0% found this document useful (0 votes)
629 views

PNID

This document is a piping and instrumentation diagram for the HP1 compressor train and suction scrubber on a gas production facility. It details the piping connections and instrumentation for components including the centrifugal compressor, suction scrubber, strainers, control and safety valves. Key specifications are provided for the compressor and scrubber such as flow rates, power requirement, materials and dimensions. Notes provide additional information on component interfaces, insulation, straight pipe lengths and control system interfaces.

Uploaded by

amitrai86
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
629 views

PNID

This document is a piping and instrumentation diagram for the HP1 compressor train and suction scrubber on a gas production facility. It details the piping connections and instrumentation for components including the centrifugal compressor, suction scrubber, strainers, control and safety valves. Key specifications are provided for the compressor and scrubber such as flow rates, power requirement, materials and dimensions. Notes provide additional information on component interfaces, insulation, straight pipe lengths and control system interfaces.

Uploaded by

amitrai86
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

P

S
S

P
S
S

13VB31-1273
D
FB
LC

LL =550mm

LT
31171B

2"

TO VZ 3105 B

2"

EL : 42025 mm

LS
31171B

HH =1300mm

03

NOTE 9

18"-HG -1331-109-F49

SS072A

L2

L1

G1

F49

F49

B23F

L3

L4

03

03

03

03

03

FC
TSO

HOLD 2

03

PACKAGE TYPE

WORKING SUCT.FLOW RATE (Sm 3/hr)


DESIGN SUCT.FLOW RATE (Sm3/hr)
POWER (kW)
MATERIAL (CASING / INTERNAL)

191667
191667
8290
CS/SS
P3

40 / 135

170 / -29

03

3/4"
D

13VT31-0115

HP1 COMPRESSOR-TRAIN B
CENTRIFUGAL
DESIGN
FV/120
WORKING (SUCT./DICH.)
26.7 / 76

P
S
S

P
S
S

13VB31-1271

NOTE 10

13VB31-1270

F49

B23F

TO SP
3104B
P2
G49

F49

03

03

LL=16barg

03

HH=41barg

S/N
1

03

PS
31180B

TYPE
STRAINER

900#

NOTE 21 14"

3104B
624

SHT 25 03

31180B

PT

HH=2bar
1D MIN.
PDT
PDI H
31179B
31179B

16"x8"

F49

31178B

* PT

10" 03

3104B
625
NOTE 21

SHT 25

PT
31181B

TT
31182B

PROJECT TAG NO.


TO SP 3104B P2

D
FB

13VB36-1259

03

LL =47barg

03

HH =98barg

P
S
S

P
S
S

P
S
S

03 EL : 41820 mm

PS
31181B

FO
TSO
FB

1
ESD

HH =160

HOLD 6

V
3/4"

31186B

BDV

TYPE 7P

13VB31-1261

2"

2"X1"

G70

03

F06

03

3"X1 1/2"

HOLD 6

LO
FB

13VT31-0116
1 1/2"

MIN.

2"X1 1/2"
13VD31-0208
F49

600 MIN.

13VB31-1266 SDV
31189B
2"

TYPE 2B

FC

UCP

2"

SDV
31191B

RO
31192B

03

HOLD 6

PDS
31190B

HEADER

NG-EGN-13-KSEC-118566

HEADER

WARM HP FLARE

TO

NG-EGN-13-KSEC-118566

HEADER

WARM HP FLARE

TO

NG-EGN-13-KSEC-118566

HEADER

WARM HP FLARE

TO

NG-EGN-13-KSEC-118566

HEADER

WARM HP FLARE

TO

NG-EGN-13-KSEC-118566

03
3" - CD - 1328 - 043 - F06

TO

03

NG-EGN-13-KSEC-118729

HEADER

CLOSED DRAINS

TO

NG-EGN-13-KSEC-118438

INLET MANIFOLD

1st STAGE SEPARATORS

TO

NG-EGN-13-KSEC-118498

INLET COOLER - TRAIN B

GLYCOL CONTACTOR

HH = 2bar

NOTE 14

2" - HL - 1331 - 044 - F49

4"X2"

