Cummins 6BTA5 inline 6-cylinder diesel turbocharged and after-cooled 102 1386 102 120 1500 6 17.6:1 16. 1800 6.545454545 Electronic 12V Volts DC Prime Rating fuel flow Maximum fuel flow, L / hr Maximum fuel inlet restriction, mm Hg Maximum fuel inlets temperature (degC) 45 8 71 (c)2012 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.

Uploaded by

mohsen_eng
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views

C90D5

Cummins 6BTA5 inline 6-cylinder diesel turbocharged and after-cooled 102 1386 102 120 1500 6 17.6:1 16. 1800 6.545454545 Electronic 12V Volts DC Prime Rating fuel flow Maximum fuel flow, L / hr Maximum fuel inlet restriction, mm Hg Maximum fuel inlets temperature (degC) 45 8 71 (c)2012 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.

Uploaded by

mohsen_eng
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Generator set data sheet

Model: Frequency: Fuel Type:

C90 D5 (6B) 50 Diesel

Spec sheet: Noise data sheet (Open/enclosed): Airflow data sheet: Derate data sheet (Open/enclosed): Transient data sheet:

SS28-CPGK ND50-CS550 AF50-550 TBD TD50-550

Standby

Prime kVA (kW) 82 (65.6) 1/2 2.5 11.5 3/4 3.8 17.1 Full 5.2 23.6 1/4 1.3 5.7 1/2 2.3 10.3 3/4 3.4 15.4 Full 4.7 21.2

Fuel consumption
Ratings Load gph L/hr

kVA (kW) 90 (72) 1/4 1.4 6.2

Engine
Engine manufacturer Engine model Configuration Aspiration Gross engine power output, kWm BMEP at set rated load, kPa Bore, mm Stroke, mm Rated speed, rpm Piston speed, m/s Compression ratio Lube oil capacity, L Overspeed limit, rpm Regenerative power, kW Governor type Starting voltage

Standby Rating Cummins 6BTA5.9 G5 Inline 6-Cylinder Diesel Turbocharged and After Cooled 102 1386 102 120 1500 6 17.6:1 16.4 1800 6.545454545 Electronic 12V Volts DC

Prime Rating

93 1265

Fuel flow
Maximum fuel flow, L/hr Maximum fuel inlet restriction, mm Hg Maximum fuel inlet temperature (C) 45 8 71

2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Document no. DS380-CPGK-RevA - 24/2/2012

Air
Combustion air, m 3/min Maximum air cleaner restriction, kPa

Standby Rating 131.00 6

Prime Rating 120.00

Exhaust
Exhaust gas flow at set rated load, m3/min Exhaust gas temperature, C Maximum exhaust back pressure, kPa 21.4 540 10.5 19.5 533

Standard set-mounted radiator cooling


Ambient design, C Fan load, KW m Coolant capacity (with radiator), L Cooling system air flow, m3/sec @ 12.7mmH2O Total heat rejection, BTU/min Maximum cooling air flow static restriction mmH2O 54 5.60992 19.75 3.44 9259 12.7 8419

Weights*
Unit dry weight kgs Unit wet weight kgs

Open 1244 1555

Enclosed 1944 2255

* Weights represent a set with standard features. See outline drawing for weights of other configurations

Dimensions
Standard open set dimensions Enclosed set standard dimensions

Length 2268 3151

Width 1094 1142

Height 1576 1714

Genset outline
Open set

Enclosed set

Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.

2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Document no. DS380-CPGK-RevA - 24/2/2012

Alternator data
Connection 1 Wye -3 phase 0 0 0 0 0 Temp rise C 163/125 0 0 0 0 0 Duty2 S/P 0 0 0 0 0 Alternator UCI224G 0 0 0 0 0 Voltage 380-415 0 0 0 0 0

Ratings definitions
Emergency Standby Power (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Limited-Time running Power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528. Prime Power (PRP) Base Load (Continuous) Power (COP) Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514.

Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.

Formulas for calculating full load currents:


Three phase output Single phase output

kWx1000 Voltagex1. 73x0.8

kWxSingleP haseFactor x1000 Voltage

See your distributor for more information. Cummins Power Generation Manston Park, Columbus Avenue Manston, Ramsgate Kent CT12 5BF, UK Telephone: +44 (0) 1843 255000 Fax: +44 (0) 1843 255902 E-Mail: [email protected] Web: www.cumminspower.com

2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Document no. DS380-CPGK-RevA - 24/2/2012