Samsung Option Code AC

This technical bulletin provides instructions for setting option codes on a Samsung unit when replacing a PCB board. The replacement PCB needs to be programmed using an infrared controller. Engineers should keep an infrared controller in their vans in case the unit is missing one. The steps include entering setup mode, inputting the first half of the option number, inputting the second half, checking the selections, and doing a test run.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
86% found this document useful (7 votes)
17K views

Samsung Option Code AC

This technical bulletin provides instructions for setting option codes on a Samsung unit when replacing a PCB board. The replacement PCB needs to be programmed using an infrared controller. Engineers should keep an infrared controller in their vans in case the unit is missing one. The steps include entering setup mode, inputting the first half of the option number, inputting the second half, checking the selections, and doing a test run.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Technical Bulletin

Number Subject Date 051 Setting up Samsung Option Codes May 2010

When replacing a PCB you will be issued with a universal replacement. This replacement PCB needs to be programmed with an infra red controller. Some systems may only have hard wired controllers installed and the infra red controller that came with the unit may be missing. Not all hard wired controllers allow the PCB function to be programmed. It is advised that engineers keep one of the infra red controllers on their vans at all times to ensure that this situation is avoided.

Step One Enter the option set up mode by removing the batteries from the controller. Re-insert the batteries whilst holding down the UP and DOWN arrows. The screen display should be as follows. If not, press MODE.

Technical Bulletin
Step Two
Enter the first half of the option number. In this example option number 045770Ic8000 is used. This will not be the option code you input. In Table One of the sequence below, The 0 represents the mode for the first half of the number to be inputted.

Technical Bulletin
Step Three
Enter the second half of the option number. In this example option number 045770-Ic8000 is used. This will not be the option code you input. In Table Seven of the sequence below, The 1 represents the mode for the second half of the number to be inputted.

Technical Bulletin
Step Four

Check your selection. Press the MODE key to select and check the first part of the sequence beginning with 0. Press the MODE key again to select and check the second part of the sequence beginning with 1.

Press the On/Off button. The unit will make a sound to confirm receipt of the instruction. Remove the batteries from the controller. No need to press any buttons. Re-insert the batteries. Point the controller at the unit and press the On/Off button to initiate TEST RUN.