Usa Fan Blower
Usa Fan Blower
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Page
Introduction F-80
MB Series F-82
MBD Series F-94
Cooling Fans
Centrifugal Blowers
AC Input
MB Series
DC Input
MBD Series
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
F-80
Centrifugal blowers provide directional air flow by
maximizing static pressure, making them optimal
for spot cooling and for air flow through a duct.
Alternatively, their high suction can be used to hold an
object in position or their directed air flow can be used
to move objects.
Features
Since the exhaust outlet is reduced to focus air to a specified direction, these blowers are used for spot cooling. The static pressure is also high,
which makes them a suitable choice when cooling equipment through which air cannot flow easily or when blowing air using a duct.
Types of Centrifugal Blowers
: Standard Type : Alarm Type : Pulse Sensor Type
Series Features
Power Supply
Voltage
Impeller Diameter [mm (in.)]
160
(6.30)
120
(4.72)
100
(3.94)
80
(3.15)
60
(2.36)
50
(1.97)
AC Centrifugal Blower
MB Series
Pages F-82F-93
AC input centrifugal blowers
The MB Series is recognized by UL/CSA Standards and
conforms to EN Standards. CE Marking is used in accordance
with the Low Voltage Directive. (Certification status differs
according to the product.)
RoHS-Compliant
The MB Series conforms to the RoHS Directive.
Single-Phase
100/110/115 VAC
Single-Phase
200/220/230 VAC
Three-Phase
200/220/230 VAC
DC Centrifugal Blower
MBD Series
Pages F-94F-99
DC input centrifugal blowers
RoHS-Compliant
The MBD Series conforms to the RoHS Directive.
24 VDC
48 VDC
A three-phase 220 VAC version is not available.
Details of safety standards Page H-2 For detailed product safety standard information including standards, file number and certification body, please visit www.orientalmotor.com.
System Configuration
An example of a system configuration with the MB Series.
MB Series
Accessories (Sold separately)
Example of System Configuration
Mounting Brackets
(Page F-125)
Filters
( Page F-120)
Duct Joints
( Page F-126)
Example of installing the lter
AC Power Supply
Power Supply
Voltage
B: Single-Phase 100/110/115 VAC D: Single-Phase 200/220/230 VAC T: Three-Phase 200/220/230 VAC
24: 24 VDC 24A: 24 VDC Low-Speed Alarm, Contact Alarm Type 24S: 24 VDC Pulse Sensor Type
48: 48 VDC 48S: 48 VDC Pulse Sensor Type
MB Series
50 Hz
70
80
90
100
60
50
40
30
20
10
0
0.1 0.2 0.5 0.6 0.7 0.4 0.3
Air Flow [m
3
/min]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.40
0.35
0.20
0.25
0.30
0.15
0.05
0.10
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0 15 10 5 20
Air Flow [CFM]
MB520
MB630
60 Hz
70
80
90
100
60
50
40
30
20
10
0
0.1 0.2 0.5 0.6 0.7 0.4 0.3
Air Flow [m
3
/min]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.40
0.35
0.20
0.25
0.30
0.15
0.05
0.10
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0 15 10 5 20
Air Flow [CFM]
MB520
MB630
MBD Series
400
450
500
550
350
300
250
200
150
50
100
0
0.5 1.0 2.5 3.0 3.5 2.0 1.5
Air Flow [m
3
/min]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
2.2
2.0
1.8
1.0
1.2
1.4
1.6
0.8
0.2
0.4
0.6
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0 80 100 60 40 20 120
Air Flow [CFM]
MBD12
MBD10
MBD8
50 Hz
700
800
900
1000
600
500
400
300
200
100
0
2.0 4.0 10.0 12.0 14.0 8.0 6.0
Air Flow [m
3
/min]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
4.0
3.5
2.0
2.5
3.0
1.5
0.5
1.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0 300 200 100 400
Air Flow [CFM]
MB1665
MB1255
MB1040
MB840
60 Hz
700
800
900
1000
600
500
400
300
200
100
0
2.0 4.0 10.0 12.0 14.0 8.0 6.0
Air Flow [m
3
/min]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
4.0
3.5
2.0
2.5
3.0
1.5
0.5
1.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0 300 200 100 400
Air Flow [CFM]
MB1665
MB840
MB1255
MB1040
Fan Kit
T- MB1255-D - GA
Fan Kit Order Code
Fan Model Name
GA: With finger guard, mounting bracket and mounting screws FA: With filter, mounting bracket and mounting screws
The MB1665, MB630 and MB520 only come with mounting brackets (A).
