0% found this document useful (0 votes)
170 views

FCD-155E: STM-1/OC-3 Add-Drop Multiplexer

FCD-155E Manual Guide The FCD-155E transports next-generation Ethernet and TDM traffic over STM-1/OC-3 fiber or copper links. Standard next-generation STM-1/OC-3 ADM utilizing GFP, VCAT, LCAS Grooms Ethernet and E1/T1/E3/T3 traffic over STM-1/OC-3 fiber or copper links Multiservice functionality in the same box: Two or six 10/100BaseT ports or one GbE port Eight or 21 E1/28 T1 ports, one E3/DS3 port or 21 E1/28 T1 ports, one E3/T3 Optional dual power supply configuration SFP-based STM-1/OC-3 uplinks and Gigabit Ethernet interface (SFP and UTP) Advanced management option including DCC and IP tunneling Available with standard protection on the main link Compact size

Uploaded by

Gintang Prabowo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
170 views

FCD-155E: STM-1/OC-3 Add-Drop Multiplexer

FCD-155E Manual Guide The FCD-155E transports next-generation Ethernet and TDM traffic over STM-1/OC-3 fiber or copper links. Standard next-generation STM-1/OC-3 ADM utilizing GFP, VCAT, LCAS Grooms Ethernet and E1/T1/E3/T3 traffic over STM-1/OC-3 fiber or copper links Multiservice functionality in the same box: Two or six 10/100BaseT ports or one GbE port Eight or 21 E1/28 T1 ports, one E3/DS3 port or 21 E1/28 T1 ports, one E3/T3 Optional dual power supply configuration SFP-based STM-1/OC-3 uplinks and Gigabit Ethernet interface (SFP and UTP) Advanced management option including DCC and IP tunneling Available with standard protection on the main link Compact size

Uploaded by

Gintang Prabowo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

STM-1/OC-3 add/drop

multiplexer that
transports LAN and
traditional (TDM)
traffic over
SDH/SONET networks



STM-1/OC-3 PDH/Ethernet add/drop multiplexer for grooming LAN and legacy
(TDM) traffic over SDH/SONET networks
Ethernet traffic mapped to 1 VC-3/VC-4/STS-1, up to 3 VC-3/STS-1, up to 63
VC-12 or 84 VT-1.5
1+1 MSP/APS redundancy
PDH interface for 8 or 21 E1 (G.703), 8 or 28 T1 (G.703), 1 E3/T3, or 1 E3/T3
with 21/28 E1/T1 ports
10/100BaseT and GbE Ethernet interfaces with VLAN support and
point-to-multipoint switching capability

Family Product Name
FCD-155E
STM-1/OC-3 Add-Drop Multiplexer
Data Sheet
Where to buy >

See the product page >
FCD-155E is an STM-1/OC-3 add/drop
multiplexer that transports LAN and
traditional (TDM) traffic over SDH/SONET
networks. When bandwidth granularity of
the Ethernet channel is configured to
2 Mbps (VC-12) or 1.5 Mbps (VT-1.5),
FCD-155E utilizes the SDH/SONET
infrastructure for cost-effective
connectivity.
Optional PDH interface modules include:
8- or 21-port E1
8- or 28-port T1
Single-port E3/T3
Single-port E3 with 21-port E1
Single-port T3 with 21-port E1 or
28-port T1

