0% found this document useful (0 votes)
56 views

Project Example 2

This document contains plans and details for a proposed residential site development including: - A site and drainage plan showing the layout of the property with lot boundaries, building footprint, drainage infrastructure and spot elevations. - Details for typical sections of trap gully basins, grease traps, lintels and beams. - A ground floor plan showing the layout and dimensions of rooms, doors, windows and structural elements. - A proposed roof framing plan showing the layout of roof trusses and purlins.

Uploaded by

dervingame
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Project Example 2

This document contains plans and details for a proposed residential site development including: - A site and drainage plan showing the layout of the property with lot boundaries, building footprint, drainage infrastructure and spot elevations. - Details for typical sections of trap gully basins, grease traps, lintels and beams. - A ground floor plan showing the layout and dimensions of rooms, doors, windows and structural elements. - A proposed roof framing plan showing the layout of roof trusses and purlins.

Uploaded by

dervingame
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Scale: 1:100

SITE & DRAINAGE PLAN


1
V
A
L
E
R
I
E

C
R
E
S
C
E
N
T
CLAYTONVILLE DRIVE
LOT # 1047
LOT # 1045
LOT # 1044
BOUNDARY
B
O
U
N
D
A
R
Y
1
3
6
5
0
[
4
5
'-
6
"
]
1190
[4']
3002
[10']
1
2
0
0
[
4
']
4278
[14'-3"]
1
2
0
0
0
[
4
0
']
MASTER SUITE
BEDROOM
# 1
WALK-IN
CL
KITCHEN
LIVING
&
DINING
ENTERTAINMENT
ROOM
BEDROOM
# 2
BEDROOM
# 3
BATH
ROOM
# 2
HALL
WASH
ROOM
BACK
PATIO
MASTER
BATH
ROOM
# 1
B
O
U
N
D
A
R
Y
ABSORPTION
PIT
13321
[44'-5"]
2
4
3
8
4
[
8
1
'-
3
"
]
2
7
1
5
8
[
9
0
'-
6
"
]
400
[1'-4"]
3150
[10'-6"]
400
[1'-4"]
16620
[55'-5"]
4
3
1
0
[
1
4
'-
4
"]
M
400
[1'-4"]
12000
[40']
M.H
M.H
M.H
M.H
M.H
G.T
T.G.B
T.G.B
M.H
(3") 75 dia.
pvc pipe
(4") 100 dia. pvc pipe
(
4
")
1
0
0
d
ia
. p
v
c
p
ip
e
(
4
")
1
0
0
d
ia
. p
v
c
p
ip
e
(
4
")
1
0
0
d
ia
. p
v
c
p
ip
e
(3") 75 dia.
pvc pipe
(3") 75 dia.
pvc pipe
G.T
(3") 75 dia.
pvc pipe
400
[1'-4"]
9261
[30'-10"]
400mm sq.
column set at
3000 mm
400mm sq.
column set at
3000 mm
400mm sq.
column set at
3000 mm
SEPTIC
TANK
3
