0% found this document useful (0 votes)
124 views2 pages

Genset AMF Controller DKG-309

The DKG-309 is an automatic mains failure unit that monitors utility power and controls backup generator operation during power outages. It monitors generator parameters, controls starting and stopping, and provides protection functions. It has inputs and outputs for monitoring engine sensors and controlling relays. Event logging, telemetry via serial ports, and remote monitoring software allow local or remote operation and diagnostics.

Uploaded by

SAMEER
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views2 pages

Genset AMF Controller DKG-309

The DKG-309 is an automatic mains failure unit that monitors utility power and controls backup generator operation during power outages. It monitors generator parameters, controls starting and stopping, and provides protection functions. It has inputs and outputs for monitoring engine sensors and controlling relays. Event logging, telemetry via serial ports, and remote monitoring software allow local or remote operation and diagnostics.

Uploaded by

SAMEER
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DKG-309 AUTOMATIC MAINS FAILURE UNIT

DESCRIPTION
The DKG-309 is a comprehensive AMF unit for a single genset
standby or dual genset mutual standby operations.
In AUTOMATIC position, DKG-309 monitors mains phase
voltages and controls the automatic starting, stopping and load
transfer of the generating set in case of a mains failure and
once the generator is running, it monitors internal protections
and external fault inputs. If a fault condition occurs, the unit
shuts down the engine automatically and indicates the failure
source with the corresponding red led lamp and text.
The operation of the unit is controlled with front panel
pushbuttons. The LOAD TEST, TEST, AUTO and OFF
pushbuttons select the operating mode. Other buttons select
the display parameter scroll, alarm mute and lamp test
functions.
The DKG-309 provides a comprehensive set of digitally
adjustable timers, threshold levels, input and output
configurations and operating sequences. The unauthorized
access to program parameters is prevented by the program lock
input. All programs may be modified via front panel pushbuttons,
and do not require an external unit.
The fault conditions are considered in 3 categories as
Warnings, Loaddumps and Shutdown Alarms. Measured
values have separate programmable limits for warning and
shutdown conditions. The unit is able to initiate modem calls
and sending SMS messages in fault conditions.
Last 100 faults are stored in the event log file. The event log
includes not only the date-time information, but also a
comprehensive list of measured genset parameters at the time
that the fault has occurred.
The service request indicator lamp turns on at the expiration of
either engine hours or time limits.
It is possible to monitor and control the operation of the system
locally or remotely with the WINDOWS based RAINBOW
program.
The unit supports MODBUS protocol enabling communication
with PLCs and building management systems. The MODBUS
protocol is also supported through GSM and PSTN modems.
The unit is designed for front panel mounting. Connections are
made with 2 part plug and socket connectors.
The unit offers triple language support. Default languages are
English-Turkish and Chinese.

MEASUREMENTS
Generator Volts: L1-N, L2-N, L3-N
Generator Volts:
L1-L2, L2-L3, L3-L1
Generator Amps: L1, L2, L3
Generator total KW
Generator pf
Generator Frequency
Engine rpm (optional)
Mains Volts: L1-N, L2-N, L3-N
Mains Volts: L1-L2, L2-L3, L3-L1
Mains Frequency
Battery Voltage
Engine Coolant Temperature
Engine Oil Pressure
Fuel Level

FEATURES
Automatic mains failure
Engine control
Gas engine support
Engine idle speed control
Generator protection
Built in alarms and warnings
Remote Start operation available
Dual genset mutual standby operation
Load shedding, dummy load
Periodic maintenance request indicator
Built in daily / weekly / monthly exerciser
Event logging with time stamp and measurements
Statistical counters
Battery backed-up real time clock
Weekly operation schedule programs
Field adjustable parameters
RS-232 serial port
Firmware downloadable from serial port
Free MS-Windows Remote monitoring SW:
-local, and modem connection
-monitoring, download of parameters
-modem networking
GSM and PSTN modem support
GSM SMS message sending on fault
MODBUS communications
Blue color graphic LCD display (128x64 pixels)
User friendly graphic indicators
Triple language support
Customer logo display capability
Protected semiconductor digital outputs
Configurable analogue inputs: 3
Configurable digital inputs: 7
Configurable relay outputs: 2
Total relay outputs: 6
I/O expansion capability
Survives cranking dropouts
Sealed front panel
Plug-in connection system for easy replacement