FCD-155E
STM-1/OC-3 Add-Drop Multiplexer
Optional Ethernet interface configurations
include:
2-port bridging 10/100BaseT
6-port 10/100BaseT (two bridging and
four transparent ports)
Single-port Ethernet
10/100/1000BaseT (RJ-45) or
1000BaseSX (SFP interface).
NETWORK INTERFACE
The STM-1/OC-3 interfaces are
user-configurable and provide a high-
quality and high-availability link, as well as
performance monitoring of the traffic
path.
The STM-1/OC-3 link is supplied with an
SFP socket (see Ordering). It is strongly
recommended to order this device with
original RAD SFPs installed. This will
ensure that prior to shipping, RAD has
performed comprehensive functional
quality tests on the entire assembled unit,
including the SFP devices. RAD cannot
guarantee full compliance to product
specifications for units using non-RAD
SFPs.
The user can define the following
SDH/SONET clock sources:
Internal
Recovered from the STM-1/OC-3
interface, including automatic selection
based on SSM (Synchronization Status
Messaging)
External E1
Station clock.
FCD-155E features an optional ADM
configuration mechanism with SNCP path
protection.
Optional 1+1 link protection mechanism
(unidirectional MSP/APS) and SNCP path
protection are also available.
Maintenance capabilities include
user-activated local loopbacks and remote
loopbacks on the STM-1/OC-3 main link
and PDH tributaries.
LAN INTERFACE
The 2-port 10/100BaseT or single-port
Gigabit Ethernet interfaces include a
built-in Ethernet bridge that supports
VLAN according to IEEE 802.1Q and
802.1p.
The 4-port transparent LAN extension,
without bridge functionality, creates total
separation between customers, for
security. The maximum frame length is
2 kB.
The 10/100BaseT LAN interface features
autonegotiation for plug-and-play
Ethernet connectivity and complies to
IEEE 802.3/Ethernet V.2 standards. The
interface also features VLAN stacking.
An optional Gigabit Ethernet port connects
one LAN port to eight virtual groups. This
option provides LAN extension over
SDH/SONET networks with bridge
functionality. The maximum frame length
is 2 kB.
Ethernet traffic is mapped into
SDH/SONET containers using VCAT and
encapsulated with:
Generic Framing Procedure (ITU-T
G.7041, ANSI T1-105.02), framed
mode
Link Access Procedure for SDH/SONET
(LAPS) protocols following draft
recommendation ITU-T X.85/X.86.
Each users Ethernet traffic can be
mapped into SDH/SONET virtual containers
in any of the following ways:
Up to 63 VC-12, or 84 VT-1.5
3 VC-3/STS-1
1 VC-4.
Ethernet traffic can be switched to
different bundles of virtually concatenated
VCs (up to 8 bundles) according to a
predefined group.
Link Capacity Adjustment Scheme (LCAS) is
supported in compliance with the G.7042
standard, which allocates bandwidth
according to Ethernet traffic.
Gigabit
Ethernet
E3/T3
FCD-155E
Branch 1
Branch 7
FCD-155E
FCD-155E
Fast Ethernet
E1/T1
Fast Ethernet
E1/T1
SDH/SONET
Router
PBX
Headquarters
Router
PBX
PBX
Router

Figure 1. Corporate Ring Application



Data Sheet
SDH/SONET media can transport basic
Ethernet packets of up to 1536 bytes
enabling connection to MPLS networks.
The Spanning Tree Protocol (STP) and
Rapid Spanning Tree Protocol (RSTP)
support Layer 2 ring applications.
TDM INTERFACES
FCD-155E has an optional interface
module consisting of 8 or 21 balanced E1
or 8 or 28 T1 ports that transfer
transparent data in compliance with
G.703. The unbalanced E1 interface is
software-selectable.
An optional E3/T3 interface module
transports unframed E3/T3 data over
SDH/SONET.
Another optional interface module
combines E3 or T3 with 21 E1 ports, or T3
with 28 T1 ports.
TDM traffic is mapped into SDH/SONET
VC-12/VC-11/VC-3 or SONET VT1.5/STS-1
containers that can be placed anywhere
within the STM-1/OC-3 bandwidth.
MANAGEMENT
Remote units can be managed in the
following ways:
Via DCC using IP tunneling over OSI
DCN based on ITU-T G.7712
Via DCC based on IP/PPP protocols
Via a dedicated virtual group
containing at least one VC-12/VT-1.5
channel
Inside the user traffic in a virtual
group, separated from the user traffic
by the GFP Channel ID or VLAN tag
Out-of-band, via direct connection to
one of the LAN ports.
Status and diagnostic information is
defined, configured, and monitored using
one of the following methods:
ASCII terminal connected to the
V.24/RS-232 control port
Telnet host via management platform
or LAN port
Network management station running
RADview, the RAD SNMP network
management application
TFTP applications to update software
and upload/download remote
configurations
Web Based element manager.
DIAGNOSTICS
FCD-155E has comprehensive diagnostic
capabilities, including:
Ethernet and SDH/SONET link
monitoring
Real-time alarms to alert the user of
fault conditions. Alarms are reported
to the management station and
simultaneously relayed through a dry
contact port.
GENERAL
AC or DC power supplies are provided with
an alarm-activated fan for forced-air
cooling. They are available in redundant
and mixed AC/DC power supply
configurations.
FCD-155E is a compact 1U high 19-inch
unit that can be mounted in a 19-inch rack
with the optional rack-mount kit (see
Ordering).