0
0
0
[
1
0
']
M.H
(4") 100 dia. pvc pipe
(
4
")
1
0
0
d
ia
. p
v
c
p
ip
e
3
5
8
0
[
1
1
'-
1
1
"
]
3
0
0
0
[
1
0
']
3000
[10']
3
0
1
6
[
1
0
'-
1
"
]
3
0
0
0
[
1
0
']
3
0
0
0
[
1
0
']
1
6
5
0
[
5
'-
6
"
]
3300
[11']
(4") 100 dia.
pvc pipe
FRONT
PATIO
150 MM
THICK
BELT
BEAM
150 MMTHICK
BELT BEAM
150 MM
THICK
BELT
BEAM
150 MM
THICK
BELT
BEAM
Not Drawn to Scale
SITE LOCATION
1
LOT #
1046
PROPOSED
PROPERTY
KEY:
DIRECTION TO
PROPERTY
St. John's Rd
F
ea
th
er
b
ed
L
n
Patricia Parkway
F
e
a
t
h
e
r
b
e
d
L
n
Innswood Boulevard
Valerie
Crescent
Merryfield
Drive
Clayton
Drive
Brookville
Avenue
cast iron
duty basin
cover & frame
75
[3"]
375
[1'-3"]
75
[3"]
75 mm CL
& W pipe
Scale: 1:10
TYPICAL SECT. TRAP GULLY BASIN
1
9
0
[
4
"
]
2
8
5
[
1
1
"
]
7
5
[
3
"
]
cast iron
duty basin
cover & frame
75
[3"]
375
[1'-3"]
75
[3"]
375
[1'-3"]
75
[3"]
7
5
[
3
"
]
3
2
9
[
1
'-
1
"
]
7
2
[
3
"
]
1
5
9
[
6
"
]
r .. ,.,
75 mm CL & W pipe
GL
1:2:4 reinf'd conc.
mix. with steel finish
to internal walls
Scale: 1:10
TYPICAL SEC THRU GREASE TRAP
1
Scale: 1:10
GREASE TRAP PLAN
1
r .. ,.,
75 mm CL & Wpipe
75
[3"]
375
[1'-3"]
75
[3"]
375
[1'-3"]
75
[3"]
975
[3'-3"]
7
5
[
3
"
]
3
7
5
[
1
'-
3
"
]
7
5
[
3
"
]
5
2
5
[
1
'-
9
"
]
Scale: 1:10
TRAP GULLY BASIN PLAN
1
75 mm CL & Wpipe
375
[1'-3"]
75
[3"]
525
[1'-9"]
75
[3"]
7
5
[
3
"
]
3
7
5
[
1
'-
3
"
]
7
5
[
3
"
]
5
2
5
[
1
'-
9
"
]
3
0
0
[
1
']
150
[6"]
Scale: 1:10
LINTEL DETAIL
1
10 mm
bar @ 300
crs.
4 #
12mm
dia bars
3
0
0
[
1
']
150
[6"]
Scale: 1:10
BEAM DETAIL
1
10 mm
bar @ 300
crs.
4 #
12mm
dia bars
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
1/8
SHEET NAME
SITE & DRAINAGE PLAN, SITE
LOCATION, BEAM & LINTEL DETAIL,
TYPICAL SEC THRU GREASE TRAP &
PLAN, TYPICAL SECT. TRAP GULLY
BASIN & PLAN
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
Scale: 1:50
GROUND FLOOR PLAN
1
150 MM
THICK
BELT
BEAM
150 MM THICK
BELT BEAM
1020
[3'-5"]
600
[2']
1095
[3'-8"]
600
[2']
495
[1'-8"]
976
[3'-3"]
495
[1'-8"]
600
[2']
1248
[4'-2"]
1200
[4']
798
[2'-8"]
413
[1'-5"]
1200
[4']
413
[1'-5"]
150
[6"]
12428
[41'-5"]
9
7
6
[
3
'-
3
"
]
1
7
6
3
[
5
'-
1
1
"
]
9
7
6
[
3
'-
3
"
]
1
7
6
3
[
5
'-
1
1
"
]
2565
[8'-7"]
150
[6"]
3166
[10'-7"]
150
[6"]
2946
[9'-10"]
150
[6"]
1875
[6'-3"]
150
[6"]
2
9
8
0
[
9
'-
1
1
"
]
1
5
0
[
6
