Vacuum System Parameters

The document provides specifications for a vacuum system including: - A total volume of 7 cubic meters that needs to be evacuated within 2 minutes to a working temperature of 50 degrees Celsius and end pressure of 8 mmHg. - A suggested vacuum pump is a two-stage water ring pump with an ultimate pressure of 25 Pa and power of 11 kW. - The complete system includes two root vacuum pumps in series (150 l/s and 600 l/s) and the water ring pump, along with a buffer tank, water/gas separator, control panel, and other vacuum components. - The layout of the system connects the various components and specifies their characteristics and functions within the vacuum system.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
254 views

Vacuum System Parameters

The document provides specifications for a vacuum system including: - A total volume of 7 cubic meters that needs to be evacuated within 2 minutes to a working temperature of 50 degrees Celsius and end pressure of 8 mmHg. - A suggested vacuum pump is a two-stage water ring pump with an ultimate pressure of 25 Pa and power of 11 kW. - The complete system includes two root vacuum pumps in series (150 l/s and 600 l/s) and the water ring pump, along with a buffer tank, water/gas separator, control panel, and other vacuum components. - The layout of the system connects the various components and specifies their characteristics and functions within the vacuum system.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

1-Vacuum System Parameters:

1- Total Volume is 7 m3.


2- Estimated evacuation time is 2 min.
3- Ambient temperature is 1 atmospheric pressure.
4- Working temperature is 50 degree C.
5- End pressure is 8 mmHg.
6- Processing tank volume is about 0.5 m3 (see the drawing).
7- Total Tanks volume is 5 m3.
8- Pump and flash tank will be located in separate room 40 meter far from
processing room.
9- Water ring vacuum pump is suggested (see attached specifications).
10- Always operation time is about an hour.
11- General Network pipe size is 2 (also can be modified according to the
pump characteristics and branches pipe size is .
12- Evacuated gases are just air.
2-We are looking for:
1. Revising Design and selecting of vacuum system.
2. Quotation for:
2.1: Water ring multistage pump.
2.2: Flash Tank (Suitable size).
2.3: Control Panel.
2.4: Any additional items.

3-Suggested System Characteristics:


The complete vacuum system as shown below consists of the following equipment:

- Two roots vacuum pumps in series and two stage water ring vacuum pump and the main
technical performance of JZJS type (JZP(C)2S(Y)541) are shown below :
Ultimate pressure 25 pa
Type of composed pumps:
Main pump ZJ 600 l/s (7.5 kW)
Intermediate pump ZJ-150 l/s (3 kW)
Fore pump 2 Stage water ring (11 kW)
3-1. Two stage water ring vacuum pump:

Water ring vacuum pump two - stage pumps in series with same shaft
Ultimate vacuum 25 Pascal
Attached power 11 kW
Inlet diameter 200mm
Outlet diameter 50mm

3-2. Intermediate Root vacuum pump JZ 150:

Partial pressure 0.05 pa


Pumping speed (l/s) 150
Required Power 3 kW
3-3. Main Root vacuum pump ZJP(C) 600

Partial pressure 0.05 pa


Pumping speed (l/s) 600
Power 7.5 kW
3-4. Water / gas separator
Inlet and exit ports 50 mm.
3-5. Buffer tank
Volume of the buffer tank (3 m3) to prepare for the vacuum process and to act as a
damper to absorb the high vacuum speed of the gases
With a blow down hole , the blanking cover of which can be opened when cleaning
between the pump set with large and small pouring vat.
3-6. Two vacuum relay.
3-7. Water pressure relay.
3-8. Check valves.
3-9. other vacuum facilities.

4- System Layout: