MaltaRackLayout111912 v8 Update

The document provides details on equipment layout and power requirements for a data center cabinet including required outlets, fiber, slots and cables per cabinet as well as equipment specifications and power needs.

Uploaded by

Dinh Tran Hiep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views

MaltaRackLayout111912 v8 Update

The document provides details on equipment layout and power requirements for a data center cabinet including required outlets, fiber, slots and cables per cabinet as well as equipment specifications and power needs.

Uploaded by

Dinh Tran Hiep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REQUIRED PDU OUTLETS/CABINET

REQUIRED FIBER/CABINET

REQUIRED SLOTS/CABINET

REQUIRED CABLES/CABINET

STANDARD PRACTICE

IBM 3490 Tape Drives (1) (1) 30 Amp & (1) QUAD 110v

KVM SLOT U-24


KVM KEYBOARD/MONITOR SLOT U-23
KVM POW ER TO PDU x-A PLUG 10 & x-B PLUG 10
KVM MONITOR/KE YBOARD T O PDU x-A PLUG 9
KX2-432 PP PORT 1 TO KVM PORT 1
PP PORT 2 TO KVM PORT 2
PDU x-A PP PORT 3
PDU x-B PP PORT 4

EACH RARITAN PDU G ETS A NETWORK CONNECTION.


Revised: 10/10/12

STRATUS EQUIP. GOES TO STRATUS PDU.


THIS PDU IS AN L6/20 PLUG.

Share Patch Panel


Un-Shared Patch Panel

EMC SUPPLIED
POW ER CABLES

(6/4/25/17)

(0/0/0/0)

(4/0/36/2)

(0+2/0/0/0)

(14+2/0/41/27)

(0/0/3/0)

Share Patch Panel

Un-Shared Patch Panel

(26+2/2/26/27)

(5+2/8/14/9)

(10+2/0/21/9)

F an
F an

(1)

F an

(1)

Plugs into to Raritan PDU Plugs into Server


IEC320 C13
IEC320 C14

Plugs into to Raritan PDU Plugs into Server


IEC320 C13
IEC320 C14

CPU
CPU

24"W 75"H 43"D

CPU

25"W 80"H 43"D

31"W 83"H 43"D / 45U

24"W 86"H 41"D / 45U

34"W 83"H 43"D / 45U

24"W 86"H 43"D / 45U

Plugs into to Raritan PDU Plugs into Server


IEC320 C13
IEC320 C14

24"W 84"H 40"D / 45U

24"W 84"H 40"D / 45U

24"W 84"H 40"D / 45U

(1) Quad 110v


FOR PA-5050

2
1

(0/0/16/16)

EMC SUPPLIED PDU

EMC SUPPLIED PDU

EMC SUPPLIED PDU

EMC SUPPLIED PDU

R1-4 VNX2
(22/16/22/26)

(10/0/22/22)

24"W 84"H 40"D / 45U

(2) QU AD 110v
The Modems are placed on
top of the owning Router

Share Patch Panel

Share Patch Panel

(12+2/0/38/10)

(0/0/0/2)

(1/2/0/2)

(6/0/0/19/2)

(8/16/26/26)

(16+2/0/19/15)

Un-Shared Patch Panel

(21+2/10/18/18)

F an

100 B0/C0 IBM CHPID3

110 A1-D1-B1-C1 NIC 101 VLAN954 IP 10.50.129.45


170 A1-130, A2-131, A3-132, A4-133
150 J00-B0/C0 MF BACKBONE IP: 192.1`00.100.101
150 J01-C1/B1 MF BACKBONE IP: 192.100.100

(2) 30 Amp 2 phase


12 AMP CIRCUITS
24"W 86"H 43"D

(2) 30 Amp 2 phase


12 AMP CIRCUITS
24"W 86"H 43"D

160-161-162-163-164-165-166-167
190 J00-B0/C0 MF FIREWALL A4 G6/43-2
190 J01-C1/B1 MF FIREWALL A2 G8/13-1
IP: 172.19.185.172/173
1F0-1F1-1F2-1F3-1F4-1F5-1F6-1F7

30"W 76"H 40"D

30"W 76"H 40"D

Plugs into to Raritan PDU


IEC320 C14

Plugs into to Raritan PDU Plugs into Server


IEC320 C13
IEC320 C14

Plugs into Server


IEC320 C13

34"W 83"H 43"D / 45U

CPU

24"W 75"H 40" 38"D


(2) 50 Amp 3 phase

24"W 75"H 40" 38"D

31"W 76"H 65"D

(2) 50 Amp 3 phase

(2) L6-20
Plug: 240-16 AMP for

6500 Switch

HBL2621 is equivalent to NEMA L6-30P

24"W 75"H 38"D / 45U

Plugs into to Raritan PDU


IEC320 C14

Plugs into Server


IEC320 C13

24"W 75"H 38"D / 45U