timer 2 interrupt service routine. This bit is not automatically cleared
by hardware and must be cleared by software. TF2 will not be set when RCLK0 and/or TCLK0 are
logic 1.
Bit6: EXF2: Timer 2 External Flag.
Set by hardware when either a capture or reload is caused by a high-to-low transition on the T2EX
input pin and EXEN2 is logic 1. When the Timer 2 interrupt is enabled, setting this bit causes the
CPU to vector to the Timer 2 Interrupt service routine. This bit is not automatically cleared by hard-
ware and must be cleared by software.
Bit5: RCLK0: Receive Clock Flag for UART0.
Selects which timer is used for the UART0 receive clock in modes 1 or 3.
0: Timer 1 overflows used for receive clock.
1: Timer 2 overflows used for receive clock.
Bit4: TCLK0: Transmit Clock Flag for UART0.
Selects which timer is used for the UART0 transmit clock in modes 1 or 3.
0: Timer 1 overflows used for transmit clock.
1: Timer 2 overflows used for transmit clock.
Bit3: EXEN2: Timer 2 External Enable.
Enables high-to-low transitions on T2EX to trigger captures or reloads when Timer 2 is not operating
in Baud Rate Generator mode.
0: High-to-low transitions on T2EX ignored.
1: High-to-low transitions on T2EX cause a capture or reload.
Bit2: TR2: Timer 2 Run Control.
This bit enables/disables Timer 2.
0: Timer 2 disabled.
1: Timer 2 enabled.
Bit1: C/T2: Counter/Timer Select.
0: Timer Function: Timer 2 incremented by clock defined by T2M (CKCON.5).
1: Counter Function: Timer 2 incremented by high-to-low transitions on external input pin (T2).
Bit0: CP/RL2: Capture/Reload Select.
This bit selects whether Timer 2 functions in capture or auto-reload mode. EXEN2 must be logic 1 for
high-to-low transitions on T2EX to be recognized and used to trigger captures or reloads. If RCLK0
or TCLK0 is set, this bit is ignored and Timer 2 will function in auto-reload mode.
0: Auto-reload on Timer 2 overflow or high-to-low transition at T2EX (EXEN2 = 1).
1: Capture on high-to-low transition at T2EX (EXEN2 = 1).
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
TF2 EXF2 RCLK0 TCLK0 EXEN2 TR2 C/T2 CP/RL2 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xC8
Figure 22.14. T2CON: Timer 2 Control Register
C8051F020/1/2/3
Rev. 1.4 239
Bits 7-0: RCAP2L: Timer 2 Capture Register Low Byte.
The RCAP2L register captures the low byte of Timer 2 when Timer 2 is configured in capture mode.
When Timer 2 is configured in auto-reload mode, it holds the low byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xCA
Figure 22.15. RCAP2L: Timer 2 Capture Register Low Byte
Figure 22.16. RCAP2H: Timer 2 Capture Register High Byte
Bits 7-0: RCAP2H: Timer 2 Capture Register High Byte.
The RCAP2H register captures the high byte of Timer 2 when Timer 2 is configured in capture mode.
When Timer 2 is configured in auto-reload mode, it holds the high byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xCB
Figure 22.17. TL2: Timer 2 Low Byte
Bits 7-0: TL2: Timer 2 Low Byte.
The TL2 register contains the low byte of the 16-bit Timer 2.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xCC
Figure 22.18. TH2 Timer 2 High Byte
Bits 7-0: TH2: Timer 2 High Byte.
The TH2 register contains the high byte of the 16-bit Timer 2.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xCD
C8051F020/1/2/3
240 Rev. 1.4
22.2. Timer 3
Timer 3 is a 16-bit timer formed by the two 8-bit SFRs, TMR3L (low byte) and TMR3H (high byte). Timer 3 may be
clocked by the external oscillator source (divided by eight) or the system clock (divided by either one or twelve as
specified by the Timer 3 Clock Select bit T3M in the Timer 3 Control Register TMR3CN). Timer 3 is always config-
ured as an auto-reload timer, with the reload value held in the TMR3RLL (low byte) and TMR3RLH (high byte) reg-
isters.
The Timer 3 external clock source feature offers a real-time clock (RTC) mode. When bit T3XCLK (TMR3CN.0) is
set to logic 1, Timer 3 is clocked by the external oscillator input (divided by 8) regardless of the system clock selec-
tion. This split clock domain allows Timer 3 to be clocked by a precision external source while the system clock is
derived from the high-speed internal oscillator. When T3XCLK is logic 0, the Timer 3 clock source is specified by bit
T3M (TMR3CN.1).
Timer 3 can also be used to start an ADC Data Conversion, for SMBus timing (see Section 18. SYSTEM MAN-
AGEMENT BUS / I2C BUS (SMBUS0) on page 183), or as a general-purpose timer. Timer 3 does not have a coun-
ter mode.
Figure 22.19. Timer 3 Block Diagram
TMR3L TMR3H
TR3
TCLK
TMR3RLL TMR3RLH
Reload
Interrupt
TOE
SCL
(from SMBus)
(to ADC)
Crossbar
T
M
R
3
C
N
TR3
T3M
TF3
T3XCLK
1
0
T3XCLK
SYSCLK
12
T3M
8
External
Oscillator Source
1
0
C8051F020/1/2/3
Rev. 1.4 241
Figure 22.20. TMR3CN: Timer 3 Control Register
Bit7: TF3: Timer3 Overflow Flag.
Set by hardware when Timer 3 overflows from 0xFFFF to 0x0000. When the Timer 3 interrupt is
enabled, setting this bit causes the CPU to vector to the Timer 3 Interrupt service routine. This bit is
not automatically cleared by hardware and must be cleared by software.
Bits6-3: UNUSED. Read = 0000b, Write = don't care.
Bit2: TR3: Timer 3 Run Control.
This bit enables/disables Timer 3.
0: Timer 3 disabled.
1: Timer 3 enabled.
Bit1: T3M: Timer 3 Clock Select.
This bit controls the division of the system clock supplied to Counter/Timer 3.
0: Counter/Timer 3 uses the system clock divided by 12.
1: Counter/Timer 3 uses the system clock.
Bit0: T3XCLK: Timer 3 External Clock Select
This bit selects the external oscillator input divided by 8 as the Timer 3 clock source. When T3XCLK
is logic 1, bit T3M (TMR3CN.1) is ignored.
0: Timer 3 clock source defined by bit T3M (TMR3CN.1).
1: Timer 3 clock source is the external oscillator input divided by 8.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
TF3 - - - - TR3 T3M T3XCLK 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x91
Figure 22.21. TMR3RLL: Timer 3 Reload Register Low Byte
Bits 7-0: TMR3RLL: Timer 3 Reload Register Low Byte.
Timer 3 is configured as an auto-reload timer. This register holds the low byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x92
C8051F020/1/2/3
242 Rev. 1.4
Figure 22.22. TMR3RLH: Timer 3 Reload Register High Byte
Bits 7-0: TMR3RLH: Timer 3 Reload Register High Byte.
Timer 3 is configured as an auto-reload timer. This register holds the high byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x93
Figure 22.23. TMR3L: Timer 3 Low Byte
Bits 7-0: TMR3L: Timer 3 Low Byte.
The TMR3L register is the low byte of Timer 3.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x94
Figure 22.24. TMR3H: Timer 3 High Byte
Bits 7-0: TMR3H: Timer 3 High Byte.
