Pump
Pump
\
|
+ =
f Re
255 . 1
7 . 3
D /
log 4
f
1
10
Re
16
f =
2
v
D
L
f 4
P
h
2
s
= =
g
F
z
g
p P
NPSH
s
1
v
a
=
o
|
|
.
|
\
|
=
2
v
A
A
1 55 . 0 h
2
2
2
1
2
c
o
|
|
.
|
\
|
=
2
v
A
A
1 h
2
1
2
2
1
e
1. On the Tools menu, click Options, then click the Calculation tab and tick on the Iteration box. On Maximum iterations box write 1000.
- If the pump is below the liquid level in the suction tank, z
1
(cell C38) is positive. If the pump is above the liquid level in the suction tank, z
1
is negative
- If there are not enlargements or contractions in the system, set enlargement and/or contraction coefficients in the cells C27 and C28 equal to 0
b. Turn the "SWITCH" ON (set the value in the cell G1 (red cell) equal to 1 and press ENTER)
d. To recalculate for different parameter values turn the "SWITCH" OFF (set the value in the cell G1 equal to 0 and press ENTER). Repeat steps 2a to 2c
Calculation of friction losses,
required power, developed head and
available NPSH of a pump
Input data
Flow rate Q = 20 m
3
/h
Inside diameter Di = 0.042 m
Pipe length L = 12 m
Suction pipe length Ls= 2 m
Density den = 1050 kg/m
3
Viscosity visc= 0.002 Pas
Enlargement-loss coefficient Ke = 0
Contraction-loss coefficient Kc = 0.55
Valves-loss equivalent length Le/D = 300
Fittings-loss equvalent length Le/D = 32
Number of valves Nv = 1
Number of fittings (90
o
elbows)
Nf = 3
Rafness of the pipe raf = 0 m
Velocity at point 1 v
1
= 0 m/s
Pressure at point 1 P
1
= 101325 Pa
Pressure at point 2 P
2
= 101325 Pa
Vapor pressure in the suction line p
v
= 12349 Pa
Distance of point 1 from reference level z
1
*
= -2
Distance of point 2 from reference level z
2
= 8
Efficiency of the pump n= 70%
* If the pump is above the liquid level in the suction tank, z
1
is negative
Ws
z
1
, P
2
v
2
z
2
x 2
Level of reference
, P
1
v
1
x
1
SWITCH= 1
Derived data
Mass flow rate, = 5.8333 kg/s
Cross sectional area A = 0.00139 m
2
Mean velocity at point 2 v
m2
= 4.010 m/s
Reynolds number Re = 88419
Relative rafness rr = 0
Corection factor o= 1
Results
Friction factor
f = 0.0047
14.6 14.7
Friction losses
Enlargement losses Fe = 0.00 J/kg
Contraction losses Fc = 4.42 J/kg
Valve-equivalent length LeV = 12.60 m
Fitting-equivalent length LeF = 4.03 m
Straight tube losses Fs = 103.26 J/kg
Total friction losses Ft = 107.68 J/kg
Energy and Power added to the fluid by the pump
-w
s
= 213.8 J/kg
-W
s
= 1247.3 W
Required Power (brake power)
-W
sr
= -W
sr
= 1781.8 W
Developed Head
H = H = 21.8 m
Available NPSH
Friction losses in the suction line
-Contraction losses Fcs = 4.42 J/kg
-Fitting-equivalent length LeFs = 1.34 m
-Straight tube losses Fss = 12.06 J/kg
Total friction losses in the suction line Fts = 17.83 J/kg
NPSHa = 4.8 m
m