IES Electrical Engineering Topic wise Questions Measurement & Instrumentation

YEAR 2008 MCQ 1

Assertion (A) : A precision instrument is always accurate. Reason (R) : A precision instrument is one where the degree of reproducibility of the measurements is very good. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 2

Assertion (A) : A PMMC instrument is used for reading both d.c. and a.c. signals. Reason (R) : The deflecting torque in a PMMC instrument is direcrtly proportional to the current in the moving coil. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 3

Assertion (A) : Piezoelectric transducers can be used for measurement of both static and dynamic phenomena.

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com Reason (R) : Piezoelectric transducers have very good high frequency response. (A) Both A and R are true and R is the correct explanation of A. (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 4

Assertion (A) : Capacitive transducers can be used for measurement of both static and dynamic phenomena. Reason (R) : Capacitive transducers are extremely sensitive. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 5

The successive approximation A/D output for a 4-bit converter to a 8.217 volt input (if the reference is 5 V) will be (A) 1101 (B) 0110 (C) 1010 (D) 1001
MCQ 6

Continuous recording of a signal is not possible in a (A) magnetic tape recorder (B) strip chart recorder (C) X-Y recorder (D) Galvanometric recorder
MCQ 7

Which one of the following techniques reduces the residual inductance of standard resistance ? (A) Using high resistivity material
Page 2

www.gatehelp.com (B) Using material of low temperature coefficient of resistance (C) Using proper shielding (D) Making a bifilar winding on a card
MCQ 8

IES EE Topic wise 2001-2008 Measurement & Instrumentation

In an electrometer, the movable plate is 11 cm in diameter. When 12 kV is applied between the movable plate and the fixed plate, the force is 0.006 N. The change in capacitance for 1.5 mm movement of the movable plate is (A) 0.44 # 10 12 F (B) 0.37 # 10 6 F (C) 0.125 # 10 12 F (D) 12.5 # 10 12 F
MCQ 9

In a CRO astigmatism is (A) a source of generating fast electrons (B) a medium for absorbing secondary emission electrons (C) an additional focus control (D) a time-delay control in the vertical deflection system
MCQ 10

Schering bridge can be used to measure which one of the following ? (A) Q of a coil (B) Inductance and its Q -value (C) Very small resistance (D) Capacitance and its power factor
MCQ 11

Inductance is measured by which one of the following ? (A) Wien bridge (B) Schering bridge (C) Maxwell bridge (D) Owen bridge
Page 3

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 12

The dielectric loss of a capacitor can be measured by which one of the following ? (A) Wien bridge (B) Owen bridge (C) Schering bridge (D) Maxwell bridge
MCQ 13

Which bridge is used to determine frequency ? (A) Anderson bridge (B) De Sauty bridge (C) Wien bridge (D) Campbell bridge
MCQ 14

For low resistance (from few micro ohms to one ohm) measurement, which bridge is used ? (A) Wheatstone bridge (B) Kelvin bridge (C) Guarded Wheatstone bridge (D) Maxwell bridge
MCQ 15

Which amplifier is used in an electronic multimeter ? (A) Power amplifier (B) Buffer amplifier (C) Differential amplifier (D) Wideband amplifier
MCQ 16

Which displacement transducer is used for accurate and linear measurement ? (A) LVDT (B) Strain gauge
Page 4

www.gatehelp.com (C) Potentiometer (D) Capacitive displacement transducer


MCQ 17

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Match List I with List II and select the correct answer using the codes given below the lists : List I A. B. C. Variable capacitance device 1. Orifice meter Thermistors 2. 3. 4. Codes : A (A) (B) (C) (D) 3 2 2 3 B 1 4 1 4 C 2 3 3 2 List II Flow measurement Temperature measurement Pressure tansducer Force and torque measurement

MCQ 18

Which of the following primary detector type transducers are employed for displacement measurement ? 1. Thermistor 2. 3. 4. Diaphragm Thermocouple Pivot Torque

Select the correct answer using the code given below : (A) 1 and 2 (B) 2 and 4 (C) 3 and 4 (D) 1 and 4
MCQ 19

The instrumentation amplifiers are used principally to amplify signals


Page 5

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com from which of the following ? (A) Transducers (B) Active fillers (C) Choppers (D) D/A converters
MCQ 20

The principles of Hall effect of made use of in the construction of which one of the following ? (A) Ammeter (B) Voltmeter (C) Gaussmeter (D) Galvanometer
MCQ 21

Which one of the following is the correct statement? The type of majority charge carriers in a semiconductor can be found by (A) Hall effect (B) Piezoelectric effect (C) Photoelectric effect (D) Meissner effect
MCQ 22

Which one of the following passive components has the most precise and accurate standard ? (A) Resistance (B) Inductance (C) Capacitance (D) Conductance
MCQ 23

What is the prefix tera equivalent to ? (A) 103 (B) 106 (C) 109
Page 6

www.gatehelp.com (D) 1012


MCQ 24

IES EE Topic wise 2001-2008 Measurement & Instrumentation

The errors introduced by an instrument fall in which category ? (A) Systematic errors (B) Random errors (C) Gross errors (D) Environmental errors
MCQ 25

A waveform shown in the figure below, is fed to a.c. ammeter. What is the reading shown by the meter ?

(A) Zero (B) 50 mA (C) 75 mA (D) 100 mA


MCQ 26

Which one of the following instruments is commonly used to measure primary current of a transformer connected to mains ? (A) Electrostatic meter (B) Current transformer (C) Moving coil type meter (D) Moving iron meter
MCQ 27
Page 7

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com What is clamp-on ammeter used for ? (A) Low a.c. current (B) High a.c. current (C) Low d.c. current (D) High d.c. current
MCQ 28

Which one of the following is used for the measurement of 3-phase power factor ? (A) Power factor meter (B) Crossed-coil power factor meter (C) Phase-angle watt hour meter (D) Polarised-vane power factor meter
MCQ 29

What is the swamping resistance which is connected in series with the working coil of a voltmeter to drastically reduce the error in measurement caused due to variation in temperature, made of ? (A) Constant (B) Eureka (C) Manganin (D) Nichrome
MCQ 30

How can a milli-ammeter be used as a voltmeter ? (A) By connecting a low resistance in parallel with the instrument (B) By connecting a high resistance in parallel with the instrument (C) By connecting a low resistance in series with the instrument (D) By connecting a high resistance in series with the instrument
MCQ 31

Due to which one of the following reasons bearing of PMMC Instrument are made of Jewel ? (A) To avoid wear and tear of the moving system (B) To provide a small support
Page 8

www.gatehelp.com (C) It can be easily replaced (D) To make the system robust
MCQ 32

IES EE Topic wise 2001-2008 Measurement & Instrumentation

The imperfect capacitance which is shunted by a resistance can be measured by which one of the following ? (A) Carey Foster bridge (B) Owen bridge (C) Schering bridge (D) Wien bridge
MCQ 33

What is a differentia transformer ? (A) Constant pressure transducer (B) Variable pressure transducer (C) Constant displacement transducer (D) Variable inductance transducer

YEAR 2007 MCQ 34

Assertion (A) : The precision instruments are always accurate. Reason (R) : Precision indicates the degree of agreement within a set of measurement of the same quantity by the instrument, and accuracy refers of the degree of closeness to the true value of the quantity to be measured. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 35

Assertion (A) : The accuracy of the null detector does not play any role in a bridge measurement.
Page 9

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com Reason (R) : Under balance condition of the bridge, no current flows through the null detector. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 36

Assertion (A) : Usually the magnetic recording head of a tape recorder is provided with a.c. bias for its operation. Reason (R) : It is more convenient to provide a.c. bias to the magnetic recording head as compared to the d.c. bias. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true R is false (D) A is false but R is true
MCQ 37

Assertion (A) : Dual slope ADC is the most preferred digital conversion approach in digital multimeters. Reason (R) : Dual slope ADC provides high accuracy in A/D conversion which at the same time suppressing the hum effect on the input signal. (A) Both A and R are true and R is the correct explanation of A (B) Both A and R are true but R is not the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 38

Which one of the following is the correct statement ? Due to inductance in the pressure coil, the dynamometer wattmeter (A) reads low on lagging p.f. and high on leading p.f. (B) reads high on lagging p.f. and low on leading p.f. (C) reading is not affected at all (D) always reads low
Page 10

www.gatehelp.com
MCQ 39

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which one of the following is the main cause of creeping in the induction type energy meters ? (A) Friction compensation (B) Lag/Lead compensation (C) Overload compensation (D) Braking torque producing system
MCQ 40

Match List I (Name of Instrument) with List II (Classification) and select the correct answer using the codes given below the lists : List I A. B. C. Ohmmeter Watt hour meter Null balance recorders 1. 2. 3. List II Absolute Indicating Recording Integrating

D. Raleigh current balance 4. Codes : A (A) 1 (B) 2 (C) 2 (D) 1


MCQ 41

B 2 4 4 2

C 3 3 1 4

D 4 1 3 3

Which of the following statements are correct in case of a power factor meter ? 1. The deflection is proportional to the phase angle between field coil and crossed coil. 2. 3. The restoring torque is provided by a controlling torque. It consists of two coils mounted at right angles to each other.