The TMR3H register is the high byte of Timer 3.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0x95
C8051F020/1/2/3
Rev. 1.4 243
22.3. Timer 4
Timer 4 is a 16-bit counter/timer formed by the two 8-bit SFRs: TL4 (low byte) and TH4 (high byte). As with
Timers 0 and 1, Timer 4 can use either the system clock or transitions on an external input pin (T4) as its clock
source. The Counter/Timer Select bit C/T4 bit (T4CON.1) selects the clock source for Timer 4. Clearing C/T4 selects
the system clock as the input for the timer (divided by either one or twelve as specified by the Timer Clock Select bit
T4M in CKCON). When C/T4 is set to 1, high-to-low transitions at the T4 input pin increment the counter/timer reg-
ister. Refer to Section 17.1. Ports 0 through 3 and the Priority Crossbar Decoder on page 163 for information on
selecting and configuring external I/O pins for digital peripherals.
Timer 4 offers capabilities not found in Timer 0 and Timer 1. It operates in one of three modes: 16-bit Counter/Timer
with Capture, 16-bit Counter/Timer with Auto-Reload or Baud Rate Generator Mode. Timer 4's operating mode is
selected by setting configuration bits in the Timer 4 Control register (T4CON). Below is a summary of the Timer 4
operating modes and the T4CON bits used to configure the counter/timer. Detailed descriptions of each mode follow.
RCLK1 TCLK1 CP/RL4 TR4 Mode
0 0 1 1 16-bit Counter/Timer with Capture
0 0 0 1 16-bit Counter/Timer with Auto-Reload
0 1 X 1 Baud Rate Generator for UART1
1 0 X 1 Baud Rate Generator for UART1
1 1 X 1 Baud Rate Generator for UART1
X X X 0 Off
C8051F020/1/2/3
244 Rev. 1.4
22.3.1. Mode 0: 16-bit Counter/Timer with Capture
In this mode, Timer 4 operates as a 16-bit counter/timer with capture facility. A high-to-low transition on the T4EX
input pin causes the following to occur:
1. The 16-bit value in Timer 4 (TH4, TL4) is loaded into the capture registers (RCAP4H, RCAP4L).
2. The Timer 4 External Flag (EXF2) is set to 1.
3. A Timer 4 interrupt is generated if enabled.
Timer 4 can use either SYSCLK, SYSCLK divided by 12, or high-to-low transitions on the T4 input pin as its clock
source when operating in Capture mode. Clearing the C/T4 bit (T4CON.1) selects the system clock as the input for
the timer (divided by one or twelve as specified by the Timer Clock Select bit T4M in CKCON). When C/T4 is set to
logic 1, a high-to-low transition at the T4 input pin increments the counter/timer register. As the 16-bit counter/timer
register increments and overflows from 0xFFFF to 0x0000, the TF4 timer overflow flag (T4CON.7) is set and an
interrupt will occur if the interrupt is enabled.
Counter/Timer with Capture mode is selected by setting the Capture/Reload Select bit CP/RL4 (T4CON.0) and the
Timer 4 Run Control bit TR4 (T4CON.2) to logic 1. The Timer 4 External Enable EXEN4 (T4CON.3) must also be
set to logic 1 to enable a capture. If EXEN4 is cleared, transitions on T4EX will be ignored.
Figure 22.25. T4 Mode 0 Block Diagram
TL4 TH4
Interrupt
TCLK
RCAP4L RCAP4H
Capture
T
4
C
O
N
RCLK0
TCLK0
EXF4
EXEN4
TR4
C/T4
CP/RL4
TF4
EXEN4
Crossbar
T4EX
TR4
T4
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
0
1
SYSCLK
12
0
1
C8051F020/1/2/3
Rev. 1.4 245
22.3.2. Mode 1: 16-bit Counter/Timer with Auto-Reload
The Counter/Timer with Auto-Reload mode sets the TF4 timer overflow flag when the counter/timer register over-
flows from 0xFFFF to 0x0000. An interrupt is generated if enabled. On overflow, the 16-bit value held in the two
capture registers (RCAP4H, RCAP4L) is automatically loaded into the counter/timer register and the timer is
restarted.
Counter/Timer with Auto-Reload mode is selected by clearing the CP/RL4 bit. Setting TR4 to logic 1 enables and
starts the timer. Timer 4 can use either the system clock or transitions on an external input pin (T2) as its clock source,
as specified by the C/T4 bit. If EXEN4 is set to logic 1, a high-to-low transition on T4EX will also cause a Timer 4
reload, and a Timer 4 interrupt if enabled. If EXEN4 is logic 0, transitions on T4EX will be ignored.
Figure 22.26. T4 Mode 1 Block Diagram
TL4 TH4
TR4
T4 TCLK
RCAP4L RCAP4H
Reload
Interrupt
T
4
C
O
N
RCLK0
TCLK0
EXF4
EXEN4
TR4
C/T4
CP/RL4
TF4
CKCON
T
4
M
T
2
M
T
1
M
T
0
M
0
1
SYSCLK
12
0
1
EXEN4
Crossbar
T4EX
C8051F020/1/2/3
246 Rev. 1.4
22.3.3. Mode 2: Baud Rate Generator
Timer 4 can be used as a baud rate generator for UART1 when UART1 is operated in modes 1 or 3 (refer to Section
21.1. UART1 Operational Modes on page 216 for more information on the UART1 operational modes). In Baud
Rate Generator mode, Timer 4 works similarly to the auto-reload mode. On overflow, the 16-bit value held in the two
capture registers (RCAP4H, RCAP4L) is automatically loaded into the counter/timer register. However, the TF4
overflow flag is not set and no interrupt is generated. Instead, the overflow event is used as the input to the UART's
shift clock. Timer 4 overflows can be selected to generate baud rates for transmit and/or receive independently.
The Baud Rate Generator mode is selected by setting RCLK1 (T4CON.5) and/or TCLK1 (T4CON.4) to 1. When
RCLK1 or TCLK1 is set to logic 1, Timer 4 operates in the auto-reload mode regardless of the state of the CP/RL4
bit. Note that in Baud Rate Generator mode, the Timer 4 timebase is the system clock divided by two. When selected
as the UART1 baud clock source, Timer 4 defines the UART1 baud rate as follows:
Baud Rate = SYSCLK / ((65536 - [RCAP4H, RCAP4L] ) * 32)
If a different time base is required, setting the C/T4 bit to logic 1 will allow the timebase to be derived from the exter-
nal input pin T4. In this case, the baud rate for the UART is calculated as:
Baud Rate = F
CLK
/ ( (65536 - [RCAP4H, RCAP4L] ) * 16)
Where F
CLK
is the frequency of the signal (TCLK) supplied to Timer 4 and [RCAP4H, RCAP4L] is the 16-bit value
held in the capture registers.
As explained above, in Baud Rate Generator mode, Timer 4 does not set the TF4 overflow flag and therefore cannot
generate an interrupt. However, if EXEN4 is set to logic 1, a high-to-low transition on the T4EX input pin will set the
EXF4 flag and a Timer 4 interrupt will occur if enabled. Therefore, the T4EX input may be used as an additional
external interrupt source.
