0% found this document useful (0 votes)
52 views

INS - Phased Array Pipework Inspection PDF

This document discusses phased array pipework inspection as a replacement for radiography. It can detect cracks, lack of fusion, lack of penetration, and slag inclusions. PAUT allows simultaneous collection of ultrasonic data from multiple angles in one pass at a rate of 15-20 butts per shift. Data analysis software allows experienced operators to interrogate welds from multiple orientations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views

INS - Phased Array Pipework Inspection PDF

This document discusses phased array pipework inspection as a replacement for radiography. It can detect cracks, lack of fusion, lack of penetration, and slag inclusions. PAUT allows simultaneous collection of ultrasonic data from multiple angles in one pass at a rate of 15-20 butts per shift. Data analysis software allows experienced operators to interrogate welds from multiple orientations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Phased Array Pipework Inspection

Oceaneering offers fully code compliant Phased


Array Ultrasonic Testing (PAUT) as a replacement to
on-site radiography. Developments in construction
codes have allowed PAUT to be used as a direct
replacement to Radiography on piping butt
welds to meet the quality control requirements of
ASME B31.3 and B31.1 and numerous European
standards. PAUT can be worked towards both
workmanship and Engineer Critical Assessment
(ECA) acceptance criteria, with data being suitable
for accurate sizing and defect characterization.

Detectable Defects
Cracks
Lack of Fusion
Lack of Penetration
Slag Inclusions
Porosity

PAUT enables reduced inspection time by


simultaneously collecting multiple angle ultrasonic
data in a one pass scan from either side of the
weld. Typical inspection rates are between 15-20
butts per shift. By ensuring accurate scan plans and
specifically designed techniques all construction
defects are readily detected, sized and sentenced
accordingly.

10/12

www.oceaneering.com

Phased Array Pipework Inspection


Data Analysis

Advantages

Sophisticated analysis software allows


experienced operators to interrogate welds from
multiple orientations including a comprehensive
evaluation of the weld root, fusion face and weld
toes.

Radiation free ultrasonic technique


Welds from 3/4 inch in diameter up to flat plate
may be inspected.
Wall thicknesses from 4mm. (N.B. Wall
thickness below 8mm may require a trial /
validation period.)
Independent from site utilities due to battery
operation and irrigation system
Rapid inspections with digital recording of data
Digitally encoded scanning for accurate sizing
Highly sensitive to fusion face flaws
Free viewing software available to allow the
client to review inspection data
ASME and European code compliant

Piping Construction Codes


ASME B31.3 code case 181.2, which permits
the use of PAUT on wall thicknesses >25mm
to a fracture mechanics sentencing criteria.
The sentencing for this code case is based
on a fracture mechanics module and requires
qualification.
B31.1 and code case 179, which together
permits the use of PAUT on all thicknesses.
The sentencing for this code is based on
workmanship criteria and does not specifically
require qualification.
BS EN ISO 17640: 2010 - Techniques, testing
levels and assessment for non-destructive and
ultrasonic testing of welds
BS4515: 1-2004 Specification for welding of
steel pipelines on land and offshore. Carbon
and carbon manganese steel pipelines. PAUT
allowable with client dispensation.
BE EN ISO 13588 - Non-Destructive Testing
of Welds - Ultrasonic Testing - use of Semiautomated PA

Limitations
Surface preparation is required to allow the
collection of quality data
100mm of radial and axial clearance is
required for scanner fitment (NB small bore
scanner available for restricted access
scanning.)