This document provides an example design of a reinforced concrete non-load bearing shear wall. Key details include: - The wall is designed to resist seismic shear forces up to 350 kips - #5 bars spaced at 12 inches are designed as horizontal shear reinforcement - #10 bars in two layers with 3 inch clear spacing are designed as flexural reinforcement - #4 closed ties are used to enclose the tension reinforcement

Uploaded by

Muhammad Faris
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
782 views

Design Examples Shear Walls

This document provides an example design of a reinforced concrete non-load bearing shear wall. Key details include: - The wall is designed to resist seismic shear forces up to 350 kips - #5 bars spaced at 12 inches are designed as horizontal shear reinforcement - #10 bars in two layers with 3 inch clear spacing are designed as flexural reinforcement - #4 closed ties are used to enclose the tension reinforcement

Uploaded by

Muhammad Faris
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Design examples

Example 1: Design of reinforced concrete non-load bearing shear wall.

Design code: ACI 318-05


Design data:
Seismic shear force: (service load)
Roof: Vr = 100 kips
4th floor: V4 = 75 kips, ,
3rd floor: V3 = 50 kips
2nd floor: V2 = 25 kips
Floor height: H = 15 ft
Length of wall: lw = 18 ft
Width of wall: h = 10 in
Concrete strength: fc' = 4000 psi
Yield strength of steel: fy = 60 kis

Assumption:
1.out-of-plan moment is neglectable.

2.The wall is an exterior wall.

Requirement:
Design reinforcement for shear wall

Solution:
Maximum shear occurs at load combination: 1.2D+1.4E+1.0L
Calculate maximum vertical and shear force at first floor
Maximum factored shear: Vu = 1.4 (100+75+50+25) = 350 kips
Check maximum shear strength permitted
Assume effective depth, d = 0.8 (18) = 14.4 ft
Strength reduction factor,

= 0.75

Vn = 10 fc' h d = 819 kips

> 350 kips O.K.

Critical section for shear at smaller of 18 ft/2 = 9 ft , H/2 = 7.5 ft


Calculate factored overturning moment and weight of wall at critical section
Mu = 1.4 [100 (60-7.5)+75(45-7.5)+50(30-7.5)+25 (25-7.5)] = 13130 ft-kips
Nu = (0.15)(10/12)(18)(60-7.5) = 118.1 kips
Calculate shear strength of concrete:

Vc = 0.75 [3.3 fc' h d + Nu d/ (4 lw)] = 288.2 kips


Mu/Vu - lw/2 = 28.5 ft

Vc = 0.75 { 0.6 fc' + lw ( 1.25 fc' + 0.2 [Nu/(lw* h)]) /( Mu/Vu - lw/2)} h d = 163.8 kips
Or Vc = 0.75 (2 fc' h d) = 163.9 kips

Use

Design horizontal shear reinforcement:


Vs = Vu - Vc = 186.1 kips
Use #5 bar in one layer, area of reinforcement, Av = 0.3 in2.
Spacing: S = Av fy d /Vs = 12.6 in, Use 12" O.C.

Check maximum spacing: (18x12)/5 = 43 in, 3 (10) = 30 in, or 18 in

O.K.

Check minimum reinforcement: t = 0.3 in2 / (12x10) = 0.0025 O.K.


Design vertical reinforcement:

l = 0.0025 + 0.5 (2.5 - hw/ lw )( t - 0.0025) = 0.0025


Use l = 0.0025
Area of reinforcement: Av = 0.0025 (10)(12) = 0.3 in2/ft
Use #5 bars at 12" O.C
Design flexural reinforcement:
Calculate factored moment at base:
Mu = 1.4 [(100)(60)+(75)(45)+(50)(30)+(25)(15)]=15750 ft-kip
Tension control section,

= 0.9

Factor: Rn = (15750)(12000)/[0.9(10)(14.4x12) 2] = 703 psi, and m = fy/(0.85fc')=17.7


Reinforcement ratio, = (1/m)[1-(1- 2 m Rn/fy)] = 0.013
Area of reinforcement, As = 0.013 h d = 22.9 in2.
Use #10 bars, number of bars, n = 22.9/1.27 = 18
Check effective depth
Concrete cover = 2" for exterior wall. Use 3" spacing between #10 bars in two layers
Effective depth, d = (18)(12) - 2-(3)(8)/2 =202 in
Recalculate reinforcement, Factored Rn = Mu / h d2 = 514.7 psi, m = 17.
Reinforcement ratio,

= 0.0094

Area of reinforcement, As = 18.9 in2.


Use #10 bars, number of bars, n = 18.9 /1.27 = 15, Use 16 # 10
Use #4 closed shape ties to enclose tension reinforcement,
Area of reinforcement for shear As = 0.4 in2.
Check clear spacing between bars, S = 10-(2)(2)-(0.5)(2)-1.27 = 3.73 in O.K.