FCD-155E
STM-1/OC-3
S
T
M
-
1
/
O
C
-
3
Protected VPN
PBX
LAN
Site 1
FCD-155E
PBX
LAN
Site 2
FCD-155E
PBX
LAN
Site 3
S
T
M
-
1
/O
C
-
3
SDH/SONET

Figure 2. VPN over SDH/SONET


FCD-155E
STM-1/OC-3 Add-Drop Multiplexer
Table 1. SFP Interface Characteristics
Transceiver Wavelength

[nm]
Fiber Type

[m]
Transmitter
Type
Connector
Type
Input Power
[dBm]
Output Power
[dBm]
Typical Max.
Range



(min) (max) (min) (max) [km] [miles]

S
T
M
-
1
/
O
C
-
3

U
p
l
i
n
k

SFP-1 1310 62.5/125 multimode LED LC -30 -14 -20 -14 2 1.2
SFP-2 1310 9/125 single mode Laser LC -28 -8 -15 -8 15 9.3
SFP-3 1310 9/125 single mode Laser LC -34 -10 -5 0 40 24.8
SFP-4 1550 9/125 single mode Laser LC -34 -10 -5 0 80 49.7
SFP-11 Copper uplink Coaxial cable 75 Mini-BNC 0.135* 0.08*
SFP-18A

Tx - 1310
Rx 1550
9/125 single mode
(single fiber)
Laser
(WDM)
LC -28 -8 -5 0 40 24.8
SFP-18B

Tx 1550
Rx 1310
9/125 single mode
(single fiber)
Laser
(WDM)
LC -28 -8 -5 0 40 24.8
SFP-19A

Tx 1490
Rx 1570
9/125 single mode
(single fiber)
Laser
(WDM)
LC -30 -8 0 +5 80 49.7
SFP-19B

Tx 1570
Rx 1490
9/125 single mode
(single fiber)
Laser
(WDM)
LC -30 -8 0 +5 80 49.7

G
b
E

U
s
e
r

P
o
r
t

SFP-5 850 50/125 multimode VCSEL LC -17 0 -9.5 0 0.55 0.3
SFP-6 1310 9/125 single mode Laser LC -20 -3 -9.5 -3 10 6.2
SFP-7 1550 9/125 single mode Laser LC -22 -3 0 +5 80 49.7
SFP-8D 1310 9/125 single mode Laser LC -21 -3 0 -4 40 24.8
* Using RG59 B/U.
Specifications
STM-1/OC-3 MAIN LINK
Number of Ports
1 (second link available for redundancy or
ring support)
Bit Rate
155.52 Mbps 20 ppm
SFP Transceivers
Characteristics: See Table 1
Options: See Ordering
Timing
Internal clock
Recovered from the STM-1/OC-3 interface
External clock from PDH tributary
Station clock
Compliance
SDH: ITU-T G.957
SONET: GR-253-core
Framing
SDH: ITU-T G.707, G.708, G.709
SONET: ANSI T1.105-1995,
GR-253-core
Line Code
NRZ
LAN INTERFACE (OPTIONAL)
Number of Ports
2 or 6 10/100BaseT ports
1 GbE
Compatibility
Relevant sections of IEEE 802.3u, 802.3x,
802.1D and 802.1Q
LAN Table
2,048 MAC addresses (2U) and 8,182
(GbE) with selectable automatic aging time
Data Rate
10BaseT: 10 Mbps
100BaseT: 100 Mbps
1000BaseT: 1000Mbps (Gigabit Ethernet)
Autonegotiation
Connectors (per port)
RJ-45, shielded
SFP socket (for transceivers, see Ordering)


