0% found this document useful (0 votes)
33 views

Mill Discharge Slurry Data

This document contains test data from 5 runs measuring the pressure drop across a tube transporting a slurry at various flow rates. The test data includes the tube dimensions, slurry properties, measured pressure drops, and calculated velocities and shear rates. The data was input into a software called Fathom which modeled the flow using Bingham plastic and power law models. Graphs compare the test data and model predictions of pressure drop versus flow rate.

Uploaded by

Franco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Mill Discharge Slurry Data

This document contains test data from 5 runs measuring the pressure drop across a tube transporting a slurry at various flow rates. The test data includes the tube dimensions, slurry properties, measured pressure drops, and calculated velocities and shear rates. The data was input into a software called Fathom which modeled the flow using Bingham plastic and power law models. Graphs compare the test data and model predictions of pressure drop versus flow rate.

Uploaded by

Franco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 12

Tube Diameter

Tube Length
Slurry Density
Gravity

0.01
0.75
1400
9.81

m
m
kg/m3
m/s2

Test Data

Run #
1
2
3
4
5

Flow rate
m3/h
0.003
0.015
0.025
0.05
0.1

Calculated Data

Pa
25000
36000
44000
53000
60000

Flow rate
m3/sec
8.333E-07
4.167E-06
6.944E-06
1.389E-05
2.778E-05

Velocity
m/sec
0.0106
0.0531
0.0884
0.1768
0.3537

Jm
m/m
2.43
3.49
4.27
5.15
5.82

Data Input to Fathom


Fathom Results
Shear
Shear
Rate
Stress (Tau)
8v/D
PD/4L
Vol. Flow
1/s
Pa
m3/sec
8.5
83.3
8.33E-07
42.4
120.0
4.17E-06
70.7
146.7
6.94E-06
141.5
176.7
1.39E-05
282.9
200.0
2.78E-05

Fathom Results
Bingham Power Law
Plastic
dP Stag. dP Stag.
Pa
Pa
34,106
24,818
38,898
37,598
41,825
42,897
48,033
51,300
58,887
61,350

Pressure Drop vs. Flow


70,000
60,000

dP (Pa)

50,000
Test Data
Bingham Plastic
Power Law

40,000
30,000
20,000
10,000
0
0

0.02

0.04

0.06

Flow (m3/h)

0.08

0.1

0.1

Flow

Test Data
Bingham Plastic
Power Law

0.08

0.1

0.12

Tube Diameter
Tube Length
Slurry Density

0.364 in
2.5 ft
87.4 lbm/ft3

Test Data

Run #
1
2
3
4
5

Flow rate
gpm
0.013
0.066
0.11
0.22
0.44

Calculated Data

psid
3.6
5.2
6.4
7.7
8.7

Flow rate
ft3/s
0.000029
0.000147
0.000245
0.000490
0.000980

Velocity
ft/sec
0.0401
0.2035
0.3391
0.6783
1.3566

Jm
ft/ft
2.37
3.43
4.22
5.07
5.73

Data Input to Fathom


Fathom Results
Shear
Shear
Rate
Stress (Tau)
8v/D
PD/4L
Vol. Flow
1/s
psi
gpm
10.6
0.011
0.013
53.7
0.016
0.066
89.4
0.019
0.11
178.9
0.023
0.22
357.8
0.026
0.44

Fathom Results
Bingham Power Law
Plastic
dP Stag. dP Stag.
psid
psid
4.927
3.61
5.605
5.43
6.016
6.173
6.884
7.348
8.396
8.746

Pressure Drop vs. Flow


10
9
8

dP (psid)

7
Test Data
Bingham Plastic
Power Law

6
5
4
3
2
1
0
0

0.05

0.1

0.15

0.2

0.25

Flow (gpm)

0.3

0.35

0.4

0.45

0.

s. Flow

Test Data
Bingham Plastic
Power Law

0.3

0.35

0.4

0.45

0.5

You might also like