Design of Purlins
Design of Purlins
SAFE 10 1 5 2.5 m m m
5000 2500
mm mm
Load Calculation a. DL Wt. of sheeting = Assuming ISMC 100 Self Wt = 0.1 KN/m2 b. LL LL on Sheeting = DL + LL = 1.6 KN/m
0.75 0.1
KN/m2 KN/m2
0.75
KN/m2
Resolving the DL+LL into components along x-x and y-y Load x-x Load y-y = = 0.277872743 1.575686117 KN/m KN/m
c.WL Wind Pressure = Positive wind coefficient = WL on Purlins = TL x-x = TL y-y = Mx-x = My-y = Section Properties Area = Zx-x = Zy-y = rx-x = ry-y = slenderness ratio x-x slenderness ratio y-y Allowable Stress x-x= Allowable Stress y-y= Stress Developed x-x = Stress Developed y-y = Maximum bending stress = Maximum allowable = Hence the design is SAFE 0.3645 0.28 1.940186117 6.063081615 0.21875
KN/m2
6063081.615 218750
N-mm N-mm
N/mm2 N/mm2 162.549105 29.1666667 191.715772 219.45 N/mm2 N/mm2 N/mm2 N/mm2