3-31-02B 4"
PSS

FC 600
FB MIN

UCP

TO
WARM HP FLARE

16"-HG-1331-116-G70-A

13VB31-1268

NOTE 17

3-31-02B
PSS

03

10"-FH-1336-129-B23F

D
3/4"
13VB31-1267
PDT
31190B

TYPE 2B

MIN

NOTE 17

NOTE 1

18"-FH -1336-130-B23F

18"-FH-1336-131-B23F

12"-FH-1336-525-B23F

03

12"-FH-1336-133-B23F

SS066

SS073B

03 TO SP
315022

HOLD 6

13VD31-0207 1m
MIN

NOTE 17

H49
G70

1" 6"X1"
03
G70 B23F

B23F

600 MIN.

31187B 03
10"X4" 13VB31-1264

RO

FB
NC
UCP
NOTE 15

03

13VT31
-0719

6"-FH-1336-370-B23F

LC 13VB31-1260
FB 12"-HG-1331-232-G70-P

LO
18"X6"
FB 300#
03
12"X4"
LC
13VB31-1262
FB

13VB36-1263

110
31188B 4P6

BLOCKED OUTLET

NOTE 19, 20 PSV2

LO13VB31-1258
FB
B23F
G70
LO
FB
03
13VB31-1256

12"X4"

LO 300# 18"X6"
FB

GE TAG NO.
TO VF 3104B-19

OD1

13VB31-1274 2"

03

NOTE 3,4,23

BLOCKED OUTLET

TS
31182B

16"X10"

03

TT
31185B

PG
31183B

03

3/4"

B23F
G70

TO KA 3105 B

14"-HG-1331-115-H49-A
ANTISURGE LINE

PSV1 110
31188B 4P6
NOTE 19, 20

5D
MIN
NOTE 15

03

14"x8"

FV
31176B

13VB31-1257

03
H49

FO
TSO

PT
31184B

5D
MIN
NOTE 15
F49

NOTE 11

G49

13VB31-1253

12"X6"
LO
FB
8"X4" 03

13VB36-1255

03
NOTE 20

03

3/4"
LC
FB

60
PSV2
4L6 31175B

13VB31-1254

03

BACKFLOW

20"-HG-1331-111-F49-A

SS073A

LV
31173B

HOLD 6

TO KA 3105 B

13VB31-1272

2"

13VB31-1269

03

8"-HG-1331-233-F49

LO
FB

LO
12"X6"
FB
8"X4" 03

13VB36-1252

NOTE 20

HOLD 6

03

RATI

ON

NG-EGN-13-KSEC-118496

03

DE
1

31
A1

PID

EGINA FPSO - TOPSIDE


HP1 COMPRESSOR & SUCTION SCRUBBER - TRAIN B
PIPING AND INSTRUMENTATION DIAGRAM

R PO

T I ONAL P E
NA
T

CO

TOTAL UPSTREAM NIGERIA LIMITED

03

03
1 - DELETED.
2 - CONTROL VALVE SIZES PENDING VENDOR DATA.
3 - 5 DELETED. 03
6 - EXTENT OF ACOUSTIC INSULATION ON GAS LINE TO BE CONFIRMED.
7 - DELETED.
8 - DELETED.
9 - 14 DELETED. 03
15 - FLOWMETER STRAIGHT LENGTH REQUIREMENT TO BE CONFIRMED BY VENDOR.
16 - DELETED.
17 - DELETED. 03

