Single Layer Winding of Three Phase Induction Motor: Enesi Asizehi Yahaya
Single Layer Winding of Three Phase Induction Motor: Enesi Asizehi Yahaya
where A is an integer. B/C is reduced so that the numerator and the
denominator are the smallest possible integers, and cannot be mutually divisible. If the denominator C is an odd
number, the winding is said to be a first grade winding, and when C is an even number, the winding is of the
second grade. The most reliable fractional slot winding is constructed by selecting C=2. The winding of this
type can be designed for fractional slot permanent machines by selecting q=2.The total coil groups present in
three phase winding consist of B coil groups of (A+1) coils and (C-B) coil groups of A coils. The total coil
groups present in three phase winding consist of B coil groups of (A+1) coils and (C-B) coil groups of A coils.
The single layer winding parameters are shown in Table 1.
Table 1. Parameters for connecting single layer winding
Single layer fractional slot winding with Z=30, and 2P=4
.
2
5
2
1
2
C
D
q or q
A=2, B=1 and C=2 and D=5. There are B coil groups of (A+1) coils, that is, 1 coil
group of 3 coils. Also there are (B-C) coil groups of A coils, that is, 1 group of 2 coils. There are D coils in each
phase. The configuration can be written as 3 2 or 2 3. Configuration 3 2 is chosen. This configuration can
appear only 3 (number of phases) times so that the total number of coils in the winding is equal to Dm=5x3=15.
S/N Three-phase Single-layer winding
1 Connection of coils in
coil groups of the
three phase
U11 V12 W13 and U1-1, V1-5 and W1-3 for the unbifurcated concentric
and mush.
- 4 - 5 - 6
- 7 - 8 9
2 Number of parallel
branches, a
In integral slot winding, p/a=integer and in fractional slot winding, P/aC=integer
3 Orderly connection of
coil groups of each
phase
End (E) of first coil group to the start (S) of next coil group and the end of that coil
group to the start of the next coil group of the same phase (E-S-E-S-E-S) or End (E)
to End (E) and Start (S) to Start (S) of the next coil group of the same phase
depending on the number of poles of the winding
4 Winding type Concentric, lap or wave type, mush and 3-tier
5 Number of slots
Z=2Pmq
Z=2Pmq and a maxP
6 Pole pitch
Coil span
=Z/2P
y=Z/2P + 1, y=Z/2P - 1
7 Conditions of
symmetry
P/C N, meaning P cannot be 1 and for three phase C/m N
Single Layer Winding Of Three Phase Induction
www.theijes.com The IJES Page 12
There are two coil group per phase and a total of six (Cm) coil groups in the winding. The configurations are 3 2
3 2 3 2. Table 2 shows the distribution of coils belonging to each phase.
Table 2: Position of coil groups in each phase of winding
A 3 2
B 2 3
C 3 2
Figure 8 is the arrangement of coil groups and the various slots occupied by them. Each phase A, B and C
contains two coil groups with the first phase, A occupying the first and the fourth coil group. The winding
diagram is shown in Figure 6
Fig. 8: Coil group diagram of a single layer fractional slot winding with Z=30 and 2P=4
The winding diagram of a single layer fractional slot winding with Z=30 and 2P=4 is shown in figure 9 below
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
30
1
2
3
4
5
6 6
U1 U2
V1 V2 W1 W2
No. of coil group.
Fig. 9: Fractional slot winding with Z=30 and 2P=4
Single layer fractional slot winding with Z=36 slots and 2P=10
Table 3 shows the coil distribution per phase of a 3-phase stator winding have 36 slots and 10 poles. The number
of slots per pole per phase, q=Z/(2Pm)=36/(3x10)=1.2=
5
1
1 . A phase consists of B coil groups of (A+1) coils=1
group of (1+1) coils. 1 coil group of 2 coils and (C-B) coil groups of A coils. (5-1) groups of 1 coil=4 groups of l
coil.
C
D
q
5
6
. D is the number of coils in each phase of the winding and D is (2+1+1+1+1)=6. The total coil
groups in the winding is equal to Dm=6x3=18. One of the coil groups consists of two coils.
The coil groups are:
1 coil group has two coils
q1=2
4 coil groups having one coil q2=q3=q4=q5=1
A-B-C-A-B-C-A-B-C-A-B-C-A-B-C
2-1-1-1-1-2-1-1-1-1-2-1-1-1-1
Figure 10 shows the layout of coil group and their slot positions
Single Layer Winding Of Three Phase Induction
www.theijes.com The IJES Page 13
Table 3. Distribution of coil groups in each phase of the winding
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A 2 1 1 1 1
B 1 1 1 2 1
C 1 2 1 1 1
Fig. 10 : Coil group diagram of a single layer fractiional slot winding with Z=36 and 2P=10
The coil group schema defines the number of coils in the coil groups of a phase. The design of the winding is
shown in figure 11. There are five coil groups per phase and six coils per phase because one of the coil groups
contains two coils. The total coil group is fifteen (cm) while the total coils in the three phase is equal to
eighteen.
q1
A
q2
B
q3
C
q4
A
q5
B
q1
C
q2
A
q3
B
q4
C
q5
A
q1
B
q2
C
q3
B A
q4 q5
C
2 1 1 1 1 2 1 1 1 1 2 1 1 1 1
36 1
2
3
4
5
6
7 8 9
10 11
12
13
14 15 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
1 4 5 8
11
15 19 22 26 30 33
Winding construction of phase A using diamond winding. Fig. 7
No. of coil group.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(a)
(b)
slot no. 2
U1 U2
Fig. 11: A phase of single layer fractional slot winding with Z=36 and 2P=10
IV. CONCLUSION
The simplified method of winding configurations, layout diagrams and winding diagrams help the
Engineers and Technician working in rewinding workshop to have the basic knowledge of three phase single
layer winding of three phase induction motor.
REFERENCES
[1] Dr. Saud Ibrahim Shahl. Electrical Machines 11. PP1-5
[2] Hanne Jussia (2009). Concentric winding multiphase permanent magnet machine design and electromagnetic
properties-caes axial flux machine. Lappeenranta. PP18-20.
[3] Motor ABC for SIEMENS Low-voltage three phase motors. Fifth edition. 2004 PP144
[4] Ms. A. Sumathi, Mr. R. Krislinakumas , Mr. P. Bala Subramanion, Mr. K. S.Sampath Nagarian (2011). Electrical
Machines and Appliances Theory. First edition. 2011. PP33-52
[5] R.K. Agarwal (2000). Principle of Electrical Machine Design. Fouth Edition. PP314-320.