0% found this document useful (0 votes)
47 views1 page

Model XLK Data Sheet

The document summarizes the specifications of a shackle assembly load cell model XLK for measuring force and pressure. It can measure ranges from 0-1,000 to 0-20,000 lbs and has options for spherical washers, cables, and high resistance bridges. It has performance specifications including excitation output, bridge resistance, insulation resistance, linearity, hysteresis, and thermal effects. Standard orders include calibration certification.

Uploaded by

tungluong
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views1 page

Model XLK Data Sheet

The document summarizes the specifications of a shackle assembly load cell model XLK for measuring force and pressure. It can measure ranges from 0-1,000 to 0-20,000 lbs and has options for spherical washers, cables, and high resistance bridges. It has performance specifications including excitation output, bridge resistance, insulation resistance, linearity, hysteresis, and thermal effects. Standard orders include calibration certification.

Uploaded by

tungluong
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Force

Pressure

Instrumentation

Customized

Shackle Assembly Load Cell

Model XLK

Measuring ranges

0-1,000 to 0-20,000 lbs


Features Set of spherical washers available as an option Cable with mating connector available as an option High resistance bridge available as an option Drawing

99-3829-0000
All dimensions are in inches, unless otherwise noted. Also available in metric units.

PERFORMANCE SPECIFICATIONS (FSO is Full Scale Output) EXCITATION OUTPUT 5 VDC to 15 VDC 4-20mA (2- or 3-wire), 0-5Vdc or 0-10Vdc 700 Ohms Nominal 1 Megaohm 0.15% FSO, Combined 1.0% FSO -50 to +250F (-46 to +121C) 60 to +160F (15 to +71C) 0.05% FSO/F 0.02% Reading/F 400% of Capacity (10:1 @ 2 tons 50,000,000 Tension

Capacity (lbs) 1,000 20,000

Ordering Example XLK-01K XLK-020K

Customized

BRIDGE RESISTANCE INSULATION RESISTANCE LINEARITY HYSTERESIS REPEATABILITY ZERO BALANCE OPERATING TEMP RANGE COMPENSATED TEMP RANGE THERMAL EFFECTS on Zero on Span SAFE OVERLOAD FATIGUE LIFE, NO. OF CYCLES STANDARD CALIBRATION

tecsis LP 771-F Dearborn Park Lane Worthington, OH 43085 Email: [email protected] Internet: www.tecsis.us If you have further questions, please call: (614) 430-0683 Facsmile: 614-431-6957