"
]
2
7
7
0
[
9
'-
3
"
]
1
5
0
[
6
"
]
3
6
3
1
[
1
2
'-
1
"
]
1
2
1
9
[
4
'-
1
"
]
6
0
0
[
2
']
1
7
3
2
[
5
'-
9
"
]
9
7
5
[
3
'-
3
"
]
1
5
6
3
[
5
'-
3
"
]
1
8
9
9
[
6
'-
4
"
]
2
0
5
1
[
6
'-
1
0
"
]
1
2
0
0
[
4
']
6
2
9
[
2
'-
1
"
]
4
2
4
[
1
'-
5
"
]
9
7
5
[
3
'-
3
"
]
1
5
0
[
6
"
]
1
6
3
7
8
[
5
4
'-
7
"
]
1150
[3'-10"]
2
7
3
9
[
9
'-
2
"
]
1
5
0
[
6
"
]
2
0
0
0
[
6
'-
8
"
]
1
5
0
[
6
"
]
3
7
0
0
[
1
2
'-
4
"
]
1
5
0
[
6
"
]
2
7
1
0
[
9
']
7
5
0
[
2
'-
6
"
]
7
5
0
[
2
'-
6
"
]
2102
[7']
4500
[15']
4200
[14']
150
[6"]
2500
[8'-4"]
150
[6"]
2500
[8'-4"]
976
[3'-3"]
9
7
6
[
3
'-
3
"
]
2
9
5
9
[
9
'-
1
0
"
]
976
[3'-3"]
150
[6"]
1126
[3'-9"]
150
[6"]
1
9
1
5
[
6
'-
5
"
]
1276
[4'-3"]
6
0
0
[
2
']
6
0
0
[
2
']
2
7
2
4
[
9
'-
1
"
]
9
7
6
[
3
'-
3
"
]
1
5
0
[
6
"
]
9
0
0
[
3
']
2
1
7
5
[
7
'-
3
"
]
6
0
0
[
2
']
6
0
0 [
2
']
8
0
7
[
2
'-
8
"
]
8
0
7
[
2
'-
8
"
]
4
2
4
[
1
'-
5
"
]
1
0
7
3
[
3
'-
7
"
]
5
6
0
[
1
'-
1
0
"
]
1
8
9
9
[
6
'-
4
"
]
1
0
3
8
[
3
'-
6
"
]
1
8
9
9
[
6
'-
4
"
]
2
2
6
7
[
7
'-
7
"
]
1
2
0
0
[
4
']
2
0
6
2
[
6
'-
1
0
"
]
1
8
9
9
[
6
'-
4
"
]
1
8
6
3
[
6
'-
3
"
]
1
2
0
0
[
4
']
9
1
9
[
3
'-
1
"
] 1
5
0
[
6
"
]
1
8
3
0
8
[
6
1
']
4
5
0
[
1
'-
6
"
]
5
1
0
[
1
'-
8
"
]
4
5
0
[
1
'-
6
"
]
2
7
3
9
[
9
'-
2
"
]
1
5
0
[
6
"
]
3
7
8
5
[
1
2
'-
7
"
]
1
5
0
[
6
"
]
9
6
8
2
[
3
2
'-
3
"
]
1
5
0
[
6
"
]
1
3
5
1
[
4
'-
6
"
]
1
5
0
[
6
"
]
450
[1'-6"]
1828
[6'-1"]
450
[1'-6"]
700
[2'-4"]
450
[1'-6"]
1654
[5'-6"]
1052
[3'-6"]
944
[3'-2"]
1899
[6'-4"]
1094
[3'-8"]
750
[2'-6"]
1600
[5'-4"]
2
7
3
9
[
9
'-
2
"
]
750
[2'-6"]
1850
[6'-2"]
600
[2']
9
7
6
[
3
'-
3
"
]
707
[2'-4"]
450
[1'-6"]
150
[6"]
12428
[41'-5"]
4735
[15'-9"]
150
[6"]
6494
[21'-8"]
150
[6"]
750
[2'-6"]
R
2
8
6
1
[
R
9
'-
6
"
]
1
2
1
0
[
4
']
2367
[7'-11"]
ARC LENGTH
6154 [20'-6"]
MASTER SUITE
BEDROOM
# 1
WALK-IN
CL
KITCHEN
LIVING
&
DINING
ENTERTAINMENT
ROOM
BEDROOM
# 2
BEDROOM
# 3
BATH
ROOM
# 2
HALL
WASH
ROOM
BACK
PATIO
MASTER
BATH
ROOM
# 1
FRONT
PATIO
D2
D2
D2
W3
W4
W4
W3
D1 D1
W4
D1
W3
W2
W1
W1
D3
D4
D3
D5
D5
W3
W4
W3
W6 W3 W6 W6
W5
W6
D2
D2
D6
D2
D2 D2
D5
D5
1-1
SEC
1-1
SEC
2-2
SEC
2-2
SEC
150 MM
THICK
BELT
BEAM
150 MM
THICK
BELT
BEAM
W4
4
2
8
[
1
'-
5
"
]
Scale: 1:50
PROPOSED ROOF FRAMING SLAB PLAN
1
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r
.
.
.