Figure 22.27. T4 Mode 2 Block Diagram
TL2 TH2
TR2
T2
SYSCLK
C/T2
2
TCLK
RCAP2L RCAP2H
Reload
RCLK0
Crossbar
Timer 2
Overflow
PCON
S
M
O
D
0
S
T
O
P
I
D
L
E
0
1 0
1
16
RX0 Clock
EXEN2
T2EX
Interrupt
Timer 1
Overflow
T
2
C
O
N
RCLK0
TCLK0
EXF2
EXEN2
TR2
C/T2
CP/RL2
TF2
Crossbar
0
1
2
TCLK0
0
1
16
TX0 Clock
C8051F020/1/2/3
Rev. 1.4 247
Bit7: TF4: Timer 4 Overflow Flag.
Set by hardware when Timer 4 overflows. When the Timer 4 interrupt is enabled, setting this bit
causes the CPU to vector to the Timer 4 interrupt service routine. This bit is not automatically cleared
by hardware and must be cleared by software. TF4 will not be set when RCLK1 and/or TCLK1 are
logic 1.
Bit6: EXF4: Timer 4 External Flag.
Set by hardware when either a capture or reload is caused by a high-to-low transition on the T4EX
input pin and EXEN4 is logic 1. When the Timer 4 interrupt is enabled, setting this bit causes the
CPU to vector to the Timer 4 Interrupt service routine. This bit is not automatically cleared by hard-
ware and must be cleared by software.
Bit5: RCLK1: Receive Clock Flag for UART1.
Selects which timer is used for the UART1 receive clock in modes 1 or 3.
0: Timer 1 overflows used for receive clock.
1: Timer 4 overflows used for receive clock.
Bit4: TCLK1: Transmit Clock Flag for UART1.
Selects which timer is used for the UART1 transmit clock in modes 1 or 3.
0: Timer 1 overflows used for transmit clock.
1: Timer 4 overflows used for transmit clock.
Bit3: EXEN4: Timer 4 External Enable.
Enables high-to-low transitions on T4EX to trigger captures or reloads when Timer 4 is not operating
in Baud Rate Generator mode.
0: High-to-low transitions on T4EX ignored.
1: High-to-low transitions on T4EX cause a capture or reload.
Bit2: TR4: Timer 4 Run Control.
This bit enables/disables Timer 4.
0: Timer 4 disabled.
1: Timer 4 enabled.
Bit1: C/T4: Counter/Timer Select.
0: Timer Function: Timer 4 incremented by clock defined by T4M (CKCON.6).
1: Counter Function: Timer 4 incremented by high-to-low transitions on external input pin (T2).
Bit0: CP/RL4: Capture/Reload Select.
This bit selects whether Timer 4 functions in capture or auto-reload mode. EXEN4 must be logic 1 for
high-to-low transitions on T4EX to be recognized and used to trigger captures or reloads. If RCLK1
or TCLK1 is set, this bit is ignored and Timer 4 will function in auto-reload mode.
0: Auto-reload on Timer 4 overflow or high-to-low transition at T4EX (EXEN4 = 1).
1: Capture on high-to-low transition at T4EX (EXEN4 = 1).
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
TF4 EXF4 RCLK1 TCLK1 EXEN4 TR4 C/T4 CP/RL4 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xC9
Figure 22.28. T4CON: Timer 4 Control Register
C8051F020/1/2/3
248 Rev. 1.4
Bits 7-0: RCAP4L: Timer 4 Capture Register Low Byte.
The RCAP4L register captures the low byte of Timer 4 when Timer 4 is configured in capture mode.
When Timer 4 is configured in auto-reload mode, it holds the low byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE4
Figure 22.29. RCAP4L: Timer 4 Capture Register Low Byte
Figure 22.30. RCAP4H: Timer 4 Capture Register High Byte
Bits 7-0: RCAP4H: Timer 4 Capture Register High Byte.
The RCAP4H register captures the high byte of Timer 4 when Timer 4 is configured in capture mode.
When Timer 4 is configured in auto-reload mode, it holds the high byte of the reload value.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE5
Figure 22.31. TL4: Timer 4 Low Byte
Bits 7-0: TL4: Timer 4 Low Byte.
The TL4 register contains the low byte of the 16-bit Timer 4.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF4
Figure 22.32. TH4 Timer 4 High Byte
Bits 7-0: TH4: Timer 4 High Byte.
The TH4 register contains the high byte of the 16-bit Timer 4.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF5
C8051F020/1/2/3
Rev. 1.4 249
23. PROGRAMMABLE COUNTER ARRAY
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU interven-
tion than the standard 8051 counter/timers. PCA0 consists of a dedicated 16-bit counter/timer and five 16-bit capture/
compare modules. Each capture/compare module has its own associated I/O line (CEXn) which is routed through the
Crossbar to Port I/O when enabled (See Section 17.1. Ports 0 through 3 and the Priority Crossbar Decoder on
page 163). The counter/timer is driven by a programmable timebase that can select between six inputs as its source:
system clock, system clock divided by four, system clock divided by twelve, the external oscillator clock source
divided by 8, Timer 0 overflow, or an external clock signal on the ECI line. Each capture/compare module may be
configured to operate independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Out-
put, Frequency Output, 8-Bit PWM, or 16-Bit PWM (each is described in Section 23.2). The PCA is configured and
controlled through the system controller's Special Function Registers. The basic PCA block diagram is shown in
Figure 23.1.
Figure 23.1. PCA Block Diagram
Capture/Compare
Module 1
Capture/Compare
Module 0
Capture/Compare
Module 2
Capture/Compare
Module 3
Capture/Compare
Module 4
C
E
X
1
E
C
I
Crossbar
C
E
X
2
C
E
X
3
C
E
X
4
C
E
X
0
Port I/O
16-Bit Counter/Timer
PCA
CLOCK
MUX
SYSCLK/12
SYSCLK/4
Timer 0 Overflow
ECI
SYSCLK
External Clock/8
C8051F020/1/2/3
250 Rev. 1.4
23.1. PCA Counter/Timer
The 16-bit PCA counter/timer consists of two 8-bit SFRs: PCA0L and PCA0H. PCA0H is the high byte (MSB) of the
16-bit counter/timer and PCA0L is the low byte (LSB). Reading PCA0L automatically latches the value of PCA0H
into a snapshot register; the following PCA0H read accesses this snapshot register. Reading the PCA0L Register
first guarantees an accurate reading of the entire 16-bit PCA0 counter. Reading PCA0H or PCA0L does not disturb
the counter operation. The CPS2-CPS0 bits in the PCA0MD register select the timebase for the counter/timer as
shown in Table 23.1. Note that in External oscillator source divided by 8 mode, the external oscillator source
is synchronized with the system clock, and must have a frequency less than or equal to the system clock.
When the counter/timer overflows from 0xFFFF to 0x0000, the Counter Overflow Flag (CF) in PCA0MD is set to
logic 1 and an interrupt request is generated if CF interrupts are enabled. Setting the ECF bit in PCA0MD to logic 1
enables the CF flag to generate an interrupt request. The CF bit is not automatically cleared by hardware when the
CPU vectors to the interrupt service routine, and must be cleared by software (Note: PCA0 interrupts must be glob-
ally enabled before CF interrupts are recognized. PCA0 interrupts are globally enabled by setting the EA bit (IE.7)
and the EPCA0 bit in EIE1 to logic 1). Clearing the CIDL bit in the PCA0MD register allows the PCA to continue
normal operation while the CPU is in Idle mode.
