This document summarizes the results of an external beam IMRT planning competency evaluation for Andy Kressin from January 1, 2014 to December 8, 2014. Four evaluations were included in the analysis. The competency covered tasks related to imaging, contouring, treatment planning, and quality assurance. Most tasks were rated as satisfactory. Areas that received unsatisfactory ratings included accurately fusing image data sets together, optimizing and generating a concomitant boost plan, and observing IMRT QA and analysis of QA. The overall rating for the competency was a pass.

Uploaded by

api-239878826
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

Kressinimrtcomps

This document summarizes the results of an external beam IMRT planning competency evaluation for Andy Kressin from January 1, 2014 to December 8, 2014. Four evaluations were included in the analysis. The competency covered tasks related to imaging, contouring, treatment planning, and quality assurance. Most tasks were rated as satisfactory. Areas that received unsatisfactory ratings included accurately fusing image data sets together, optimizing and generating a concomitant boost plan, and observing IMRT QA and analysis of QA. The overall rating for the competency was a pass.

Uploaded by

api-239878826
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Results Summary - "External Beam IMRT Planning

Competency"

EASI Menu : Manage

Filter Your Responses


To analyze a subset of your data, you can add filters.
(Filters currently ON)
Evaluation Period from: 1/1/2014
Evaluation Period through: 12/8/2014
Evaluations for: Kressin, Andy
Filtered Responses: 4
TOTAL RESPONSES: 71

Select the external beam IMRT planning competency from the drop down menu below:
Response Response
Percent
Total

(Choice - One Answer Drop Down)


Prostate
(IMRT)

25.0%

Esophagus
(IMRT)

25.0%

H & N (IMRT)

25.0%

Brain (IMRT)

25.0%

Total Respondents:

Skipped this question:

Please assign each task a score of Satisfactory or Unsatisfactory.


Unsatisfactory in any essential task constitutes competency failure.
The student will repeat the competency at a later date.
(Rating Scale - Matrix)
1
Statistical Mode in BOLD Unsatisfactory

2
Satisfactory

0
N/A

Additional
Comment

Mean Percentage
[0-2]
Score

Discusses the plan


prescription with the
physician.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Loads the patient


imaging studies into the
planning computer.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Accurately fuses image


data sets together.

0.0% (0)

25.0% (1)

75.0% (3)

0.50

25.0%

Contours the appropriate


anatomy on the image
data set.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Successfully places the

isocenter using
simulation data.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Correctly generates
optimal beam angles for
specific anatomical area.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Generates plan with


appropriate energies.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Able to manipulate
ROI/PTV constraints in
the optimizer to obtain
an optimal plan.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Accurately optimizes and


generates a concomitant
boost plan.

0.0% (0)

50.0% (2)

50.0% (2)

1.00

50.0%

Accurately generates an
individual DVH or
composite DVH (for
correct # of fractions).

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Understands the concept


of prescribing to a point
vs. prescribing to a
volume and is able to
adjust the plan %
normalization as
needed.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Communicates
effectively with physician
for plan review and
makes changes as
requested.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Exports/Prints
appropriate plan data.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Accurately generates the


QA for the plan.

0.0% (0)

0.0% (0)

100.0% (4)

0.00

0.0%

Enters in correct
parameters for patient
chart.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Performs pretreatment
checks/calculations.

0.0% (0)

100.0% (4)

0.0% (0)

2.00

100.0%

Observes IMRT QA and


analysis of QA.

0.0% (0)

25.0% (1)

75.0% (3)

0.50

25.0%

Observes patient
treatment.

0.0% (0)

75.0% (3)

25.0% (1)

1.50

75.0%

OVERALL
COUNTS/MEANS:

59

13

1.64

81.9%

Overall rating:

Total Respondents:

Skipped this question:

(Rating Scale - One


Answer Horizontal)
Statistical Mode in BOLD

Additional Comments:

1
Fail

2
Pass

0.0% (0)

100.0% (4)

If applicable,
please specify
reason for failure

Mean Percentage
[1-2]
Score
2.00

100.0%

Total Respondents:

Skipped this question:

[If "Other" Competency, please specify type here]

(Open Ended - Comments Box)


Total Respondents: 4
Skipped this question: 0
Mean percentage score for all rating scale questions: 91.0%
(Each main question equally weighted)

Responses as of 12/8/2014 10:10:40 AM CT