0% found this document useful (0 votes)
151 views6 pages

Ebf CBC

This document provides design details for an eccentrically braced frame link and brace. The link, a W18x143 section, was checked for various limit states including local buckling, shear, flexure, and combined loading capacities. The design was found to be adequate with 3/4" stiffeners required. The brace, an HSS10x10x5/8" tube, was also checked against limit states such as local buckling, compression, and connection design. A 5/8" gusset plate with 5/16" fillet welds was specified to connect the brace. Both the link and brace designs satisfied all code requirements.

Uploaded by

Nikki Roberts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views6 pages

Ebf CBC

This document provides design details for an eccentrically braced frame link and brace. The link, a W18x143 section, was checked for various limit states including local buckling, shear, flexure, and combined loading capacities. The design was found to be adequate with 3/4" stiffeners required. The brace, an HSS10x10x5/8" tube, was also checked against limit states such as local buckling, compression, and connection design. A 5/8" gusset plate with 5/16" fillet welds was specified to connect the brace. Both the link and brace designs satisfied all code requirements.

Uploaded by

Nikki Roberts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA & DESIGN SUMMARY
LINK SECTION = > W18X143 = > A d t
w
b
f
t
f
S
x
MAX SERVICE LOADS AT LINK END V
DL
= 1.8 kips 42.1 19.5 0.73 11.20 1.32 282
P
DL
= 7.4 kips I
x
r
x
r
y
Z
x
k
M
DL
= 14.4 ft-kips 2750 8.08 2.72 322 1.72
V
LL
= 1.3 kips
P
LL
= 5.3 kips THE LINK DESIGN IS ADEQUATE.
M
LL
= 9.6 ft-kips ( USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE
MAX HORIZ. SEISMIC LOADS AT LINK END V
E
= 84 kips (ASCE 7-05, 12.4.2.1) & END STIFFENERS WITH 5/16" FILLET WELD.)
P
E
= 5.5 kips
M
E
= 168 ft-kips
LINK LENGTH e = 4 ft
LINK YIELD STRESS F
y
= 50 ksi
REDUNDANCY FACTOR r = 1.19
SEISMIC PARAMETER S
DS
= 1 (ASCE 7-05, 11.4.4)
BEAM LENGTH BETWEEN COL. CENTERS L = 30 ft (including link)
STORY HEIGHT h = 12.5 ft
MAXIMUM INELASTIC STORY DRIFT d = 0.7 in (ASCE 7-05, 12.8.6)
DETERMINE FACTORED DESIGN LOADS AT LINK END (CBC 07 1605.2 & ASCE 7-05 12.4.2.3)
V
u
= (1.2 + 0.2S
DS
)V
DL
+ f
1
V
LL
+ rV
E
= 103.13 kips
P
u
= (1.2 + 0.2S
DS
)P
DL
+ f
1
P
LL
+ rP
E
= 19.56 kips
M
u
= (1.2 + 0.2S
DS
)M
DL
+ f
1
M
LL
+ rM
E
= 224.88 ft-kips
Where f
1
= 0.5
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
b
f
/ (2t
f
) = 4.24 < 0.3 (E
s
/ F
y
)
0.5
= 7.22 [Satisfactory]
[ 52 / (F
y
)
0.5
for AISC Seismic 97, Tab. I-9-1]
Where E
s
= 29000 ksi
3.14(E
s
/F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) = 74.42 , for P
u
/f
b
P
y
< 0.125
[ 520 / (F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) for AISC Seismic 97, Tab. I-9-1]
N/A , for P
u
/f
b
P
y
> 0.125
{ MAX[ 191 / (F
y
)
0.5
(2.33-P
u
/f
b
P
y
) , 253 / (F
y
)
0.5
] for AISC Seismic 97, Tab. I-9-1}
[Satisfactory] Where f
b
= 0.9 , P
y
= F
y
A = 2105 kips
CHECK SHEAR CAPACITY (AISC 341-05, Sec. 15.2b)
fV
n
= f MIN(V
p
, 2M
p
/e) = 332.3 kips > V
u
[Satisfactory]
Where f = 0.9 (Ignored axial force effect since Pu < 0.15 Py = 0.15 Fy Ag, AISC 341-05, 15.2)
A
w
= (d - 2t
f
)t
w
= 12.31
in
2
V
p
= 0.6F
y
A
w
= 369.2 kips
M
p
= F
y
Z