Select the correct answer using the code given below : (A) 1 and 2 (B) 2 and 3 (C) 1 and 3 (D) 1, 2 and 3
Page 11

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 42

In a low power factor wattmeter, why is a compensating coil employed ? (A) To neutralize the capacitive effect of pressure coil (B) To compensate for inductance of pressure coil (C) To compensate for the error caused by power loss in the pressure coil (D) To compensate for the error caused by eddy currents
MCQ 43

Which one of the following instruments is used for standardization of a Drysdale a.c. potentiometer ? (A) Rectifier type ammeter (B) PMMC ammeter (C) Precision type electrodynamometer ammeter (D) Thermocouple ammeter
MCQ 44

Match List I (Property) with List II (Type of the Instrument) and select the correct answer using the codes given below the lists : List I A. B. C. Linear scale 1. True r.m.s. up to RF 2. range r.m.s. only for 3. sinusoidal input List II Thermocouple type Rectifier type Moving iron type Permanent magnet moving coil type

D. Reads r.m.s. value 4. using square law scale Codes : A (A) (B) (C)
Page 12

B 4 1 1

C 3 2 3

D 2 3 2

1 4 4

www.gatehelp.com (D) 1 4 2 3

IES EE Topic wise 2001-2008 Measurement & Instrumentation

MCQ 45

Flux meter is a special type of ballistic galvanometer provided with which one of the following ? (A) Heavy electromagnetic damping and very small controlling torque (B) Heavy electromagnetic damping and very large controlling torque (C) Small electromagnetic damping and small controlling torque (D) Large controlling torque and small electromagnetic damping
MCQ 46

Why is damping of a ballistic galvanometer kept small ? (A) To get minimum overshoot (B) To make the system critically damped (C) To make the system oscillatory (D) To get first deflection large
MCQ 47

Match List I (Name of Instrument) with List II (Frequency Range) and select the correct answer using the codes given below the lists : List I A. B. C. Telephone detector Vibration galvanometer Tunable amplifier 1. 2. 3. 4. List II 200 Hz 100 Hz 1 kHz dc

D. D Arsonval galvanometer Codes : A (A) (B) (C) (D) 3 2 3 2 B 4 1 1 4 C 2 3 2 3 D 1 4 4 1

MCQ 48

In an analog Data Acquisition System (DAS), what is the correct


Page 13

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com sequence of the blocks (therein) starting from the input ? (A) Transducer - recorder - filter - signal conditioner (B) Transducer - signal conditioner - recorder (C) Signal conditioner - transducer - recorder (D) Signal conditioner - filter - transducer - recorder
MCQ 49

Which one of the following pressure transducers is suitable for measurement of high pressure ? (A) Alphatron (B) McLeod Gauge (C) Pirani Gauge (D) Bourdon Gauge
MCQ 50

Which one of the following transducers is an active transducer ? (A) Piezo-electric pressure transducer (B) Metallic strain gauge (C) Semi-conductor strain gauge (D) Platinum resistance thermometer
MCQ 51

In strain gauge torque transducers, the strain gauges are mounted at which one of the following ? (A) 0c to the shaft axis (B) 45c to the shaft axis (C) 90c to the shaft axis (D) at any angle with the shaft axis
MCQ 52

Match List I (Type of Digital Voltmeter) with List II (It construction features) and select the correct answer using the codes given below the lists : List I
Page 14

List II

www.gatehelp.com A. B. Basic ramp type DVM Staircase-ramp type DVM 1. 2. Uses D/A converter Ture average value of input voltage using voltage frequency converter Servo-driven potentiometer is commonly used Does not use D/A converter

IES EE Topic wise 2001-2008 Measurement & Instrumentation

C.

Integrating type DVM

3.

D. Continuous balance type 4. DVM Codes : A (A) (B) (C) (D) 1 4 1 4 B 2 1 2 1 C 3 2 4 3 D 4 3 3 2

MCQ 53

The measurement of very low and very high frequencies is invariably done using a frequency counter in which one of the following ? (A) Frequency measurement mode only (B) Period measurement mode only (C) Frequency and period measurement modes, respectively (D) Period and frequency measurement modes, respectively
MCQ 54

Why is strain gauge bridge sometimes excited with ac ? (A) It has a stable performance with ac (B) Its sensitivity is more with ac (C) Power frequency pick-up can be avoided with ac (D) ac output can be easily amplified
MCQ 55

Which of the following are the advantages of a balanced bridge vacuum tube voltmeter in comparison with a conventional VTVM ? 1. Higher input impedance.
Page 15

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com 2. 3. Effect of changes due to variation in value characteristics is minimized. Power supply fluctuations have less effect on measurement.

Select the correct answer using the code given below : (A) 1 and 2 (B) 2 and 3 (C) 1 and 3 (D) 1, 2 and 3
MCQ 56

What is the approximate input impedance of a CRO ? (A) Zero (B) 1 M (C) 10 (D) 10
MCQ 57

Match List I (Type of Electronic Voltmeter) with List II (Leading Characteristics) and select the correct answer using the codes given below the lists : List I A. B. C. Amplifier Rectifier 1. Rectifier Amplifier 2. True RMS 3. 4. List II Wide input signal, dynamic range High resistivity, limited bandwidth Limited resistivity,large bandwidth Capability to read non-sinusoidal AC

D. Logarithmic Codes : A (A) (B) (C) (D) 1 2 1 2 B 2 3 2 3 C 3 4 4 1

D 4 1 3 4

MCQ 58
Page 16

www.gatehelp.com Hays bridge is suitable for the measurement of which one of the following ? (A) Inductance with Q < 10 (B) Inductance with Q > 10 (C) Capacitance with high dissipating factors (D) Capacitance with low dissipating factors
MCQ 59

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which one of the following bridges is used for measurement of dielectric loss and power factor of a capacitor ? (A) Maxwells bridge (B) Anderson bridge (C) De Sauttys bridge (D) Scherring bridge
MCQ 60

The resolution of Digital-to-Analog converter is governed by which one of the following (where n is the number of digital inputs) ? (A) 2n (B) 2/n (C) (2) n (D) 2n

MCQ 61

A thermo-couple arrangement is to be used to measure temperature in the range of 700 800cC . Which one of the following pairs would be most suitable ? (A) Copper-constantan (B) Iron-constantan (C) Chromel-alumel (D) Platinum-platinum rhodium

YEAR 2006 MCQ 62


Page 17

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com Assertion (A) : It is always desirable to take the reading of an indicating instrument very close to the full-scale reading. Reason (R) : Accuracy of an indicating instrument is maximum at the full-scale deflection and error increases as reading comes closer to the beginning of the scale.
MCQ 63

Assertion (A) : The rotating disc in an energy meter is made up of a magnetic material. Reason (R) : Braking takes place due to eddy current generated by the braking magnet.
MCQ 64

Assertion (A) : General purpose dynamometer type Wattmeter cannot indicate the correct value of power at low power factors. Reason (R) : The presence of self-inductance in the pressure coil circuit introduces an error in the indicated value which increases appreciably with decrease in power factor.
MCQ 65

A rectifier instrument is used to measure an alternating square wave of amplitude 100 V. What is the meter reading ? (A) 100 V (B) 70.7 V (C) 111 V (D) None of these
MCQ 66

For defining the standard meter, wavelength of which material is considered ? (A) Neon (B) Krypton (C) Helium (D) Xenon
Page 18

www.gatehelp.com
MCQ 67

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Match List I with List II and select the correct answer using the code given below the lists : List I A. B. C. Bolometer 1. List II Measurement of temperature of a furnace Measurement of high pressure Measurement of flow of air around an aeroplane Measurement of power at 500 MHz Measurement of angular position

Hot-wire Anemometer 2. C-type Bourdon Tube 3. 4. 5.

