Blue Solar Charge Controller MPPT: Accepted
Blue Solar Charge Controller MPPT: Accepted
5
Module:
In series:
Total PV power:
Module temperature:
Controller:
System voltage:
Cable length, Module to MPPT *
* One way length
Max. input voltage
Max. PV voltage @ min. temperature
Min. input voltage @ MPP
Min. PV voltage @ max. temperature
Max. output current
Max. current @ MPP min. temp.
Max. current @ MPP max. temp.
Solar module configuration
17
3
Parallel:
4500 Wp
Min.
25
0 C
0
Max.
70 C
8
4
5m
Volt
Cross-section:
6.0 mm
150 V
143.5 V
49.0 V
85.5 V
85 A
85.0 A
* Power limiting @ low temp.
75.8 A
Accepted
Manufacturer
[name]
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Custom: 1XYZ
Custom: 2XYZ
Custom: 3XYZ
Custom: 4XYZ
Custom: 5XYZ
Custom: 6XYZ
Custom: 7XYZ
Custom: 8XYZ
Custom: 9XYZ
Custom: 10XYZ
Type
[name]
SPM30-12
SPM50-12
SPM80-12
SPM100-12
SPM130-12
SPM190-24
SPM300-24
SPP30-12
SPP40-12
SPP50-12
SPP75-12
SPP80-12
SPP100-12
SPP140-12
SPP250-20
SPP280-24
SPP300-24
1ABC
2ABC
3ABC
4ABC
5ABC
6ABC
7ABC
8ABC
9ABC
10ABC
Coefficient support:
If you have the voltage temperature coefficient in mV/C, here is how to change it to %/C
Write the Voc value in Volt:
24.1
Write the coefficient value in mV/C:
-77
The coefficent value in %/C is now:
-0.320
If you have the current temperature coefficient in mA/C, here is how to change it to %/C
Write the Isc value in Ampere:
8.72
Write the coefficient value in mA/C:
4.7
The coefficent value in %/C is now:
0.054
nge it to %/C
V
mV/C
%/C
nge it to %/C
A
mA/C
%/C
Power
[W]
30
50
80
100
130
190
300
30
40
50
75
80
100
140
250
280
300
50
75
100
125
150
175
200
225
250
275
Vmpp
[V]
18
18
18
18
18
36
36
18
18
18
18
18
18
18
30
36
36
30.89
35.5
40.2
35.5
35.5
35.5
35.5
35.5
35.5
44.3
Impp
[A]
1.67
2.78
4.45
5.56
7.23
5.44
8.06
1.72
2.22
2.85
4.17
4.6
5.75
8.05
8.33
7.78
8.33
8.9
6.46
6.46
6.46
6.46
6.46
6.46
6.46
6.46
5.54
Voc
[V]
22.5
22.2
22.3
22.4
22.4
43.2
45.5
22.5
22.5
22.2
22.2
21.6
21.6
21.6
36.01
44.06
44.1
38.2
45
48
45
45
45
45
45
45
53
Isc
[A]
2
3.16
4.96
6.53
8.49
5.98
8.56
1.85
1.85
3.09
4.64
5.06
6.32
8.85
9.4
8.26
8.85
9.52
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
5.86
V temp coef
[%/C]
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.34
-0.35
-0.35
-0.34
-0.34
-0.31
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.33
-0.25
I temp coef
[%/C]
0.037
0.037
0.037
0.037
0.05
0.037
0.037
0.045
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.045
0.045
0.047
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.03
Art.Nr.
SPM010301200
SPM010501210
SPM010801210
SPM011001210
SPM011301210
SPM011902400
SPM013002400
SPP010301200
SPP020401200
SPP010501210
SPP020751200
SPP010801210
SPP011001210
SPP011401200
SPP022502400
SPP012802400
SPP023002400
Manufacturer
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Victron Energy
Type
BlueSolar MPPT 75/15
BlueSolar MPPT 75/50
BlueSolar MPPT 100/15
BlueSolar MPPT 100/30
BlueSolar MPPT 100/50
BlueSolar MPPT 150/35
BlueSolar MPPT 150/70
BlueSolar MPPT 150/85
12
12
12
12
12
12
12
12
System Voltage
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
N.A.
N.A.
24
36
48
24
36
48
24
36
48
DATA:
Location:
Module info:
0 C min
70 C max
132.3 V Voc @25C
108.0 V Vmpp @25C
44.25 A Isc PV@25C
41.65 A Impp PV @25C
93.71 A Impp output @25C
-0.340 %/C Temp. Coeff. Voc
-0.450 V/C Temp. Coeff. Voc absolute
0.045 %/C Temp. Coeff. Isc
0.020 A/C Temp. Coeff. Isc absolute
Regulator info:
Voltage drop:
RESULTS:
Temperature
0 C
5
10
15
55
60
65
70 C
Voc max.
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
150.0 V
Temperature
0 C
5
10
15
55
60
65
70 C
Ibat max.
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
85.0 A
Impp PV max.
41.15 A
41.25 A
41.35 A
41.45 A
42.25 A
42.35 A
42.45 A
42.55 A
c absolute
(Col 18 )
System Voltage
48 V
48 V
48 V
48 V
48 V
48 V
48 V
48 V
81.10
79.36
77.60
75.84
A
A
A
A
118.8
116.6
114.3
112.1
V
V
V
V
94.5
92.3
90.0
87.8
V
V
V
V
92.1
89.9
87.7
85.5
V
V
V
V
History
1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 -
Added new solar modules, and now 10 additional modules can be added instead of 3.
Added a small calculation on the 'Modules' TAB to help when temperature coefficiences a
Added new solar modules, voltage drop correction and an option to rise the cell temperat
Inserted 4 new regulators and 2 more custom module.
Inserted 4 languages @ updated not applicable (N.A.) voltages for 75/15, 75/50 & 100/15
Changed texts and Module temperature window.
Power reduction comment set @ highest temperature.
Reduced output current to maximum output current at low & high temperatures. Now a s
Inserted BlueSolar MPPT 100/15
Inserted custom module
First version
& high temperatures. Now a system will show 'power loss' only wenn the output current exceeds the max. at lo