Low Temperature Vessels Block Insulation: Plate 4-810
The document describes insulation techniques for low temperature vessels and equipment below 0°C. It involves using multiple layers of rigid block insulation with contraction joints filled with blanket insulation to absorb movement. Details are provided on securing the insulation with bands and installing vapor barriers.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
66 views1 page
Low Temperature Vessels Block Insulation: Plate 4-810
The document describes insulation techniques for low temperature vessels and equipment below 0°C. It involves using multiple layers of rigid block insulation with contraction joints filled with blanket insulation to absorb movement. Details are provided on securing the insulation with bands and installing vapor barriers.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Vessels, Tanks, and Equipment
Plate 4-810
Low Temperature Vessels Block Insulation
10 A
12
13
12 C
3 4
1 B 5 11
15
14
2011 MICA
Low temperature below 0C
(32F) installations such as refrigerant storage tanks, and process equipment may require multiple layer block construction, securement of the insulation with bands and the design of contraction joints. Contraction joint is filled with blanket insulation to absorb linear contraction of vessel when at operating temperatures. (Material is compressed tightly into joint.)
Detail A Contraction joint (typical).
6. Jacketing.
Detail B Double layer staggered joint construction.
7. Bands. (Provide for contraction).
Detail C Joint sealant application.
8. Head insulation shown secured with a floating ring of
cable fastened to another ring of cable under head flange. (See Detail A, also Plate 4-620, Detail A & B).
vapor resistance, and low coefficient of friction required). 12. Vapor retarder sealant (if required). 13. Vapor retarder jacket. 14. Damp-proof course in between layers. 15. Bottom course bedding sealant to prevent flood water ingress. (Bedding sealant must serve as a vapor retarder.) See Plate 4-660.