STATISTICS
Following incremental counters provide statistics about past
performance of the generating set:
Engine Hours Run
Total KW-h
Engine Hours to Service
Time to Service
Number of Engine Cranks
Number of Genset Runs
EVENT LOGGING
The DKG-309 records last 100 events with date-time stamp
and a total of 18 measured parameters. Recorded events are:
-shutdown alarms, loaddumps and warnings
-periodic records
WEEKLY OPERATION SCHEDULE
In AUTO mode only, the unit offers the capability of defining a
weekly operation schedule. Programmable parameters allow
the genset to operate automatically only in defined time limits
of each weekday.
The internal battery backed-up real time clock allows precise
switching times.
DIGITAL INPUTS
The unit has 7 configurable digital inputs. Each input has
following programmable parameters:
-alarm type: shutdown / load_dump / warning / no alarm
-alarm polling: on engine running / always / on mains OK
-latching / non-latching operation,
-contact type: NO / NC
-switching: BAT+ / BATANALOG INPUTS
Engine analog inputs are provided for coolant temperature, oil
pressure and fuel level. Analog inputs connect to resistive
sender units to provide precise and adjustable protection. The
inputs have programmable sensor characteristics so that they
are suitable for any type and any brand of sensors.
RELAY OUTPUTS
The unit provides 6 relay outputs and 2 of them have
programmable functions, selectable from a list. Any function or
alarm condition may be output as a relay output.
Using two Relay Expansion Modules, the number of relays
may be increased to 22, 16 of them being volt-free contacts.

TELEMETRY AND REMOTE PROGRAMMING


The unit provides the user with large telemetry facilities via its
standard RS-232 serial port, connecting either to a PC, PLC or
a GSM or PSTN modem. It supports both RAINBOW and
MODBUS communication protocols. The standard PC software
offers local and modem operation capabilities as well as
modem networking feature.
The PC program is used for below purposes:
-parameter upload/download
-remote monitoring and control
-diagnostics and analysis
The MODBUS interface allows the unit to be integrated in
building management systems.

TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N)
Alternator frequency: 0-100 Hz.
Mains voltage: 0 to 300 V-AC (Ph-N)
Mains frequency: 0-100 Hz.
DC Supply Range: 9.0 to 30.0 V-DC
Cranking dropouts: survives 0 V for 100ms.
Typical Standby Current: 100 mA-DC
Maximum Operating Current: 200 mA-DC (Relay outputs open)
Generator/Mains Contactor Relay Outputs: 16 A / 250V
DC Outputs: 1A @ 28V
Charge excitation current: min 150mA @ 10 to 30 V-DC
Current inputs: from CTs, .../5A. Max load 0.7VA per phase.
Analog input range: 0-5000 ohms.
Serial port: RS-232, 2400 bauds, no parity, 1 bit stop
Operating temp.: -20C (-4F) to 70 C (158F).
Storage temp.: -40C (-40F) to 80 C (176F).
Maximum humidity: 95% non-condensing.
Dimensions: 165 x 125 x 48 mm (WxHxD)
Panel Cut-out Dimensions: 151x111 mm minimum.
Weight: 350 g (approx.)
Case Material: High Temperature ABS/PC (UL94-V0)
IP Protection: IP65 from front panel, IP30 from the rear
Conformity (EU directives)
-2006/95/EC (low voltage)
-2004/108/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)

DATAKOM Electronics Ltd.


Tel : +90-216-466 84 60
Fax : +90-216-364 65 65

http: www.datakom.com.tr
e-mail : [email protected]

You might also like