0% found this document useful (0 votes)
490 views

Table 4d4a

1) This document provides the current-carrying capacity in amperes for multicore armored PVC-insulated copper conductor cables under different reference methods and cable configurations. 2) The cable capacities are listed for various copper conductor cross-sectional areas, ranging from 1 to 400 mm2, under ambient temperature of 30°C and conductor operating temperature of 70°C. 3) Reference methods include direct clipping (Method 1), or installation on a perforated horizontal/vertical cable tray (Method 11) or in free air (Method 13), for both two-core single phase cables and three or four-core three phase cables.

Uploaded by

sofyanshah
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
490 views

Table 4d4a

1) This document provides the current-carrying capacity in amperes for multicore armored PVC-insulated copper conductor cables under different reference methods and cable configurations. 2) The cable capacities are listed for various copper conductor cross-sectional areas, ranging from 1 to 400 mm2, under ambient temperature of 30°C and conductor operating temperature of 70°C. 3) Reference methods include direct clipping (Method 1), or installation on a perforated horizontal/vertical cable tray (Method 11) or in free air (Method 13), for both two-core single phase cables and three or four-core three phase cables.

Uploaded by

sofyanshah
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TABLE 4D4A

Multicore armoured pvc- insulated cables


(COPPER CONDUCTOR)
BS 6346
Ambient temperature : 30 C
Conductor operating temperature : 70 C

CURRENT- CARRYING CAPACITY (amperes):


conductor
crosssectional area

Reference Method 1
(clipped direct)

Reference Method 11
(on a perforated horizontal or vertical cable tray)
or Reference Method 13 (free air)
Two-core cable,
Three or four-core cable,
single phase a.c
Three phase a.c
5
6
(A)
(A)
22
19

1
mm
1.5

Two-core cable,
single phase a.c
2
(A)
21

Three or four-core cable,


Three phase a.c
3
(A)
18

2.5
4
6
10
16

28
38
49
67
89

25
33
42
58
77

31
41
53
72
97

26
35
45
62
83

25
35
50
70
95

118
145
175
222
269

102
125
151
192
231

128
157
190
241
291

110
135
163
207
251

120
150
185
240
300

310
356
405
476
547

267
306
348
409
469

336
386
439
516
592

290
332
378
445
510

400

621

540

683

590