100% found this document useful (1 vote)
842 views

ELC-131D - User Manual

ELC-131D Manual

Uploaded by

Andrey Ps
Copyright
© © All Rights Reserved
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
842 views

ELC-131D - User Manual

ELC-131D Manual

Uploaded by

Andrey Ps
Copyright
© © All Rights Reserved
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 16
ELC-131D DUAL DISPLAY L/C/R METER USER MANUAL ESCORT Escort Instruments Corporation NO. 6, Alley 6, Lane 45, Pao-Hsin Road Hsin Tien, Taipei, Taiwan TEL: (02) 913-1326~8, (02) 918-0320~2 FAX: 886-2-9183929, 886-2-913-1329 DUAL DISPLAY LICR METER OPERATOR'S _ MANUAL Table of Contents Introduction ... Front Panel Ilustratio LCD Display Special Indi PEPE weer ition Characters Safety Information 6 Waring .. 7 Re Bef General Specification 8 Accessories . 9 Electrical Specification .. p. 10 Rew A How to Operate 1S Software Operating Instructions 19 Te COLMA Fuse and Battery Replacement .. . 26 Introduction ‘This 10,000-count L/C/R hand held meter is a special microprocessor-controlled meter for measuring functions of inductance, capacitance and resistance. Extremely simple to operate, the instrument not only takes absolute parallel mode measurements, but is also capable of series mode measure- ment. The meter provides direct and accurate measurements of inductors, capacitors and resistors with dual testing frequencies of 120Hz and 1kHz. It is auto and manual ranging selectable. When not in use for more than five minutes with power on, the meter will automatically shut off to prolong battery life. Front panel pushbuttons maximize the convenience of function and feature selection such as data hold; maximum, minimum and average record mode; relative mode; tolerance sorting mode; frequency and L/C/R selection. A tilt stand provides position flexibility for viewing and operating the meter. While single 9V battery operation is standard for the meter, a DC 12V power adaptor can also be used as an optional power input. Front Panel Illustration . LCD display |. IkHz/120Hz selection button . Dissipation and quality factor selection button . Relative mode and calibration selection button . Tolerance mode selection button 12, Input terminals and sockets . DC 12V adaptor inputs . Power on/off button Data hold; Maximum, Minimum and Average reading selection button, . Range selection button . Inductance, Capacitance and Resistance function selection button : aa s “RE GP GQ @: 2 tn TS 4S! es oe & hos FP oon osrar i wren 12 a = . mpinpF : . iH: Indicates the battery power is weakening . DH: Data hold annunciator . Tol : Tolerance mode annunciator | 1% 5% 10% : Tolerance sorting (percent) annunciator LCD Display Illustration . Auto: Autoranging indicator “MN: Beeper tone indicator for tolerance mode LCR :L, Cor R function annunciator MAX AVG MIN : Recording mode annunciators . MAX : Maximum reading annunciator . AVG: Average reading annuciator MIN: Indicates the minimum reading . REL: Relative mode annunciator . D Dissipation factor annunciator . 999 — : Secondary display . % — : Tolerance (percentage) annunciator . Q : Quality factor annunciator . IkHz. : Frequency annunciator . 120Hz : Frequency annunciator . MkQ. : Resistance (Ohm) annunciator . mH : Inductance (Henry) annunciator Capacitance(Fara) annunciator 12 348 9 190 cH 5|6| 7 AUTO! MAX] AVG] MIN o hm LCR REl me TOL Te 5% 19% rune eet DOOD 44.4. Nous Special Indication Characters rt OPn PAL SEr CAL FUSE Indicates short connectors : Indicates open connectors : Indicates parallel mode : Indicates series mode : Indicates calibration mode Indicates damaged or open fuse Safety Information ‘This manual contains information and warnings which must be followed to ensure safe operation as well as to maintain the meter in a safe condition. © This meter is for indoor use, altitude up to 2,000 m. © The meter is safety-certified in compliance with EN61010(IEC 1010-1) Installation Category II SOV, Pollution Degree 2 environment, ‘© Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired ‘* The power for the meter is supplied by a single standard 9V battery, But also a line operation is possible using a 12V AC to DC adaptor. If a power adaptor is selected, please be sure to use with the one which fulfilled the safety requirements of a relevant TEC standard *Note: The CPU of the meter can self-detect if its fuse is either open or damaged. In this case, the