8244CD Excel-Template Double-pipe-heat-exchanger-Design P1and2 Us Units

This document summarizes the preliminary design of a heat exchanger. It provides input parameters such as fluid properties and mass flow rates. It then shows calculations to determine the required heat transfer area of 96.9 sqft based on a heat transfer rate of 925,000 Btu/hr. Additional calculations determine that with the known heat transfer area, a pipe length of 61.7 ft is required for a pipe diameter of 0.5 ft. Equations used in the calculations include equations for the log mean temperature difference, heat transfer rate, and determining pipe length from the heat transfer area and diameter.

Uploaded by

ahmadlie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

8244CD Excel-Template Double-pipe-heat-exchanger-Design P1and2 Us Units

This document summarizes the preliminary design of a heat exchanger. It provides input parameters such as fluid properties and mass flow rates. It then shows calculations to determine the required heat transfer area of 96.9 sqft based on a heat transfer rate of 925,000 Btu/hr. Additional calculations determine that with the known heat transfer area, a pipe length of 61.7 ft is required for a pipe diameter of 0.5 ft. Equations used in the calculations include equations for the log mean temperature difference, heat transfer rate, and determining pipe length from the heat transfer area and diameter.

Uploaded by

ahmadlie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Preliminary Heat Exchanger Design (U.S.

units) (pages 1 & 2)


Estimation of Heat Transfer Area Needed
Inputs Calculations
Fluid
1
mass flow
Heat Transfer Rate, Q = 925,000 Btu/hr
rate, m
1
=
25,000 lb/hr
Log Mean Temp 79.6
o
F
Fluid
1
temp. in, T
1in
=
190
o
F
Diff, DT
lm
=
Fluid
1
temp. out, T
1out
=
140
o
F Heat Transfer Area, A =
96.9
ft
2
Fluid
1
sp. heat, C
p1
=
0.74
Btu/lb-
o
F
Fluid
2
mass flow
rate, m
2
=
13,214 lb/hr
Fluid
2
temp. in, T
2in
=
50
o
F
Fluid
2
temp. out, T
2out
=
120
o
F
Fluid
2
sp. heat, C
p2
=
1.0
Btu/lb-
o
F
Overall heat transf.
coeff. estim., U =
120
Btu/lhr-ft
2
-
o
F
Equations used for calculations:
Q = + (m
1
)(C
p1
)(T
1in
- T
1out
)
Q = + (m
2
)(C
p2
)(T
2in
- T
2out
)
DT
lm
= [(T
1in
- T
2out
) - (T
1out
- T
2in
)]/ln[(T
1in
- T
2out
)/(T
1out
- T
2in
)]
Q = U A DT
lm
Preliminary Double Pipe Heat Exchanger Design
Determination of pipe length needed (for known heat transfer area)
Inputs Calculations
Heat Transfer Area, A =
96.9
ft
2
Pipe Diam. in ft, D =
0.5000 ft
(from calculations above)
Pipe length needed, L = 61.7 ft
pipe Diameter, D
in
= 6 in
(in inches)
Equations used for calculations:
D = D
in
/12
A = pDL