0% found this document useful (0 votes)
40 views22 pages

Uw GJ 1775

This document summarizes the results of a network performance report and site check for the telecom site UW_GJ_1775 in Ahmedabad, India. Key findings include: - Voice and data services were tested across the site's 4 sectors with different antennas. GPRS was not working on the site. - Drive test results found Rx Qual below the 95% benchmark target, with 88.7% of samples between 0-5. - Other KPIs like call drop rate and call setup success rate met targets. - The site check found acceptable coverage, no feeder cable swaps needed, and no VSWR alarms. Functionality tests for calls and handovers also passed

Uploaded by

Vinay Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views22 pages

Uw GJ 1775

This document summarizes the results of a network performance report and site check for the telecom site UW_GJ_1775 in Ahmedabad, India. Key findings include: - Voice and data services were tested across the site's 4 sectors with different antennas. GPRS was not working on the site. - Drive test results found Rx Qual below the 95% benchmark target, with 88.7% of samples between 0-5. - Other KPIs like call drop rate and call setup success rate met targets. - The site check found acceptable coverage, no feeder cable swaps needed, and no VSWR alarms. Functionality tests for calls and handovers also passed

Uploaded by

Vinay Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 22

Network Performance Report For

SITE ID :: UW_GJ_1775
DISTRICT :: Ahmedabad
DATE :: 27-Sep-14
RF SINGLE SITE CHECK SHEET UW_GJ 1775 PART - 1
RF SINGLE SITE CHECK LIST 657
Site ID UW_GJ_1775 ID & IP Name
GU/AH/UN/11244 ATC
Site Name Balisana Site Type 9 M RTP Proposed
Address
Open Plot of Mr. Manharsinh Mohansinh
Rathod, Mr. Jayendrasinh Mohansinh Rathod
& Pavanba Mohansinh Rathod through their
POA Mr. Pravinsinh Mohansinh Rathod,
Building Height (mtrs) G+2=10 met
Cell ID 27751 27752 27753
Lat/Long (Nominal)
22.9791 72.57264
Lat/Long (Field)
22.97944 72.57226
City Ahmedabad BSC Ahmedabad-4
STATE GUJARAT SCFT Date 27-Sep-14
Integration Team NOC Number
SEC -1 Sector 2 Sector 3 Sector 4 Remarks if any
No of TRX 4 4 4
Tilt(E+M) 2+2 2+2 2+2
Antenna Height (Planned)
19 19 19

Antenna Height (Field)
19 19 19

Antenna Type (TSSR) Normal Normal Normal
Antenna Type (field)
DX-1710-2170-65-18i-
M
DX-1710-2170-65-18i-
M
DX-1710-2170-65-18i-
M

Azimuth (TSSR)
0 120 240

Azimuth (Field)
0 120 240

BCCH(Scanned) 655 660 657
Voice (All Scenarios
MOC/MTC/SMS/GPRS)
Y Y Y
Rx Qual (Near Site) 0 0 0
RX Level (Near Site) dBm -52 -51 -53
Cell ID Plot UW_GJ_1775 GRID = 200 M
BCCH PLOT UW_GJ_1775 GRID = 200 M
RX LEV Full (Ideal) UW_GJ_1775 GRID = 200 M
RX LEV Sub UW_GJ_1775 GRID = 200 M
RX QUALITY Sub UW_GJ_1775 GRID = 200 M
C/I UW_GJ_1775 GRID = 200 M
GPRS PLOT UW_GJ_1775 GRID = 200 M
Gprs Was Not working on Site
GPRS Histogram Plot GRID = 200 M UW_GJ_1775
Gprs Was Not working on site
Audit Photos Sectors UW_GJ 1775
Sector-1 Sector-2
Sector-3
Audit Photos Antennas UW_GJ 1775
Sector-1 Sector-2
Sector-3
Audit Photos Antennas UW_GJ 1775
Sector-1 Sector-2
Sector-3
Audit Photos Tower UW_GJ 1775
Audit Photos Road Block UW_GJ 1775
Audit Photos Road Block UW_GJ 1775
Event Statics UW_GJ_1775
RX Level (DBm) Sample Percentage (%)
0 to -65
6630 66.80100756
-65 to -70
2299 23.16372796
-70 to -75
825 8.312342569
-75 to -85
162 1.632241814
-85 to -95
9 0.090680101
-95 to -120
0 0
RX Qual Sample Percentage (%)
0 12893 65.92861526
1 641 3.277766414
2 640 3.272652894
3 877 4.484557169
4 981 5.016363264
5 1259 6.437921865
6 1479 7.562896298
7 786 4.019226836
DRIVE KPI UW_GJ_1775
Event [No. of samples]
Blocked Call 0
Call Attempt 19
Call Setup 19
Dropped Call 0
Call Success 19
TCH Call Drop Rate 0.00%
Call setup Success Rate 100%
ANY recommendation
DRIVE TEST STATISTIC UW_GJ_1775
Information Element
Bench
mark Units
Achieved
Acceptance
(Yes/No)
Comments
Rx Qual Sub >95 (%) 88.7% No
The rate of Rx
Qual
=0 to 5
Intra Cell Handover OK Yes Yes
Clockwise/Anticl
ockwise
Call Drop Rate 0.0(%) Yes Yes
Call Setup Success Rate 100 (%) 100% Yes
SCFT ACCEPTANCE UW_GJ_1775
Sr.
No.

Parameter

Target

Achieved

Acceptance
1
Coverage
Cell ID
Footprint

Yes

Yes
2
Feeder Cable Swap

No Swap

Yes

Yes
3
VSWR Alarm

<1.3

No Alarms

Yes
4
Rx Qual Drive Test

>95%

No

Yes
5
Functionality Test

Call/HO

Tested OK

Yes
Alcatel Lucent
Signature
Date:
UNINOR
Signature
Date: