Case Study
Nuclear Power Station Service Water Pump NPSH
Hydraulic Model Using AFT Fathom Company: Location:
Duke Energy Charlotte, NC, USA
According to Norman Stambaugh, a Senior Engineer
with Duke Energy, to assure that the RN system can adequately perform its safety function, it must be Duke Energy is one of the largest electric power demonstrated that the RN pump NPSHr can be met companies in the United States, supplying and under DBA conditions. Over the years, corrosion in delivering energy to approximately 4 million U.S. the RN pump suction piping has occurred, thus customers. Duke Energy has approximately 35,000 reducing the NPSHa. To analyze this degradation, megawatts of electric generating capacity in the an AFT Fathom model of the Carolinas and the Midwest, and RN pump suction piping was natural gas distribution services The roughness and developed and benchmarked. in Ohio and Kentucky. Their scaling factors were This model not only accounts for commercial and international slightly adjusted to obtain a the details relating to the piping businesses own and operate configuration, but also for the diverse power generation assets very accurate benchmark to details relating to the roughness in North America and Latin actual test data (0.1 to 0.2 and constriction of the piping America, including a portfolio of due to the build-up of corrosion psig). renewable energy assets. over time. It also provides the ability to input most limiting conditions, such as Nuclear Service Water (RN) systems circulate the maximum temperatures and minimum levels for the water that cools the plants heat exchangers and lake and pond supplies, as well as various amounts other components before dissipating the heat into of assumed RN strainer fouling. the environment. Because this is a safety-critical Using AFT Fathom, Duke Energy was able to system, it is essential to accurately understand how benchmark corroded pipe performance, and the system works under varying operating accurately model the potential pressure recovery conditions, and under Design Basis Accident (DBA) after cleaning the pipes. Conditions.
McGuire Nuclear Power Station
Applied Flow Technology 2955 Professional Place, Suite 301, Colorado Springs, CO 80904 USA www.aft.com
POND SUPPLY
1B and 2B Pumps
McGUIRE NUCLEAR STATION
RN PUMP NPSH HYDRAULIC MODEL
1A and 2A Pumps
LAKE SUPPLY
Comparison of AFT Fathom model results to test results at McGuire Pump