= 1341.7 ft-kips
CHECK FLEXURAL CAPACITY (AISC 360-05 F1)
f
b
M
p
= 1207.5 > M
u
[Satisfactory]
Where f
b
= 0.9
CHECK ADDITIONAL SHEAR CAPACITY REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b) < = DOES NOT APPLY.
fV
na
= f MIN(V
pa
, 2M
pa
/e) = 332.3 kips > V
u
[Satisfactory]
Where f = 0.9
V
pa
= V
p
[1 - (P
u
/P
y
)
2
]
0.5
= 369.2 kips
M
pa
= 1.18 M
p
(1 - P
u
/P
y
) = 1568.5 ft-kips
CHECK ADDITIONAL LINK LENGTH REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b) < = DOES NOT APPLY.
[1.15 - 0.5r' (A
w
/A
g
)](1.6M
p
/V
p
) = N/A ft, for r' (A
w
/A
g
) > 0.3
(1.6M
p
/V
p
) = 5.81 ft, for r' (A
w
/A
g
) < 0.3
[Satisfactory] Where r' = P
u
/ V
u
= 0.19
A
w
/ A
g
= 0.29
22.00 <


e <
{
h / t
w
=
(E
s
/F
y
)
0.5
MAX[1.49, 1.12(2.33 - C
a
)] =
Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
(cont'd)
CHECK LINK ROTATION ANGLE LIMITATION (AISC 341-05, 15.2c)
g
p
= L d / (h e) = 0.04 rad < g
p,allowable
= 0.080 rad [Satisfactory]
Where g
p,allowable
== 0.08 rad for e < 1.6M
p
/V
p
;
= 0.02 rad for e > 2.6M
p
/V
p
;
= linear interpolation [0.02, 0.08] by e value.
1.6M
p
/V
p
= 5.81 ft, 2.6M
p
/V
p
= 9.45 ft
CHECK LINK STIFFENER REQUIREMENT (AISC 341-05, 15.3)
b
st
= (b
f
- 2t
w
) /2 = 4.87 in
t
st
= MAX (0.75 t
w
, 3/8 ) = 0.548 in
USE 9/16 x 4-7/8 END STIFFENERS AT EACH SIDE.
s = see table following = 30.0 in
Provide 1 stiffeners to give s = 24.0 in
Where 1.6 M
p
/ V
p
= 5.81 ft
2.6 M
p
/ V
p
= 9.45 ft
5.0 M
p
/ V
p
= 18.17 ft
g
p
= 0.04 rad
e = 4 ft
d = 19.5 in
t
st
= MAX (t
w
, 3/8 ) = 0.730 in
USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE
STIFFENERS AT EACH SIDE.
g
p
e [0 ~ 0.02] (0.02 ~ 0.08) 0.08
[0~1.6M
p
/V
p
] 52t
w
-d/5 178t
w
/3-d/5-1100g
p
t
w
/3 30t
w
-d/5
(1.6M
p
/V
p
~2.6M
p
/V
p
] MIN(52t
w
-d/5 , b
f
) Min(178t
w
/3-d/5-1100g
p
t
w
/3 , 1.5b
f
) MIN(30t
w
-d/5 , 1.5b
f
)
(2.6M
p
/V
p
~5M
p
/V
p
) 1.5b
f
1.5b
f
1.5b
f
[5.0M
p
/V
p
~Greater] Not ReqD Not ReqD Not ReqD
The best fillet weld size (AISC 360-05 Sec.J2.2b)
> w
MIN
= 0.1875 in
< w
MAX
= 0.4375 in
[Satisfactory]
The required weld length between A36 stiffener and web (AISC 360-05 Sec.J2.4)
L
w
= A
st
F
y
/ [(2) f F
w
(0.707 w)] = (9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] = 5.01 in
< (d - 2k), [Satisfactory]
The required weld length between A36 stiffener and flange (AISC 360-05 Sec.J2.4)
L
f
= 0.25A
st
F
y
/ [(2) f F
w
(0.707 w)] = 0.25(9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] = 1.25 in
< (b
st
- k), [Satisfactory]
CHECK COMBINED LINK CAPACITY (AISC 360-05 Sec.H.1)
f = P
u,link
/ (2A
f
) + M
u,link
/ Z
f
= 35.3 < F
y
[Satisfactory]
Where P
u,link
= W P
u
= 70.0 kips
M
u,link
= V
p
(e/2) = 738.5 ft-kips
Z
f
= (d - t
f
) b
f
t
f
= 268.8
in
3
W = V
n
/ V
u
= 3.58
A
f
= b
f
t
f
= 14.78
in
2
Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
w = 5/16 in
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA & DESIGN SUMMARY
BRACE SECTION (Tube or Pipe) = > HSS10X10X5/8 Tube A r
min
t h
MAX SERVICE LOADS P
DL
= 11.8 kips 21.00 3.80 0.58 10.00
P
LL
= 8.3 kips
UNBRACED LENGTH OF THE BRACE L
b
= 11 ft
(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA)
THE BRACE DESIGN IS ADEQUATE.
REQUIRED CONNECTION = > ( 5/8 in Gusset Plate with 23 in Length, 4 leg, 5/16 in Fillet Weld.)
DETERMINE LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
D / t = 0.044 E
s
/ F
y
= 27.74 , for Pipe
h / t = 1.12 (E
s
/ F
y
)
0.5
= 28.12 , for Tube
Where F
y
= 46 ksi
E
s
= 29000 ksi
DETERMINE FACTORED DESIGN LOADS (AISC 341-05 Sec.15.6)
P
u
= (1.2 + 0.2S
DS
)P
DL
+ f
1
P
LL
+ P
E
= 629.9 kips
Where P
E
= 1.25 R
y
[V
n
L L
b
/ (L-e) h] = 609.2 kips
R
y
= 1.3 (1.4 for Pipe.)
DETERMINE DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)
f
c
P
n
= f
c
A
g
F
cr
= 757.24 kips > P
u
[Satisfactory]
f
c
= 0.85
F
e
=
p
2
E / (KL / r)
2
=
237.8 ksi (0.658
(Fy/Fe)

