This document summarizes the results of a branch reinforcement check for a pipe to pipe branch header. It finds that: 1) The reinforcement area required for internal pressure is 190.0171 mm^2. 2) The available area without reinforcing is insufficient at 6. 3) A reinforcing pad is required as the reinforcement zone width is 8.51 mm. 4) With a reinforcing pad added, the available area is sufficient and the branch would be reinforced.

Uploaded by

viv0102
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
325 views

Reinforcement Check

This document summarizes the results of a branch reinforcement check for a pipe to pipe branch header. It finds that: 1) The reinforcement area required for internal pressure is 190.0171 mm^2. 2) The available area without reinforcing is insufficient at 6. 3) A reinforcing pad is required as the reinforcement zone width is 8.51 mm. 4) With a reinforcing pad added, the available area is sufficient and the branch would be reinforced.

Uploaded by

viv0102
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Branch Reinforcement Check

BY CHKD 1 DATE DATE 1/27/2010 1/27/2010

PRESSURE DESIGN OF PIPE TO PIPE BRANCH HEADER 6 3.404 1.920 50 122 168.3 250.3 1 0.4 0 0.64 BRANCH 6 3.404

NOMINAL BORE (INCHES) WALL THICKNESS (mm) P, DESIGN PRESSURE (N/mm2) DESIGN TEMP (OC) DESIGN TEMP (OF) D, PIPE OD (mm) ALLOWABLE STRESS, S (N/mm2) E, QUALITY FACTOR FROM TABLE 302.3.4 Y COEFFICIENT FROM TABLE 304.1.1 CORROSION ALLOWANCE (mm) PRESSURE DESIGN THICKNESS, t (mm) PD/2(SE+PY) 2

Th=

3.404

Tb=

3.404

D h=

Db=

1.920 50 122 168.3 IF PIPE < 14"THEN MANUALLY INPUT 250.3 1 0.4 0 0.64

th=

tb=

REINFORCEMENT AREA REQUIRED FOR INTERNAL PRESSURE = A1 A1 (mm2) = where

thd1(2-Sin) = = [Db-2(Tb-c)]/Sin 228.3842 45

d1= EFFECTIVE LENGTH REMOVED FROM PIPE AT BRANCH

= SMALLER ANGLE BETWEEN AXES OF BRANCH AND RUN

A1 (mm2) 3 4 AVAILABLE AREA WITHOUT REINFORCING PAD= A2+A3 A2 = AREA RESULTING FROM EXCESS THICKNESS IN THE RUN PIPE WALL A2 (mm2) d2 d2 d2 d2 (mm) THEREFORE A2 (mm2) 5 A3 = AREA RESULTING FROM EXCESS THICKNESS IN THE BRANCH PIPE WALL THEREFORE A3 (mm2) 2L4(Tb-tb-c)/Sin = = = (2d2-d1)(Th-th-c) "HALF WIDTH" OF REINFORCEMENT ZONE

190.0171

d1 or (Tb-c)+(Th-c)+d1/2 WHICHEVER IS THE GREATER BUT IN ANY CASE NOT MORE THAN D h = = = 228.3842 228.3842 630.4493 OR 121.0001

66.44445

6 7

REINFORCING PAD REQUIRED? REINFORCEMENT ZONE REINFORCEMENT ZONE IS A PARALLELOGRAM OF LENGTH 2d2 AND WIDTH L4 L4 = HEIGHT OF REINFORCEMENT ZONE OUTSIDE OF RUN PIPE OR = WHICHEVER IS LESS THEREFORE L4 (mm) = = =

NO

2.5(Th-c) 2.5(Tb-c)+Tr

8.51 8.51

8.51 0

Tr = MINIMUM THICKNESS OF REINFORCING PAD

A4 = AREA OF ANY OTHER METAL PROVIDED BY WELDS AND PROPERLY ATTACHED REINFORCEMENT A4 = (2d2-DbSin) x Tr 696.89375 = 367 % OF = A1 0 190.0171 YES

AVAILABLE AREA = A2+A3+A4 = 6

BRANCH SUFFICIENTLY REINFORCED WITH REINFORCING PAD?

Branch Reinforcement Check (Flange Rating)


BY CHKD 1 GK VC DATE DATE 1/27/2010 1/27/2010

PRESSURE DESIGN OF PIPE TO PIPE BRANCH HEADER 6 2.9785 2.940 50 122 168.3 216 1 0.4 1.5 1.14 BRANCH 6 2.9785

NOMINAL BORE (INCHES) WALL THICKNESS (mm) P, DESIGN PRESSURE (N/mm2) DESIGN TEMP (OC) DESIGN TEMP (OF) D, PIPE OD (mm) ALLOWABLE STRESS, S (N/mm2) E, QUALITY FACTOR FROM TABLE 302.3.4 Y COEFFICIENT FROM TABLE 304.1.1 CORROSION ALLOWANCE (mm) PRESSURE DESIGN THICKNESS, t (mm) PD/2(SE+PY) 2

Th=

3.404 10530

Tb=

3.404

D h=

Db=

2.940 50 122 168.3 IF PIPE < 14"THEN MANUALLY INPUT 216 1 0.4 0 1.14

th=

tb=

REINFORCEMENT AREA REQUIRED FOR INTERNAL PRESSURE = A1 A1 (mm2) = where

thd1(2-Sin) = = [Db-2(Tb-c)]/Sin 162.343 90

d1= EFFECTIVE LENGTH REMOVED FROM PIPE AT BRANCH

= SMALLER ANGLE BETWEEN AXES OF BRANCH AND RUN

A1 (mm2) 3 4 AVAILABLE AREA WITHOUT REINFORCING PAD= A2+A3 A2 = AREA RESULTING FROM EXCESS THICKNESS IN THE RUN PIPE WALL A2 (mm2) d2 d2 d2 d2 (mm) THEREFORE A2 (mm2) 5 A3 = AREA RESULTING FROM EXCESS THICKNESS IN THE BRANCH PIPE WALL THEREFORE A3 (mm2) 2L4(Tb-tb-c)/Sin = = = (2d2-d1)(Th-th-c) "HALF WIDTH" OF REINFORCEMENT ZONE

184.9367

d1 or (Tb-c)+(Th-c)+d1/2 WHICHEVER IS THE GREATER BUT IN ANY CASE NOT MORE THAN D h = = = 162.343 162.343 55.08739 OR 85.6285

13.59723

6 7

REINFORCING PAD REQUIRED? REINFORCEMENT ZONE REINFORCEMENT ZONE IS A PARALLELOGRAM OF LENGTH 2d2 AND WIDTH L4 L4 = HEIGHT OF REINFORCEMENT ZONE OUTSIDE OF RUN PIPE OR = WHICHEVER IS LESS THEREFORE L4 (mm) = = =

YES

2.5(Th-c) 2.5(Tb-c)+Tr

3.69625 7.44625

3.69625 0

Tr = MINIMUM THICKNESS OF REINFORCING PAD

A4 = AREA OF ANY OTHER METAL PROVIDED BY WELDS AND PROPERLY ATTACHED REINFORCEMENT A4 = (2d2-DbSin) x Tr 68.684616 = 37.1 % OF = A1 0 184.9367 NO

AVAILABLE AREA = A2+A3+A4 = 6

BRANCH SUFFICIENTLY REINFORCED WITH REINFORCING PAD?

You might also like