Data Sheet
E1/T1 PDH INTERFACE
Number of Ports
8 E1, 21 E1, 8 T1, or 28 T1
Compatibility
ITU-T Rec. G.703, unframed
Nominal Data Rate
E1: 2.048 Mbps
T1: 1.554 Mbps
Line Code
E1: HDB3
T1: B8ZS
Impedance
E1: 120 balanced or
75 unbalanced
T1: 100 balanced
Maximum Line Attenuation
36 dB (LTU mode)
12 dB (DSU mode)
Timing
Source clock is recovered from the receive
signal coming from the remote E1/T1
side
Locked to the SDH/SONET interface clock
Connectors
8 E1, 8 T1: DB-44
21 E1, 28 T1: DB-62
E3/T3 PDH INTERFACE (OPTION)
Number of Ports
1
Compatibility
ITU-T Rec. G.703, unframed
Data Rate
E3: 34.368 Mbps
T3: 44.736 Mbps
Framing
Unframed
Line Code
E3: HDB3
T3: B3ZS
Line Impedance
75
Connector
2 BNC female
Timing
Source clock is recovered from the receive
signal from the remote E3/T3 side
Locked to the SDH/SONET interface clock
MANAGEMENT PORTS
Control Port
Interface: V.24/RS-232
Connector: 9-pin D-type, female
Format: Asynchronous
Baud rate: 0.3115.2 kbps
Selectable word format: 7 or 8 bits, no
parity, 7 bit odd or even parity
Out-of-Band Access
Single Ethernet port FCD-155E version:
NG ETH port
Other FCD-155E versions:
ETH 1 and ETH 2 ports (through
internal Ethernet switch)
INDICATORS
General
PWR (green) Power
TST (yellow) Test
MAJ ALM (red) Major alarm
MIN ALM (red) Minor alarm LOC SYNC
LOSS (red) Local loss of synchronization
on the STM-1/OC-3 links
REM SYNC LOSS (red) Remote loss of
synchronization on the STM-1/OC-3
links
ETH, MNG, GbE (per port)
LINK (green) LAN link integrity
ACT (yellow) LAN data activity
E1/T1 PDH Interface (per port)
LOS (red) Link signal loss
AIS (red) Alarm indication signal on link
E3/T3 PDH Interface
LOS (red) E3/T3 link signal loss
STM-1/OC-3 Main Links
LOS (red) STM-1/OC-3 link signal loss
ON LINE (green) STM-1/OC-3 link is
active (indicator is on) or standby
(indicator is blinking)
Station Clock
ON (green) Station clock port is
connected
LOS (red) Station clock signal loss
GENERAL
Power
100 to 240 VAC 10%, 50 to 60 Hz
-48 VDC (-40 to -72 VDC)
+24VDC
Power Consumption
30W
Alarms
Last 100 alarms are time stamped, stored,
and available for retrieval
Alarm Relay Port
Operation: normally open, normally
closed, using different pins
Connector: 9-pin, D-type, female
Physical
Height: 4.4 cm (1.7 in)
Width: 44.0 cm (17.3 in)
Depth: 25.4 cm (10.0 in)
Weight: 4.1 kg (9.0 lb)
Environment
Temperature: -10 to 60C (14 to 140F)
Humidity: Up to 90%, non-condensing



FCD-155E
STM-1/OC-3 Add-Drop Multiplexer

FCD-RIC Products Comparison Table

Feature
RIC-155
(Ver. 1.12)

RIC-155GE
(Ver. 2.0)

RIC-155L
(Ver. 2.5)


FCD-155
(Ver. 4.2)

FCD-155E
(Ver 1.2)


Frame Size
(Bytes)
64-1536 641664 6410000 64-1536
2K for transparent 8 GbE
64-1536
2K for transparent 8 GbE

Ethernet Speed FE FE/GE FE/GE FE/GE FE/GE
QoS 802.3p 802.1p 802.3p

802.1p
Port-based DSCP
802.1p
Port-based DSCP

MAC Address Table 1,024 16,384 12 1024 1024
Number of Queues N/A 4 (strict) 4 (strict) 4 (strict, WFQ 8,4,2,1) 4 (strict, WFQ 8,4,2,1)
Encapsulation HDLC HDLC GFP (G.7041),

GFP (G.7041),
LAPS (X.86)
GFP (G.7041),
LAPS (X.86)

