0% found this document useful (0 votes)
30 views

Table 7A: CQI Mapping Table For UE Categories 1 To 6

The document contains 5 tables (7A-7E) that map different CQI (Channel Quality Indicator) values to transport block size, modulation scheme, and reference signal power for various UE (User Equipment) categories in LTE networks. Each table specifies the parameters for a different category of UE, with higher categories corresponding to larger transport block sizes, more advanced modulation schemes like 16-QAM, and more reference signal power levels.

Uploaded by

adriansyahputra
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

Table 7A: CQI Mapping Table For UE Categories 1 To 6

The document contains 5 tables (7A-7E) that map different CQI (Channel Quality Indicator) values to transport block size, modulation scheme, and reference signal power for various UE (User Equipment) categories in LTE networks. Each table specifies the parameters for a different category of UE, with higher categories corresponding to larger transport block sizes, more advanced modulation schemes like 16-QAM, and more reference signal power levels.

Uploaded by

adriansyahputra
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

Document Title

Security Level:

Table 7A: CQI mapping table for UE categories 1 to 6.


CQI value

Transport

Number of Modulation Reference power

Block Size
N/A

HS-PDSCH

0
1

137

QPSK

173

QPSK

233

QPSK

317

QPSK

377

QPSK

461

QPSK

650

QPSK

792

QPSK

931

QPSK

10

1262

QPSK

11

1483

QPSK

12

1742

QPSK

13

2279

QPSK

14

2583

QPSK

15

3319

QPSK

16

3565

16-QAM

17

4189

16-QAM

18

4664

16-QAM

19

5287

16-QAM

20

5887

16-QAM

21

6554

16-QAM

22

7168

16-QAM

23

7168

16-QAM

-1

24

7168

16-QAM

-2

25

7168

16-QAM

-3

26

7168

16-QAM

-4

27

7168

16-QAM

-5

28

7168

16-QAM

-6

29

7168

16-QAM

-7

30

7168

16-QAM

-8

2014-01-06

NIR

XRV

9600

adjustment
Out of range

HUAWEI Confidential

Page1, Total5

Document Title

Security Level:

Table 7B: CQI mapping table for UE categories 7 and 8.


CQI value

Transport

Number of Modulation Reference power


HS-PDSCH

Block Size
N/A

137

QPSK

173

QPSK

233

QPSK

317

QPSK

377

QPSK

461

QPSK

650

QPSK

792

QPSK

931

QPSK

10

1262

QPSK

11

1483

QPSK

12

1742

QPSK

13

2279

QPSK

14

2583

QPSK

15

3319

QPSK

16

3565

16-QAM

17

4189

16-QAM

18

4664

16-QAM

19

5287

16-QAM

20

5887

16-QAM

21

6554

16-QAM

22

7168

16-QAM

23

9719

16-QAM

24

11418

16-QAM

25

14411

10

16-QAM

26

14411

10

16-QAM

-1

27

14411

10

16-QAM

-2

28

14411

10

16-QAM

-3

29

14411

10

16-QAM

-4

30

14411

10

16-QAM

-5

2014-01-06

NIR

XRV

19200

adjustment
Out of range

HUAWEI Confidential

Page2, Total5

Document Title

Security Level:

Table 7C: CQI mapping table for UE category 9.


CQI value

Transport

Number of Modulation Reference power


HS-PDSCH

Block Size
N/A

137

QPSK

173

QPSK

233

QPSK

317

QPSK

377

QPSK

461

QPSK

650

QPSK

792

QPSK

931

QPSK

10

1262

QPSK

11

1483

QPSK

12

1742

QPSK

13

2279

QPSK

14

2583

QPSK

15

3319

QPSK

16

3565

16-QAM

17

4189

16-QAM

18

4664

16-QAM

19

5287

16-QAM

20

5887

16-QAM

21

6554

16-QAM

22

7168

16-QAM

23

9719

16-QAM

24

11418

16-QAM

25

14411

10

16-QAM

26

17237

12

16-QAM

27

17237

12

16-QAM

-1

28

17237

12

16-QAM

-2

29

17237

12

16-QAM

-3

30

17237

12

16-QAM

-4

2014-01-06

NIR

XRV

28800

adjustment
Out of range

HUAWEI Confidential

Page3, Total5

Document Title

Security Level:

Table 7D: CQI mapping table for UE category 10.


CQI value

Transport

Number of Modulation Reference power


HS-PDSCH

Block Size
N/A

137

QPSK

173

QPSK

233

QPSK

317

QPSK

377

QPSK

461

QPSK

650

QPSK

792

QPSK

931

QPSK

10

1262

QPSK

11

1483

QPSK

12

1742

QPSK

13

2279

QPSK

14

2583

QPSK

15

3319

QPSK

16

3565

16-QAM

17

4189

16-QAM

18

4664

16-QAM

19

5287

16-QAM

20

5887

16-QAM

21

6554

16-QAM

22

7168

16-QAM

23

9719

16-QAM

24

11418

16-QAM

25

14411

10

16-QAM

26

17237

12

16-QAM

27

21754

15

16-QAM

28

23370

15

16-QAM

29

24222

15

16-QAM

30

25558

15

16-QAM

2014-01-06

NIR

XRV

28800

adjustment
Out of range

HUAWEI Confidential

Page4, Total5

Document Title

Security Level:

Table 7E: CQI mapping table for UE categories 11 and 12.


CQI value

Transport

Number of Modulation Reference power


HS-PDSCH

Block Size
N/A

137

QPSK

173

QPSK

233

QPSK

317

QPSK

377

QPSK

461

QPSK

650

QPSK

792

QPSK

931

QPSK

10

1262

QPSK

11

1483

QPSK

12

1742

QPSK

13

2279

QPSK

14

2583

QPSK

15

3319

QPSK

16

3319

QPSK

-1

17

3319

QPSK

-2

18

3319

QPSK

-3

19

3319

QPSK

-4

20

3319

QPSK

-5

21

3319

QPSK

-6

22

3319

QPSK

-7

23

3319

QPSK

-8

24

3319

QPSK

-9

25

3319

QPSK

-10

26

3319

QPSK

-11

27

3319

QPSK

-12

28

3319

QPSK

-13

29

3319

QPSK

-14

30

3319

QPSK

-15

2014-01-06

NIR

XRV

4800

adjustment
Out of range

HUAWEI Confidential

Page5, Total5

You might also like