Simple Rankine Cycle Analysis: 1 Pump in 7 Pump Out 6 Boiler 5 Boiler 3 Turbine in 4 Turbine Out 2 Pump in

This document provides instructions and examples for analyzing a simple Rankine cycle. It includes a sample problem table with temperature, pressure, enthalpy and other values at different points in the cycle. Charts are also included showing the temperature-entropy and pressure-specific volume diagrams for the Rankine cycle. Properties of water at different saturation conditions like temperature, pressure, specific volume and entropy are listed in a table. The document also provides an example of using the THprops syntax to look up fluid properties and sensitivity study results for the dependent variable (efficiency) with changing independent variables (pressure, entropy, etc.).

Uploaded by

bincoleto5536
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Simple Rankine Cycle Analysis: 1 Pump in 7 Pump Out 6 Boiler 5 Boiler 3 Turbine in 4 Turbine Out 2 Pump in

This document provides instructions and examples for analyzing a simple Rankine cycle. It includes a sample problem table with temperature, pressure, enthalpy and other values at different points in the cycle. Charts are also included showing the temperature-entropy and pressure-specific volume diagrams for the Rankine cycle. Properties of water at different saturation conditions like temperature, pressure, specific volume and entropy are listed in a table. The document also provides an example of using the THprops syntax to look up fluid properties and sensitivity study results for the dependent variable (efficiency) with changing independent variables (pressure, entropy, etc.).

Uploaded by

bincoleto5536
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

Simple Rankine Cycle Analysis

Instructions

Fill In
Problem
Rankine
Lookup
Step
1 Pump in
7 Pump out
6 Boiler
5 Boiler
3 Turbine In
4 Turbine Out
2 Pump in

Sensitivity Study

TF Props: TFProps (Substance ID (=40 for


water), Unit ID (= "SI_C" for Celsius), 1st
Property ID (Input), 1st Property Value
(Input), 2nd Property ID (Input), 2nd Property
Value (Input), 3rd Property ID (Output)).

Sample Problem
T [oC]

P [Pa]

P [bars]

v [m3/kg]

hin

hout

s [kJ/kgK]

h [kJ/kg]

1
2
2a
2b
3
4
1

Pump
Boiler
Turbine
Condenser

2
Sums =

0.0

Q
in

2a

0.0

Pump

Eta =
BWR =

Boiler
2b

W
pump

W
turbine

Turbine

1
Condenser

Q
out
P- v Diagram for Rankine Cycle

T- s Diagram for Rankine Cycle

1000

500
450

350
300
250
200
150

Column A
Column A
Column D
Column D
Column D
Column D

100
Pressure [bars]

Te mpe rature [oC]

400

Column B
Column F

Column B
Column F

Column F
Column F

10

Prepared by Robert J. Ribando 03/26/2013


1

Page 1

1000

500

Column B
Column F

450
Column A
Column A
Column D
Column D
Column D
Column D

350
300
250

100
Pressure [bars]

Te mpe rature [oC]

400

200
150
100
50
0
0

0.43

Dependent Variable

0.42
0.41
0.4

e11
eta
2000000
0.4
2150000
0.4
2300000
0.4
2450000
0.4
2600000
0.4
2750000
0.41
2
3
4
5
6
7
2900000
0.41
Entropy [kJ/kgK]
3050000
0.41
3200000
0.41
Sensitivity
3350000
0.41 Study
3500000
0.41
3650000
0.42
3800000
0.42
3950000
0.42
4100000
0.42
4250000
0.42
4400000
0.42
4550000
0.42
4700000
0.42
4850000
0.43
5000000
0.43

Column B
Column F

Column F
Column F

10

0.1

0.01
8

10

0.01

0.1

10

100

Specific Volume [m3/kg]

0.39
0.38
0.37
1000000

2000000

3000000

4000000

5000000

6000000

Independent Variable

Prepared by Robert J. Ribando 03/26/2013

Page 2

Props (Substance ID (=40 for


D (= "SI_C" for Celsius), 1st
nput), 1st Property Value
operty ID (Input), 2nd Property
3rd Property ID (Output)).