SDH/SONET
Redundancy
No No No APS 1+1 APS 1+1
SNCP

Gigabit Ethernet
Redundancy
No No No Yes Yes
Hot-Swappable
Power Supplies
No Yes No No Yes
Power Supply
Redundancy
No Yes No No Yes
Terminal/ADM
Functionality
No No No No Yes
Number of E1/T1
Tributaries
N/A N/A N/A 4/8 E1
4/8 T1
8/21 E1
8/28 T1

Number of E3/T3
Tributaries
N/A N/A N/A 1 E3, 1 T3 1 E3, 1 T3
Possibility of
E1/T1 and E3/T3
Combination
N/A N/A N/A N/A Yes


Data Sheet
Ordering
STANDARD CONFIGURATIONS
FCD-155E/48R/2U/21E1
FCD-155E/AD/2U/21E1
FCD-155E/AD/6U/8E1
FCD-155E/48R/6U
FCD-155E/AC/6U/21E1
FCD-155E/AC/2U/21E1
FCD-155E/AC/2U/8E1
FCD-155E/48/2U/8E1
FCD-155E/48R/6U/21E1E3
FCD-155E/ACR/2U/21E1
FCD-155E-PACK1
SPECIAL CONFIGURATIONS
FCD-155E/*/&/$
STM-1/OC-3 Add/Drop Multiplexer
Notes: 1. SFP transceivers are not included in the
chassis for the uplink and/or the fiber GbE
interfaces (see SFP Transceivers).
2. The unit can come with E3/T3 and 21E1/28T1
installed together.
3. To manage the unit with IP tunneling, order
FCD-155-PACK1 separately.
Legend
* Power supply:
AC 100 to 240 VAC
AD redundant 100 to 240 VAC and
-48 VDC power supply
48 -48 VDC
ACR redundant AC power supply
48R redundant DC power supply
24R +24 VDC
& LAN interface:
2U 2 bridging 10/100BaseT ports
6U 2 bridging and 4 transparent
10/100BaseT ports
GE 1 10/100/1000BaseT (GbE)
port, copper interface and SFP
socket
$ PDH interface:
8E1 8 E1 ports
8T1 8 T1 ports
21E1 21 E1 ports
28T1 28 T1 ports
E3 1 E3 port
T3 1 T3 port
21E1E3 1 E3 ports and 21 E1
ports
21E1T3 1 T3 ports and 21 E1
ports
28T1T3 1 T3 ports and 28 T1
ports
FCD-155-PACK1
Software key for activating the
IP tunneling management option
SFP TRANSCEIVERS
(For redundancy, order two SFP
transceivers)
STM-1/OC-3 Uplink
SFP-1 STM-1/OC-3, 1310 nm
multimode LED,
LC connector
SFP-2 STM-1/OC-3, 1310 nm single
mode laser (S1.1),
LC connector
SFP-3 STM-1/OC-3, 1310 nm, single
mode laser, long haul (L1.1),
LC connector
SFP-4 STM-1/OC-3, 1550 nm single
mode laser, long haul (L1.2),
LC connector
SFP-4D STM-1/OC-3, 1550 nm single
mode laser, long haul (L1.2),
LC connector, DDM
SFP-11 STM-1/OC-3, electrical
interface, mini-BNC coaxial
connector
SFP-18a

STM-1/OC-3, Tx 1310,
Rx 1550, 9/125 single
mode (single fiber), laser
(WDM), LC connector
SFP-18b

STM-1/OC-3, Tx 1550
Rx 1310, 9/125 single
mode (single fiber), laser
(WDM), LC connector
SFP-19a

STM-1/OC-3, Tx 1490
Rx 1570, 9/125 single
mode (single fiber), laser
(WDM), LC connector
SFP-19b

STM-1/OC-3, Tx 1570
Rx 1490, 9/125 single
mode (single fiber), laser
(WDM), LC connector



4
6
0
-
1
0
2
-
1
2
/
1
2

(
1
.
2
)

S
p
e
c
i
f
i
c
a
t
i
o
n
s

a
r
e

s
u
b
j
e
c
t

t
o

c
h
a
n
g
e

w
i
t
h
o
u
t

p
r
i
o
r

n
o
t
i
c
e
.