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-82
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
160 mm (6.30 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Thermal Protector
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level Capacitor
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A) F
MB1665-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
2.6
3.7
3.7
3.7
260
360
380
400
2750
3100
3200
3200
8.0
9.0
9.0
9.0
282
318
318
318
490
686
686
686
1.96
2.75
2.75
2.75
76
80
80
80
40
MB1665-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
1.3
1.8
1.8
1.3
1.8
245
340
360
270
370
2700
3000
3150
2750
3150
7.7
8.4
8.7
8.0
8.9
272
297
307
282
314
490
686
686
490
686
1.96
2.75
2.75
1.96
2.75
75
76
77
75
77
8.0
MB1665-T
Three-Phase 200
Three-Phase 200
Three-Phase 230
50
60
60
1.8
1.8
1.8
280
360
400
2750
3100
3200
8.0
9.0
9.0
282
318
318
490
686
686
1.96
2.75
2.75
76
80
80
, Capacitor Cap
, Operating Manual
Single-phase fans only
The following items are included in each product.
Air Flow Static Pressure Characteristics
700
800
900
1000
600
500
400
300
200
100
0
2.0 4.0 10.0 12.0 14.0 8.0 6.0
60 Hz
50 Hz
50 Hz
60 Hz
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 100 200 300 400
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.5
1.5
2.0
2.5
3.0
3.5
4.0
1.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 5 kg (11 lb.)
E059
76 (2.99)
83 (3.27) 10 (0.39)
228 (8.98)
9
0
(
3
.
5
4
)
13 (0.51) 7 (0.28)
1
0
0
(
3
.
9
4
)
2
2
7
(
8
.
9
4
)
2
4
.
5
(
0
.
9
6
)
113 (4.45)
222 (8.74)
20 (0.79)
2
2
.
5
9
3
(
3
.
6
6
)
1
3
2
(
5
.
2
0
)
Lead Wires 300 mm (12 in.)
UL Style 3271, AWG20
M4
Air Flow
25 (0.98)
3
0
(
1
.
1
8
)
Protective Earth Terminal
10 (0.39)
Unpainted
Rotation
Direction
R
1
(
R
0
.
0
4
)
R
1 (
R
0
.
0
4
)
9
0
.
5
(
3
.
5
6
)
1
2
1
(
4
.
7
6
)
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-83
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Capacitor (Included)
6 (0.24)
A
C
B
7
(
0
.
2
8
)
20
(0.79)
1
0
(
0
.
3
9
)
AMP#187
4.3
(0.169)
4
(
0
.
1
6
)
B
+
1
5
(
0
.
5
9
)
R
1
0 (
R
0
.
3
9
)
Capacitor Dimensions Table
Model Capacitor Model
Capacitor Dimensions mm (in.) Mass
g (oz.)
Capacitor Cap
A B C
MB1665-B CH400CFAUL 58 (2.28) 41 (1.61) 58 (2.28) 190 (6.7) Included
MB1665-D CH80BFAUL 58 (2.28) 35 (1.38) 50 (1.97) 150 (5.3) Included
Panel Cut-Out Unit = mm (in.)
1
3
2
(5
.2
0
)
76 (2.99)
9
3
(
3
.
6
6
)
Intake Side Outlet Side
Connection Diagrams
MB1665-B, MB1665-D
Capacitor
Black
Red
White
Line
PE
How to connect a capacitor Page F-129
MB1665-T
Red
White
Black
Line
L1(R)
L2(S)
L3(T)
PE
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Mounting Bracket PAS5A F-125
Fan
Mounting Bracket
Mounting Screws
[M625 mm (0.98 in.)]
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Product Line
Fan Kit Model
T-MB1665-B-A
T-MB1665-D-A
T-MB1665-T-A
See page F-82 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-84
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
120 mm (4.72 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Thermal Protector
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level Capacitor
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A) F
MB1255-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
1.3
1.6
1.6
1.6
110
150
150
150
2850
3300
3300
3300
4.4
5.1
5.1
5.1
155
180
180
180
309
441
441
441
1.24
1.77
1.77
1.77
67
71
71
72
10
MB1255-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
0.6
0.8
0.8
0.6
0.8
100
145
145
110
150
2850
3200
3300
2900
3300
4.4
4.9
5.1
4.5
5.2
155
173
180
159
184
314
451
451
314
451
1.26
1.81
1.81
1.26
1.81
67
69
71
67
71
2.0
MB1255-T
Three-Phase 200
Three-Phase 200
Three-Phase 220
Three-Phase 230
50
60
60
60
0.6
0.6
0.65
0.65
85
120
125
130
2850
3280
3300
3300
4.4
5.0
5.1
5.2
155
177
180
184
314
451
451
451
1.26
1.81
1.81
1.81
67
70
71
71
, Capacitor Cap
, Operating Manual
Single-phase fans only
The following items are included in each product.