Table 23.1. PCA Timebase Input Options
CPS2 CPS1 CPS0 Timebase
0 0 0 System clock divided by 12
0 0 1 System clock divided by 4
0 1 0 Timer 0 overflow
0 1 1
High-to-low transitions on ECI
The minimum high or low time for the ECI input signal is at least 2 system clock cycles.
Figure 23.2. PCA Counter/Timer Block Diagram
PCA0MD
C
I
D
L
W
D
T
E
E
C
F
C
P
S
1
C
P
S
0
W
D
L
C
K
C
P
S
2
IDLE
0
1
PCA0H PCA0L
Snapshot
Register
To SFR Bus
Overflow
To PCA Interrupt System
CF
PCA0L
read
To PCA Modules
SYSCLK/12
SYSCLK/4
Timer 0 Overflow
ECI
000
001
010
011
100
101
SYSCLK
External Clock/8
PCA0CN
C
F
C
R
C
C
F
0
C
C
F
2
C
C
F
1
C
C
F
4
C
C
F
3
C8051F020/1/2/3
Rev. 1.4 251
Important Note About the PCA0CN Register: If the main PCA counter (PCA0H : PCA0L) overflows during the
execution phase of a read-modify-write instruction (bit-wise SETB or CLR, ANL, ORL, XRL) that targets the
PCA0CN register, the CF (Counter Overflow) bit will not be set. The following steps should be taken when perform-
ing a bit-wise operation on the PCA0CN register:
Step 1. Disable global interrupts (EA = 0).
Step 2. Read PCA0L. This will latch the value of PCA0H.
Step 3. Read PCA0H, saving the value.
Step 4. Execute the bit-wise operation on CCFn (for example, CLR CCF0, or CCF0 = 0;).
Step 5. Read PCA0L.
Step 6. Read PCA0H, saving the value.
Step 7. If the value of PCA0H read in Step 3 is 0xFF and the value for PCA0H read in Step 6 is 0x00, then
manually set the CF bit in software (for example, SETB CF, or CF = 1;).
Step 8. Re-enable interrupts (EA = 1).
C8051F020/1/2/3
252 Rev. 1.4
23.2. Capture/Compare Modules
Each module can be configured to operate independently in one of six operation modes: Edge-triggered Capture,
Software Timer, High Speed Output, Frequency Output, 8-Bit Pulse Width Modulator, or 16-Bit Pulse Width Modu-
lator. Each module has Special Function Registers (SFRs) associated with it in the CIP-51 system controller. These
registers are used to exchange data with a module and configure the module's mode of operation.
Table 23.2 summarizes the bit settings in the PCA0CPMn registers used to select the PCA0 capture/compare mod-
ules operating modes. Setting the ECCFn bit in a PCA0CPMn register enables the module's CCFn interrupt. Note:
PCA0 interrupts must be globally enabled before individual CCFn interrupts are recognized. PCA0 interrupts are
globally enabled by setting the EA bit (IE.7) and the EPCA0 bit (EIE1.3) to logic 1. See Figure 23.3 for details on the
PCA interrupt configuration.
Table 23.2. PCA0CPM Register Settings for PCA Capture/Compare Modules
PWM16 ECOM CAPP CAPN MAT TOG PWM ECCF Operation Mode
X X 1 0 0 0 0 X
Capture triggered by positive edge on
CEXn
X X 0 1 0 0 0 X
Capture triggered by negative edge on
CEXn
X X 1 1 0 0 0 X
Capture triggered by transition on
CEXn
X 1 0 0 1 0 0 X Software Timer
X 1 0 0 1 1 0 X High Speed Output
X 1 0 0 X 1 1 X Frequency Output
0 1 0 0 X 0 1 X 8-Bit Pulse Width Modulator
1 1 0 0 X 0 1 X 16-Bit Pulse Width Modulator
X = Dont Care
Figure 23.3. PCA Interrupt Block Diagram
PCA0CN
C
F
C
R
C
C
F
0
C
C
F
2
C
C
F
1
C
C
F
4
C
C
F
3
PCA0MD
C
I
D
L
E
C
F
C
P
S
1
C
P
S
0
C
P
S
2
0
1
PCA Module 0
(CCF0)
PCA Module 1
(CCF1)
ECCF1
0
1
ECCF0
0
1
PCA Module 2
(CCF2)
ECCF2
0
1
PCA Module 3
(CCF3)
ECCF3
0
1
PCA Module 4
(CCF4)
ECCF4
PCA Counter/
Timer Overflow
0
1
Interrupt
Priority
Decoder
EPCA0
(EIE1.3)
0
1
EA
(IE.7)
0
1
PCA0CPMn
(for n = 0 to 4)
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
C8051F020/1/2/3
Rev. 1.4 253
23.2.1. Edge-triggered Capture Mode
In this mode, a valid transition on the CEXn pin causes PCA0 to capture the value of the PCA0 counter/timer and
load it into the corresponding module's 16-bit capture/compare register (PCA0CPLn and PCA0CPHn). The CAPPn
and CAPNn bits in the PCA0CPMn register are used to select the type of transition that triggers the capture: low-to-
high transition (positive edge), high-to-low transition (negative edge), or either transition (positive or negative edge).
When a capture occurs, the Capture/Compare Flag (CCFn) in PCA0CN is set to logic 1 and an interrupt request is
generated if CCF interrupts are enabled. The CCFn bit is not automatically cleared by hardware when the CPU vec-
tors to the interrupt service routine, and must be cleared by software.
Note: The CEXn input signal must remain high or low for at least 2 system clock cycles in order to be valid.
Figure 23.4. PCA Capture Mode Diagram
PCA0L
PCA0CPLn
PCA
Timebase
CEXn
Crossbar Port I/O
PCA0H
Capture
PCA0CPHn
0
1
0
1
(
t
o
C
C
F
n
)
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
PCA0CN
C
F
C
R
C
C
F
0
C
C
F
2
C
C
F
1
C
C
F
4
C
C
F
3
PCA Interrupt
C8051F020/1/2/3
254 Rev. 1.4
23.2.2. Software Timer (Compare) Mode
In Software Timer mode, the PCA0 counter/timer is compared to the module's 16-bit capture/compare register
(PCA0CPHn and PCA0CPLn). When a match occurs, the Capture/Compare Flag (CCFn) in PCA0CN is set to logic
1 and an interrupt request is generated if CCF interrupts are enabled. The CCFn bit is not automatically cleared by
hardware when the CPU vectors to the interrupt service routine, and must be cleared by software. Setting the ECOMn
and MATn bits in the PCA0CPMn register enables Software Timer mode.
Important Note About Capture/Compare Registers: When writing a 16-bit value to the PCA0 Capture/Compare
registers, the low byte should always be written first. Writing to PCA0CPLn clears the ECOMn bit to 0; writing to
PCA0CPHn sets ECOMn to 1.