.

@
3
0
0
c
r
s
.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r. .. .
@ 300 crs.
r
.
.
.

.

@
3
0
0
c
r
s
.
r
.
.
.

.

@
3
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
r .. .
@ 200 crs.
r

.
.

.

@
2
0
0
c
r
s
.
ARC LENGTH
6154 [20'-6"]
6955
[23'-2"]
A-A
SEC
A-A
SEC
B-B
SEC
B-B
SEC
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
2/8
SHEET NAME
GROUND FLOOR PLAN & PROPOSED
ROOF FRAMING SLAB PLAN
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
AREA OF PROPOSED FLOOR
190.92 m [2055.06 Ft]
Scale: 1:50
FRONT ELEVATION
1
2
4
0
0
[
8
']
L
G
150 MM THINK
PROPOSED SLAB
D1 D1
W1
8
6
8
[
2
'-
1
1
"
]
3
0
0
[
1
']
2
2
8
2
[
7
'-
7
"
]
1
5
0
[
6
"
]
2
4
5
0
[
8
'-
2
"
]
7
0
0
[
2
'-
4
"
] 1
5
0
[
6
"
]
1
5
0
[
6
"
]
FL FL
W4
W3
R
3
6
6
[R
1'-3
"]
Scale: 1:50
REAR ELEVATION
2
L
G
150 MM THINK
PROPOSED SLAB
W6 W6 W6 W3 W3
D2
FL
D2
R
366
[R
1'-3"]
3
3
0
0
[
1
1
']
2
4
5
0
[
8
'-
2
"
]
7
0
0
[
2
'-
4
"
] 1
5
0
[
6
"
]
1
5
0
[
6
"
]
1
2
0
0
[
4
']
1
2
0
0
[
4
']
3
6
6
[
1
'-
3
"
]
Scale: 1:50
LEFT SIDE ELEVATION
3
3
0
0
[
1
']
3
1
5
0
[
1
0
'-
6
"
]
1
5
0
[
6
"
]
1
2
0
0
[
4
']
1
2
0
0
[
4
']
7
5
0
[
2
'-
6
"
]
1
2
0
0
[
4
']
1
2
0
0
[
4
']
3
6
6
[
1
'-
3
"
]
L
G
150 MM THINK
PROPOSED SLAB
W4 W4 W3 W4 W3
FL
R
3
6
6
[R
1'-3
"]
1
5
0
[
6
"
]
7
0
0
[
2
'-
4
"
]
3
0
0
[
1
']
2
4
5
0
[
8
'-
2
"
]
Scale: 1:50
SECTION AT 1-1
1
L
G
OUTLINE OF
WALL
FOOTING
Hardcore Spread, Level &
Compact in 150mm layers
150 MM THINK
PROPOSED SLAB
MASTER SUITE
BEDROOM
# 1
BEDROOM # 3
BATH
ROOM # 2
WASH
ROOM
3
0
0
[
1
']
3
1
5
0
[
1
0
'-
6
"
]
1
5
0
[
6
"
]
2
4
0
0
[
8
']
7
5
0
[
2
'-
6
"
]
CL
3
0
0
[
1
']
FL FL FL
D2
W4 W6
Scale: 1:50
RIGHT SIDE ELEVATION
4
L
G
150 MM THINK
PROPOSED SLAB
W1 W1 W1
W3 W4
W5
W6
1
2
0
0
[
4
']
1
2
0
0
[
4
']
7
5
0
[
2
'-
6
"
]
FL
R
3
6
6
[R
1'-3
"]
1
5
0
[
6
"
]
7
0
0
[
2
'-
4
"
]
2
4
5
0
[
8
'-
2
"
]
3
0
0
[
1
']
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
3/8
SHEET NAME
FRONT, REAR, LEFT & RIGHT SIDE
ELEVATION, SECTION AT 1-1
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
Scale: 1:10
MANHOLE PLAN
1
150
[6"]
570
[1'-11"]
150
[6"]
900
[3']
1
5
0
[
6
"
]
5
7
0
[
1
'-
1
1
"
]
1
5
0
[
6
"
]
9
0
0
[
3
']
cast iron
duty basin
cover & frame
15
[1"]
15
[1"]
1
5
[
1
"
]
1
5
[
1
"
]
1
5
0
[
6
"
]
1
1
8
[
5
"
]
GL
150
[6"]
150
[6"]
900
[3']
150 mm thick