D. Optical Pyrometer

Codes : A (A) (B) (C) (D) 2 4 2 4 B 3 1 1 3 C 5 2 5 2 D 1 3 3 1

MCQ 68

What is the range for a 3 1 digital meter ? 2 (A) 0 to 1999 (B) 0 to 1500 (C) 0 to 999 (D) 0 to 19999

MCQ 69

Which one of the following is represented by the circuit shown below


Page 19

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com

(A) DeSauty bridge (B) Anderson bridge (C) Heaviside-Campbell bridge (D) Hay bridge
MCQ 70

What should be the main characteristic(s) of the null detector in a bridge measurement ? 1. 2. 3. 4. Accuracy Precision Sensitivity Resolution

Select the correct answer using the code given below : (A) Only 1 and 2 (B) Only 2 and 3 (C) Only 3 and 4 (D) Only 3
MCQ 71

A moving-coil instrument gives full-scale deflection for 1 mA and has a resistance of 5 . If a resistance of 0.55 is connected in parallel to the instrument, what is the maximum value of current it can measure ? (A) 5 mA (B) 10 mA (C) 50 mA (D) 100 mA
Page 20

www.gatehelp.com
MCQ 72

IES EE Topic wise 2001-2008 Measurement & Instrumentation

A single slide wire is used for the measurement of current in a circuit. The voltage drop across a standard resistance of 1.0 is balanced at 70 cm. What is the magnitude of the current, if the standard cell having an e.m.f of 1.45 volts is balanced at 50 cm ? (A) 3.09 A (B) 2.65 A (C) 2.03 A (D) 1.45 A
MCQ 73

When reading is taken at half scale in the instrument, the error is (A) exactly equal to half of full-scale error (B) equal to full-scale error (C) less than full-scale error (D) more than full-scale error
MCQ 74

Match List I (Parameter to be measured) with List II (Instrument to be Used) and select the correct answer the using the codes given below the lists : List I A. B. C. Average value of current RMS value of current Frequency of a wave 1. 2. 3. 4. List II Self-balncing bridge Wien bridge PMMC ammeter Moving-iron ammeter

D. Strain gauge resistance Codes : A (A) (B) (C) (D) 3 2 3 2 B 4 1 1 4 C 2 3 2 3 D 1 4 4 1

Page 21

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 75

Match List I with List II and select the correct answer using the codes given below the lists : List I A. B. C. Digital Counter Schering Bridge Megger 1. 2. 3. 4. List II Measurement of harmonics Measurement of frequency Measurement of dielectric loss Measurement of insulation resistance

D. Spectrum Analyzer Codes : A (A) (B) (C) (D) 1 2 1 2 B 3 4 4 3 C 4 3 3 4 D 2 1 2 1

MCQ 76

Which of the following factors limit the deflection of the pointer of a PMMC instrument to about 90c ? 1. 2. 3. 4. Its damping mechanism Linearity of the magnetic field in which the coil moves Control spring arrangement Shape of the pole shoe of the horseshoe magnet

Select the correct answer using the code given below : (A) Only 1 and 3 (B) Only 2 and 4 (C) Only 2 and 3 (D) Only 1 and 4
MCQ 77

Which of the following indicating instruments has/have linear scale ? 1.


Page 22

Moving-iron meter

www.gatehelp.com 2. 3. 4. Permanent magnet moving-coil meter Thermocouple meter Rectifier type meter

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Select the correct answer using the code given below : (A) Only 1 and 2 (B) Only 2 and 3 (C) Only 3 and 4 (D) Only 2
MCQ 78

A sinusoidal voltage of 1 V r.m.s value at 10 Hz is applied across the two terminals of a PMMC type of voltmeter. What is the deflection of the pointer ? (A) Zero volt (B) 1 volt (C) 2 volt (D) The pointer oscillates around zero volt
MCQ 79

Match List I (Instrument) with List II (Error) and select the correct answer using the codes given below the lists : List I A. B. C. PMMC voltmeter AC ammeter Current transformer 1. 2. 3. 4. List II Eddy current error Phase angle error Breaking system error Temperature error

D. Energy meter Codes : A (A) (B) (C) (D) 2 4 2 4 B 3 1 1 3 C 4 2 4 2 D 1 3 3 1

Page 23

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 80

Maxwells inductance-capacitance bridge is used for measurement of inductance of (A) low Q coils only (B) medium Q coils only (C) high Q coils only (D) low and medium Q coils
MCQ 81

The materials to be used in the manufacture of a standard resistance should be of (A) high resistivity and low temperature coefficient (B) low resistivity (C) high temperature coefficient (D) low resistivity and high temperature coefficient
MCQ 82

What is the series resistance required to extend the 0-100 V range of a 20000 /V meter to 0-1000 V ? (A) 10 M (B) 16 M (C) 18 M (D) 20 M
MCQ 83

The voltage coil of a single-phase house service energy meter (A) is highly resistive (B) is highly inductive (C) is highly capacitive (D) has a phase angle equal to load power factor angle
MCQ 84

Which of the following can be used/modified for measurement of angular speed ? 1. LVDT
Page 24

www.gatehelp.com 2. 3. 4. Magnetic pick-up Tacho-generator Strain gauge

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Select the correct answer using the code given below : (A) Only 1 and 2 (B) Only 2 and 3 (C) Only 3 (D) Only 2, 3 and 4
MCQ 85

Piezo-electric crystal is generally employed for the measurement of which one of the following ? (A) Flow (B) Velocity (C) Acceleration (D) Temperature
MCQ 86

In microwave telemetry, repeater stations are required at every (A) 2 km (B) 5 km (C) 40 km (D) 100 km
MCQ 87

Data acuistion system are usually of (A) analog type (B) digital type (C) integrating type (D) hybrid type
MCQ 88

A successive approximation A/D converter has a resolution of 20 mV. What is its digital output for an analog input of 2.17 V ?
Page 25

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (A) 01101100 (B) 01101101 (C) 01101011 (D) 01110100


MCQ 89

A doctor is using a digital clinical thermometer, which employs an A/D converter. The converter provides for both + ve and ve reference inputs in place of only + ve and ground potential reference inputs. V+ref = 2.16 V and Vref = 1.85 V . The amplifier used for the converter input generates signal of 20 mV per cF of body temperature. The converter output is between 00000 and 11111. Which one of the following is correct ? (A) The thermometer range is 92.5cF to 108cF (B) The thermometer range is 46cF to 216cF (C) The thermometer range is 0cF to 108cF (D) The thermometer cannot by used to measure body temperature 98.4cF
MCQ 90

Which of the following bridges can be used to construction a harmonic distortion analyzer ? 1. 2. 3. 4. Maxwell bridge Hay bridge Schering bridge Wien bridge

Select the correct answer using the code given below : (A) Only 1 and 2 (B) Only 2 and 3 (C) Only 3 and 4 (D) Only 4
MCQ 91

One cycle of a square wave signal observed on an oscilloscope is found to occupy 6 cm at a scale setting of 30 s/cm . What is the signal
Page 26

www.gatehelp.com frequency ? (A) 1.8 kHz (B) 5.55 kHz (C) 18 kHz (D) 55.5 kHz

IES EE Topic wise 2001-2008 Measurement & Instrumentation

YEAR 2005 MCQ 92

A set of independent current measurements taken by four observers was recorded as : 117.02 mA, 117.11 mA, 117.08 mA and 117.03 mA. What is the range of error ? (A) ! 0.045 (B) ! 0.054 (C) ! 0.065 (D) ! 0.056
MCQ 93

The reference voltage and the input voltage are sequentially connected to the integrator with the help of a switch in a (A) Successive approximation A/D converter (B) Dual slope integration A/D converter (C) Voltage to time converter (D) Voltage to frequency converter
MCQ 94

A single channel digital storage oscilloscope uses a 12 bit, 10 8 samples/s ADC. For a 10 kHz sine wave input, what is the number of samples taken per cycle of input ? (A) 1012 (B) 108 (C) 10 4 (D) 102
Page 27

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 95

Consider the signal Vm sin 100t + 2Vm sin 200t to be sampled and stored in a data acquisition system. The same is to be extracted off-line later on. In order to extract the signal effectively, the original sampling frequency has to be (A) 100 rad/s (B) 200 rad/s (C) 210 rad/s (D) 100 2 + 200 2 rad/s

MCQ 96

Which one of the following transmission systems for telemetry has largest bandwidth ? (A) FM/FM radio transmission system (B) Co-axial copper cables transmission system (C) Fibre-optic data transmission system (D) Synchro-position repeater system
MCQ 97

Why are dummy strain gauges employed ? (A) For calibration of strain gauges (B) For increasing the sensitivity of the bridge (C) For the compensation of temperature variations (D) For neutralizing the influence of bridge voltage supply variations
MCQ 98