LCD will display the symbol “ FUSE” and an audible beep will sounds continuously, warning the user to replace the old fuse to maintain the accuracy of measurement. While replacing the fuse, the power of the meter must be completely shut off. WARNING ‘When measuring in-circuit components, firsts de-energize the circuits before connecting to the test leads, ‘The warnings and precautions should be read and well understood before the instrument is used. The must be carefully observed during use. This instrument is recommended to be used by a suitably trained and competent person AWARNING identifies conditions and actions that pose hazards) to the user; a CAUTION identifies conditions and actions that may damage the transduce”. Intemational electrical symbols used are explained in Table 1 — DC - Direct Current Ground a Double Insulation ‘See Explanation in the Manual 4 Table 1. Intemational Electrical Symbols ection IIT General Specifications Parameters Measured : L/C/R, D/Q Measurement Circuit Mode : 1) Capacitance/Resistance Measurement— Defaults to parallel mode for all ranges + : Parallel measured mode 2) Inductance Measurement Defaults to series mode for all ranges —~—-: Series measured mode Both Series and Parallel mode data can be obtained through simple key operation (See page 23) Displays : CIR : Max display 9999 except 10m(120Hz), ImF(1kHz) measurement ranges with max display 1999 D/Q_ : Max display 999 (AUTO RANGE) Measurement Terminals : 2 terminals with sockets Ranging Mode: Auto & manual Test Frequency: 1kHz & 120Hz Freq Accuracy = +0.01% (1k#Hz = 1008.06Hz; 120, Hz = 122.07Hz) Measurement Rate: 1 measuremenU/second, nominal Test Signal Level: 0.9 Vrms approx. Response Time —_: Approx. | second/DUT (device under test) (@ manual range) Temperature Coefficient : 0.05 x (Specified Accuracy)/°C (0°C-<18°C or 28°C -50°C) Operation ‘Temperature : 0°C to 40°C; 0 - 70% RH. Storage Temperature — : -20°C to +50°C; 0 - 80% RH Power Requirements 1) Battery : DC 9V Battery 2) Ext. DC Adaptor : DC 12Vmin - 15Vmax (LOAD ‘SOmA min) Low Battery Indication : Approx. 6.8V Power Consumption: Approx. 40 mA; 0.3mA @Auto Power-off Protective Fuse 1 0.1A fast-blow 250V AC (Please refer to Safety Information) Auto Power-Off Time: Approx. 5 mins. Dimensions : 37 mm(H) x 90 mm(W) x 192(L) Weight 2 390g ACCESSORIES Standard accessories: 1. Test alligator clips(pair): it is different to IEC requirements. 2. DC 9V Battery. 3. Fuse: 0.1 A/250V AC fast blow. 4. User manual. Optional accessories: 1. EH 80Y: Holster: 2. 12V(min) ~ 15V(max)/Load 50mA min DC power Adaptor EASO0: AC120V EASS: AC 240V Electrical Specifications All accuracies are @23C°+5C°; < 75% R.H. Resistance Range Max Accuracy Specified Display | ‘Test Freq.120Hz | ‘Test Freq.kHz Note 10MQ}9.999MQ, 42% + 8 counts) | 2% + 8 counts) *(note 3) *(note 3) | Alet open cal. IMQ_ [999.9k02| 40.5% + 5 counts) | 1(0.5%+5 counts) | after open cal. 100K | 99.99KO|30.5% + 3 counts) |(0.5%+3 counts)[__ — 10K | 9.9992] 0.5% + 3 counts) [4(0.5%643 counts) | _ — 1kQ 999.902 [540.5% + 3 counts) [3(0.5%43 counts) | _— 100Q 99.990 |-H0.8% + 5 counts) [2(0.8%645 counts) | alter short cal 10Q. 9.999Q. | +1.2%+ 8 counts) |4(1.2%+ 8 counts)} afier short cal Notes: L. This specification is based on the measurement performed at the test socket. 2. Dut & Test lead to be properly shielded to GND (DC “.”) if. necessary. 3. This specification is based on internal power (battery) operation. Capacitance Test Freq. 12082 ' Max ‘Accuracy Specified ange | Display Ce DF Note omg [59m | 5% +5 cout) | 210% #100/Cx +S cous) | aftr 1OmF | note 4_| (DF<0.1) (F<0.1) short cal, “H(1% + 5 counts) | 40% + 100ICx + 5 count) | ater 1000HF| 999.90 | (DF<0.11 (DF<0.1) shot cal H0.7%43 counts)| 0.7% +100/Cx +5 counts) 1OOHF |99.99UF | (DF<0.5) (DF<0.5) —_ 073 counis)| 10.7% +1001Cx +5 cous) 1OpF |9.999HF | (DF<0.5) (DF<0.5) can H0.1% 43 counis)| 10.7% +100/Cx +5 counts) 1000nF | 999.9nF } (DF<0.5) (DF<0.5) _ H0.1%45 counts)| 40.7% +100/Cx +5 counts) | afier 100nF }99.99nF | (DF<0.5) (DF<0.5) open cal. Hit + 5 coms) | HO% +100/Cx #5 coms) | after 10nF |9.999nF | (pF<0.1) (DF<0.1) open cal. Test Freq. 1kHz Max ‘Accuracy Specified Range | Display Cx* DF ‘Note -0.995mF |:15%+ 5 counts) | 410%+100/Cx +5 counts) | afer 1000HF| note 4 | (DF<0.1) (DF«0.1) short cal. Fiver 5 cous) | Has T0OC + 5 counts) | aller LOOpF | 99.99HF | (DF

You might also like