Air Flow Static Pressure Characteristics
400
450
500
300
350
200
250
100
150
50
0
1.0 2.0 5.0 6.0 7.0 4.0 3.0
60 Hz
50 Hz
50 Hz
60 Hz
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 50 100 150 200
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.4
0.6
0.2
0.8
1.0
1.2
1.4
1.6
1.8
2.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 4 kg (8.8 lb.)
E060
1
0
2
(
4
.
0
2
)
9
6
(
3
.
7
8
)
2
2
.
5
18
(0.71)
58 (2.28)
10 (0.39) 65 (2.56)
179 (7.05)
7
8
.
5
(
3
.
0
9
)
12 (0.47)
174 (6.85)
90 (3.54)
1
7
6
(
6
.
9
3
)
8
5
(
3
.
3
5
)
1
5
(
0
.
5
9
)
Lead Wires 300 mm (12 in.)
UL Style 3271, AWG20
6.5 (0.26)
2
(0.08)
3
0
(
1
.
1
8
)
25
(0.98)
10 (0.39)
Unpainted
M4
Air Flow
Protective EarthTerminal
Rotation
Direction
R
1
(R
0
.
0
4
)
7
5
.
5
(
2
.
9
7
)
R1 (R0.04) 8
4
(3
.3
1
)
8
4
(3
.3
1
)
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-85
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Capacitor (Included)
4.3
(0.169)
20
(0.79)
A
C
B
+
1
0
(
0
.
3
9
)
B
4
.
5
(
0
.
1
8
)
4
(
0
.
1
6
)
1
0
(
0
.
3
9
)
6 (0.24)
AMP#187
Capacitor Dimensions Table
Model Capacitor Model
Capacitor Dimensions mm (in.) Mass
g (oz.)
Capacitor Cap
A B C
MB1255-B CH100CFAUL 48 (1.89) 22.5 (0.89) 31.5 (1.24) 40 (1.41) Included
MB1255-D CH20BFAUL 48 (1.89) 19 (0.75) 29 (1.14) 40 (1.41) Included
Panel Cut-Out Unit = mm (in.)
9
6
(3
.
7
8
)
58 (2.28)
7
8
.
5
(
3
.
0
9
)
Outlet Side Intake Side
Connection Diagrams
MB1255-B, MB1255-D
Capacitor
Black
Red
White
Line
PE
How to connect a capacitor Page F-129
MB1255-T
Red
White
Black
Line
L1(R)
L2(S)
L3(T)
PE
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Finger Guard FGB12 F-118
Filter FLB12 F-120
Mounting Bracket PAS6A F-125
Duct Joint FD12 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MB1255-B-GA
T-MB1255-B-FA
T-MB1255-D-GA
T-MB1255-D-FA
T-MB1255-T-GA
T-MB1255-T-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-84 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-86
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
100 mm (3.94 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Thermal Protector
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level Capacitor
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A) F
MB1040-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
0.50
0.55
0.55
0.55
45
55
55
55
2750
3050
3200
3200
2.3
2.6
2.6
2.6
81.2
91.8
91.8
91.8
206
284
284
284
0.826
1.14
1.14
1.14
60
63
64
64
3.0
MB1040-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
0.25
0.30
0.30
0.30
0.30
40
50
55
50
55
2750
3100
3200
2750
3250
2.3
2.6
2.7
2.4
2.7
81.2
91.8
95.3
84.7
95.3
206
304
304
206
304
0.826
1.22
1.22
0.826
1.22
61
64
65
61
65
1.2
Details of safety standards Page H-2
Fan, Capacitor
, Capacitor Cap
, Operating Manual
Single-phase fans only
The following items are included in each product.
Air Flow Static Pressure Characteristics
0.4 0.8 2.8 2.0 2.4 1.6 1.2
280
320
360
400
240
200
160
120
80
40
0
Air Flow [m
3
/min]
0 20 40 60 80
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.2
0.6
0.8
1.0
1.2
1.4
1.6
0.4
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
60 Hz
50 Hz
60 Hz
50 Hz
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 2 kg (4.4 lb.)
E027
7
9
(
3
.
1
1
)
8
6
(
3
.
3
9
)
2
2
.
5
74 (2.91)
7
4
(2
.9
1
)
1
5
(
0
.
5
9
)
1
5
6
(
6
.
1
4
)
7
5
(
2
.
9
5
)
12
(0.47)
44.5
(1.75)
50
(1.97) 10 (0.39)
134 (5.28)
6
9
(
2
.
7
2
)
10 (0.39)
148 (5.83)
Lead Wires 300 mm (12 in.)
UL Style 3266, AWG20
4.5 (0.18)
2
(0.08)
3
0
(
1
.