Match List I (Type of DVM) with List II (sub-component in ADC) and select the correct answer using the codes given below the lists : List I A. B. C.
Page 28

List II 1. 2. 3. 4. DAC Voltage to time converter Pulse-generator Potentiometer

Ramp type Dual-slope Servo-type

D. Successive approximation

www.gatehelp.com 5. Codes : A (A) (B) (C) (D) 2 4 2 4 B 1 5 5 1 C 4 3 4 3 D 5 1 1 5 Capacitor

IES EE Topic wise 2001-2008 Measurement & Instrumentation

MCQ 99

In modern electronic multimeter a FET or MOSFET is preferred over BJT because (A) Its input resistance is low (B) Its input resistance is high (C) Its input resistance is high and does not vary with the change of range (D) It is cheaper
MCQ 100

Which of the following bridges can be used for inductance measurement ? 1. 2. 3. 4. 5. Maxwells bridge Schering bridge Wein bridge Hays bridge Wheatstone bridge

Select the correct answer using the codes given below : (A) 1 and 2 (B) 2 and 3 (C) 3, 4 and 5 (D) 1 and 4
MCQ 101

Match List I (Frequency) with List II (Detector) and select the


Page 29

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com correct answer using the codes given below the lists : List I A. B. C. Zero frequency 50 Hz 1200 Hz 1. 2. 3. 4. 5. Codes : A (A) (B) (C) (D) 2 3 2 3 B 1 4 4 1 C 5 1 1 5 D 3 2 3 2 List II Head phone D Arsonval galvanometer Cathode ray oscilloscope Vibration galvanometer Ballistic galvanometer

D. 10 KHz

MCQ 102

Which of the following factors decide the accuracy in a bridge measurement ? 1. 2. 3. 4. Accuracy of the null indicator Accuracy of the bridge components Sensitivity of the null indicator Applied voltage to the bridge system

Select the correct answer using the codes given below : (A) 1 and 2 (B) 2 and 3 (C) 3 and 4 (D) 1 and 3
MCQ 103

Match List I (Material Used in Instruments) with List II (Purpose) and select the correct answer using the codes given below the lists : List I A.
Page 30

List II 1. Coils

Phosphor-bronze

www.gatehelp.com B. C. Manganin Aluminium 2. 3. 4. 5. Codes : A (A) (B) (C) (D) 3 2 3 2 B 5 4 4 5 C 2 1 2 1 D 4 5 5 4 Discs Control Springs Shunts Multipliers

IES EE Topic wise 2001-2008 Measurement & Instrumentation

D. Eureka

MCQ 104

Match List I (Type of Electronic Voltmeter) with List II (Major Characteristic) and select the correct answer using the codes given below the lists : List I A. B. C. Amplifier-rectifier dynamic 1. range Rectifier-amplifier True R.M.S. 2. 3. 4. List II Wide input-signal High sensitivity, bandwidth Limited sensitivity, bandwidth Capability to sinusoidal ac read limited large non-

D. Logarithmic Codes : A (A) (B) (C) (D) 4 2 4 2 B 1 3 3 1 C 2 4 2 4 D 3 1 1 3

MCQ 105
Page 31

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com What is the effect of inductance in the pressure coil on performance of a dynamometer type wattmeter ? (A) It reads low on lagging power factor and high on leading power factor (B) It reads high on lagging power factor and low on leading power factor. (C) Its reading is not affected at all (D) It always reads low
MCQ 106

To measure 5 volts, if one selects a 0-100 volt range voltmeter which is accurate with in ! 1% , then the error in this measurement may be up to (A) ! 1.5 % (B) ! 2.5 % (C) ! 7.5 % (D) ! 20 %
MCQ 107

Match List I (Specifications of Voltages to be Measured) with List II (Type of Most Suitable Instruments) and select the correct answer using the codes given below the lists : List I A. B. C. 0-10 mV from a source of 1. internal resistance of 1 M Thermo-emf ranging up to 2. 5 mV from a thermocouple Supply voltage of 230 V, 50 3. Hz List II Thermal Moving Iron Permanent magnet moving coil Electronic

D. R.M.S. value of a voltage 4. containing dc and ripples of 50 Hz and harmonic 5. Codes : A


Page 32

Basslistic Galvanometer

www.gatehelp.com (A) (B) (C) (D) 2 4 2 4 3 1 1 3 5 2 5 2 1 3 3 1

IES EE Topic wise 2001-2008 Measurement & Instrumentation

MCQ 108

A 12 bit A/D converter has a range 0-10 V. What is the approximate resolution of the converter ? (A) 1 mV (B) 2.5 mV (C) 2.5 V (D) 12 mV
MCQ 109

Pulse code modulation is commonly used in telemetry because (A) It ensures immunity from noise during transmission (B) The bandwidth requirement of the channel is reduced (C) It removes quantization error (D) It permits lower rate of sampling than what is normally required under Shanons theorem.
MCQ 110

In an analog data acquisition unit, what is correct sequence of the blocks starting from the input ? (A) Transducer-Recorder-Signal conditioner (B) Transducer-signal conditioner-Recorder (C) Signal conditioner-Transducer-Recorder (D) Signal conditioner-Recorder-Transducer
MCQ 111

Thermistors are essentially semiconductors (A) Well suited to precision measurement of temperature (B) Widely used in the lower temperature range of 100c C to 300c C (C) Which behave as resistors with a high negative temperature
Page 33

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com coefficient of resistance (D) All of the above


MCQ 112

Which one of the following frequency meter is suitable for measuring radio frequency ? (A) Vibrating reed frequency meter (B) Weston frequency meter (C) Electrical resonance frequency meter (D) Hetrodyne frequency meter
MCQ 113

Which one of the following digital voltmeters is most suitable to eliminate the effect of period noise ? (A) Ramp type digital voltmeter (B) Integrating type digital voltmeter (C) Successive approximation type digital voltmeter (D) Servo type digital voltmeter
MCQ 114

Chopper stabilized d.c. amplifier type electronic voltmeter overcomes the effect of (A) Amplifier CMRR (B) Amplifier sensitivity (C) Amplifier drift (D) Electromagnetic interference
MCQ 115

Which of the following measurements can be made using Lissajous figures ? 1. Frequency 2. 3. 4. 5.
Page 34

Phase difference Time interval between pulses Pulse width Fundamental and higher harmonic components

www.gatehelp.com Select the correct answer using the code given below : (A) 1 and 2 (B) 2 and 3 (C) 3 and 4 (D) 4 and 5
MCQ 116

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Wagner Earth devices in AC bridge circuits are used for (A) Shielding all the bridge elements from external magnetic field (B) Eliminating the effect of stray capacitance (C) Minimizing the effect of inter-component capacitance (D) Eliminating all the node to earth capacitances
MCQ 117

Which one of the following defects is responsible for creeping in an induction type energy meter ? (A) Imperfect lag compensation (B) Over friction compensation (C) Imperfect overload compensation (D) Misalignment of brake magnet.
MCQ 118

Consider the following statements : 1. 2. 3. 4. Buffer Differentiator Integrator Comparator

Which of the above is/are components in a dual slope integrating type voltmeter ? (A) 1, 3 and 4 (B) 1 and 2 (C) 3 and 4 (D) 2 only
Page 35

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 119

Beam of electrons in a cathode ray tube emanates because of (A) Second emission (B) Thermionic emission (C) Diffusion (D) Post acceleration Direction : The following 2 (Two) items consist of two statements, one labelled as the Assertion (A) and the other as Reason (R). You are required to examine these two statements carefully and select the correct answer using the code given below : (A) Both A and R are individually true and R is the correct explanation of A (B) Both A and R are true but R is NOT the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 120

Assertion (A) : The flux densities used in PMMC instruments vary from 0.1 T to 1.0 T. Reason (R) : The power requirement for PMMC movement to give full scale deflection is small ranging from 25 W to 200 W .
MCQ 121

Assertion (A) :The PMMC type of indicating instruments are always critically damped. Reason (R) : A critically damped system directly moves to its steady state without oscillation.
YEAR 2004 MCQ 122

Match List I (Accuracy) with List II (Type of the standard) and select the correct answer : List I
Page 36

List II

www.gatehelp.com A. B. C. Least accurate More accurate Much more accurate 1. 2. 3. 4. Primary Secondary Working International

IES EE Topic wise 2001-2008 Measurement & Instrumentation

D. Highest possible accurate Codes : A (A) (B) (C) (D) 3 1 3 1 B 4 4 2 2 C 1 3 1 3 D 2 2 4 4

MCQ 123

Which one of the following statements is correct ? The application of the instrument in wrong manner in the procedure of measurement results in a/an (A) systematic error (B) random error (C) gross error (D) instrument error
MCQ 124

A 0 to 200 V voltmeter has a guaranteed accuracy of 1% of full scale reading. The voltage measured by this instrument is 50 V. What is the limiting error ? (A) 4 % (B) 2 % (C) 1 % (D) 0.25 %
MCQ 125

Which one of the following statements correctly represents the systematic errors ? (A) These errors can be calculated form the details of the instruments
Page 37

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (B) These are the residual errors (C) These errors may occur under controlled conditions (D) These are the errors committed by the experiments
MCQ 126

A resistor R is measured using the V - I method, with V rad as 10.14 V and I as 5.07 mA. Which one of the following expresses the value of resistance ? (A) 2 k (B) 2.00 k (C) 2000 (D) 2.0 k
MCQ 127

Which one of the following statements is correct ? The deflection of hot wire instrument depends on (A) r.m.s value of the a.c. current (B) r.m.s value of the a.c. voltage (C) average value of the a.c. current (D) average value of the a.c. voltage
MCQ 128

Which one of the following materials is used in the fabrication of swamping resistance of a PMMC instrument ? (A) Copper (B) Aluminium (C) Manganin (D) Tungsten
MCQ 129

Which one of the following is basically a current sensitive instrument ? (A) Permanent magnet moving coil instrument (B) Cathode ray oscilloscope (C) Electrostatic instrument
Page 38

www.gatehelp.com (D) FET input electronic voltmeter


MCQ 130

IES EE Topic wise 2001-2008 Measurement & Instrumentation

A d Arsonval movement with internal resistance R = 100 and full scale current of 1 mA is to be converted into (0 10) V range. What is the required resistance ? (A) 10 k (B) 10100 (C) 9900 (D) 12000
MCQ 131

Which one of the following types of instruments can be used to determine the r.m.s value of a.c. voltage of high magnitude 10 kV and of any wave shape ? (A) Moving iron instruments (B) Dynamometer type instruments (C) Induction instruments (D) Electrostatic instruments
MCQ 132

The battery cells in an electronic multimeter are required to measure which one of the following ? (A) Resistance (B) Voltage (C) Current (D) Power
MCQ 133

Which one of the following methods decreases the error due to connections in a dynamometer type Wattmeter ? (A) Using bifilar compensating winding in place of current coil (B) Using non-inductive pressure coil circuit (C) Using a capacitor across a part of high resistance of pressure coil circuit
Page 39

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (D) Using a swamping resistance


MCQ 134

The power of a three-phase, three-wire balanced system was measured by two Wattmeter method. The reading of one of the Wattmeters was found to be double that of the other. What is the power factor of the system ? (A) 1 (B) 0.866 (C) 0.707 (D) 0.5
MCQ 135

Match List I (Instruments) with List II (Application) and select the correct answer using the codes given below : List I A. B. C. Dynamometer instrument 1. Thermocouple instrument Ramp generator based 2. 3. 4. List II True r.m.s. value meter Transfer instrument between a.c. and d.c. Time base of CRO Standard of Electromotive force (Emf)

D. Weston Standard Cell Codes : A (A) (B) (C) (D) 4 4 2 2 B 1 3 1 3 C 3 1 3 1 D 2 2 4 4

MCQ 136

Low resistance from few ohms down to one micro ohm is measured using which one of the following instruments ? (A) Ohmmeter (B) A series type ohmmeter
Page 40

www.gatehelp.com (C) A shunt type ohmmeter (D) A voltmeter and an ammeter


MCQ 137

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which one of the following statements is correct ? An electronic voltmeter is more reliable as compared to multimeter for measuring voltage across low impedance because (A) its sensitivity is high (B) it offers high input impedance (C) it does not alter the measured voltage (D) its sensitivity and input impedance are high and do not alter the measured value
MCQ 138

Which one of the following decides the precision of integrating digital voltmeter ? (A) Reference voltage of analog comparator (B) Slope of the generated ramp (C) Width of the generated pulses (D) Electronic counter
MCQ 139

Which one of the following statements is correct ? Spiral springs are used in the instruments to (A) provide controlling torque (B) provide damping torque (C) lead the current to moving coil as well as to provide the controlling torque (D) provide linear deflection
MCQ 140

Which one of the following decides the time of response of an indicating instrument ? (A) Deflecting system (B) Controlling system
Page 41

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (C) Damping system (D) Pivot and Jewel bearing


MCQ 141

Which one of the following is measured by the loss of charge method ? (A) Low R (B) High R (C) Low L (D) High L
MCQ 142

Which one of the following gives Gauge factor of a strain gauge ? (A) L / R L R (B) R / L R L (C) R / D R D (D) R / R
MCQ 143

Which one of the following definition correctly represents a data acquisition system (DAS) ? (A) DAS is a group of electronic devices that are connected to perform the measurement and quantization of electrical signals for digital processing (B) DAS is a group of devices that are connected to store different signals (C) DAS is a system to control a process (D) DAS is a signal conditioner
MCQ 144

Match List I (Transducer) with List II and select the correct answer using the codes given below :
Page 42

www.gatehelp.com List I A. B. C. Piezo-electric crystal Manometer Resistance bridge 1. 2. 3. 4. List II Static pressure measurement Dynamic force measurement Study of vibration of a cantilever Vibration in position of slider by an external force changes the resistance.

IES EE Topic wise 2001-2008 Measurement & Instrumentation

D. Resistance strain gauge

Codes : A (A) (B) (C) (D) 4 4 2 2 B 1 3 1 3 C 2 2 4 4 D 3 1 3 1

MCQ 145

Which one of the following thermocouples has the highest temperature measuring range ? (A) Copper-Constantan (B) Iron-Constantan (C) Alumel-Chromel (D) Platinum Rhodium-Platinum
MCQ 146

Consider the following elements : 1. Low pass filter 2. 3. 4. 5. Signal transmission medium Amplifier Digital to analog convertor Analog to digital convertor

Which one of the following sequences is the correct sequence for effective signal reconstruction in a data acquisition and processing scheme ? (A) 1-3-5-2-4
Page 43

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (B) 3-1-5-2-4 (C) 1-5-3-2-4 (D) 3-5-1-4-2 Directions : The following 4 (four) items consist of two statements : one labelled as the Assertion (A) and the other as Reason (R). You are to examine these two statements carefully and select the answers to these items using the codes given below : (A) Both A and R are individually true and R is the correct explanation of A (B) Both A and R are individually true but R is NOT the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 147

Assertion (A) : An electronic voltmeter measures the voltage across a high resistance more accurately as compared to an ordinary multimeter Reason (R) : The electronic voltmeter consists of a voltage amplifier which is not present in an ordinary multimeter.
MCQ 148

Assertion (A) : Cathode ray oscilloscopes using CRT employing electrostatic deflection are used in laboratories for scientific measurements. Reason (R) : CRT using electrostatic deflection systems have more deflection sensitivity as compared to CRT employing magnetic deflecting system.
MCQ 149

Assertion (A) : A dual trace CRO can display two input signals simultaneously Reason (R) : A dual trace CRO uses a CRT having two electron guns to generate two electron beams simultaneously.
MCQ 150
Page 44

www.gatehelp.com Assertion (A) : Data acquisition systems are used in a large and ever increasing number of applications in a variety of industrial and scientific areas. Reason (R) : Transducer converts the analog signals to a form acceptable by the A/D convertor.
YEAR 2003 MCQ 151

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Directions : The following 3 (three) items consist of two statements, one labelled as Assertion A and the other labelled as Reason R. You are to examine these two statements carefully and select the answers to these items using the codes given below : (A) Both A and R are individually true and R is the correct explanation of A (B) Both A and R are individually true but R is NOT the correct explanation of A (C) A is true but R is false (D) A is false but R is true.
MCQ 152

Assertion (A) : A Schering Bridge used for testing of a porcelain insulator is shielded by a metallic screen. Reason (R) : Earths magnetic magnetic field is blocked by a metallic screen.
MCQ 153

Assertion (A) : Multiplexing of signals is invariably used in telemetery systems. Reason (R) : Multiplexing improves signal to noise ratio over the communication channel and at destination.
MCQ 154

Assertion (A) : Magnetic tape is not used for digital data recording directly. Reason (R) : Digital data require high speed recording.
Page 45

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com
MCQ 155

Torque/Weight ratio of an instrument indicates (A) Selectivity (B) Accuracy (C) Fidelity (D) Sensitivity
MCQ 156

Which of the following are data representation elements in a generalized measurement system ? 1 2 3 4 Analog indicator Amplifier A/D converter Digital display