Figure 23.5. PCA Software Timer Mode Diagram
Match
16-bit Comparator
PCA0H
PCA0CPHn
Enable
PCA0L
PCA
Timebase
PCA0CPLn
0 0 0 0
0
1
x
ENB
ENB
0
1
Write to
PCA0CPLn
Write to
PCA0CPHn
Reset
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
x
PCA0CN
C
F
C
R
C
C
F
0
C
C
F
2
C
C
F
1
C
C
F
4
C
C
F
3
PCA Interrupt
C8051F020/1/2/3
Rev. 1.4 255
23.2.3. High Speed Output Mode
In High Speed Output mode, a modules associated CEXn pin is toggled each time a match occurs between the PCA
Counter and the module's 16-bit capture/compare register (PCA0CPHn and PCA0CPLn) Setting the TOGn, MATn,
and ECOMn bits in the PCA0CPMn register enables the High-Speed Output mode.
Important Note About Capture/Compare Registers: When writing a 16-bit value to the PCA0 Capture/Compare
registers, the low byte should always be written first. Writing to PCA0CPLn clears the ECOMn bit to 0; writing to
PCA0CPHn sets ECOMn to 1.
Figure 23.6. PCA High Speed Output Mode Diagram
Match
16-bit Comparator
PCA0H
PCA0CPHn
Enable
PCA0L
PCA
Timebase
PCA0CPLn
0
1
0 0 0 x
ENB
ENB
0
1
Write to
PCA0CPLn
Write to
PCA0CPHn
Reset
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
x
CEXn
Crossbar Port I/O
Toggle
0
1
TOGn
PCA0CN
C
F
C
R
C
C
F
0
C
C
F
2
C
C
F
1
C
C
F
4
C
C
F
3
PCA Interrupt
C8051F020/1/2/3
256 Rev. 1.4
23.2.4. Frequency Output Mode
Frequency Output Mode produces a programmable-frequency square wave on the modules associated CEXn pin.
The capture/compare module high byte holds the number of PCA clocks to count before the output is toggled. The
frequency of the square wave is then defined by Equation 23.1.
Note: A value of 0x00 in the PCA0CPHn register is equal to 256 for this equation.
Where F
PCA
is the frequency of the clock selected by the CPS2-0 bits in the PCA mode register, PCA0MD. The
lower byte of the capture/compare module is compared to the PCA0 counter low byte; on a match, CEXn is toggled
and the offset held in the high byte is added to the matched value in PCA0CPLn. Frequency Output Mode is enabled
by setting the ECOMn, TOGn, and PWMn bits in the PCA0CPMn register.
Equation 23.1. Square Wave Frequency Output
F
CEXn
F
PCA
2 PCA0CPHn
----------------------------------------- =
8-bit
Comparator
PCA0L
Enable
PCA Timebase
match
PCA0CPHn 8-bit Adder PCA0CPLn
Adder
Enable
CEXn
Crossbar Port I/O
Toggle
0
1
TOGn
0 0 0 x
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
x
ENB
ENB
0
1
Write to
PCA0CPLn
Write to
PCA0CPHn
Reset
Figure 23.7. PCA Frequency Output Mode
C8051F020/1/2/3
Rev. 1.4 257
23.2.5. 8-Bit Pulse Width Modulator Mode
Each module can be used independently to generate pulse width modulated (PWM) outputs on its associated CEXn
pin. The frequency of the output is dependent on the timebase for the PCA0 counter/timer. The duty cycle of the
PWM output signal is varied using the module's PCA0CPLn capture/compare register. When the value in the low
byte of the PCA0 counter/timer (PCA0L) is equal to the value in PCA0CPLn, the output on the CEXn pin will be
asserted high. When the count value in PCA0L overflows, the CEXn output will be asserted low (see Figure 23.8).
Also, when the counter/timer low byte (PCA0L) overflows from 0xFF to 0x00, PCA0CPLn is reloaded automatically
with the value stored in the counter/timer's high byte (PCA0H) without software intervention. Setting the ECOMn
and PWMn bits in the PCA0CPMn register enables 8-Bit Pulse Width Modulator mode. The duty cycle for 8-Bit
PWM Mode is given by Equation 23.2.
Important Note About Capture/Compare Registers: When writing a 16-bit value to the PCA0 Capture/Compare
registers, the low byte should always be written first. Writing to PCA0CPLn clears the ECOMn bit to 0; writing to
PCA0CPHn sets ECOMn to 1.
Using Equation 23.2, the largest duty cycle is 100% (PCA0CPHn = 0), and the smallest duty cycle is 0.39%
(PCA0CPHn = 0xFF). A 0% duty cycle may be generated by clearing the ECOMn bit to 0.
DutyCycle
256 PCA0CPHn ( )
256
--------------------------------------------------- =
Equation 23.2. 8-Bit PWM Duty Cycle
8-bit
Comparator
PCA0L
PCA0CPLn
PCA0CPHn
CEXn Enable
Overflow
PCA Timebase
0 0 x 0 x
Q
Q
SET
CLR
S
R
match
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
0
ENB
ENB
0
1
Write to
PCA0CPLn
Write to
PCA0CPHn
Reset
Crossbar Port I/O
Figure 23.8. PCA 8-Bit PWM Mode Diagram
C8051F020/1/2/3
258 Rev. 1.4
23.2.6. 16-Bit Pulse Width Modulator Mode
Each PCA0 module may also be operated in 16-Bit PWM mode. In this mode, the 16-bit capture/compare module
defines the number of PCA0 clocks for the low time of the PWM signal. When the PCA0 counter matches the module
contents, the output on CEXn is asserted high; when the counter overflows, CEXn is asserted low. To output a vary-
ing duty cycle, new value writes should be synchronized with PCA0 CCFn match interrupts. 16-Bit PWM Mode is
enabled by setting the ECOMn, PWMn, and PWM16n bits in the PCA0CPMn register. For a varying duty cycle,
CCFn should also be set to logic 1 to enable match interrupts. The duty cycle for 16-Bit PWM Mode is given by
Equation 23.3.
Important Note About Capture/Compare Registers: When writing a 16-bit value to the PCA0 Capture/Compare
registers, the low byte should always be written first. Writing to PCA0CPLn clears the ECOMn bit to 0; writing to
PCA0CPHn sets ECOMn to 1
Using Equation 23.3, the largest duty cycle is 100% (PCA0CPn = 0), and the smallest duty cycle is 0.0015%
(PCA0CPn = 0xFFFF). A 0% duty cycle may be generated by clearing the ECOMn bit to 0.
Equation 23.3. 16-Bit PWM Duty Cycle
DutyCycle
65536 PCA0CPn ( )
65536
----------------------------------------------------- =
Figure 23.9. PCA 16-Bit PWM Mode
PCA0CPLn PCA0CPHn
Enable
PCA Timebase
0 0 0 0 0
PCA0CPMn
P
W
M
1
6
n
E
C
O
M
n
E
C
C
F
n
T
O
G
n
P
W
M
n
C
A
P
P
n
C
A
P
N
n
M
A
T
n
1
16-bit Comparator
CEXn
Crossbar Port I/O
Overflow
Q
Q
SET
CLR
S
R
match
PCA0H PCA0L
C8051F020/1/2/3
Rev. 1.4 259
23.3. Register Descriptions for PCA0
Following are detailed descriptions of the special function registers related to the operation of PCA0.
Bit7: CF: PCA Counter/Timer Overflow Flag.
Set by hardware when the PCA0 Counter/Timer overflows from 0xFFFF to 0x0000. When the Coun-
ter/Timer Overflow (CF) interrupt is enabled, setting this bit causes the CPU to vector to the CF inter-
rupt service routine. This bit is not automatically cleared by hardware and must be cleared by
software. See Important Note About the PCA0CN Register on page 251.