1
8
)
M4
Air Flow
Protective Earth Terminal
25
(0.98)
Rotation
Direction
R
2
(
R
0
.
0
8
)
6
6
(
2
.
6
0
)
10 (0.39)
Unpainted
R2 (R0.08)
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-87
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Capacitor (Included)
4.3
(0.169)
20
(0.79)
A
C
B
+
1
0
(
0
.
3
9
)
B
4
.
5
(
0
.
1
8
)
4
(
0
.
1
6
)
1
0
(
0
.
3
9
)
6 (0.24)
AMP#187
Capacitor Dimensions Table
Model Capacitor Model
Capacitor Dimensions mm (in.) Mass
g (oz.)
Capacitor Cap
A B C
MB1040-B CH30BFAUL 58 (2.28) 21 (0.83) 31 (1.22) 50 (1.77) Included
MB1040-D CH12BFAUL 37 (1.46) 18 (0.71) 27 (1.06) 30 (1.06) Included
Panel Cut-Out Unit = mm (in.)
8
6
(3
.3
9
)
44.5 (1.75)
6
9
(
2
.
7
2
)
Outlet Side Intake Side
Connection Diagram
Capacitor
Black
Red
White
Line
PE
How to connect a capacitor Page F-129
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Finger Guard FGB10 F-118
Filter FLB10 F-120
Mounting Bracket PAS4B F-125
Duct Joint FD10 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MB1040-B-GA
T-MB1040-B-FA
T-MB1040-D-GA
T-MB1040-D-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-86 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-88
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
80 mm (3.15 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Thermal Protector
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level Capacitor
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A) F
MB840-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
0.29
0.37
0.37
0.37
28
32
35
36
2800
3150
3300
3350
1.6
1.8
1.8
1.8
56.5
63.5
63.5
63.5
152
221
226
226
0.61
0.886
0.906
0.906
55
58
59
59
1.5
MB840-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
0.14
0.18
0.18
0.15
0.18
28
32
35
35
36
2800
3200
3350
2850
3350
1.6
1.8
1.8
1.6
1.8
56.5
63.5
63.5
56.5
63.5
152
221
226
157
226
0.61
0.886
0.906
0.63
0.906
55
58
59
55
59
2.5
MB840-T
Three-Phase 200
Three-Phase 200
Three-Phase 220
Three-Phase 230
50
60
60
60
0.12
0.15
0.15
0.15
25
28
30
30
2800
3200
3350
3350
1.6
1.8
1.8
1.8
56.5
63.5
63.5
63.5
152
221
226
226
0.61
0.886
0.906
0.906
55
58
59
59
, Capacitor Cap
, Operating Manual
Single-phase fans only
The following items are included in each product.
Air Flow Static Pressure Characteristics
280
320
360
400
240
200
160
120
80
40
0
0.4 0.8 2.8 2.0 2.4 1.6 1.2
Air Flow [m
3
/min]
0 20 40 60 80
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.2
0.6
0.8
1.0
1.2
1.4
1.6
0.4
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
60 Hz
50 Hz
60 Hz
50 Hz
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 1.3 kg (2.9 lb.)
E062
8
0
(
3
.
1
5
)
7
6
(
2
.
9
9
)
2
2
.
5
122 (4.80)
60 (2.36)
6
4
(2
.5
2
)
1
2
8
(
5
.
0
4
)
114 (4.49)
50
(1.97)
2
(0.08)
44 (1.73)
5
4
(
2
.
1
3
)
12.5 (0.49)
10 (0.39)
6
0
(
2
.
3
6
)
1
4
(
0
.
5
5
)
10 (0.39)
Lead Wires 300 mm (12 in.)
UL Style 3266, AWG20
Air Flow
Rotation
Direction
25
(0.98)
3
0
(
1
.
1
8
)
Protective Earth Terminal
M4
R
2
(R
0
.
0
8
)
5
2
.
5
(
2
.
0
7
)
R2 (R0.08)
10 (0.39)
Unpainted
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-89
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Capacitor (Included)
4.3
(0.169)
20
(0.79)
A
C
B
+
1
0
(
0
.
3
9
)
B
4
.
5
(
0
.
1
8
)
4
(
0
.
1
6
)
1
0
(
0
.
3
9
)
6 (0.24)
AMP#187
Capacitor Dimensions Table
Model Capacitor Model
Capacitor Dimensions mm (in.) Mass
g (oz.)
Capacitor Cap
A B C
MB840-B CH15FAUL 31 (1.22) 14.5 (0.57) 23.5 (0.93) 35 (1.24) Included
MB840-D CH25FAUL 31 (1.22) 17 (0.67) 27 (1.06) 40 (1.41) Included
Panel Cut-Out Unit = mm (in.)