Select the correct answer using the codes given below : (A) 1 and 2 (B) 1 and 4 (C) 2 and 4 (D) 3 and 4
MCQ 157

A first order instrument is characterized by (A) Time constant only (B) Static sensitivity and time constant (C) Static sensitivity and damping coefficient (D) Static sensitivity, damping coefficient and natural frequency of oscillations
MCQ 158

Wire-wound resistors are unsuitable for use at high frequencies because (A) They are likely to melt under excessive eddy current (B) They exhibit unwanted inductive and capacitive effects (C) They create more electrical noise
Page 46

www.gatehelp.com (D) They consume more power


MCQ 159

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Decibel scale is useful while measuring voltages covering (A) Wide frequency ratio (B) Wide voltage ratio (C) Narrow frequency range (D) Narrow voltage range
MCQ 160

A standard resistances is made Bifilar type to eliminate (A) Stray capacitance (B) Temperature effect (C) Inductive effect (D) Skin effect
MCQ 161

Standard cell (A) Will have precise and accurate constant voltage when current drawn from it is few microamperes only (B) Will have precise and accurate constant voltage when few milliamperes are drawn from it (C) Will continue to have constant voltage irrespective of loading conditions (D) Can supply voltages up to 10 V
MCQ 162

For time and frequency, the working standard is (A) Microwave oscillator (B) Crystal controlled oscillator (C) Laser (D) ARF oscillator
MCQ 163

A C.R.O is operated with X and Y settings of 0.5 ms/cm and 100


Page 47

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com mV/cm. The screen of the C.R.O is 10 cm # 8 cm (X and Y.) A sine wave of frequency 200 Hz and r.m.s amplitude of 300 mV is applied to the Y-input. The screen will show (A) One cycle of the undistorted sine wave (B) Two cycles of the undistorted sine wave (C) One cycle of the sine wave with clipped amplitude (D) Two cycles of the sine wave with clipped amplitude
MCQ 164

The difference between the indicated value and the true value of a quantity is (A) Gross error (B) Absolute error (C) Dynamic error (D) Relative error
MCQ 165

Vibration galvanometers, tuneable amplifiers and head phones are used in (A) d.c. bridges (B) a.c. bridges (C) Both d.c. and a.c. bridges (D) kelvin double bridge
MCQ 166

A Wien-bridge is used to measure the frequency of the input signal. However, the input signal has 10% third harmonic distortion. Specifically the signal is 2 sin 400t + 0.2 sin 1200t (with t in sec.). With this input the balance will (A) Lead to a null indication and setting will correspond to a frequency of 200 Hz (B) Lead to a null indication and setting will correspond to 260 Hz. (C) Lead to a null indication and setting will correspond to 400 Hz. (D) Not lead to null indication.
Page 48

www.gatehelp.com
MCQ 167

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which one of the following multi-range voltmeters has high and constant input impedance ? (A) Permanent magnet moving coil voltmeter (B) Electronic voltmeter (C) Moving iron voltmeter (D) Dynamometer type voltmeter
MCQ 168

In a Q-meter measurement to determine the self-capacitance of a coil, the first resonance occurred at f 1 with C1 = 300 pF . The second resonance occurred at f 2 = 2f 1 with C 2 = 60 pF . The self-capacitance of coil works out to be (A) 240 pF (B) 60 pF (C) 360 pF (D) 20 pF
MCQ 169

A multimeter is used for the measurement of the following 1. Both a.c. and d.c. voltage 2. 3. 4. 5. Both a.c. & d.c. current Resistance Frequency Power

Select the correct answer using the codes given below : (A) 1, 2 and 4 (B) 1, 2 and 5 (C) 1, 3 and 5 (D) 1, 2 and 3
MCQ 170

Which one of the following truly represents the output on the screen of spectrum analyzer when an amplitude modulated wave is connected to it ?
Page 49

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (A) Single vertical line on the screen (B) Two vertical lines on the screen (C) Three vertical lines with amplitude (D) Three vertical lines out of which two have equal magnitude
MCQ 171

Three d.c. voltmeters are connected in series across a 120 V d.c. supply. The voltmeter are specified as follows : Voltmeter A : 100 V, 5 mA Voltmeter B : 100 V, 250 ohms/V Voltmeter C : 10 mA, 15,000 ohms The voltages read by the meters, A, B and C are respectively (A) 40, 50 and 30 V (B) 40, 40 and 40 V (C) 60, 30 and 30 V (D) 30, 60 and 30 V
MCQ 172

The capacitance and loss angle of a given capacitor specimen are best measured by (A) Wheatstone bridge (B) Maxwell bridge (C) Anderson bridge (D) Schering bridge
MCQ 173

The energy capacity of a storage battery is rated in (A) kwh (B) kw (C) Ampere hours (D) Joules
MCQ 174

The pressure coil of an induction type energy meter is


Page 50

www.gatehelp.com (A) Highly resistive (B) Highly inductive (C) Purely resistive (D) Purely inductive
MCQ 175

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Match List I (Parameter) with List II (Transducer) and select the correct answer : List I A. B. C. Pressure Temperature Displacement 1. 2. 3. 4. 5. Codes : A (A) (B) (C) (D) 1 2 1 2 B 2 1 2 1 C 5 4 5 3 D 3 3 4 4 List II Thermistor Piezoelectric crystal Capacitance transducer Resistance strain gauge Ultrasonic waves

D. Stress

MCQ 176

Measurement of flow, thermal conductivity and liquid level using thermistors make use of (A) Resistance decrease with temperature (B) Resistance increase with temperature (C) Self-heating phenomenon (D) Change of resistivity
MCQ 177

Pair of active transducers is (A) Thermistor, Solar cell (B) Thermocouple, Thermistor
Page 51

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (C) Thermocouple, Solar cell (D) Solar cell, LVDT


MCQ 178

Sensitivity of LVDT is mainly due to (A) Magnetic shielding of the core (B) Permeability of the core (C) Exact cancellation of secondary voltages (D) Insulation used in the winding
MCQ 179

A strain gauge with a resistance of 250 ohms undergoes of 0.150 ohm during a test. The strain is 1.5 # 104 . Then the gauge factor is (A) 2.0 (B) 3.0 (C) 4.0 (D) 100
MCQ 180

Integrating principle in the digital measurement is the conversion of (A) Voltage to time (B) Voltage to frequency (C) Voltage to current (D) Current to voltage
MCQ 181

The correct sequence of the blocks is an analog data acquisition unit starting from the input is (A) Transducer-Recorder-Signal Conditioner (B) Transducer-Signal Conditioner-Recorder (C) Signal Conditioner-Transducer-Recorder (D) Signal Conditioner-Recorder-Transducer

YEAR 2002
Page 52

www.gatehelp.com
MCQ 182

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Consider the following statements about the D Arsonval Movement : 1. It is best suited for d.c. current measurement 2. 3. 4. It responds to the average value of current It measures the r.m.s value of a.c. currents It could be used for power measurements

Which of these statements is/are correct ? (A) Only 1 (B) 1 and 2 (C) 2 and 3 (D) 1, 2, 3 and 4
MCQ 183

Two meters X and Y require 40 mA and 50 mA, respectively, to give full-scale deflection, then (A) sensitivity can not be judged with given information (B) both are equally sensitive (C) X is more sensitive (D) Y is more sensitive
MCQ 184

What is the correct sequence of the following types of ammeters and voltmeters with increasing accuracy ? 1. Moving iron 2. 3. Moving-coil permanent magnet Induction

Select the correct answer using the codes given below : (A) 1, 3, 2 (B) 1, 2, 3 (C) 3, 1, 2 (D) 2, 1, 3
MCQ 185

The total current I = I1 + I2 in a circuit is measured as I1 = 150 ! 1 A


Page 53

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com , I2 = 250 ! 2 A , where the limits of error are given as standard deviations. I is measured as (A) (400 ! 3) A (B) (400 ! 2.24) A (C) (400 ! 1/5) A (D) (400 ! 1) A
MCQ 186

Match List I with List II and select the correct answer : List I(Device/network) A. B. C. Twin-T network 1. List II(Application) For use in accurate a.c. bridge For realising amplifier frequency

Shielded decade capacitance 2. box selective Wagner earthing arrangement 3.

To match impedance and block d.c. noise in a.c. bridge For minimissing earth capacitance leakage

D. Inter bridge transformer Codes : A (A) (B) (C) (D) 2 3 2 3 B 1 4 4 1 C 4 1 1 4 D 3 2 3 2

4.

