This document provides input parameters for sizing an air receiver including a hold-up time of 6 minutes, an air requirement of 30 Nm3/hr, an air temperature of 290°C, a normal operating pressure of 8.5 kg/cm2(g), and a minimum operating pressure of 6 kg/cm2(g). Based on these inputs, the calculated air receiver capacity is 70.89 m3.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
37 views
Air Receiver Sizing
This document provides input parameters for sizing an air receiver including a hold-up time of 6 minutes, an air requirement of 30 Nm3/hr, an air temperature of 290°C, a normal operating pressure of 8.5 kg/cm2(g), and a minimum operating pressure of 6 kg/cm2(g). Based on these inputs, the calculated air receiver capacity is 70.89 m3.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1
Air Receiver sizing:
Input: Hold-up time Air requirement Air temperature Normal operating pressure, P1 Minimum operating pressure, P2 Output: Air Receiver Capacity = 70.89 m3 = = = = = 30 290 50 8.50 6 minutes Nm3/hr o