0% found this document useful (0 votes)
77 views

Mixer

This document provides specifications for a mixer, including: - The materials of construction are PVDF, Alloy 20, and CS/AISI 316. - Key components include a jacket, flanges per ASME B16.5 and DIN 2633, and a sanitary screw connection per DIN 11851. - Operating conditions include a temperature range, design pressure, hydrotest pressure, maximum allowable working pressure, and maximum design metal temperature.

Uploaded by

EDUARDO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views

Mixer

This document provides specifications for a mixer, including: - The materials of construction are PVDF, Alloy 20, and CS/AISI 316. - Key components include a jacket, flanges per ASME B16.5 and DIN 2633, and a sanitary screw connection per DIN 11851. - Operating conditions include a temperature range, design pressure, hydrotest pressure, maximum allowable working pressure, and maximum design metal temperature.

Uploaded by

EDUARDO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Reg

Rev: 0 ENG-DAT-000428
Quantity:
PVDF
Alloy 20
Alloy 20
ASME B 16.5 300 RF
Radiography: PWHT Required:
CS
Insoluble in Each other
Temperature
Temperature
C
DIN 2633 PN16 Flange Type:
Pulsating with Pulsation pattern
No
With weld ends
DIN 11851 ( Sanitary screw connection )
With Jacket
V4A
ASME B 16.5 150 RF
With dosing pipe NPS With Flanges
Mixing Elements: (Removable/ Nonremovable) : Mixer wall Thickness:
Polypropylene V4A
N/A
CS+6mm
Mixer pipe:
Design:
Flow down
Mixing Elements:
Mixer pipe:
C
Flow up
Flow Rate
Pressure
Viscosity at operating conditions
Density at operating conditions
cP
MAWP: {*} Hydrotest Pressure: kPa MDMT: C
am3/h
kPa(g)
AISI 316
minimum
Other Diameters
Vertical
Actual pressure drop:
Interfacial tension =
Pressure kPa(g)
Are The Components: Soluble
maximum am3/h
kg/m3
1 Mixture 2 3 COMPONENT Unit
Name
Gaseous / Liquid / Solid
normal am3/h
Flow Pattern:
Planned Pipe diameter
Uniform
AISI 316
Max. allowed pressure drop: 70 kPa
Material of construction
Horizontal
Planned installation
Size (Diameter X Overall Length) =
Design :
Soluble Components
Desired homogeneity=
Operating :
Insoluble Components
Desired droplet / bubble size =
N/A
Jacket: Design Pressure
Weight (Without fluid/ With fluid/Operating):
Design Temperature Design Pressure
N/A
NOTE:
Plant/Area:
REV:
REVISION LOG
WO #:
Client:
Project:
DATA SHEET
MIXER
Equip. No:
Equip. Name:
ADL Doc. No:
Inner Pipe:
Design Temperature N/A
APP'D CHK'D BY DATE DESCRIPTION
Page 1 of 2
Rev: 0
Quantity:
PVDF
Radiography:
Insoluble in Each other
C
Pulsating with Pulsation pattern
No
DIN 11851 ( Sanitary screw connection )
With Jacket
Mixing Elements: (Removable/ Nonremovable) :
CS+6mm
Design:
C
MDMT: C
Mixture
REVISION LOG