Bit6: CR: PCA0 Counter/Timer Run Control.
This bit enables/disables the PCA0 Counter/Timer.
0: PCA0 Counter/Timer disabled.
1: PCA0 Counter/Timer enabled.
Bit5: UNUSED. Read = 0b, Write = don't care.
Bit4: CCF4: PCA0 Module 4 Capture/Compare Flag.
This bit is set by hardware when a match or capture occurs. When the CCF interrupt is enabled, set-
ting this bit causes the CPU to vector to the CCF interrupt service routine. This bit is not automati-
cally cleared by hardware and must be cleared by software.
Bit3: CCF3: PCA0 Module 3 Capture/Compare Flag.
This bit is set by hardware when a match or capture occurs. When the CCF interrupt is enabled, set-
ting this bit causes the CPU to vector to the CCF interrupt service routine. This bit is not automati-
cally cleared by hardware and must be cleared by software.
Bit2: CCF2: PCA0 Module 2 Capture/Compare Flag.
This bit is set by hardware when a match or capture occurs. When the CCF interrupt is enabled, set-
ting this bit causes the CPU to vector to the CCF interrupt service routine. This bit is not automati-
cally cleared by hardware and must be cleared by software.
Bit1: CCF1: PCA0 Module 1 Capture/Compare Flag.
This bit is set by hardware when a match or capture occurs. When the CCF interrupt is enabled, set-
ting this bit causes the CPU to vector to the CCF interrupt service routine. This bit is not automati-
cally cleared by hardware and must be cleared by software.
Bit0: CCF0: PCA0 Module 0 Capture/Compare Flag.
This bit is set by hardware when a match or capture occurs. When the CCF interrupt is enabled, set-
ting this bit causes the CPU to vector to the CCF interrupt service routine. This bit is not automati-
cally cleared by hardware and must be cleared by software.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
CF CR - CCF4 CCF3 CCF2 CCF1 CCF0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
(bit addressable) 0xD8
Figure 23.10. PCA0CN: PCA Control Register
C8051F020/1/2/3
260 Rev. 1.4
Figure 23.11. PCA0MD: PCA0 Mode Register
Bit7: CIDL: PCA0 Counter/Timer Idle Control.
Specifies PCA0 behavior when CPU is in Idle Mode.
0: PCA0 continues to function normally while the system controller is in Idle Mode.
1: PCA0 operation is suspended while the system controller is in Idle Mode.
Bits6-4: UNUSED. Read = 000b, Write = don't care.
Bits3-1: CPS2-CPS0: PCA0 Counter/Timer Pulse Select.
These bits select the timebase source for the PCA0 counter
Bit0: ECF: PCA Counter/Timer Overflow Interrupt Enable.
This bit sets the masking of the PCA0 Counter/Timer Overflow (CF) interrupt.
0: Disable the CF interrupt.
1: Enable a PCA0 Counter/Timer Overflow interrupt request when CF (PCA0CN.7) is set.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
CIDL - CPS2 CPS1 CPS0 ECF 01000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xD9
CPS2 CPS1 CPS0 Timebase
0 0 0 System clock divided by 12
0 0 1 System clock divided by 4
0 1 0 Timer 0 overflow
0 1 1
High-to-low transitions on ECI
(max rate = system clock divided by 4)
1 0 0 System clock
1 0 1
External clock divided by 8
1 1 0 Reserved
1 1 1 Reserved
The minimum high or low time for the ECI input signal is at least 2 system clock cycles.
External oscillator source divided by 8 is synchronized with the system clock.
C8051F020/1/2/3
Rev. 1.4 261
Figure 23.12. PCA0CPMn: PCA0 Capture/Compare Mode Registers
PCA0CPMn Address: PCA0CPM0 = 0xDA (n = 0)
PCA0CPM1 = 0xDB (n = 1)
PCA0CPM2 = 0xDC (n = 2)
PCA0CPM3 = 0xDD (n = 3)
PCA0CPM4 = 0xDE (n = 4)
Bit7: PWM16n: 16-bit Pulse Width Modulation Enable
This bit selects 16-bit mode when Pulse Width Modulation mode is enabled (PWMn = 1).
0: 8-bit PWM selected.
1: 16-bit PWM selected.
Bit6: ECOMn: Comparator Function Enable.
This bit enables/disables the comparator function for PCA0 module n.
0: Disabled.
1: Enabled.
Bit5: CAPPn: Capture Positive Function Enable.
This bit enables/disables the positive edge capture for PCA0 module n.
0: Disabled.
1: Enabled.
Bit4: CAPNn: Capture Negative Function Enable.
This bit enables/disables the negative edge capture for PCA0 module n.
0: Disabled.
1: Enabled.
Bit3: MATn: Match Function Enable.
This bit enables/disables the match function for PCA0 module n. When enabled, matches of the
PCA0 counter with a module's capture/compare register cause the CCFn bit in PCA0MD register to
be set to logic 1.
0: Disabled.
1: Enabled.
Bit2: TOGn: Toggle Function Enable.
This bit enables/disables the toggle function for PCA0 module n. When enabled, matches of the
PCA0 counter with a module's capture/compare register cause the logic level on the CEXn pin to tog-
gle. If the PWMn bit is also set to logic 1, the module operates in Frequency Output Mode.
0: Disabled.
1: Enabled.
Bit1: PWMn: Pulse Width Modulation Mode Enable.
This bit enables/disables the PWM function for PCA0 module n. When enabled, a pulse width modu-
lated signal is output on the CEXn pin. 8-bit PWM is used if PWM16n is logic 0; 16-bit mode is used
if PWM16n logic 1. If the TOGn bit is also set, the module operates in Frequency Output Mode.
0: Disabled.
1: Enabled.
Bit0: ECCFn: Capture/Compare Flag Interrupt Enable.
This bit sets the masking of the Capture/Compare Flag (CCFn) interrupt.
0: Disable CCFn interrupts.
1: Enable a Capture/Compare Flag interrupt request when CCFn is set.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
PWM16n ECOMn CAPPn CAPNn MATn TOGn PWMn ECCFn 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xDA-0xDE
C8051F020/1/2/3
262 Rev. 1.4
Bits 7-0: PCA0L: PCA0 Counter/Timer Low Byte.
The PCA0L register holds the low byte (LSB) of the 16-bit PCA0 Counter/Timer.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xE9
Figure 23.13. PCA0L: PCA0 Counter/Timer Low Byte
Bits 7-0: PCA0H: PCA0 Counter/Timer High Byte.
The PCA0H register holds the high byte (MSB) of the 16-bit PCA0 Counter/Timer.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xF9
Figure 23.14. PCA0H: PCA0 Counter/Timer High Byte
C8051F020/1/2/3
Rev. 1.4 263
Figure 23.15. PCA0CPLn: PCA0 Capture Module Low Byte
PCA0CPLn Address: PCA0CPL0 = 0xEA (n = 0)
PCA0CPL1 = 0xEB (n = 1)
PCA0CPL2 = 0xEC (n = 2)
PCA0CPL3 = 0xED (n = 3)
PCA0CPL4 = 0xEE (n = 4)
Bits7-0: PCA0CPLn: PCA0 Capture Module Low Byte.
