Infeed Module LED Significance
Infeed Module LED Significance
01
NC contact NO contact
74 nc 73.2 73.1 nc 72 5.3 5.2 5.1 63 9 9 64 19 7 45 44 10 15 15 R 9 112 48 111 213 113 NS1 NS2 AS1 AS2
X111
Relay contact for group signal I2t and motor overtemperature Pulse enable Enable voltage Enable voltage Drive enable Reference potential for enable voltage P24 P15 N15 N24 M M RESET (R+term.15) Enable voltage Setup operation Contactor energization, start Signaling contact, line contactor Enable signal for internal line contactor Signaling contact, start inhibit (NC contact)
X121
X141
DC link power supply for buffering power failures External infeed for the electronics power supply External infeed for the electronics power supply External infeed for the electronics power supply
M500
P500 2U1 1U1 2V1 1V1 2W1 1W1
X181 1)
Equipment bus
M600
Device is not ready, green no enable signal (term. 63, 64 or 48) red Line supply fault
1) Jumpers inserted when the equipment is supplied 2) For UI modules, there is no X172 U1 V1 W1 X131 PE
Fig. 6-2
Interfaces, infeed module (UI module) or infeed/regenerative feedback module (16 to 55 kW I/R module)
Siemens AG 2008 All Rights Reserved SIMODRIVE 611 Configuration Manual (PJU) 05/2008 Edition
6-151