0% found this document useful (0 votes)
45 views

Engineering Specification - G8S-5090-04 (Tank May Be In-Service or Out of Service)

This document provides a checklist for conducting an external visual examination of API-type tanks. The checklist includes 30 items to inspect such as process leaks, manways, flanges, bolting, shells, roofs, insulation, and foundation condition. For each item, the inspector indicates whether the condition is acceptable, unacceptable, or not applicable. Any comments by the inspector or engineering are also documented. Upon completion, the tank reliability and integrity section reviews and either accepts or rejects the findings, with the maintenance engineer providing final approval.

Uploaded by

Vineeth Chandran
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views

Engineering Specification - G8S-5090-04 (Tank May Be In-Service or Out of Service)

This document provides a checklist for conducting an external visual examination of API-type tanks. The checklist includes 30 items to inspect such as process leaks, manways, flanges, bolting, shells, roofs, insulation, and foundation condition. For each item, the inspector indicates whether the condition is acceptable, unacceptable, or not applicable. Any comments by the inspector or engineering are also documented. Upon completion, the tank reliability and integrity section reviews and either accepts or rejects the findings, with the maintenance engineer providing final approval.

Uploaded by

Vineeth Chandran
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

RELIABILITY MAINTENANCE DEPARTMENT ENGINEERING SPECIFICATION - G8S-5090-04

CHECKLIST FOR EXTERNAL VISUAL EXAMINATION OF ALL API - TYPE TANKS *

(Tank may be In-service or Out of Service)


EQUIPMENT:
SERVICE: INSPECTED BY: DATE: WORKORDER #:

LOCATION :

1/64" Line/Flaw Detected Cert.Level: VT Level II ITEM A U N 1. Process Leaks ( flanges, vents, etc.) 2. Weep Holes ( in reinforcing pads) 3. Manways / Nozzles 4. Flange Bolting (includes nuts) 5. Nut Thread Engagement 6. Shells(incl. Accessible ext. floaating roof tank interiors) 7. Manway Davits 8. Wind Girders 9. Overflows 10. Agitators / Mixers 11 Roofs (fixed) 12. Roof Drainage (water ponding on roof plates) 13. Stairways / Ladders / Platforms / Handrails 14. Tank Attachment Clips 15. Grounding Clips / Grounding Cable Attachment 16. Nameplates / Nameplate Brackets 17. Attachment Weld Spacing 18. Relief Devices ( vents, vacuum breakers, etc.) 19. Insulation 20. Insulation Support Rings (includes clips & bolting) 21. Paint / Protective Coating Deterioration 22. Patches 23. Shell-Bottom Junction / Chime 24. Anchor Bolting (includes nuts ) / Anchor Chairs 25. Foundation Condition 26. Tank Settling 27. Dikes / Dike Crossovers 28. Site Drainage 29. Area Housekeeping 30. Tank Shell Levelness Survey (external)
A = Acceptable U = Unacceptable N = Not Applicable

COMMENTS

E= Condition Accepted by Engineering

RESULT: T & I SECTION:

Accepted

Rejected

See the comments below

COMMENTS:_______________________________________________________ T & I INSPECTOR NAME & SIGN. :

Certification Level: VT-Level II DATE: NOTE: If any T&I section comments or rejection then this report to be submitted to MI Engineer for his decision and feed back. MI ENGINEER: Accepted Rejected See the comments below

COMMENTS: ______________________________________________________________

NAME & SIGNATURE: DATE: