Specification - AC Voltage With Adjustable Differential: 252-PVU 252-PVO 252-PVV 252-PVP 252-PVK 252-PVA

This document provides specifications for an AC voltage monitoring device with adjustable differential, including: 1) It monitors nominal voltages of 100-440V at frequencies of 45/65Hz or 360/440Hz with an adjustable trip level of 75-125% and differential of 1-15%. 2) It has an overload rating of 1.2-1.5 times the nominal rating, repeatable settings, and auxiliary supply voltages of 12-125V. 3) It provides form C relay outputs rated for 5A loads with a mechanical life of 0.2 million operations, and has dimensions of 55x70x112mm or 75x70x112mm weighing 0.4-0.6kg.

Uploaded by

mbing_ikan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views1 page

Specification - AC Voltage With Adjustable Differential: 252-PVU 252-PVO 252-PVV 252-PVP 252-PVK 252-PVA

This document provides specifications for an AC voltage monitoring device with adjustable differential, including: 1) It monitors nominal voltages of 100-440V at frequencies of 45/65Hz or 360/440Hz with an adjustable trip level of 75-125% and differential of 1-15%. 2) It has an overload rating of 1.2-1.5 times the nominal rating, repeatable settings, and auxiliary supply voltages of 12-125V. 3) It provides form C relay outputs rated for 5A loads with a mechanical life of 0.2 million operations, and has dimensions of 55x70x112mm or 75x70x112mm weighing 0.4-0.6kg.

Uploaded by

mbing_ikan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Specification AC Voltage with Adjustable Differential

Nominal voltage System frequency Voltage burden Overload Set point repeatability Differential (hysteresis) Trip level adjustment 100V, 110V, 120V, 208V, 220V, 270V, 280V, 400V, 415V or 440V 45/65Hz or 360/440Hz 0.3VA approx. 1.2 x rating continuously, 1.5 x rating for 10 x seconds >0.5% of full span Adjustable range 1 to 15% Under-voltage: 75 to 100% Over-voltage: 100 to 125% of nominal input voltage Factory pre-set up to 30 seconds 100V, 110V, 120V, 208V, 220V, 240V, 480V, 20% 12V, 24V, 48V, 110V or 125V, 15%. Max ripple 15% 4VA (max) 2-pole change over AC: 240V 5A, non inductive DC: 24V, 5A resistive 0.2 million operations at rated loads Automatic 0C to +60C (0C to +40C for UL models) 20C to +70C 0.05% per C Electrical stress surge withstand and non-function to ANSI/IEEE C37 90a DIN rail with wall mounting facility Flame retardant polycarbonate/ABS IP50 EMC, LVD, Safety Standard IEC 414 UL File No: E113067 recognised up to 600V CSA File No: LR52592 up to 300V BV File No: 2650H-07427-AO PRSO BV (Model 253 only) ABS File No: 93-LD 17806-X (Model 253 only) 55mm (2.2") wide x 70mm (2.8") high x 112mm (4.4") deep 75mm (2.9") wide x 70mm (2.8") high x 112mm (4.4") deep Model 252: 0.4Kg approx. Model 253: 0.6Kg approx.

Time delay AC auxiliary supply voltage DC auxiliary supply voltage Auxiliary voltage burden Output relay Relay contact rating Relay mechanical life Relay reset Operating temperature Storage temperature Temperature co-efficient Interference immunity Enclosure style Material Enclosure integrity Compliant with

Connections
252-PVU 252-PVO 252-PVV 252-PVP 252-PVK 252-PVA
Relay Contact Set 1 Contact Set 2

3-phase Input Aux supply L N when Single-phase Input required

253-PVB
Under Relay Contact Set 1 Over Relay Contact Set 1

Model 252 dimensions Model 253 dimensions Weight

Under Relay Contact Set 2

Input

Over Relay Contact Set 2

Dimensions
Model 252
55mm (2.2) 112mm (4.4) 55mm (2.2) 70mm (2.8) 35mm (1.37) 12mm (0.5) 2 HOLES 4.1

253-PVE 253-PVM
Input

(1.37)

35mm

17.5mm (0.68)

35mm (1.37)

RELEASE CLIP

15.5mm (0.6)

Input

Model 253
75mm (2.9) 112.5mm (4.4) 60mm (2.4)

Note: The neutral connection is always used on four-wire systems.


50mm (1.96) 60mm

70mm (2.8)

(1.37)

35mm

RELEASE CLIP

2 FIXING HOLE 'A' TO SUIT M4

2 FIXING HOLE 'A' TO SUIT M4

(2.36)