7
6
(2
.9
9
)
44 (1.73)
5
4
(
2
.
1
3
)
Outlet Side Intake Side
Connection Diagrams
MB840-B, MB840-D
Capacitor
Black
Red
White
Line
PE
How to connect a capacitor Page F-129
MB840-T
L1(R)
L2(S)
L3(T)
Red
White
Black
Line
PE
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Finger Guard FGB8 F-118
Filter FLB8 F-120
Mounting Bracket PAS4B F-125
Duct Joint FD8 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MB840-B-GA
T-MB840-B-FA
T-MB840-D-GA
T-MB840-D-FA
T-MB840-T-GA
T-MB840-T-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-88 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-90
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
60 mm (2.36 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Impedance Protected
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A)
MB630-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
0.11
0.11
0.12
0.12
8.0
8.0
9.5
10.0
2300
1900
2300
2500
0.44
0.36
0.45
0.49
15.5
12.7
15.9
17.3
53
76
77
79
0.213
0.305
0.309
0.317
37
33
38
40
MB630-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
0.08
0.08
0.08
0.09
0.08
12.0
11.0
13.0
16.0
14.0
2500
2600
2900
2600
2900
0.49
0.50
0.55
0.50
0.55
17.3
17.7
19.4
17.7
19.4
56
83
83
56
83
0.225
0.333
0.333
0.225
0.333
38
39
42
39
43
Details of safety standards Page H-2
Fan, Operating Manual
The following items are included in each product.
Air Flow Static Pressure Characteristics
70
80
90
100
60
50
40
30
20
10
0
0.7 0.4 0.5 0.6 0.3 0.2 0.1
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
0
0.05
0.15
0.20
0.25
0.30
0.35
0.40
0.10
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Air Flow [m
3
/min]
0 5 10 15 20
Air Flow [CFM]
60 Hz
50 Hz
60 Hz
50 Hz
Static Pressure
Speed
Dimensions Unit = mm (in.)
Mass: 0.5 kg (1.1 lb.)
E063
6
0
(
2
.
3
6
)
4
8
(
1
.
8
9
)
22.5
75 (2.95)
40
(1.59)
1
(0.04) 6 (0.24)
3
6
(
1
.
4
2
)
35
(1.38)
9 (0.35) 1 (0.04)
90 (3.54)
46 (1.81)
9
0
(
3
.
5
4
)
4
0
(
1
.
5
7
)
1
0
(
0
.
3
9
)
8 (0.31)
6
7
(
2
.
6
4
)
Lead Wires 300 mm (12 in.)
UL Style 3266, AWG20
2
0
(
0
.
7
9
)
15 (0.59)
Air Flow
Protective Earth
Terminal M4
Rotation Direction
3
5
(
1
.
3
8
)
R1
(R0.04)
10 (0.39)
Unpainted
42(1.65)
3M3
R1 (R0.04)
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-91
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Connection Diagram
Line
PE
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Mounting Bracket PAS2B F-125
Fan
Mounting Bracket
Mounting Screws
[M410 mm (0.39 in.)]
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Product Line
Fan Kit Model
T-MB630-B-A
T-MB630-D-A
See page F-90 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Panel Cut-Out Unit = mm (in.)
33.5
(0.138)
120
4
8
(1
.
8
9
) 6
7
(
2
.6
4)
35 (1.38)
3
6
(
1
.
4
2
)
Outlet Side Intake Side
Page
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Features F-80 / System Configuration F-80 / General Specifications F-81
F-92
A
C
I
n
p
u
t
1
6
0
m
m
(
6
.
3
0
i
n
.
)
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
6
0
m
m
(
2
.
3
6
i
n
.
)
5
0
m
m
(
1
.
9
7
i
n
.
)
Centrifugal Blowers/AC Input
AC Centrifugal Blower
MB Series
Impeller Diameter
50 mm (1.97 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Impedance Protected
Bearings: Ball Bearings
Specifications
Model
Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level
VAC Hz A W r/min m
3
/min CFM Pa inH2O dB (A)
MB520-B
Single-Phase 100
Single-Phase 100
Single-Phase 110
Single-Phase 115
50
60
60
60
0.11
0.10
0.11
0.11
8
7
8.5
9
2600
3000
3200
3200
0.21
0.24
0.25
0.25
7.41
8.47
8.83
8.83
37
53
55
55
0.149
0.213
0.221
0.221
33
37
38
38
MB520-D
Single-Phase 200
Single-Phase 200
Single-Phase 220
Single-Phase 230
Single-Phase 230
50
60
60
50
60
0.09
0.08
0.09
0.10
0.09
11
10
12
16
13
2650
3200
3300
2750
3300
0.22
0.27
0.27
0.23
0.27
7.77
9.53
9.53
8.12
9.53
38
58
60
40
60
0.153
0.233
0.241
0.16
0.241
33
38
38
33
38
Details of safety standards Page H-2
Fan, Operating Manual
The following items are included in each product.
