Pressure Drop Cal (1) - STD
Pressure Drop Cal (1) - STD
EQUIPMENT SIZE SERVICE Bombay Chemcial Equipments Y type strainer 80 NB ACID 10 6 1137 400 6 40 40 0.16 63 In m3/hr. In cP. In Kg/m3 In Microns In mm. In % In % 2777.778 0.06 1.137 40 0.6 0.4 0.4 In Cm3/sec. In gm/cm-sec In gm/cc In Mesh In cm.
FLOW RATE() (80,000 cfh) VISCOSITY () DENSITY (r) DEGREE OF FILTERATION OPENING WIDTH (Da) % OPENING IN WIRE MESH (a) % OPENING IN PERFORATED SHEET(g) (6 DIA. HOLE & 9 mm PITCH.) EFFECTIVE OPENING, a = (a x g) SIZE OF ELEMENT (DRG. NO.) GROSS BASKET AREA, A1=(D1L) NET BASKET AREA, A2 = A1 x a VELOCITY n = /A2 REYNOLDS NO. Nre=rnDa/a CO-EFFICIENT OF DISCHARGE (C) (From Perry Page No. 5 40) (Copy Enclosed) PRESSURE DROP 1 1 - a2 V2 __ x ____ x ____ C2 a2 2g PRESSURE DROP ACROSS ELEMENT
In % Long In mm
593.46 94.9536
In cm2 In cm2
Pressure Drop Required In Clean Condition Is 0.01 Kg/cm2 Since The Actual Pressure Drop Is Well Within Limits.