0% found this document useful (0 votes)
202 views6 pages

Labview Modbus Eng

This document provides instructions for using Modbus in LabVIEW. It describes how to download and install the necessary NI Modbus library. It then provides step-by-step instructions for running examples of Modbus over TCP and Modbus over RTU communications by opening and configuring example VIs and setting parameters like the IP address, baud rate, and slave address.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
202 views6 pages

Labview Modbus Eng

This document provides instructions for using Modbus in LabVIEW. It describes how to download and install the necessary NI Modbus library. It then provides step-by-step instructions for running examples of Modbus over TCP and Modbus over RTU communications by opening and configuring example VIs and setting parameters like the IP address, baud rate, and slave address.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Modbus using in LabVIEW 1. Free download NIs Modbus library (for LabVIEW 7.1) http://sine.ni.com/apps/we/niepd_web_display.display_epd4?

p_guid=F15 82737BACF5CA8E0340003BA7CCD71 or download the MGIModbus (for LabVIEW 6.1) http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=F15 82737BACF5CA8E0340003BA7CCD71 2. Install NIs Modbus library, or unzip MGIModbus and copy the two folders into LabVIEW. Modbus/TCP 1. Open MB Ethernet Example Master.vi from Functions Palette >> User Libraries>> NI Modbus>> MB Ethernet Example Master.vi

2. Double-click the icon to open it

3. Create MBAP Header of MB Ethernet Master Query.vi and link the controller to MB Ethernet Master Query.vi in frame0 ~ frame 3

4. Set IP and NetID of remote Modbus slave

5. Run the VI.

Modbus/RTU 1. Make sure the PC have VISA runtime installed. 2. Open MB Serial Example Master.vi from Functions Palette >> User Libraries>> NI Modbus>> MB Serail Example Master.vi

3. Double-click the icon to open it

4. Set the baud rate of MB Serial Init.vi corresponding with baud rate of Modbus Slave.

5. Modify MB Serial Example Query.vi in frame0 ~ frame3: Set False to Use Modbus Data Unit? and NetID of Slave to Slave Address.

6. Select COM port

7. Run the VI.