reinf'd conc.
block wall.
150 mm thick
conc. slab reinf'd
.. ; r .. .
200 mm high
bencing to bottom
of manhole
13 mm thick conc.
and sand
rendering
steel float finish
150 mm thick
conc. base all in
1:2:4 conc. mix.
cast iron
duty manhole
cover & frame
Scale: 1:10
TYPICAL SECTION THRU MANHOLE
1
600
[2']
8
9
9
[
3
']
Scale: 1:10
STIFFENER TYPE 'I'
1
1
5
0
[
6
"
]
300
[1']
10mm msb
@ 300 crs.
150mm
Blockwall
4 # 12mm msb
in 1:2:4 conc. mix
Scale: 1:10
STIFFENER TYPE 'L'
2
150
[6"]
1
5
0
[
6
"
]
1
5
0
[
6
"
]
150
[6"]
300
[1']
3
0
0
[
1
']
10mm
msb @ 300
crs.
7 # 12mm
msb in 1:2:4
conc. mix
150mm
Blockwall
Scale: 1:10
STIFFENER TYPE 'T'
3
150
[6"]
150
[6"]
150
[6"]
450
[1'-6"]
1
5
0
[
6
"
]
10mm
msb @ 300
crs.
150mm
Blockwall
10 # 12mm
msb in 1:2:4
conc. mix
Scale: 1:50
FOUNDATION PLAN
1
See
Stiffener
Type L
See
Stiffener
Type T
2866
[9'-7"]
450
[1'-6"]
2646
[8'-10"]
450
[1'-6"]
1575
[5'-3"]
450
[1'-6"]
826
[2'-9"]
450
[1'-6"]
12728
[42'-5"]
450
[1'-6"]
2115
[7'-1"]
450
[1'-6"]
See
Stiffener
Type I
4
5
0
[
1
'-
6
"
]
2
8
8
9
[
9
'-
8
"
]
4
5
0
[
1
'-
6
"
]
1
7
0
0
[
5
'-
8
"
]
4
5
0
[
1
'-
6
"
]
3
4
0
0
[
1
1
'-
4
"
]
4
5
0
[
1
'-
6
"
]
6
8
8
9
[
2
3
']
4
5
0
[
1
'-
6
"
]
1
4
8
0
[
4
'-
1
1
"
]
4
5
0
[
1
'-
6
"
]
3
1
6
[
1
'-
1
"
]
4435
[14'-9"]
450
[1'-6"]
2750
[9'-2"]
450
[1'-6"]
2994
[10']
450
[1'-6"]
750
[2'-6"]
3900
[13']
450
[1'-6"]
1802
[6']
450
[1'-6"]
3950
[13'-2"]
450
[1'-6"]
5
5
5
0
[
1
8
'-
6
"
]
4
5
0
[
1
'-
6
"
]
9
3
8
2
[
3
1
'-
3
"
]
4
5
0
[
1
'-
6
"
]
1
0
5
1
[
3
'-
6
"
]
4
5
0
[
1
'-
6
"
]
3
4
8
5
[
1
1
'-
7
"
]
4
5
0
[
1
'-
6
"
]
2
4
3
9
[
8
'-
2
"
]
4
5
0
[
1
'-
6
"
]
1
8
6
0
8
[
6
2
']
2
7
3
9
[
9
'-
2
"
]
4
1
5
0
[
1
3
'-
1
0
"
]
2800
[9'-4"]
1
8
6
0
8
[
6
2
']
450
[1'-6"]
4435
[14'-9"]
450
[1'-6"]
6194
[20'-8"]
450
[1'-6"]
11978
[39'-11"]
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
4/8
SHEET NAME
STIFFENER TYPE 'I','L' & 'T', TYPICAL
SECTION THRU MANHOLE & PLAN,
FOUNDATION PLAN
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
Scale: 1:50
GROUND FLOOR ELECTRICAL & PLUMBING LAYOUT
1
MASTER SUITE
BEDROOM
# 1
WALK-IN
CL
KITCHEN
LIVING
&
DINING
ENTERTAINMENT
ROOM
BEDROOM
# 2
BEDROOM
# 3
BATH
ROOM
# 2
HALL
WASH
ROOM
BACK
PATIO
MASTER
BATH
ROOM
# 1
ABSORPTION
PIT
M.H
M.H
M.H
M.H
M.H
G.T
T.G.B
T.G.B
M.H
(3") 75 dia.
pvc pipe
(4") 100 dia. pvc pipe
(
4
"
)