Air Flow Static Pressure Characteristics
70
80
90
100
60
50
40
30
20
10
0
0.28 0.16 0.20 0.24 0.12 0.08 0.04
0
500
1500
2000
2500
3000
3500
4000
4500
5000
1000
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 2.0 4.0 6.0 8.0
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.05
0.15
0.20
0.25
0.30
0.35
0.40
0.10
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
60 Hz
50 Hz
60 Hz
50 Hz
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 0.3 kg (0.7 lb.)
E064
6
0
(
2
.
3
6
)
4
0
(
1
.
5
7
)
22.5
5
6
(
2
.
2
0
)
40 (1.57)
78 (3.07)
4
0
(
1
.
5
7
)
4
(
0
.
1
6
)
7
8
(
3
.
0
7
)
20.5 (0.81)
25
(0.98)
57.5 (2.26)
3
6
(
1
.
4
2
)
8 (0.31) 0.5 (0.02)
4 (0.16)
8 (0.31)
Lead Wires 300 mm (12 in.)
UL Style 3266, AWG20
0.5 (0.02)
10
(0.39)
M4
2
0
(
0
.
7
9
)
Air Flow
Protective Earth Terminal
Rotation Direction
R1 (R0.04)
R1 (R0.04)
10 (0.39)
Unpainted 3M3
3
6
(1
.4
2
)
Cooling Fans
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
F-93
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Connection Diagram
Line
PE
Thermostats
A thermostat makes it possible for fans to operate only when cooling
is necessary, thereby conserving energy.
Thermostats AM1-WA1/AM1-XA1
Page F-113
Accessories
Product Model Page
Mounting Bracket PAS2B F-125
Fan
Mounting Bracket
Mounting Screws
[M410 mm (0.39 in.)]
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Product Line
Fan Kit Model
T-MB520-B-A
T-MB520-D-A
See page F-92 to determine base fan required (Voltage) and page F-81 for fan kits product
number code.
Panel Cut-Out Unit = mm (in.)
33.5
(0.138)
120
20.5
(0.81)
3
6
(
1
.
4
2
)
4
0
(
1
.
5
7
)
5
6
(
2
.2
0)
Outlet Side Intake Side
F-94
Centrifugal Blowers/DC Input
D
C
I
n
p
u
t
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Page
Features F-80 / System Configuration F-80 / General Specifications F-81
DC Centrifugal Blower
MBD Series
Impeller Diameter
120 mm (4.72 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Overheat Protection
Circuit
Bearings: Ball Bearings
Specifications
Function Model
Voltage Current Speed Max. Air Flow Max. Static Pressure Noise Level
VDC A r/min m
3
/min CFM Pa inH2O dB (A)
Low-Speed Alarm, Contact Alarm Type
(Alarm specifications: )
MBD12-24A 24 1.5 1900 3.0 106 372 1.49 58
Standard Type MBD12-24 24 1.5 1900 3.0 106 372 1.49 58
Alarm specifications Page F-22
Fan, Operating Manual
The following items are included in each product.
Air Flow Static Pressure Characteristics
400
450
500
550
350
300
250
200
150
100
50
0
4000
4500
5000
5500
3500
3000
2500
2000
1500
1000
500
0
0.5 1.0 3.5 2.5 3.0 2.0 1.5
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 20 40 60 80 100 120
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.4
0.2
0.6
1.0
0.8
1.6
1.2
1.4
2.2
1.8
2.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 1.5 kg (3.3 lb.)
E031
9
6
(
3
.
7
8
)
8
0
(
3
.
1
5
)
R
1 (
R
0
.
0
4
)
Air Flow
90 (3.54)
174 (6.85)
8
5
(
3
.
3
5
)
1
5
(
0
.
5
9
)
1
7
6
(
6
.
9
3
)
18 (0.71)
8
4
(3
.
3
1
)
7
8
.
5
(
3
.
0
9
)
58 (2.28)
49.5 (1.95)
65
(2.56)
2
(0.08)
10
(0.39)
131.5 (5.18)
Lead Wires 300 mm (12 in.)
UL Style 1007, AWG24
Rotation Direction
R
1
(
R
0
.
0
4
)
7
5
.
5
(
2
.
9
7
)
12 (0.47)
22.5
F-95
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Panel Cut-Out Unit = mm (in.)
9
6
(3
.
7
8
)
58 (2.28)
7
8
.
5
(
3
.