)F
y
= 42.42 kis, for l
c
4.71
l
c
= (KL / r) (F
y
/ E)
0.5
= 1.38 0.877 F
e
= N/A kis, for l
c
> 4.71
K = 1.0
DETERMINE CONNECTION DESIGN FORCE
P
ut
= P
u
= 629.91 kips (Tension)
DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)
> w
MIN
= 0.1875 in
< w
MAX
= 0.4375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = P
ut
/ [(4) f F
w
(0.707 w)]
= 629.9 / [(4) 0.75 (0.6x70)(0.707x5/16)] = 22.63 in
( USE 23 in )
CHECK DESIGN SHEAR RUPTURE CAPACITY OF SLOTTED BRACE
(AISC 360-05 Sec.J4.2)
fR
n
= f(0.6F
u
)A
nu
= 1395.10 kips > P
ut
Where f = 0.75 [Satisfactory]
F
u
= 58 ksi (AISC 13th Tab.2-3)
A
nu
= 4 t L = 4 x 0.581 x 23 = 53.45
in
2
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
t
g
= 5/8 in
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 J4.2)
fR
n
= f(0.6F
u
)A
nv
= 750.38 kips > P
ut
[Satisfactory]
Where f = 0.75
F
u
= 58 ksi (plate value)
A
nv
= 2 tg L = 2 x 5/8 x 23 = 28.75
in
2
CHECK TENSION AT SLOTTED BRACE (AISC 360-05 D.2 b) THE GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)
f
t
P
n
= f
t
R
y
F
u
UA
n
= 1146.48 kips > P
ut
fR
n
= f(0.6F
u
)A
nv
+ fF
y
A
gt
= 750.38 + fF
y
A
gt
Where f
t
= 0.75 [Satisfactory] > P
ut
= 629.91
U = 1 (LRFD Sec.B3.2d) [Satisfactory]
A
n
= A - 2 t t
g
= 20.274
in
2
[Satisfactory]
w = 5/16 in
F
cr
= {
> Actual
Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05


PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA & DESIGN SUMMARY
MAX SERVICE LOADS AT OUTSIDE OF LINK V
DL
= 6.8 kips
P
DL
= 1 kips
M
DL
= 17 ft-kips
V
LL
= 4.8 kips
P
LL
= 0.7 kips
M
LL
= 11.3 ft-kips
SEISMIC LOADS AT OUTSIDE OF LINK V
E
= 8.7 kips (ASCE 7-05 12.4.2.1)
P
E
= 100 kips
M
E
= 100 ft-kips
(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA) THE BEAM DESIGN IS ADEQUATE.
DETERMINE FACTORED DESIGN LOADS AT SECTION OF LINK AND BEAM (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
V
u
= (1.2 + 0.2S
DS
)V
DL
+ f
1
V
LL
+ rV
E
= 67.0 kips
P
u
= (1.2 + 0.2S
DS
)P
DL
+ f
1
P
LL
+ P
E
= 537.9 kips
M
u
= (1.2 + 0.2S
DS
)M
DL
+ f
1
M
LL
+ M
E
= 923.0 ft-kips
Where f
1
= 0.5
R
y
= 1.1 (AISC 341-05 Tab. I-6-1)
V
n
= 369.2 kips (from link design)
M
n
= V
n
e / 2 = 738.47 ft-kips
V
E
= (1.1R
y
V
n
/ V
E , link
) V
E
= 46.3 kips
P
E
= 1.1R
y
V
n
L / 2h = 536.1 kips
M
E
= 1.1R
y
M
n
= 893.5 ft-kips
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
b
f
/ (2t
f
) = 4.24 < 0.3 (E
s
/ F
y
)
0.5
= 7.22 [Satisfactory]
[ 52 / (F
y
)
0.5
for AISC Seismic 97, Tab. I-9-1]
Where E
s
= 29000 ksi
3.14(E
s
/F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) = N/A , for P
u
/f
b
P
y
< 0.125
[ 520 / (F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) for AISC Seismic 97, Tab. I-9-1]
55.19 , for P
u
/f
b
P
y
> 0.125
{ MAX[ 191 / (F
y
)
0.5
(2.33-P
u
/f
b
P
y
) , 253 / (F
y
)
0.5
] for AISC Seismic 97, Tab. I-9-1}
[Satisfactory] Where f
b
= 0.9 , P
y
= F
y
A = 2105 kips
CHECK UNBALANCED SEGMENT LENGTH
L
1
= (L - e - d
c
) / 2 = 12.38 ft, (top & bottom flange bracing with a design strength greater than below will be provided
Brace Load : P
b,link
= 0.06R
y
F
y
b
f
t
f
= 48.8 kips, [AISC Seismic Sec.15.5] at each end of the link segment.)
L
2
= L
1
/ 2 = 6.19 ft, ( lateral supported at middle of beam outside of link with following design strength.)
Brace Load : P
b,mid
= 0.02F
y
b
f
t
f
= 14.8 kips, [AISC 341-05 Sec.15.6.(2)]
M
b, mid
=0.02F
y
b
f
t
f
d = 24.0 ft-kips, [AISC 341-05 Sec.15.6.(2)]
CHECK COMPRESSION CAPACITY (AISC 360-05 E3)
f
c
P
n
= f
c
F
cr
A

= 1694.11 kips > P
u
[Satisfactory]
Where f
c
= 0.85
K = 1.0
MAX(KL
1
/r
x
, KL
2
/r
y
) = 27.34 < 200 [Satisfactory]
l
c
= 0.361 p
F
cr
= 47.34 ksi


h / t
w
= 22.00 <
(E
s
/F
y
)
0.5
MAX[1.49, 1.12(2.33 - C
a
)] =
Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
(cont'd)
DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)
L
b
= 6.19 ft
L
p
= 1.76 r
y
(E / F
yf
)
0.5
= 9.60 ft
L
r
= r
y
X
1
[1 + (1 + X
2
F
L
2
)
0.5
]
0.5
/ F
L
= 35.27 ft
M
p
= MIN( F
y
Z
x
, 1.5 F
y
S
x
) = 1341.7 ft-kips
M
r
= F
L
S
x
= 940.0 ft-kips
M
cr
= C
b
S
x
r
y
X
1
(2 + X
1
2
X
2
r
y
2
/ L
b
2
)
0.5
/ L
b
= 17113 ft-kips
Where X
1
= p (0.5 E G J A)
0.5
/ S
x
= 4036.3 A I
y
t
f
r
y
S
x
X
2
= 4 C
w
[Sx / (G J)]
2
/ I
y
= 0.0006 42.1 311 1.32 2.72 282
F
r
= 10.00 ksi E G J C
w
Z
x
F
L
= MIN( F
yf
- F
r
, F
yw
) = 40.00 ksi 29000 11200 19.2 25700 322.0
C
b
= 1.30 , (AISC 360-05 F1)
M
p
= 1341.7 ft-kips, for L
b
@ [0 , L
p
]
M
n
= MIN{C
b
[M
p
- (M
p
- M
r
) (L
b
- L
p
) / (L
r
- L
p
)] , M
p
} = N/A ft-kips, for L
b
@ (L
p
, L
r
]
MIN(M
cr
, M
p
) = N/A ft-kips, for L
b
@ (L
r
, Larger)
f
b
M
n
= 0.9 M
n
= 1208 ft-kips
CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)
M
ux
= B
1
M
u
= 923.00 ft-kips < f
b
M
nx
= Min(R
y
f
b
F
y
Z, f
b
M
n
)