MCQ 187

For the bridge shown in the given figure,

Page 54

www.gatehelp.com at balance the values of Rx , Cx and Qx will be (A) Rx = C1 R2 /C 3 Cx = R1 C 3 /R2 Q x = C 1 R 1 (B) Rx = C1 R2 /C 3 Cx = R1 C 3 /R2 Qx = 1/C1 R1 Rx = C1 R1 /C 3 (C) Cx = R2 C 3 /R1 Qx = 1/C1 R1 (D) Rx = C1 R1 /C 3 Cx = R2 C 3 /R1 Q x = C 1 R 1
MCQ 188

IES EE Topic wise 2001-2008 Measurement & Instrumentation

The reflecting mirror mounted on the moving coil of a vibration galvanometer is replaced by a bigger size mirror. This will result in (A) lower frequency of resonance & lower amplitude of vibration (B) lower frequency of resonance but the amplitude of vibration is unchanged (C) higher frequency of resonance & lower amplitude of vibration (D) higher frequency of resonance but the amplitude of vibration is unchanged
MCQ 189

Consider the following statements associated with moving iron instruments : 1. 2. 3. These can be used in d.c. as well a.c. circuits The scale is non-uniform The moving iron is placed in a field of a permanent magnet.

Which of these statements are correct ? (A) 1, 2 and 3 (B) 1 and 2


Page 55

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (C) 2 and 3 (D) 1 and 3


MCQ 190

A screen pattern oscillogram, shown in the given figure is obtained when a sine-wave signal of unknown frequency is connected to the vertical input terminals, and at the same time, a 600 Hz sinewave voltage is connected to the horizontal input terminals of an oscilloscope.

What is the value of unknown frequency ? (A) 300 Hz (B) 400 Hz (C) 600 Hz (D) 900 Hz
MCQ 191

Which of the following statements is not correct for a storage type oscilloscope ? (A) The storage target is a conductive mesh covered area with magnesium fluoride (B) Secondary emission electrons etch a positively charged pattern (C) The flood guns used for display, emit high velocity electrons (D) The flood guns are placed between the deflection plates and storage target.
MCQ 192

In an oscilloscope, two Lissajous figure (X) and (Y) are observed. This indicates that ratio of vertical input signal frequency to that of horizontal input frequency are
Page 56

www.gatehelp.com

IES EE Topic wise 2001-2008 Measurement & Instrumentation

(A) 5/3 for X and 3/2 for Y (B) 3/2 for X and 5/3 for Y (C) 5/3 for X and 5/3 for Y (D) 3/2 for X and 3/2 for Y
MCQ 193

A spring controlled moving iron voltmeter draws a current of 1 mA for full scale value of 100 V. If it draws a current of 0.5 mA, the meter reading is (A) 25 V (B) 50 V (C) 100 V (D) 200 V
MCQ 194

In the measurement of power on balanced load by two Wattmeter method in a 3-phase circuit, the readings of the Wattmeters are 3 kW and 1 kW respectively, the latter being obtained after reversing the connections to the current coil. The power factor of the load is (A) 0.277 (B) 0.554 (C) 0.625 (D) 0.866
MCQ 195

Two types of connections of Wattmeter pressure coil are shown in the figures
Page 57

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com

The value of the Wattmeter current coil resistance r , which makes the connection errors the same in the two cases is (A) 0.05 (B) 0.1 (C) 0.01 (D) 0.125
MCQ 196

In calibration of a dynamometer Wattmeter by potentiometer, phantom loading arrangement is used because ammeter, phantom loading arrangement is used because (A) the arrangement gives accurate results (B) the power consumed in calibration work is minimum (C) the method gives quick results (D) the onsite calibration is possible
MCQ 197

The accuracy of Kelvins double bridge for the measurement of low resistance is high because the bridge (A) uses two pairs of resistance arms (B) has medium value resistance in the ratio arms (C) uses a low resistance link between standard and test resistances (D) uses a null indicating galvanometer
MCQ 198

An imperfect capacitor is represented by a capacitance C in parallel with a resistance R . The value of its dissipation factor tan is (A) CR (B) 2 CR (C) 1/ 2 CR
Page 58

www.gatehelp.com (D) 1/CR


MCQ 199

IES EE Topic wise 2001-2008 Measurement & Instrumentation

An energy-meter having a meter constant of 1200 rev per kWH is found to make 5 revolutions in 75 s. The load power is (A) 500 W (B) 100 W (C) 200 W (D) 1000 W
MCQ 200

Which one of the following statements is not true ? (A) Potentiometric linear displacement can give high output signal (B) Linear variable differential transformer has low output impedance (C) Synchros and resolvers have low accuracy (D) Eddy current proximity transducers are non-contact type transducers
MCQ 201

Match List I (Transducer) with List II (Range of temperature) and select the correct answer : List I A. B. C. Mercury in glass 1. thermometer Platinum resistance 2. thermometer Thermocouple with 3. lead compensation List II Can be used upto 300c C in normal conditions Can be used upto 900c C with sufficient accuracy Can be used upto 1400c C Can be used for temperatures upto several thousand degrees.

D. Optical radiation 4. pyrometer Codes : A (A) (B) 3 1 B 2 4 C 1 3 D 4 2

Page 59

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (C) (D) 3 1 4 2 1 3 2 4

MCQ 202

Match List I (Instrument) with List II (Measured) and select the correct answer : List I A. B. C. McLeod gauge Turbine meter Pyrometer 1. 2. 3. 4. List II Temperature Pressure Flow Displacement

D. Synchros Codes : A (A) (B) (C) (D) 1 2 1 2 B 4 3 3 4 C 2 1 2 1 D 3 4 4 3

MCQ 203

In a stroboscopic method of rotational speed measurement of a machine shaft, N = the machine shaft speed of rotation of the shaft in revolutions/ min n = No. of points on the circuit pattern F = No. of flash per min. The speed of rotation N will be (A) N = F + n (B) N = F n (C) N = F/n (D) N = F.n
MCQ 204
Page 60

www.gatehelp.com To reduce the effect of noise level, 100 sets of data are averaged. The averaged data set will have a noise level reduced by a factor of (A) 10 (B) 10 2 (C) 50 2 (D) 100
MCQ 205

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which of the following transducers is classified as an active transducer ? (A) Metallic strain gauge (B) Capacitive microphone (C) LVDT (D) Piezoelectric transducer
MCQ 206

Which curve in the given figure represents resistance temperature characteristics of a thermistor ? (A) Curve A (B) Curve B (C) Curve C (D) Curve D
MCQ 207

A 1 cm piezoelectric transducer having a g-coefficient of 58 V/kg/m2 is subjected to a constant pressure of 103 kg/m2 for about 15 minutes. The Piezo voltage developed by the transducer will be (A) 116 mV (B) 58 mV
Page 61

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (C) 29 mV (D) 0 mV


MCQ 208

If K is the number of parity bits provided with a message, the number of errors which can be detected are (A) K (B) K 1 (C) K + 1 (D) dependent upon the number of bits in the message also. Directions : The following 3 (three) items consist of two statements, one labelled as Assertion A and the other labelled as Reason R . You are to examine these two statements carefully and decide if the Assertion A and the Reason R are individually true and if so, whether the Reason is a correct explanation of the Assertion. Select your answers to these items using the codes given below and mark your answer sheet accordingly. (A) Both A & R are true but R is the correct explanation of A. (B) Both A and R are true and R is NOT the correct explanation of A (C) A is true but R is false (D) A is false but R is true
MCQ 209

Assertion (A) : A full-wave rectifier type a.c. voltmeter reads the true rms value of the input wave-form. Reason (R): The full wave rectifier type a.c. voltmeter has a rectifier unit first which feeds its output to the PMMC indicative instrument.
MCQ 210

Assertion (A) : A four-arm Wien bridge network is sometimes used in feedback circuit of tuned amplifier. Reason (R): The balance equation of such a Wien bridge contains frequency term along with arm parameters.
MCQ 211
Page 62

www.gatehelp.com Assertion (A) : A spectrum analyzer displays the frequency spectrum of a signal on the CRT screen. Reason (R) : It uses a sweep voltage generator to sweep the electron beam as well as the input signal.