1
9
8
8

2
0
1
2

R
A
D

D
a
t
a

C
o
m
m
u
n
i
c
a
t
i
o
n
s

L
t
d
.

T
h
e

R
A
D

n
a
m
e
,

l
o
g
o
,

l
o
g
o
t
y
p
e
,

a
n
d

t
h
e

t
e
r
m
s

E
t
h
e
r
A
c
c
e
s
s
,

T
D
M
o
I
P

a
n
d

T
D
M
o
I
P

D
r
i
v
e
n
,

a
n
d

t
h
e

p
r
o
d
u
c
t

n
a
m
e
s

O
p
t
i
m
u
x

a
n
d

I
P
m
u
x
,

a
r
e

r
e
g
i
s
t
e
r
e
d

t
r
a
d
e
m
a
r
k
s

o
f

R
A
D

D
a
t
a

C
o
m
m
u
n
i
c
a
t
i
o
n
s

L
t
d
.

A
l
l

o
t
h
e
r

t
r
a
d
e
m
a
r
k
s

a
r
e

t
h
e

p
r
o
p
e
r
t
y

o
f

t
h
e
i
r

r
e
s
p
e
c
t
i
v
e

h
o
l
d
e
r
s
.

International Headquarters
24 Raoul Wallenberg Street
Tel Aviv 69719, Israel
Tel. 972-3-6458181
Fax 972-3-6498250, 6474436
E-mail [email protected]
North America Headquarters
900 Corporate Drive
Mahwah, NJ 07430, USA
Tel. 201-5291100
Toll free 1-800-4447234
Fax 201-5295777
E-mail [email protected]
www.rad.com Order this publication by Catalog No. 803852



FCD-155E
STM-1/OC-3 Add-Drop Multiplexer
Data Sheet
GbE User
SFP-5 GbE, 850 nm multimode
VCSEL
SFP-6 GbE, 1310 nm single mode
laser (LX-SM)
SFP-7 GbE, 1550 nm single mode
laser, long haul LX-H (ZX)
SFP-8D GbE, 1310 nm single mode
laser, long haul (LX-H)
Note: It is strongly recommended to order this
device with original RAD SFPs installed. This will
ensure that prior to shipping, RAD has performed
comprehensive functional quality tests on the
entire assembled unit, including the SFP devices.
RAD cannot guarantee full compliance to product
specifications for units using non-RAD SFPs.
SUPPLIED ACCESSORIES
CBL-MINIBNC-BNC
Cable for adapting two mini-BNC
connectors to full sized BNC connectors
(supplied with SFP-11)
AC power cord (when AC power supply is
ordered)
DC adapter plug (when DC power supply is
ordered)
RM-34
Hardware for mounting one unit in a
19-inch rack
OPTIONAL ACCESSORIES
CBL-DB9F-DB9M-STR
Control port cable
FCD-155E-PS/AC
100240 VAC power supply module
FCD-155E-PS/48
-48 VDC power supply module
CBL-G703-8/^
8E1/8T1 interface cables for the DB-44
connector (one cable required per
interface):
Legend
^ Connector type:
RJ45 splits into 8 E1/T1 balanced
RJ-45 connectors
RJ45/X splits into 8 E1/T1 balanced
RJ-45 connectors
(cross-cable)
COAX splits into 8 pairs of E1
unbalanced BNC male
connectors
OPEN 8 4 unterminated free
leads, 2m (6.6 ft)

CBL-G703-14/#
14E1/14T1 interface cable for the DB-62
port connector
CBL-G703-28/#
Two CBL-G703-14/# interface cables for
the DB-62 port connector, to provide
21E1/28T1 capacity
Legend
# Connector type:
RJ45 splits into 14 E1/T1
balanced RJ-45 connectors
COAX splits into 14 pairs of E1
unbalanced BNC male
connectors
OPEN 14 4 unterminated free
leads 2m (6.6 ft)
PATCH for connection to 2 Telco
connectors, 2m (6.6 ft)
OP-A-ADAPTOR-28RJ
Patch panel, two CBL-G703-14/Patch
cables are not included.
OP-A-ADAPTOR-21BNC-FCD155E
Patch panel, includes two
CBL-G703-14/Patch cables.