100% found this document useful (1 vote)
3K views2 pages

Pile Set Calculation

This document contains calculations to determine the number of blows and allowable penetration per blow required to set a 200mm x 200mm reinforced concrete pile driven into clay soil using a freely falling drop hammer. It uses modified Hilley's formula and references data from a Reinforced Concrete Designer's Handbook. The calculations determine the temporary elastic compression factor is 1.70464986 and the required number of blows is 0.160328. The allowable penetration per last 10 blows is 24.95mm.

Uploaded by

qoci5ko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views2 pages

Pile Set Calculation

This document contains calculations to determine the number of blows and allowable penetration per blow required to set a 200mm x 200mm reinforced concrete pile driven into clay soil using a freely falling drop hammer. It uses modified Hilley's formula and references data from a Reinforced Concrete Designer's Handbook. The calculations determine the temporary elastic compression factor is 1.70464986 and the required number of blows is 0.160328. The allowable penetration per last 10 blows is 24.95mm.

Uploaded by

qoci5ko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Title : abc

PILE SET CALCULATION FOR 200 mm x 200 mm RC PILE


Calculation

Reference

C1

Job Ref:
Date
Time :
Designed By:
Checked By :

PILE SET CALCULATION FOR 200 mm x 200 mm RC PILE (WORKING LOAD = 450 kN AT 27 m
Set Calculation For Hammer Driven Piles Using Modofoed HILLEY's Formula
Based on Table 193, Reinforced Concrete Designer's Handbook - 9th Edition

Hammer Used
Pile Size
Pile Design Working Load
Estimated Pile Penetration Length, L
Assumed Type of Driving
Weight of Hammer, w
Factor of Safety, Fs
k Factor
Weight of Helmet, Dolly & Stationery Parts
Type of Soil
Proposed Hammer Drop, H

=
=
=
=
=
=
=
=
=
=
=

Freely Falling Drop Hammer


200
mm
450
kN
27
m
Medium
30
kN
2.5
0.5
5
kN
Clay
450
mm

Self Weight of Pile, Wp

=
=

0.2 x 0.2 x 27 x 24
25.92
kN

Combined All Weight, P

=
=

25.92 + 5
30.92

Settlement Load, Wm

=
=

[450 + 30.92] / 0.5


961.84
kN

Driving Pressure, p

=
=

961.84 / [200 x 200]


kN/mm2
0.024046

kN

Temporary Elastic Compression Factor


c1 (For Pile)
c2 (For Helmet and Dolly)
c3 (For Ground)

= 0.044pL
= 0.56p
= 0.44p

= 0.044 x 0.024046 x 27
= 0.56 x 0.024046
= 0.44 x 0.024046

=
=
=

0.02856665
0.01346576
0.01058024

Therefore, The Temporary Elastic Compression Factor, Ac


= 0.5 x 64.8 x [0.02856665 + 0.01346576 + 0.01058024]
=
1.70464986
Efficiency of Blow
= P/w = 30.92 / 5
Table 193

e =

1.030667

1.0

0.53

Hiley Formula (Modified)


Settlement Load, Wm

= [(W x H x e x n) / (1 + ac x n)] + W + P

Numbers of Blows, n

= [Wm - w - P] / [(w x H x e) - (Wm - w - P) x ac]

Wm - w - P

= 961.84 - 30 - 30.92

900.92

wxHxe

= 30 x 1.0 x 450 x 0.53

7155

Therefore Numbers of Blows, n

= 900.92 / [ 7155 - (900.92 x 1.70464986)]


=
0.160328

Therefore, The Allowable Penetration (mm) Per Last 10 Blows During Pile Setting
s = 10/(n x Fs) = 10 / (0.160328 x 2.5)
=
24.95 mm

Testing
13-May-15
16:08
Se TH
Ir. Se Thiam Hai
Output

Title : abc

Reference

PILE SET CALCULATION FOR 200 mm x 200 mm RC PILE


Calculation

C1

Job Ref:
Date
Time :
Designed By:
Checked By :

Testing