nB
nF

W
turbine

Column F
Column F

Prepared by Robert J. Ribando 03/26/2013

Page 3

nB
nF

10

Column F
Column F

100

Prepared by Robert J. Ribando 03/26/2013

Page 4

Example of Thprop Syntax


Fluid =
40 (water)
Pressure = 4000000
[Pa]
Entropy =
0.64 [kJ/kgK]
Specific Volume =
#NAME? [m3/kg]

Saturation Properties of Water


Temp
Pressure
[oC]
[bars]
0.01
0.01
4
0.01
5
0.01
6
0.01
8
0.01
10
0.01
11
0.01
12
0.01
13
0.01
14
0.02
15
0.02
16
0.02
17
0.02
18
0.02
19
0.02
20
0.02
21
0.02
22
0.03
23
0.03
24
0.03
25
0.03
26
0.03
27
0.04
28
0.04
29
0.04
30
0.04
31
0.04
32
0.05
33
0.05
34
0.05
35
0.06
36
0.06
38
0.07
40
0.07
45
0.1
50
0.12
55
0.16
60
0.2
65
0.25
70
0.31
75
0.39
80
0.47
85
0.58
90
0.7
95
0.85
100
1.01
110
1.43
120
1.99

vf
m /kg
3

0
157.23
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

vg x 103
m /kg
206.14
3

147.12
137.73
120.92
106.38
99.86
93.78
88.12
82.85
77.93
73.33
69.04
65.04
61.29
57.79
54.51
51.45
48.57
45.88
43.36
40.99
38.77
36.69
34.73
32.89
31.17
29.54
28.01
26.57
25.22
23.94
21.6
19.52
15.26
12.03
9.57
7.67
6.2
5.04
4.13
3.41
2.83
2.36
1.98
1.67
1.21
0.89

Entropy sf Entropy sg
kJ/kgK
0
0.06
0.07
0.09
0.12
0.15
0.16
0.18
0.19
0.21
0.22
0.24
0.25
0.26
0.28
0.29
0.31
0.32
0.34
0.35
0.36
0.38
0.39
0.41
0.42
0.43
0.45
0.46
0.48
0.49
0.5
0.52
0.54
0.57
0.64
0.7
0.77
0.83
0.89
0.96
1.02
1.08
1.14
1.19
1.25
1.31
1.42
1.53

kJ/kgK
9.16
9.05
9.02
9
8.95
8.9
8.88
8.85
8.83
8.8
8.78
8.76
8.73
8.71
8.69
8.67
8.64
8.62
8.6
8.58
8.56
8.54
8.51
8.49
8.47
8.45
8.43
8.41
8.39
8.37
8.35
8.33
8.29
8.26
8.16
8.08
7.99
7.91
7.83
7.75
7.68
7.61
7.54
7.48
7.42
7.35
7.24
7.13

130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
320
340
360
374.1

2.7
3.61
4.76
6.18
7.92
10.02
12.54
15.54
19.06
23.18
27.95
33.44
39.73
46.89
54.99
64.12
74.36
85.81
112.74
145.86
186.51
220.8

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

0.67
0.51
0.39
0.31
0.24
0.19
0.16
0.13
0.1
0.09
0.07
0.06
0.05
0.04
0.04
0.03
0.03
0.02
0.02
0.01
0.01
0

1.63
1.74
1.84
1.94
2.04
2.14
2.24
2.33
2.42
2.52
2.61
2.7
2.79
2.88
2.98
3.07
3.16
3.25
3.45
3.66
3.91
4.35

7.03
6.93
6.84
6.75
6.67
6.58
6.51
6.43
6.36
6.29
6.21
6.14
6.07
6
5.93
5.86
5.78
5.7
5.54
5.33
5.05
4.48

You might also like