0
9
)
Outlet Side Intake Side
Connection Diagram
Alarm Output
(Alarm type only)
GND
Red
Black
White
Blue
+
24 VDC
Accessories
Product Model Page
Finger Guard FGB12 F-118
Filter FLB12 F-120
Mounting Bracket PAS4B F-125
Duct Joint FD12 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MBD12-24A-GA
T-MBD12-24A-FA
T-MBD12-24-GA
T-MBD12-24-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-94 to determine base fan required (Voltage/Alarm) and page F-81 for fan kits
product number code.
F-96
Centrifugal Blowers/DC Input
D
C
I
n
p
u
t
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Page
Features F-80 / System Configuration F-80 / General Specifications F-81
DC Centrifugal Blower
MBD Series
Impeller Diameter
100 mm (3.94 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Overheat Protection
Circuit
Bearings: Ball Bearings
Specifications
Function Model
Voltage Current Speed Max. Air Flow Max. Static Pressure Noise Level
VDC A r/min m
3
/min CFM Pa inH2O dB (A)
Low-Speed Alarm, Contact Alarm Type
(Alarm specifications: )
MBD10-24A 24 1.0 2400 1.95 68.8 294 1.18 56
Pulse Sensor Type
(Alarm specifications: )
MBD10-24S 24 1.0
2400 1.95 68.8 294 1.18 56
MBD10-48S 48 0.7
Standard Type
MBD10-24 24 1.0
2400 1.95 68.8 294 1.18 56
MBD10-48 48 0.7
Alarm specifications , Page F-22
Fan, Operating Manual
The following items are included in each product.
Air Flow Static Pressure Characteristics
400
450
500
550
350
300
250
200
150
100
50
0
0.5 1.0 3.5 2.5 3.0 2.0 1.5
4000
4500
5000
5500
3500
3000
2500
2000
1500
1000
500
0
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 20 40 60 80 100 120
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.4
0.2
0.6
1.0
0.8
1.6
1.2
1.4
2.2
1.8
2.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 1.2 kg (2.6 lb.)
E032
8
0
(
3
.
1
5
)
8
6
(
3
.
3
9
)
22.5
Air Flow
74 (2.91)
148 (5.83)
7
5
(
2
.
9
5
)
1
5
(
0
.
5
9
)
1
5
6
(
6
.
1
4
)
12 (0.47)
74
(2.91
)
10 (0.39)
6
9
(
2
.
7
2
)
44.5
(1.75)
49.5
(1.95)
50
(1.97)
2
(0.08)
10 (0.39)
6
6
(
2
.
6
0
)
116.5 (4.59)
Lead Wires 300 mm (12 in.)
UL Style 1007, AWG24
R
2
(
R
0
.
0
8
)
R
2
(
R
0
.
0
8
)
Rotation Direction
F-97
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Panel Cut-Out Unit = mm (in.)
8
6
(3
.3
9
)
44.5 (1.75)
6
9
(
2
.
7
2
)
Outlet Side Intake Side
Connection Diagrams
Low-Speed Alarm, Contact Alarm Type
24 VDC or 48 VDC
Alarm Output
GND
Red
Black
White
Blue
+
Pulse Sensor Type, Standard Type
24 VDC or 48 VDC
Pulse Sensor Output
(Pulse sensor type only)
Red
Black
GND
Yellow
+
Accessories
Product Model Page
Finger Guard FGB10 F-118
Filter FLB10 F-120
Mounting Bracket PAS4B F-125
Duct Joint FD10 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MBD10-24A-GA
T-MBD10-24A-FA
T-MBD10-24S-GA
T-MBD10-24S-FA
T-MBD10-24-GA
T-MBD10-24-FA
T-MBD10-48S-GA
T-MBD10-48S-FA
T-MBD10-48-GA
T-MBD10-48-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-96 to determine base fan required (Voltage/Alarm) and page F-81 for fan kits
product number code.
F-98
Centrifugal Blowers/DC Input
D
C
I
n
p
u
t
1
2
0
m
m
(
4
.
7
2
i
n
.
)
1
0
0
m
m
(
3
.
9
4
i
n
.
)
8
0
m
m
(
3
.
1
5
i
n
.
)
ORIENTAL MOTOR GENERAL CATALOG
2012/2013
Page
Features F-80 / System Configuration F-80 / General Specifications F-81
DC Centrifugal Blower
MBD Series
Impeller Diameter
80 mm (3.15 in.)
