Hind Rectifiers LTD.: Semiconductor Division
Hind Rectifiers LTD.: Semiconductor Division
SEMICONDUCTOR DIVISION
FORMAT DOCUMENT
TITLE:- NON-CONFIRMITY / CORRECTIVE / PREVENTIVE ACTION DEPARTMENT: - Semiconductor Traction:
Problem Description: - Wire crimped at timer T1 & contactor QCON Found improper
and loosely connected.
Investigation Details:Wiring, crimping & connection of timer & contactor was done in factory. Problem present due to improper crimping and loose connection. This is in-house failure.
WHO
WHEN
Complaint attended by service person for Loco No: 28503 : BONDAMUNDA SIV Sr No: 2012E/342/04
Service
Completed
Preventive Action:Following Preventive actions are implemented: Based on this failure case, Action to be taken to ensure the healthyness of crimping and tightening of control wire harness of timer & contactor. Production engineer instructed for proper crimping & connection.
Verified By: -
Date:- 02/07/2013
Preventive Action:-
Improper crimping
Not properly getting inserted into contact position due to lug body side portion gets touch to timer body portion. Need to change way of LUG connecting .
Action taken :
Properly crimp
Connect the Lug with flat portion of it as shown in picture. so it will properly get inserted and cannot be out from connection.
Preventive Action:Crimping tool (HT-9160) will have to change every after 10 months use as our use is more and life of tool is also get deteriorate.