1
0
0

d
i
a
.

p
v
c

p
i
p
e
(
4
"
)

1
0
0

d
i
a
.

p
v
c

p
i
p
e
(
4
"
)

1
0
0

d
i
a
.

p
v
c

p
i
p
e
(3") 75 dia.
pvc pipe
(3") 75 dia.
pvc pipe
G.T
(3") 75 dia.
pvc pipe
SEPTIC
TANK
M.H
(4") 100 dia. pvc pipe
(
4
"
)

1
0
0

d
i
a
.

p
v
c

p
i
p
e
3
5
8
0
[
1
1
'-
1
1
"
]
3
0
1
6
[
1
0
'-
1
"
]
3
0
0
0
[
1
0
']
1
6
5
0
[
5
'-
6
"
]
3300
[11']
(4") 100 dia.
pvc pipe
FRONT
PATIO
150 MM
THICK
BELT
BEAM
150 MM
THICK
BELT
BEAM
3 $
3 $
$
$
$
2 $
2 $
$
3 $
3 $
2 $
WINDOW & DOOR SCHEDULE
SYM DIMENSION DESCRIPTION QTY
W1 324.3 x 1100 SLIDING 2
W2 875 x 1100 SLIDING 1
W3 1100 X 1100 FRENCH 5
W4 1179 X 1100 FRENCH 5
W5 875 X 875 LOUVRE 1
W6 500 X 1100 LOUVRE 4
TOTAL 18
D1 976 X 2350 FANCY 3
D2 900 X 2350 PANEL 7
D3 1951 X 2350 BI-FOLDING 2
D4 1850 X 2350 BI-FOLDING 1
D5 1162 X 2350 BI-FOLDING 4
D6 824 X 2350 FLUSH PANEL 1
TOTAL 18
50 X 100 DOOR FRAME 36
ELECTRICAL SCHEDULE
AMOUNT SYMBOLS DESCRIPTION REMARKS
$
M
ONE WAY SWITCH
TWO WAY SWITCH
220 VOLT OUTLET
SECURITY LIGHTS
110 VOLT OUTLET
INCANDESCENT LIGHT FIXTURE
CHANDELIER LIGHT FIXTURE
FLUORESCENT TUBE
PANEL BOX
J.P.S METER
CEILING HANG TUNGSTEN
LIV. & DIN, BTH, BD RM
BK PATIO, WASH, ENTERTAIN.
WASH RM, KIT & HALL
OUTSIDE CORNERS
ALL ROOMS
BD RM, MAS & BATH RM
MAS. BED, LIV. & DIN. ROOM
FRONT PATIO
LIV. & DIN. ROOM
PLACED ON BOUNDARY CLN
BED, WASH RM, HALL, BK PAT.
1
2
3
4
3
6
27
7
1
1
8
THREE WAY SWITCH 4 WASH RM& WALK-IN CL, ETC. 3 $
2 $
KEY FOR DRAINAGE
(3") 75 dia. pvc pipe
(4") 100 dia. pvc pipe
M.H
Proposed
manhole
T.G.B
Trap Gully
Basin
G.T
Grease
Trap
450
[1'-6"]
1
2
0
0
[
4
']
3
0
0
[
1
']
150
[6"]
150
[6"]
1
5
0
[
6
"
]
1
8
7
[
7
"
]
-r... .. r.. ...,
@250 crs. in (1:2:4 conc Mix.)
r... .. ... - .
150mm Blockwall.
300 X 300 Ceramic Floor Tiles
Laid on 25mm thick 1:3 Mix screed
150mm thick
1:2:4 Mix Conc Floor Slab
Hardcore Spread, Level &
Compact in 150mm layers
Scale: 1:20
TYP FTG DETAIL 'A-A'
1
7
5
[
3
"
]
L
G
2
4
5
0
[
8
'-
2
"
]
Scale: 1:20
TYPICAL ROMAN COLUMN
1
450
[1'-6"]
Scale: 1:20
SECTION THRU ROMAN COLUMN
1
4
0
0
[
1
'-
4
"
]
3
0
0
[
1
']
(
3
8
") 10 dia. @ (1') 300 crs.
6# (
1
2
") 12 dia bars
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
5/8
SHEET NAME
SITE & DRAINAGE PLAN, MANHOLE
PLAN & SECTION GREASE TRAP &
GULLY BASIN PLAN & SECTION, SITE
LOCATION
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