Operating Voltage Range: 10%
Materials
Motor Case: Die Cast Aluminum
Casing: Die Cast Aluminum
Impeller: Aluminum
Overheat Protection: Built-in Overheat Protection Circuit
Bearings: Ball Bearings
Specifications
Function Model
Voltage Current Speed Max. Air Flow Max. Static Pressure Noise Level
VDC A r/min m
3
/min CFM Pa inH2O dB (A)
Low-Speed Alarm, Contact Alarm Type
(Alarm specifications: )
MBD8-24A 24 0.7 2600 1.45 51.2 196 0.786 51
Pulse Sensor Type
(Alarm specifications: )
MBD8-24S 24 0.7
2600 1.45 51.2 196 0.786 51
MBD8-48S 48 0.5
Standard Type
MBD8-24 24 0.7
2600 1.45 51.2 196 0.786 51
MBD8-48 48 0.5
Alarm specifications , Page F-22
Fan, Operating Manual
The following items are included in each product.
Air Flow Static Pressure Characteristics
400
450
500
550
350
300
250
200
150
100
50
0
0.5 1.0 3.5 2.5 3.0 2.0 1.5
4000
4500
5000
5500
3500
3000
2500
2000
1500
1000
500
0
S
p
e
e
d
[
r
/
m
i
n
]
Air Flow [m
3
/min]
0 20 40 60 80 100 120
Air Flow [CFM]
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
P
a
]
0
0.4
0.2
0.6
1.0
0.8
1.6
1.2
1.4
2.2
1.8
2.0
S
t
a
t
i
c
P
r
e
s
s
u
r
e
[
i
n
H
2
O
]
Speed
Static Pressure
Dimensions Unit = mm (in.)
Mass: 1.1 kg (2.4 lb.)
E033
8
0
(
3
.
1
5
)
7
6
(
2
.
9
9
)
22.5
Air Flow
60 (2.36)
6
4
(2
.5
2
)
122 (4.80)
6
0
(
2
.
3
6
)
1
4
(
0
.
5
5
)
1
2
8
(
5
.
0
4
)
10 (0.39)
5
4
(
2
.
1
3
)
44 (1.73)
49.5
(1.95)
50
(1.97)
2
(0.08) 10 (0.39)
116.5 (4.59)
Lead Wires 300 mm (12 in.)
Rotation Direction
R
2
(R
0
.
0
8
)
R
2
(
R
0
.
0
8
)
5
2
.
5
(
2
.
0
7
)
UL Style 1007, AWG24
12.5 (0.49)
F-99
CAD Data
Manuals
www.orientalmotor.com Technical
Support
TEL: (800) 468-3982
E-mail: [email protected]
Cooling Fans
I
n
t
r
o
d
u
c
t
i
o
n
A
x
i
a
l
F
l
o
w
F
a
n
s
C
e
n
t
r
i
f
u
g
a
l
B
l
o
w
e
r
s
C
r
o
s
s
F
l
o
w
F
a
n
s
C
o
o
l
i
n
g
M
o
d
u
l
e
T
h
e
r
m
o
s
t
a
t
s
A
c
c
e
s
s
o
r
i
e
s
I
n
s
t
a
l
l
a
t
i
o
n
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
A
C
I
n
p
u
t
D
C
I
n
p
u
t
M
R
S
V
a
r
i
a
b
l
e
F
l
o
w
M
R
S
M
U
M
D
S
/
M
D
L
o
n
g
-
L
i
f
e
M
D
E
M
B
M
B
D
M
F
M
F
D
F
M
Panel Cut-Out Unit = mm (in.)
7
6
(2
.9
9
)
44 (1.73)
5
4
(
2
.
1
3
)
Outlet Side Intake Side
Connection Diagrams
Low-Speed Alarm, Contact Alarm Type
24 VDC or 48 VDC
Alarm Output
GND
Red
Black
White
Blue
+
Pulse Sensor Type, Standard Type
24 VDC or 48 VDC
Pulse Sensor Output
(Pulse sensor type only)
Red
Black
GND
Yellow
+
Accessories
Product Model Page
Finger Guard FGB8 F-118
Filter FLB8 F-120
Mounting Bracket PAS4B F-125
Duct Joint FD8 F-126
Fan Kit
The lineup includes a product configuration containing all
necessary accessories in one package.
Fan
Mounting Bracket
Mounting Screws
[M520 mm (0.79 in.)]
Finger Guard or Filter
Product Line
Fan Kit Model
T-MBD8-24A-GA
T-MBD8-24A-FA
T-MBD8-24S-GA
T-MBD8-24S-FA
T-MBD8-24-GA
T-MBD8-24-FA
T-MBD8-48S-GA
T-MBD8-48S-FA
T-MBD8-48-GA
T-MBD8-48-FA
-GA (Included with finger guard, mounting bracket and mounting screws)
-FA (Included with filter, mounting bracket and mounting screws)
See page F-98 to determine base fan required (Voltage/Alarm) and page F-81 for fan kits
product number code.
F-100
Centrifugal Blowers/DC Input
ORIENTAL MOTOR GENERAL CATALOG
2012/2013