Hind Rectifiers LTD.: Semiconductor Division

An improper crimped wire connection was found at a timer and contactor. This was determined to be an in-house failure due to improper crimping. Corrective actions included attending to the complaint by servicing the locomotive. Preventative actions included instructing production engineers to ensure proper crimping and tightening of control wire harnesses and changing crimping tools every 10 months due to high use.

Uploaded by

SURJIT SINGH
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views3 pages

Hind Rectifiers LTD.: Semiconductor Division

An improper crimped wire connection was found at a timer and contactor. This was determined to be an in-house failure due to improper crimping. Corrective actions included attending to the complaint by servicing the locomotive. Preventative actions included instructing production engineers to ensure proper crimping and tightening of control wire harnesses and changing crimping tools every 10 months due to high use.

Uploaded by

SURJIT SINGH
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

HIND RECTIFIERS LTD.

SEMICONDUCTOR DIVISION
FORMAT DOCUMENT
TITLE:- NON-CONFIRMITY / CORRECTIVE / PREVENTIVE ACTION DEPARTMENT: - Semiconductor Traction:

Reference No. SF-21-005

NC No. : RCA/01 Date: 02/07/2013

Problem Description: - Wire crimped at timer T1 & contactor QCON Found improper
and loosely connected.

Investigation Details:Wiring, crimping & connection of timer & contactor was done in factory. Problem present due to improper crimping and loose connection. This is in-house failure.

Corrective Action:Following corrective actions are implemented:

WHO

WHEN

Complaint attended by service person for Loco No: 28503 : BONDAMUNDA SIV Sr No: 2012E/342/04

Service

Completed

Preventive Action:Following Preventive actions are implemented: Based on this failure case, Action to be taken to ensure the healthyness of crimping and tightening of control wire harness of timer & contactor. Production engineer instructed for proper crimping & connection.

Verified By: -

Date:- 02/07/2013

HIND RECTIFIERS LTD.


SEMICONDUCTOR DIVISION
FORMAT DOCUMENT
TITLE:- NON-CONFIRMITY / CORRECTIVE / PREVENTIVE ACTION DEPARTMENT: - Semiconductor Traction:

Reference No. SF-21-005

NC No. : RCA/01 Date: 02/07/2013

Preventive Action:-

Improper crimping

Not properly getting inserted into contact position due to lug body side portion gets touch to timer body portion. Need to change way of LUG connecting .

Action taken :

Properly crimp

Connect the Lug with flat portion of it as shown in picture. so it will properly get inserted and cannot be out from connection.

HIND RECTIFIERS LTD.


SEMICONDUCTOR DIVISION
FORMAT DOCUMENT
TITLE:- NON-CONFIRMITY / CORRECTIVE / PREVENTIVE ACTION DEPARTMENT: - Semiconductor Traction:

Reference No. SF-21-005

NC No. : RCA/01 Date: 02/07/2013

Preventive Action:Crimping tool (HT-9160) will have to change every after 10 months use as our use is more and life of tool is also get deteriorate.