0% found this document useful (0 votes)
103 views2 pages

Design of Plan Bracing

The document summarizes the design of plan bracing connections for Node No. 1557. It analyzes two connection types - a bolted connection and welded connection. For the bolted connection, calculations show the tensile and shear stresses on two 24mm bolts meet capacity. For the welded connection, the required weld length of 275mm is less than the provided length of 420mm. Both connection types meet design requirements.

Uploaded by

dsananda
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views2 pages

Design of Plan Bracing

The document summarizes the design of plan bracing connections for Node No. 1557. It analyzes two connection types - a bolted connection and welded connection. For the bolted connection, calculations show the tensile and shear stresses on two 24mm bolts meet capacity. For the welded connection, the required weld length of 275mm is less than the provided length of 420mm. Both connection types meet design requirements.

Uploaded by

dsananda
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Design of Plan Bracing Connections

Node No. = 1557 L/C = Member No = ( Maximum ) 109 3182

Plan Bracing Axial Force, P = 113.092 kN Memb = Load Data Fy = 250 N/mm2 Sectional Area A =13.8 cm2 L90x90x8

Axial Capacity, T 155.25 = kN > 113.092 KN, OK Design for 75 % Axial capacity = 116.4375 kN A) Connection Type-1 ( Bolted Conn.) Alternative Grade of Bolts = 8.8 Dia of Bolts, db = 24 mm Total Nos of bolts (n)= 2 Tensile Stress, Ft =286 N/mm2 Shear Stress, Fv = 191 N/mm2 Shear Check V= Max ( P or 75 % T ) / n

( Tc = 0.45 x Fy x A )

Root Area of 366.5829 Bolt = mm2 Capacity of Bolt Tension, Tc = 104.8427 kN Shear, Vc = 70.01733 kN

Shear per bolt, 58.21875 V= kN < Shear Capacity, OK Weld length Calculations Weld Thkness, tw = 6 mm Length Reqd, P/ lw ( sw = x 0.707 x t ) lw Req.= 275 mm Weld Prov. 2 =x(90+25+50+50) Weld Prov. = 420 mm A) Profile Welded Connection Weld length Calculations sw = 100 N/mm2

Weld Provide is OK

Weld Thkness, tw = 6 mm Length Reqd, P/ lw ( sw = x 0.707 x t ) lw Req.= 275 mm Lw = 2x(90+74) Weld Prov.Lw = 328 mm

sw =

100 N/mm2

Weld Provide is OK