0% found this document useful (0 votes)
151 views

Recurring Formulas: For Application Engineers

This document provides formulas for calculating electrical values such as kilowatts, amps, horsepower, and kVA for alternating current, direct current, and electric motors. It includes formulas for calculating values from volts, amps, power factor, and efficiency. Formulas are provided for both balanced and unbalanced three-phase and four-phase AC circuits.

Uploaded by

Alex Carmo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views

Recurring Formulas: For Application Engineers

This document provides formulas for calculating electrical values such as kilowatts, amps, horsepower, and kVA for alternating current, direct current, and electric motors. It includes formulas for calculating values from volts, amps, power factor, and efficiency. Formulas are provided for both balanced and unbalanced three-phase and four-phase AC circuits.

Uploaded by

Alex Carmo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Recurring Formulas

For Application Engineers


DESIRED DATA Kilowats ALTERNATING CURRENT THREE-PHASE 1.73 x volts x amps x P.F. 1000 1.73 x volts x amps 1000 1.73 x volts x amps 1000 DIRECT CURRENT Volts x amps 1000

kVA Reactive kVA Horse Power (Output) Amperes (When hp is known) Amperes (When kW is known) Amperes (When kVA is known)

1 P.F.

)
Volts x amps x Eff. 746 x 100 Hp x 746 x 100 Volts x Efficiency Kilowats x 1000 Volts

1.73 x volts x amps x Eff. x P.F. 746 x 100 Hp x 746 x 100 1.73 x volts x P.F. Kilowatts x 1000 1.73 x volts x P.F. kVA x 1000 1.73 x volts

Kilowatts kVa Killowatts x 1000 Power Factor (for 3-phase) = 1.73 x Volts x Amps HP x 0.746 x 100 Motor Kilowatts = Efficiency HP x 0.746 x 100 Motor kVa = Efficiency x Power Factor Power Factor =

Kilowatts Power Factor 5250 x Full-Load HP Motor Full-Load Torque = Speed in RPM 120 x Frequency Syncronous Speed in RPM = Number of Poles Motor kVa =

kVa of Three Phase A-C Circuits:


Three-wire (Balanced) kVa = Volts across any two wires x amperes in any wire x 1.732/1000 Three-wire (Unbalanced): kVa = Volts across any two wires x average of the amperes in the three wires x 1.732/1000 Four-wire (Balanced): kVa = Volts across any outside wire to neutral wire x amperes in any outside wire x 3/1000 Four-wire (Unbalanced): kVa = Volts across any outside wire to neutral wire x average of the amperes in three outside wires x 3/1000