Scale: 1:50
SECTION AT 2-2
1
KITCHEN
BEDROOM
# 3
HALL
See Beam
Detail
See Footing
Detail A-A
150 MM THINK
PROPOSED SLAB
L
G
OUTLINE OF
WALL
FOOTING
Hardcore Spread, Level &
Compact in 150mm layers
See Lintel
Detail
3
0
0
[
1
']
3
1
5
0
[
1
0
'-
6
"
]
1
5
0
[
6
"
]
3
0
0
[
1
']
FL FL
D2 D2
Scale: 1:20
TYPICAL SECTION THRU ROOF SLAB (SEC A-A)
1
25 mm
covering
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
300
[1']
300
[1']
722
[2'-5"]
350
[1'-2"]
538
[1'-10"]
722
[2'-5"]
1125
[3'-9"]
538
[1'-10"]
685
[2'-3"]
1125
[3'-9"]
1150
[3'-10"]
685
[2'-3"]
350
[1'-2"]
1150
[3'-10"]
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
12mm bars @
300 mm bothways
3
0
0
[
1
']
1
5
0
[
6
"
]
Scale: 1:20
TYPICAL SECTION THRU ROOF SLAB (SEC B-B)
2
1221
[4'-1"]
350
[1'-2"]
748
[2'-6"]
1221
[4'-1"]
1100
[3'-8"]
748
[2'-6"]
350
[1'-2"]
1100
[3'-8"]
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
12mm bars @
300 mm bothways
12mm bars @
300 mm bothways
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
4 # 12mm
msb in 1:2:4
conc. mix
10 mm bar
@ 300 crs.
25 mm
covering
300
[1']
300
[1']
1
5
0
[
6
"
]
3
0
0
[
1
']
Not Drawn to Scale
EARTHING DETAIL
1
GL
TO OF CONDUIT NOT
TO BE SEALED
20 mm DIA. 1200 (5" x 4')
LONG COPPER CLAD GROUND ROD
100 mm DIA. PVC CONDUIT
25 mm DIA BARE COPPER TO
GROUND LUG IN LOAD CENTER
FINE EARTH FILL
APPROX. 250 mm DEEP
4
5
8
[
1
'
-
6
"
]
Not Drawn to Scale
SINGLE LINE DIAGRAM
1
M
25 mm DIA. BARE COPPER
WIRE TO GROUND ROD
50 mm DIAMETER POTHEAD
FROMJ.P.S. Co. POWER LINE
50 mm DIAMETER POTHEAD
3- SINGLE CORE 25 mm PVC INSULATED WIRES IN 63 mm
DIA. CONDUIT (AIRAL) FROMSERVICE POLE TO MAIN
BREAKER IN PANEL
MAIN PANEL (D.P. 1)
50 mm DIA. BARE COPPER
WIRE TO GROUND ROD 100
A
KILOWATT-HOUR METER
LOCATED ON SERVICE
ENTRY POLE
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
6/8
SHEET NAME
SECTION AT 2-2, TYPICAL SECTION
THRU ROOF SLAB (SEC B-B),
TYPICAL SECTION THRU ROOF SLAB
(SEC A-A), EARTHING DETAIL &
SINGLE LINE DIAGRAM
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
WATER LEVEL
12"(300) x 12"(300) R.C. CONC. TIE BEAM
REINFORCED WITH
- ~. r.r.` :~ ~~.
r-r` ~- r.` ^.
TO BE PLACED AT EVERY 5'-0"(1500)
ALONG DEPTH OF PIT.
BARS @ CRS. CENTRE SIZE
2400
[8'-0"]
3
0
0
0
533
[1'-9"]
1950 533
[1'-9"]
P1
SEC
P1
SEC
12 mm dia.
@ 300 c/c
1
2

