The document outlines the agenda for a three-day Machine Protection Training seminar provided by Siemens. Day 1 will cover introductions and basics of machine protection, as well as demonstrations of stator and rotor earth fault protection. Day 2 focuses on synchronous machine operation and stability, under excitation protection, and out of step protection with practical demonstrations. Day 3 includes differential protection for generators and transformers, generator startup protection, and setting examples with analysis of fault records. The training will provide an introduction to Siemens' machine protection solutions and teach techniques for protecting energy generation and transmission equipment.

Uploaded by

reza515hei
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views

Introduction Machine Protection

The document outlines the agenda for a three-day Machine Protection Training seminar provided by Siemens. Day 1 will cover introductions and basics of machine protection, as well as demonstrations of stator and rotor earth fault protection. Day 2 focuses on synchronous machine operation and stability, under excitation protection, and out of step protection with practical demonstrations. Day 3 includes differential protection for generators and transformers, generator startup protection, and setting examples with analysis of fault records. The training will provide an introduction to Siemens' machine protection solutions and teach techniques for protecting energy generation and transmission equipment.

Uploaded by

reza515hei
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Machine Protection Training

Welcome

Siemens solutions: Answers for energy

We offer the broad range from energy generation to energy consumption

Energy

Energy

Products, services & solutions


Generation Transmission Distribution Consumption

Our Offerings

Energy Automation Information andWe supply network control intelligent energy technologyautomation products
and systems including protection Protection and power quality relays, substation automation, instruments, telecontrol systems, protection panels, power quality substation control and SCADA equipment.

Energy Transmission & Energy Distribution Contacts


Bradley Lubbe Ph: +61 (8) 9241-4464 Mob: +61 (418) 139-473 Email: [email protected] Derek Haas Ph: +61 (0)7 3332 8396 Mob: +61 (0)458 057 539 Email: [email protected]

Noel Gallagher Ph: +61 (0)3 9721 2606 Mob: +61 (0)439 311 218 Email: [email protected]

Dennis Sandrone Ph: +61 (0)2 9491 5691 Mob: +61 (0)409 330 025 Email: [email protected]

Agenda

Day 1 Agenda 9.00am Registration & Introduction Introduction to Siprotec Relay Family Introduction to Machine Protection Break Basic Stator Earth Fault Protection - General; displacement voltage - Unit connected machines - Bus bar connected machines - Practical demonstration Lunch 100% Stator Earth Fault - Principle - Practical demonstration Afternoon Tea Rotor Earth Fault Protection - Current measurement (IEE>) - Resistance measurement (R/fn) - Resistance measurement (1 3 Hz) - Practical demonstration

10.00am 10.30am

12.00am 1.00pm

3.00pm 3.30pm

Agenda

Day 2 Agenda 9.00am Synchronous Machines basics - Operation parallel with network - Isolated operation - Stability limits - Reactances Break Under Excitation - Admittance plane - Comparison admittance principle - Bus bar connected machines - Practical demonstration - Analysing a Fault Record using SIGRA 4 Lunch Out of Step - Principle - Practical demonstration - Analysing a Fault Record using SIGRA 4 Afternoon Tea CT Dimensioning

10.00am 10.30am

12.00am 1.00pm

3.00pm 3.30pm

Agenda

Day 3 Agenda 9.00am 10.00am 10.30am Differential Protection - Generator Differential Break Differential Protection - Transformer Differential - Practical demonstration Generator Startup Protection Lunch Setting Examples - Principle - Practical demonstration - Analysing a Fault Record using SIGRA 4 Afternoon Tea Setting Examples continued

11.30am 12.30am 1.30pm

3.00pm 3.30pm