0% found this document useful (0 votes)
317 views1 page

Plant Performance Guarantees

The document outlines plant performance guarantees for PT. REKADAYA ELEKTRIKA. It guarantees that the works will conform to contract requirements, be suitable for their intended use, and be free from defects. It also guarantees to replace or repair any defective works or portions within the warranty period. Specifically, it guarantees the main transformer will have load losses of 34,555 Watts and no-load losses of 1,555 Watts. It guarantees the station service transformer will have sufficient capacity for auxiliary loads and losses not exceeding 1,555 Watts for load and 755 Watts for no-load.

Uploaded by

imhalida
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
317 views1 page

Plant Performance Guarantees

The document outlines plant performance guarantees for PT. REKADAYA ELEKTRIKA. It guarantees that the works will conform to contract requirements, be suitable for their intended use, and be free from defects. It also guarantees to replace or repair any defective works or portions within the warranty period. Specifically, it guarantees the main transformer will have load losses of 34,555 Watts and no-load losses of 1,555 Watts. It guarantees the station service transformer will have sufficient capacity for auxiliary loads and losses not exceeding 1,555 Watts for load and 755 Watts for no-load.

Uploaded by

imhalida
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

PT.

REKADAYA ELEKTRIKA SCHEDULE 6 Plant Performance Guarantees

SCHEDULE 6 PLANT PERFORMANCE GUARANTEES


6.1 DESIGN, MATERIALS AND WORKMANSHIP The Contractor guarantees that the Works described in his id Pro!osal "ill conform to all the re#uirements of the Contract Document$ be suitable for the ser%ice s!ecified$ and that all e#ui!ment "ill be designed to meet the !erformance re#uirement related to o!eration under seismic conditions as s!ecified and be free from design$ manufacturing and material defects& The Contractor also guarantees that he "ill$ at the con%enience of and "ithout charge to the '"ner$ re!lace or re!air an( of the "orks or !ortion thereof "hich !ro%e defecti%e as a result of fault( materials or "orkmanshi! "ithin the Warrant( Period& 6.2 PLANT PERFORMANCE GUARANTEE The Contractor shall guarantee onl( to the follo"ing) /& 2ain Transformer load losses ) 0& 2ain Transformer no.load losses) 34$555 Watts 1$555 Watts

The Contractor shall !ro%ide Station Ser%ice Transformer *SST+ ha%ing sufficient ca!acit( to su!!l( re#uired !lant au,iliar( loads that shall be measured at the H- terminal of the SST& The Contractor guarantees that losses for the SST shall not e,ceed the follo"ing) a& Load losses ) b& 6o.load losses) 1$555 Watts 755 Watts

Sch.6 . /

PLTP Ulumbu *0 , 0&1 2W+