Basics of Optical Fiber Sensors
Basics of Optical Fiber Sensors
Measurements
Table of Contents
...................................................................................................................................................................1 1. Introduction to Optical Fiber Sensors...............................................................................................1 1.1 Fiber-Optic Sensing Basics.............................................................................................................1 1.2 Performance Parameters of Fiber-optic Sensors.............................................................................3
important information as to the amount of the strain to which different parts of the structure are subject to. FOS have also applications in biochemical sensing where they are used to measure physical parameters,such as temperature and pressure. They are also used to shape sensing systems to determine the precise position and shape of medical tools and robotic arms used during minimally invasive surgery. The intrinsic physical characteristics of optical fibers make them extremely attractive to biomedical sensing because their use will not interfere with conventional electronics found in medical equipments and their immunity to electromagnetic waves makes them ideal for real time use during diagnostic imaging with medical systems like Magnetic Resonance Imaging (MRI), Computer Tomography (CT) ,Positron Emission Tomography (PET ), etc...([2]). An optical fiber sensing system consists of four basic components, namely: a light source, optical fiber, transducer and a detector ([3]). The transducer modulates some parameter of the optical system that can be measured such as intensity, wavelength, polarization and phase. fiber sensor
source detector
Fig. 1: A basic FOS scheme The physical parameter to be measured is introduced in terms of acoustic wave, flow, temperature, electric filed, magnetic field, electric current, gas radiation, etc. Then the transducing occurs along the fiber in the form of electro-optic effect, thermal expansion, Raman scattering, Brillouin scattering, Flourescense. This results in a change in the characteristics of the optical signal received at the detector. There are many categories of FOS based on the part of the sensor used for classification [4]. They can be classified as intensity, phase, frequency or polarization sensors based on the modulation and demodulation process. Phase or frequency sensors are also called interferometric sensors because interferometric techniques are needed to detect these parametes which also implies coherent hetrodyne detection. Coherent sensors are more complex in design than Intensity (incoherent) sensors. Based on their application, FOS can be classified as physical sensors (measurement of temperature, stress, etc...): chemical sensors, (measurement of PH content, spectroscopic studies), bio-medical sensors, etc... FOS can also be classified as intrinsic or extrinsic, based on how the modulation takes place. In intrinsic sensors, the modulation takes place directly in the fiber while in extrinsic sensors the modulation is performed by an external transducer. Another main classification is into discrete (point) and distributed sensors. In distributed sensing,
scattering phenomena in the fiber such as Rayleigh, Raman and Brillouin scattering are used to determine the measurand (temperature, strain) and the fiber is used to continuously determine the value of the parameter along the entire sensing span. In discrete (point) sensing, however, the measurement of parameters is performed at predetermined points along the fiber where Fiber Brag Gratings (FBGs) are located. Discrete sensors can also be multiplexed so that an array of FBG is placed and interrogated using a shared source and detector. A combination of point and distributed sensors gives rise to what are known as hybrid distributed/point sensors which are used to simultaneously measure such parameters as temperature and pressure both over the entire fiber or at discrete points along its span. Fig. 2 gives the basic block diagram of these two types of FOS.
(a)
(b) Fig. 1: Basic block diagrams of (a) a multiplexed discrete and (b) a distributed FOS, system.
system is able to indicate the value of the measurand within the specified uncertainty (measuring spatial resolution) or as the minimum distance that generates results which are within 10% of the measurand transition amplitude (detection spatial resolution).
Sensitivity This is the change of a measured variable produced by a unit change of the measured value of the environment. It is given by %/oC for temperature or Mhz/ micros-strain for strain. Sensing Range It is the fiber length over which meausremtns can be performed within stated sensing performance. Measurand Resolution The measurand resolution is smallest difference in the measured parameter which the sensor can detect. It is defined as the estimated standard deviation of a specified series of measurements given as a function of the distance for a particular spatial resolution and acquisition time. Dynamic Range The ration of the largest power and smallest value of the measured field that could be observed by the sensing scheme, with a required accuracy. Measurement time This is the time the system need to obtain results within a set of particular sensing performances Accuracy The accuracy in measuring an environmental parameter is the measure of nearness of the measured value with the sensor with the actual value. Cross-sensitivity It indicates how much the measurement is influenced by other environmental parameters different from the actual measurand, that affect the mechanism used for sensing.
References
[1]. Fidanboylu, K.,Efendiolu, H. S.,Fatih University, Istanbul, Turkey, Fatih University, Istanbul, Fiber Optic Sensors and their Applications-Keynote Address, International Advanced Technologies Symposium (IATS09), May 13-15, 2009, Karabuk, Turkey [2]. http://www.laserfocusworld.com/articles/2011/01/medical-applications-of-fiber-optics-opticalfiber-sees-growth-as-medical-sensors.html [3] http://www3.ntu.edu.sg/mae/research/programmes/sensors/sensors/fos/fosselva.html [4].http://www.micronoptics.com/uploads/library/documents/Micron%20Optics%20Optical %20Sensing%20Guide.pdf