The PCA0CPLn register holds the low byte (LSB) of the 16-bit capture module n.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xEA - 0xEE
PCA0CPHn Address: PCA0CPH0 = 0xFA (n = 0)
PCA0CPH1 = 0xFB (n = 1)
PCA0CPH2 = 0xFC (n = 2)
PCA0CPH3 = 0xFD (n = 3)
PCA0CPH4 = 0xFE (n = 4)
Bits7-0: PCA0CPHn: PCA0 Capture Module High Byte.
The PCA0CPHn register holds the high byte (MSB) of the 16-bit capture module n.
R/W R/W R/W R/W R/W R/W R/W R/W Reset Value
00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SFR Address:
0xFA - 0xFE
Figure 23.16. PCA0CPHn: PCA0 Capture Module High Byte
C8051F020/1/2/3
264 Rev. 1.4
Notes
C8051F020/1/2/3
Rev. 1.4 265
24. JTAG (IEEE 1149.1)
Each MCU has an on-chip JTAG interface and logic to support boundary scan for production and in-system testing,
Flash read/write operations, and non-intrusive in-circuit debug. The JTAG interface is fully compliant with the IEEE
1149.1 specification. Refer to this specification for detailed descriptions of the Test Interface and Boundary-Scan
Architecture. Access of the JTAG Instruction Register (IR) and Data Registers (DR) are as described in the Test
Access Port and Operation of the IEEE 1149.1 specification.
The JTAG interface is accessed via four dedicated pins on the MCU: TCK, TMS, TDI, and TDO.
Through the 16-bit JTAG Instruction Register (IR), any of the seven instructions shown in Figure 24.1 can be com-
manded. There are three DRs associated with JTAG Boundary-Scan, and four associated with Flash read/write oper-
ations on the MCU.
Figure 24.1. IR: JTAG Instruction Register
Reset Value
0x0000
Bit15 Bit0
IR Value Instruction Description
0x0000 EXTEST Selects the Boundary Data Register for control and observability of all device pins
0x0002
SAMPLE/
PRELOAD
Selects the Boundary Data Register for observability and presetting the scan-path
latches
0x0004 IDCODE Selects device ID Register
0xFFFF BYPASS Selects Bypass Data Register
0x0082 Flash Control
Selects FLASHCON Register to control how the interface logic responds to reads
and writes to the FLASHDAT Register
0x0083 Flash Data Selects FLASHDAT Register for reads and writes to the Flash memory
0x0084 Flash Address
Selects FLASHADR Register which holds the address of all Flash read, write, and
erase operations
C8051F020/1/2/3
266 Rev. 1.4
24.1. Boundary Scan
The DR in the Boundary Scan path is an 134-bit shift register. The Boundary DR provides control and observability
of all the device pins as well as the SFR bus and Weak Pullup feature via the EXTEST and SAMPLE commands.
Table 24.1. Boundary Data Register Bit Definitions
EXTEST provides access to both capture and update actions, while Sample only performs a capture.
Bit Action Target
0 Capture Reset Enable from MCU (C8051F021/3 devices)
Update Reset Enable to /RST pin (C8051F021/3 devices)
1 Capture Reset input from /RST pin (C8051F021/3 devices)
Update Reset output to /RST pin (C8051F021/3 devices)
2 Capture Reset Enable from MCU (C8051F020/2 devices)
Update Reset Enable to /RST pin (C8051F020/2 devices)
3 Capture Reset input from /RST pin (C8051F020/2 devices)
Update Reset output to /RST pin (C8051F020/2 devices)
4 Capture External Clock from XTAL1 pin
Update Not used
5 Capture Weak pullup enable from MCU
Update Weak pullup enable to Port Pins
6, 8, 10, 12, 14, 16,
18, 20
Capture P0.n output enable from MCU (e.g. Bit6=P0.0, Bit8=P0.1, etc.)
Update P0.n output enable to pin (e.g. Bit6=P0.0oe, Bit8=P0.1oe, etc.)
7, 9, 11, 13, 15, 17,
19, 21
Capture P0.n input from pin (e.g. Bit7=P0.0, Bit9=P0.1, etc.)
Update P0.n output to pin (e.g. Bit7=P0.0, Bit9=P0.1, etc.)
22, 24, 26, 28, 30,
32, 34, 36
Capture P1.n output enable from MCU
Update P1.n output enable to pin
23, 25, 27, 29, 31,
33, 35, 37
Capture P1.n input from pin
Update P1.n output to pin
38, 40, 42, 44, 46,
48, 50, 52
Capture P2.n output enable from MCU
Update P2.n output enable to pin
39, 41, 43, 45, 47,
49, 51, 53
Capture P2.n input from pin
Update P2.n output to pin
54, 56, 58, 60, 62,
64, 66, 68
Capture P3.n output enable from MCU
Update P3.n output enable to pin
55, 57, 59, 61, 63,
65, 67, 69
Capture P3.n input from pin
Update P3.n output to pin
70, 72, 74, 76, 78,
80, 82, 84
Capture P4.n output enable from MCU
Update P4.n output enable to pin
71, 73, 75, 77, 79,
81, 83, 85
Capture P4.n input from pin
Update P4.n output to pin
86, 88, 90, 92, 94,
96, 98, 100
Capture P5.n output enable from MCU
Update P5.n output enable to pin
87, 89, 91, 93, 95,
97, 99, 101
Capture P5.n input from pin
Update P5.n output to pin
102, 104, 106, 108,
110, 112, 114, 116
Capture P6.n output enable from MCU
Update P6.n output enable to pin
103, 105, 107, 109,
111, 113, 115, 117
Capture P6.n input from pin
Update P6.n output to pin
C8051F020/1/2/3
Rev. 1.4 267
24.1.1. EXTEST Instruction
The EXTEST instruction is accessed via the IR. The Boundary DR provides control and observability of all the
device pins as well as the Weak Pullup feature. All inputs to on-chip logic are set to logic 1.
24.1.2. SAMPLE Instruction
The SAMPLE instruction is accessed via the IR. The Boundary DR provides observability and presetting of the scan-
path latches.
24.1.3. BYPASS Instruction
The BYPASS instruction is accessed via the IR. It provides access to the standard JTAG Bypass data register.
24.1.4. IDCODE Instruction
The IDCODE instruction is accessed via the IR. It provides access to the 32-bit Device ID register.
Bit Action Target
118, 120, 122, 124,
126, 128, 130, 132
Capture P7.n output enable from MCU
Update P7.n output enable to pin
119, 121, 123, 125,
127, 129, 131, 133
Capture P7.n input from pin
Update P7.n output to pin
Table 24.1. Boundary Data Register Bit Definitions
Figure 24.2. DEVICEID: JTAG Device ID Register
Version = 0000b
Part Number = 0000 0000 0000 0011b (C8051F020/1/2/3)
Manufacturer ID = 0010 0100 001b (Silicon Labs)
Reset Value
Version Part Number Manufacturer ID 1 0xn0003243
Bit31 Bit28 Bit27 Bit12 Bit11 Bit1 Bit0
C8051F020/1/2/3
268 Rev. 1.4
24.2. Flash Programming Commands
The Flash memory can be programmed directly over the JTAG interface using the Flash Control, Flash Data, Flash
Address, and Flash Scale registers. These Indirect Data Registers are accessed via the JTAG Instruction Register.