= 1208 ft-kips
Where P
e1
= p
2
E
s
I
x
/ (KL
x
)
2
= 35645 kips [Satisfactory]
C
m
= 0.6 (AISC 360-05 C2.1b) Where f
b
= 0.9
B
1
= C
m
/(1 - P
u
/P
e1
) = 1.000
CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)
For P
u
/f
c
P
n
>0.2, P
u
/ f
c
P
n
+ 8 / 9 (M
ux
/ f
b
M
nx
) = 1.00
For P
u
/f
c
P
n
<0.2, P
u
/ (2f
c
P
n)
+ M
ux
/ f
b
M
nx
= N/A
< 1 [Satisfactory]
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION = > W14X145 = > A d t
w
b
f
t
f
S
x
COLUMN AXIAL SERVICE LOADS P
DL
= 151 kips 42.7 14.8 0.68 15.50 1.09 232
P
LL
= 46 kips I
x
r
x
r
y
Z
x
k
NUMBER OF STORIES n = 4 1710 6.33 3.98 260 1.69
COLUMN YIELD STRESS (36 or 50) F
y
= 50 ksi
THE COLUMN DESIGN IS ADEQUATE.
UNBRACED COLUMN LENGTH L = h = 14 ft
DETERMINE COLUMN AXIAL SEISMIC LOAD (AISC 341-05 Sec. 15.8)
P
E
= (n - 1) 1.1 R
y
V
n
= 1340.3 kips
DETERMINE FACTORED DESIGN LOADS (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
P
u,t
= (0.9 - 0.2S
S
D ) P
DL
- P
E
= -1235 kips (Tension)
P
u,c
= (1.2 + 0.2S
DS
)P
DL
+ f
1
P
LL
+ P
E
= 1575 kips (Compression)
Where f
1
= 0.5 (CBC 1605.4)
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
b
f
/ (2t
f
) = 7.11 < 0.3 (E
s
/ F
y
)
0.5
= 7.22 [Satisfactory]
[ 52 / (F
y
)
0.5
for AISC Seismic 97, Tab. I-9-1]
Where E
s
= 29000 ksi
3.14(E
s
/F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) = N/A , for P
u
/f
b
P
y
< 0.125
[ 520 / (F
y
)
0.5
(1-1.54P
u
/f
b
P
y
) for AISC Seismic 97, Tab. I-9-1]
40.74 , for P
u
/f
b
P
y
> 0.125
{ MAX[ 191 / (F
y
)
0.5
(2.33-P
u
/f
b
P
y
) , 253 / (F
y
)
0.5
] for AISC Seismic 97, Tab. I-9-1}
[Satisfactory] Where f
c
= 0.9
P
y
= F
y
A = 2135 kips
CHECK COMPRESSION CAPACITY (AISC 360-05 E3)
f
c
P
n
= f
c
F
cr
A

= 1593.27 kips > P
u
[Satisfactory]
Where f
c
= 0.85
K = 1.0
MAX(KL
x
/r
x
, KL
y
/r
y
) = 42.19 < 200 [Satisfactory]
l
c
= 0.558 p
F
cr
= 43.90 ksi
<
(E
s
/F
y
)
0.5
MAX[1.49, 1.12(2.33 - C
a
)] =
Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05


h / t
w
= 16.79

You might also like