m
m

d
i
a
.
@

3
0
0

c
/
c
12 mm dia.
@ 300 c/c top
[6'-6"]
[
1
0
'
-
0
"
]
3000
[10'-0"]
TABLE OF SEPTIC TANK SIZES
A
8'-0" [2440mm]
6'-0" [1830mm]
7'-0" [2130mm]
5'-0" [1525mm]
3785
2725
1705
(LITRES)
1230
(GALLONS)
15 - 20 1000
10 - 14
5 - 9
1 - 4
720
450
325
PERSONS
No. OF
CAPACITY
C
4-0" [1220mm]
3'-6" [1065mm]
3'-6" [1065mm]
3'-6" [1065mm]
WIDTH
B
4-0" [1220mm]
3'-6" [1065mm]
3'-6" [1065mm]
3'-0" [915mm]
LENGTH
D E
3'-0" [915mm] 4-0" [1220mm]
3'-0" [915mm]
3'-0" [915mm]
3'-0" [915mm] 4-0" [1220mm]
4-0" [1220mm]
3'-6" [1065mm]
DEPTH
1
SEC
1
SEC
ROOF SLAB
1
0

m
m


S
t
i
r
r
u
p
s

@

2
5
0

m
m

c
r
s
.
D
E
P
T
H
V
A
R
IE
S
GL
Scale: 1:20
TYPICAL SECTION THRU STIFFENER COLUMN
1
Scale: 1:20
SECTION AT 1-1
2
300
[1']
1
5
0
[
6
"
]
4 # 12 mm
bars
10 mm
Stirrups @ 250
mm crs.
3
0
0
[
1
']
1
5
0
[
6
"
]
3
1
5
0
[
1
0
'-
6
"
]
2
2
5
[
9
"
]
1
5
0
[
6
"
]
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
7/8
SHEET NAME
DETAIL OF ABSORPTION PIT (SEC
P1) & PLAN, TABLE OF SEPTIC TANK
SIZES, TYPICAL SECTION THRU
STIFFENER COLUMN
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.
, :~
@ 12" O/C.
r, ~~ :~
@12" O/C.
, :~
@ 12" O/C.
r, ~~ :~
@12" O/C.
Scale: 1:30
SECTION 2-2
1
SEWAGE LINE
SLOPE 1:12
Scale: 1:30
SECTION 1-1
1
ALL DIMENSION ARE REPRESENTEDIN
MILLIMETERS
CLIENT NAME &ADDRESS
SHEET
NO.
DESIGNEDBY:
DRAWN BY:
DATE:
SCALE: AS SHOWN
GENERAL NOTES
MR. &MRS. VERON &DONYA DACRES
LOT #1046 CLAYTONVILLE DRIVE,
WILLOWDENE,
ST. CATHERINE, J AMAICA
DERVIN GREY
DERVIN GREY
AUGUST 26, 2013
8/8
SHEET NAME
SEPTIC TANK PLAN, SECTION 1-1 &
2-2
CONTRACTOR SHALL BE
RESPONSIBLE FOR ACCURATELY
SETTING OUT OF THE WORKS AND
MAINTAINING REQUESTED LEVELS.
ANY DISCREPANCIES IN
DIMENSIONS OUT AND OTHER
DETAILS MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE PROCEEDING WITH THE
CONSTRUCTION.
THIS DRAWING MUST BE READ IN
CONJUNCTION WITH & AS A PART OF
THE COMPLETE SET OF DRAWINGS,
INCLUSIVE OF ALL ENGINEERING
DRAWINGS.
CONCRETE 1:3:6 CUBE WITH
CRUSHING STRENGTH OF 20MPa
(3000psi) @ 28 DAYS, REINFORCING
STEEL - BAR SIZE 12mm GRADE 250
(MILD STEEL)
DO NOT SCALE DRAWINGS
ALL INTERNAL WALLS IN EXISTING
BUILDING ARE DRY WALL
PARTITIONS.

You might also like