Read and write operations on indirect data registers are performed by first setting the appropriate DR address in the
IR register. Each read or write is then initiated by writing the appropriate Indirect Operation Code (IndOpCode) to the
selected data register. Incoming commands to this register have the following format:
IndOpCode: These bit set the operation to perform according to the following table:
The Poll operation is used to check the Busy bit as described below. Although a Capture-DR is performed, no
Update-DR is allowed for the Poll operation. Since updates are disabled, polling can be accomplished by shifting in/
out a single bit.
The Read operation initiates a read from the register addressed by the DRAddress. Reads can be initiated by shifting
only 2 bits into the indirect register. After the read operation is initiated, polling of the Busy bit must be performed to
determine when the operation is complete.
The write operation initiates a write of WriteData to the register addressed by DRAddress. Registers of any width up
to 18 bits can be written. If the register to be written contains fewer than 18 bits, the data in WriteData should be left-
justified, i.e. its MSB should occupy bit 17 above. This allows shorter registers to be written in fewer JTAG clock
cycles. For example, an 8-bit register could be written by shifting only 10 bits. After a Write is initiated, the Busy bit
should be polled to determine when the next operation can be initiated. The contents of the Instruction Register
should not be altered while either a read or write operation is busy.
Outgoing data from the indirect Data Register has the following format:
The Busy bit indicates that the current operation is not complete. It goes high when an operation is initiated and
returns low when complete. Read and Write commands are ignored while Busy is high. In fact, if polling for Busy to
be low will be followed by another read or write operation, JTAG writes of the next operation can be made while
checking for Busy to be low. They will be ignored until Busy is read low, at which time the new operation will initi-
ate. This bit is placed ate bit 0 to allow polling by single-bit shifts. When waiting for a Read to complete and Busy is
0, the following 18 bits can be shifted out to obtain the resulting data. ReadData is always right-justified. This allows
registers shorter than 18 bits to be read using a reduced number of shifts. For example, the results from a byte-read
requires 9 bit shifts (Busy + 8 bits).
19:18 17:0
IndOpCode WriteData
IndOpCode Operation
0x Poll
10 Read
11 Write
19 18:1 0
0 ReadData Busy
C8051F020/1/2/3
Rev. 1.4 269
Figure 24.3. FLASHCON: JTAG Flash Control Register
This register determines how the Flash interface logic will respond to reads and writes to the FLASHDAT
Register.
Bit7: SFLE: Scratchpad FLASH Memory Access Enable.
When this bit is set, FLASH reads and writes are directed to the 128-byte Scratchpad FLASH sector.
When SFLE is set to logic 1, FLASH accesses out of the address range 0x00-0x7F should not be
attempted. Reads/Writes out of this range will yield unpredictable results.
0: FLASH access directed to the 64k byte Program/Data FLASH sector.
1: FLASH access directed to the 128 byte Scratchpad sector.
Bits6-4: WRMD2-0: Write Mode Select Bits.
The Write Mode Select Bits control how the interface logic responds to writes to the FLASHDAT
Register per the following values:
000: A FLASHDAT write replaces the data in the FASHDAT register, but is otherwise ignored.
001: A FLASHDAT write initiates a write of FLASHDAT into the memory address by the
FLASHADR register. FLASHADR is incremented by one when complete.
010: A FLASHDAT write initiates an erasure (sets all bytes to 0xFF) of the Flash page containing
the address in FLASHADR. The data written must be 0xA5 for the erase to occur.
FLASHADR is not affected. If FLASHADR = 0x7DFE - 0x7DFF, the entire user space will
be erased (i.e. entire Flash memory except for Reserved area 0x7E00 - 0x7FFF).
(All other values for WRMD3-0 are reserved.)
Bits3-0: RDMD3-0: Read Mode Select Bits.
The Read Mode Select Bits control how the interface logic responds to reads to the FLASHDAT Reg-
ister per the following values:
0000: A FLASHDAT read provides the data in the FASHDAT register, but is otherwise ignored.
0001: A FLASHDAT read initiates a read of the byte addressed by the FLASHADR register if no
operation is currently active. This mode is used for block reads.
0010: A FLASHDAT read initiates a read of the byte addressed by FLASHADR only if no
operation is active and any data from a previous read has already been read from
FLASHDAT. This mode allows single bytes to be read (or the last byte of a block) without
initiating an extra read.
(All other values for RDMD3-0 are reserved.)
Reset Value
SFLE WRMD2 WRMD1 WRMD0 RDMD3 RDMD2 RDMD1 RDMD0 00000000
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
C8051F020/1/2/3
270 Rev. 1.4
Figure 24.4. FLASHADR: JTAG Flash Address Register
This register holds the address for all JTAG Flash read, write, and erase operations. This register autoincrements
after each read or write, regardless of whether the operation succeeded or failed.
Bits15-0: Flash Operation 16-bit Address.
Reset Value
0x0000
Bit15 Bit0
Figure 24.5. FLASHDAT: JTAG Flash Data Register
This register is used to read or write data to the Flash memory across the JTAG interface.
Bits9-2: DATA7-0: Flash Data Byte.
Bit1: FAIL: Flash Fail Bit.
0: Previous Flash memory operation was successful.
1: Previous Flash memory operation failed. Usually indicates the associated memory location
was locked.
Bit0: BUSY: Flash Busy Bit.
0: Flash interface logic is not busy.
1: Flash interface logic is processing a request. Reads or writes while BUSY = 1 will not
initiate another operation
Reset Value
0000000000
Bit9 Bit0
C8051F020/1/2/3
Rev. 1.4 271
24.3. Debug Support
Each MCU has on-chip JTAG and debug logic that provides non-intrusive, full speed, in-circuit debug support using
the production part installed in the end application, via the four pin JTAG I/F. Silicon Labs' debug system supports
inspection and modification of memory and registers, breakpoints, and single stepping. No additional target RAM,
program memory, or communications channels are required. All the digital and analog peripherals are functional and
work correctly (remain synchronized) while debugging. The Watchdog Timer (WDT) is disabled when the MCU is
halted during single stepping or at a breakpoint.
The C8051F020DK is a development kit with all the hardware and software necessary to develop application code
and perform in-circuit debug with each MCU in the C8051F020 family. Each kit includes an Integrated Development
Environment (IDE) which has a debugger and integrated 8051 assembler. The kit also includes an RS-232 to JTAG
interface module referred to as the Serial Adapter, a target application board with a C8051F020 installed, RS-232 and
JTAG cables, and wall-mount power supply.
C8051F020/1/2/3
272 Rev. 1.4
Contact Information
Silicon Laboratories Inc.
4635 Boston Lane
Austin, TX 78735
Tel: 1+(512) 416-8500
Fax: 1+(512) 416-9669
Toll Free: 1+(877) 444-3032
Email: [email protected]
Internet: www.silabs.com
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holder.
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without
notice. Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences
resulting from the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the function-
ing of undescribed features or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon
Laboratories makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose,
nor does Silicon Laboratories assume any liability arising out of the application or use of any product or circuit, and specifically
disclaims any and all liability, including without limitation consequential or incidental damages. Silicon Laboratories products are
not designed, intended, or authorized for use in applications intended to support or sustain life, or for any other application in which
the failure of the Silicon Laboratories product could create a situation where personal injury or death may occur. Should Buyer
purchase or use Silicon Laboratories products for any such unintended or unauthorized application, Buyer shall indemnify and
hold Silicon Laboratories harmless against all claims and damages.