Using EPANET For Irrigation System Design
Using EPANET For Irrigation System Design
WHAT IS IT?
EPANET is a Windows computer program that performs extended period simulation of hydraulic and water-quality behavior within pressurized pipe networks. A network can consist of pipes, nodes (pipe junctions), pumps, valves and storage tanks or reservoirs.
Program components
Lets check out the various components with a simple example. A gravity pipe running from a diversion to a pond
EXAMPLE PUMPED SYSTEM PROBLEM We are installing a pump in a stream to pump water to an on-farm irrigation system. After analyzing the on farm system, we have determined that the peak crop water requirement is 350 gpm and the pressure requirement at the turnout is 60 psi. The location of the pump and pipeline have already been surveyed. PVC pipe will be used. Pump site elevation = 3500 ft Determine the: 1. Pump selection to deliver the flow and pressure to the turnout 2. Pressure rating of the pipe 3. Daily electrical costs to run the pump
1 2 3 4 5 6 7 8 9 10 11 base
802.2700 815.1200 824.7000 1058.0700 1161.3700 1216.9900 1555.9200 1928.6900 2293.3500 2682.3300 2933.5500 5000.0000
1458.6700 1467.9300 1467.9400 1524.3300 1589.3400 1665.9100 1880.0600 2009.7200 2066.4500 2123.1800 2252.8400 5000.0000
100.0343 110.0037 110.2987 113.2476 115.3981 117.2178 119.3127 120.4318 125.2222 130.3264 150.5632 500.0000
[COORDINATES] 1 802.27 2 815.12 3 824.7 4 1058.07 5 1161.37 6 1216.99 7 1555.92 8 1928.69 9 2293.35 10 2682.33 11 2933.55
1458.67 1467.93 1467.94 1524.33 1589.34 1665.91 1880.06 2009.72 2066.45 2123.18 2252.84
Import file
Example: TDH= 200 ft Q = 400 gpm Pump Efficiency (from curve)= 75% Pump Motor Efficieny (assumed) = 85% NO VFD drive to pump (set motor rpm = 3600) WHP = (200 x 400)/ 3960 = 20.20 hp BHP = 20.2 / 75% = 26.94 hp EHP = 26.94/ 85% = 31.69 hp Water to wire Efficiency (pumping plant eff.) = 75% x 85% = 64% Assume you draw through the meter 30 hp (22.38 Kw) for 1 day. Assume the cost of electricity = $0.05 /Kw-hr To run the pump for 24 hours: 22.38 Kw x 24 hours x $0.05/Kw-hr = $26.86
DESIGN PARAMETERS TDH = 200 ft Q = 400 gpm
Meter VFD
BHP EHP
HP
To
i I rr
tio ga
Sy
em st
PUMP MOTOR
95-98 % eff.
80-90 % eff.
60-80 % eff.
PUMP
From Berkeley Pump Selection Software, Q = 350 gpm, TDH = 215 ft Power, hydraulic (water) : 18.97 hp Power, brake : 26.90 hp Minimum recommended driver rating set @ : 30.00 hp / 22.37 kW
P1 = 10 hp N1 = 3600 rpm N2 = 3200 rpm P2 = 7 hp An 11.1% speed decrease results in a 30% decrease in power Consumption! Small speed decreases result in large energy savings.
Example Bill
**Demand Charge is based on the highest average 15 minute power usage for the billing period. Demand charge kicks in at > 15 kw usage. (pacific power)
Pump Example
Calculate the Emitter Coeficients for the Varying Nozzles For the rainbird 30H (SBN-3) with plug @ 50 psi: 9/64 nozzle, C = q/p0.5 = 4.1 gpm/ 500.5 = 0.580 5/32 nozzle, C = 0.707