Minimum Thermal Flow
Minimum Thermal Flow
vol.3_iss 1
Minimum continuous flow is the lowest flow rate at which a centrifugal pump may be operated on a continuous basis without exceeding the design constraints of the manufacturer or the equipment specifier. Thermal stability, mechanical integrity and process control are the three primary factors that contribute to the determination of allowable continuous minimum flow. A minimum continuous flow should be independently determined for each factor. The highest minimum flow rate resulting from this analysis dictates the minimum flow rate for a pump. This issue will focus on minimum continuous thermal flow, which is defined as: The lowest flow at which the pump may operate without its operation being impaired by the temperature rise of the pumped fluid.1
Page 1 of 4
at shut-off (zero flow), the temperature and pressure will increase until either the heat losses from the casing balance the heat input, or the pressure is relieved. If the pump is completely blocked in, either by a closed discharge valve or reverse flow check-valve, pressure may rise until it exceeds the material design limits of the pump and a catastrophic failure of the casing or mechanical seal may occur. The rate at which heat will rise in a blocked in casing can be calculated by the following equation.
For Example: A pump drawing 25 kW (33.5 hp) at shut-off, with a 20 liter (5.3 gallon) casing volume, handling water4 would increase in temperature at a rate of 0.3 oC/sec (.5 o F/sec). The time for the liquid to start vaporizing may be calculated by dividing the temperature rate into the difference between the pump inlet fluid temperature and its saturation temperature. Calculating Minimum Continuous Thermal Flow First determine the difference between the pump inlet fluid temperature and its saturation temperature. In The Pump Handbook, Igor Karassik5 recommends subtracting 9oC (15oF) from this value to arrive at the maximum allowable temperature rise. Starting at 10% of the best efficiency point flow (BEP)6, iterate through increasing flow rates, using the following calculation, until the temperature rise through the pump no longer exceeds the maximum allowable temperature rise. If the temperature rise at 10% of BEP flow is less than the maximum allowable temperature rise, then use 10% of BEP as the minimum continuous thermal flow. Specific heat of water = 4.19 kJoules/kg oK or 1.0 Btu/lb oF McGraw-Hill 1976 6 Refer to the pump curve supplied by the manufacturer to obtain the flow and power data, making sure it is corrected for product density and viscosity.
5 4
2006 Lawrence Pumps Inc. 371 Market St., Lawrence. MA. 01843. Tel :(978) 682-5248 Fax:(978) 975-4291 Web http://www.lawrencepumps.com Contact: [email protected]
Page 2 of 4
Example: Determine the minimum thermal flow for a 100 l/s (1540 gpm), 500 kW (670 hp) multistage pump that at 10% of rated flow draws 375kW (500hp). The inlet temperature of the water is 70oC (158oF), the inlet pressure is atmospheric pressure 1000 kPa (14.5 psia). The liquid volume of the pump casing is 20 liters (5.3 gallons). Ten Percent of the rated flow is 10 l/s (154 gpm). The saturation temperature for water at atmospheric pressure is 100oC (212oF). Therefore, the allowable temperature rise is 30oC (54oF) minus a 9oC (15oF) factor of safety, for total allowable temperature rise of 21oC (39oF).
2006 Lawrence Pumps Inc. 371 Market St., Lawrence. MA. 01843. Tel :(978) 682-5248 Fax:(978) 975-4291 Web http://www.lawrencepumps.com Contact: [email protected]
Page 3 of 4
For this case the 10% flow would satisfy the minimum thermal flow requirements. However, at 500 KW (670BHP), operation of the pump would likely be limited to a much higher flow because of mechanical stability requirements. The lowest flow that a pump can operate at without compromising mechanical reliability is the Minimum Stable Flow. For most pumps, this is more of a limiting factor than minimum thermal flow. Still, minimum thermal flow often does become a critical factor, especially when dealing with volatile liquids , and it should always be checked when evaluating a pump system. In our next issue well discuss the factors that determine Minimum Stable Flow and the reliability impact of non-compliance.
2006 Lawrence Pumps Inc. 371 Market St., Lawrence. MA. 01843. Tel :(978) 682-5248 Fax:(978) 975-4291 Web http://www.lawrencepumps.com Contact: [email protected]