IES EE Topic wise 2001-2008 Measurement & Instrumentation

YEAR 2001 MCQ 212

Digital data acquisition system are used 1. 2. 3. 4. Only when the output of the transducers is in digital form When physical process being monitored is slowly varying (narrow bandwidth) When low accuracy can be tolerated When high accuracy and low per channel cost is required

Which of these statements are correct ? (A) 1, 2 and 3 (B) 1, 3 and 4 (C) 1 and 3 (D) 2 and 4
MCQ 213

Match List I with List II and select the correct answer : List I A. B. C. Precision Accuracy Resolution 1. 2. 3. 4. List II The smallest change in the input quantity which can be detected with its certainty Closeness of the reading with its true value Measure of reproductibility measurements of the

D. Static

Ratio of infinitesimal change sensitivity in output to infinitesimal change in input

MCQ 214

The modern standard of time is (A) a second defined as 1/86, 400 of a mean solar day
Page 63

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (B) a second defined as time constant of an R -C series circuit having R = 2 M, C = 500 pF (C) A second which is duration of 9192631770 periods of radiation corresponding to the transition between the two hyperfine levels of the fundamental state of the atom cesium 133. (D) A second defined as 1/31556925.9747 of the time required by the earth to orbit the sum in the year 1900.
MCQ 215

Match List I (Error parameters) with List II (Values) and select the correct answer : ( is the standard deviation of Gaussian error): List I A. B. C. Precision index Probable error Error limit 1. 2. 3. List II 0.67 3 0.39/ 0.71/

D. Peak probability density of 4. error Codes : A (A) (B) (C) (D) 4 4 3 3 B 2 1 1 2 C 1 2 2 1 D 3 3 4 4

MCQ 216

Match List I (Bridge) with List II (Parameter to be measured) and select the correct answer : List I A. B. C. Maxwells bridge Hays bridge Schering bridge 1. 2. 3. 4. List II Frequency Inductance of medium Q-coils ^1 < Q < 10h Inductance of high Q-coils (Q>10) Capacitance

D. Wine bridge Codes :


Page 64

www.gatehelp.com A (A) (B) (C) (D) 4 4 2 2 B 3 1 1 3 C 2 2 4 4 D 1 3 3 1

IES EE Topic wise 2001-2008 Measurement & Instrumentation

MCQ 217

Which of the following are the characteristics of a thermocouple type of indicating instrument ? 1. 2. 3. 4. Its accuracy is very high, as high as about 1 percent. It has linear scale because a D Arsonval movement is used for measuring the output. It is an RF instrument and can be used for frequency up to about 50 MHz. It cannot be damaged by overloads.

(A) 1 and 2 (B) 2 and 3 (C) 3 and 4 (D) 1 and 3

MCQ 218

Consider the following equations which can be derived from the ac bridges shown in the fig. I and fig. II by assuming L/L = 0.1 and R = L : 1. Vo1 = Vo2 2. Vo1 = 0.05Vs 3. Vo1 = 0.1Vs 4. Vo2 = 0.05Vs 5. Vo2 = 0.1Vs
Page 65

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com

The correct derived equations from these figures of ac bridges are (A) 1, 2 and 4 (B) 2, 4 and 5 (C) 2 and 5 (D) 1, 3 and 5
MCQ 219

Which one of the following statements correctly represents the post acceleration in a Cathode-Ray Tube ? (A) It provides deflection of the beam (B) It increases the brightness of the trace if the signal frequency is higher than 10 MHz (C) It accelerates the beam before deflection (D) It increases the brightness of the trace of low frequency signal
MCQ 220

If the Q-factor of a coil is measured by varying the frequency, then (A) The plot between Q and frequency is linear (B) The value of Q initially decreases with increase of frequency and afterwards it will increase with increase of frequency. (C) The value of Q initially increases with increase of frequency and afterwards it will decrease with increase of frequency (D) The Q-factor remains constant irrespective of value of frequency
MCQ 221

Consider the following statements : The value of earth resistance depends upon
Page 66

www.gatehelp.com 1. 2. 3. 4. shape of electrode depth to which the electrode is driven into earth specific resistance of soil material of electrode

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Which of the following statements is correct ? (A) 1, 2, 3 and 4 (B) 2, 3 and 4 (C) 1 and 2 (D) 1, 3 and 4
MCQ 222

Which of the following electronic instruments (or equipment) can be used to measure correctly the fundamental frequency component of a waveform and its higher harmonics ? 1. Cathode ray oscilloscope 2. 3. 4. Vacuum tube voltmeter Spectrum analyzer Distortion factor meter

Select the correct answer using the codes given below : (A) 1 and 2 (B) 2 and 3 (C) 3 and 4 (D) 1 and 4
MCQ 223

In a single-phase power factor meter, the controlling torque is (A) provided by spring control (B) provided by gravity control (C) provided by stiffness of suspension (D) not required
MCQ 224

Which one of the following transducers can be used for measurement of pressures as high as 100,000 atmosphere ?
Page 67

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (A) Mcleod gauge (B) Pirani gauge (C) Bridgman gauge (D) Knudsen gauge
MCQ 225

A dc circuit can be represented by an internal voltage source of 50 V with an output resistance of 100 k . In order to achieve accuracy better than 99% for voltage measurement across its terminals, the voltage measuring device should have a resistance of at least (A) 10 M (B) 1 M (C) 10 k (D) 1 k
MCQ 226

In electrodynamometer type wattmeters, the inductance of pressure coil produces error. The error is (A) constant irrespective of the power factor of the load (B) higher at higher power factor loads (C) higher at lower power factor loads (D) higher at unity power factor loads
MCQ 227

An analogue voltage signal whose highest significant frequency is 1 kHz is to be coded with a resolution of 0.01 percent for a voltage range of 0-10 V. The minimum sampling frequency and the minimum number of bits should respectively be (A) 1 kHz and 12 (B) 1 kHz and 14 (C) 2 kHz and 12 (D) 2 kHz and 14
MCQ 228

An ac voltmeter using full-wave rectification and having a sinusoidal


Page 68

www.gatehelp.com input has an ac sensitivity equal to (A) 1.414 times dc sensitivity (B) dc sensitivity (C) 0.90 times dc sensitivity (D) 0.707 times dc sensitivity
MCQ 229

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Consider the following statements in connection with measurement of temperature : 1. A thermistor is highly sensitive as compared with platinum resistance thermometer. 2. 3. 4. The resistance of a thermistor is solely a function of its absolute temperature whether source of heat is external, internal or both. A thermistor has linear resistance temperature characteristics. Most thermistors exhibit negative resistance temperature coefficient.

Which of these statements are correct ? (A) 1, 2 and 3 (B) 1, 2 and 4 (C) 2, 3 and 4 (D) 1, 3 and 4
MCQ 230

Time division multiplexing is used when the data to be transmitted is (A) slow changing (B) of small bandwidth (C) slow changing and has a small bandwidth (D) fast changing and has a wide bandwidth
MCQ 231

If an induction type energy meter runs fast, it can be slowed down by (A) lag adjustment (B) light load adjustment (C) adjusting the position of braking magnet and moving it closer from the centre of the disc
Page 69

IES EE Topic wise 2001-2008 Measurement & Instrumentation

www.gatehelp.com (D) adjusting the position of braking magnet and moving it away from the centre of the disc
MCQ 232

The circuit generally used in digital instruments to convert sine waves into rectangular pulses is a (A) sawtooth generator (B) differential amplifier (C) sample and hold circuit (D) Schmitt trigger
MCQ 233

Spectrum analyser is a combination of (A) narrow hand superheterodyne receiver and CRO (B) signal generator and CRO (C) oscillator and wave analyser (D) VTVM and CRO Directions : The following 3 (three) items consist of two statements, one labelled as Assertion A and the other labelled as Reason R. You are to examine these two statements carefully and decide if the Assertion A and the Reason R are individually true and if so, whether the Reason is a correct explanation of the Assertion. Select your answers to these items using the codes given below and mark your answer sheet accordingly. (A) Both A and R are true but R is the correct explanation of A (B) Both A and R are true but R is NOT the correct explanation of A (C) A is true but R is false (D) A is false but R is true.
MCQ 234

Assertion (A) : A resistance potentiometers used for measurement of displacement, sensitivity and linearity are conflicting requirements. Reason (R) : The voltmeter used for measurement of output voltage of the potentiometer has a finite resistance which causes loading
Page 70

www.gatehelp.com effects.
MCQ 235

IES EE Topic wise 2001-2008 Measurement & Instrumentation

Assertion (A) : In good quality magnetic cassette tape recorders, ac bias is provided to recording head for better recording and reproduction. Reason (R) : The use of ac bias avoids the non linear characteristic of the BH curve of the recording head.
MCQ 236

Assertion (A) : In digital transducers used for measurement of displacement, it is quite common to use Gray Code instead of natural binary code. Reason (R) : Gray Code is used for overcoming the inherent disadvantages of a natural binary code. These include errors that are caused on account of even slight misalignment which may cause change of decimal number thereby changing the number of bits. Gray Code does not suffer from this disadvantage.

*********

Page 71