03

PRO
NONE

KA

1 - TWO DISSIMILAR CHECK VALVES TO MINIMISE REVERSE FLOW. ONE TO BE NON-SLAM TYPE.
2 - DELETED.
3 - MP AND HP1 COMPRESSORS ARE IN THE SAME CASING.
4 - MP, HP1 AND HP2 COMPRESSORS ON EACH TRAIN ARE DRIVEN BY A COMMON GAS TURBINE.
5 - 8 DELETED.
10 - SCRUBBER LEVEL GAUGE LG-31172B TO BE VISIBLE FROM LV-31173B BY-PASS GLOBE VALVE.
11 - TEMPORARY STRAINER FOR START-UP. SPOOL TO BE REMOVED AFTER START-UP. TEMPORARY FILTER
TO BE INSTALLED AS CLOSE AS POSSIBLE TO COMPRESSOR SUCTION BUT NOT LESS THAN 6
TIMES INLET FLANGE DIAMETER. FILTER SHALL BE MOUNTED IN HORIZONTAL POSITION.
12 - 13 DELETED.
14 - HIGH DIFFERENTIAL PRESSURE SHALL INHIBIT OPENING OF MAIN SDV.
15 - STRAIGHT LENGTH (IN PIPE DIAMETERS) TO BE WITHOUT REDUCTION.
16 - DELETED. 03
17 - CONNECTION TO BE ON TOP OF PIPE.
18 - DELETED. 03
19 - PSV TO BE NON-FLOWING, MODULATING PILOT TYPE.
20 - PILOT SENSING LINES SHALL BE ELECTRICALLY HEAT TRACED.
03
21 - COMPANION FLANGES TO BE SUPPLIED BY COMPRESSOR VENDOR.
22 - PIPING HIGH POINT VENT AND LOW POINT DRAIN LOCATIONS SHALL BE PROVIDED BY PIPING LAYOUT.
23 - REFER TO REFERENCE DRAWING NO.2,3 FOR TURBO COMPRESSOR PACKAGE INTERFACE.
24 - ANTI-SURGE CONTROL IS PART OF COMPRESSOR PACKAGE. FOR DETAILS INSIDE LOGIC, REFER TO
VENDOR'S CONTROL SYSTEM AND FUNCTIONAL DESCRIPTION (NG-EGN-13-GCEC-170002) AND DRAWING
(NG-EGN-13-GCEC-118001).

E UM

TEMPERATURE DESIGN (MAX./MIN.)


(C)
WORKING (SUCT./DICH.)

ITEM NUMBER
SERVICE
TYPE
PRESSURE
(bar g)

TYPE 3

SP
31001B

13VD31-0205 BOTTOM OF PIPE

03

P
S
S

13VD31-0204
UC
2"
13VB31-1276

03

LIC
31173B L

GAP CONTROL

PG
31174B

LT
31173B

SP

SDV
31194B TYPE 2D

G2

M
24"

F49

3/4"

13VB31-1249

13VB31-1250

7D MIN.

G49 G49

14D MIN.

NOTE 10

LG
31172B

03

BACKFLOW

FE
PDT HOLD 15* TT
*31176B
* 31176B
31177B

NOTE 24

PACKAGE TYPE : P3

2"
13VB31-1275

SS063B

HP1 COMPRESSOR SUCTION SCRUBBER


DESIGN
FV/ 60
03
WORKING
25.8
TEMPERATURE DESIGN (MAX./ MIN.)
170 / -29
(C)
WORKING
40
INTERNAL DIAMETER (mm)
1600
HEIGHT (TL/TL) (mm)
3750
MATERIAL
CS
CORROSION ALLOWANCE (mm)
0
LINING/CLADDING TYPE
N / SS 316L
INSULATION TYPE/THICKNESS (mm)
N/A
TRIM
HG-1331-425-F49

ITEM NUMBER
SERVICE
PRESSURE
(bar g)

03

NG-EGN-13-KSEC-118494

SUCTION COOLER

HP1 COMPRESSOR

FROM

NG-EGN-13-KSEC-118494

3-31-02B

3-31-07B

60
PSV1
4L6 31175B

8"-HG-1331-110-F49

SUCTION COOLER TRAIN B

FC

SS073B

3-31-02B 3-31-02B

1D MIN.

20"X14"

16"-HG-1331-107-F49-A

MIN.

3D MIN.

HP1 COMPRESSOR

3-31-07B

A
SP

4"-HG-1331-114-G70-P

SS063B

STRAIGHT
LENGTH

P
12"-HG-1331-113-G70-P

TO

2" -HL-1331-111-F49

3-31-02B 3-31-02B 3-31-02B

03
1 - ALL ITEMS DESIGNATED WITH * ARE LOOSE SUPPLIED BY COMPRESSOR VENDOR,
TO BE INSTALLED AT SITE BY CONTRACTOR.
2 - WHERE CS FLANGES ARE MATED WITH SS/CRA FLANGES, CS FLANGE TO HAVE
SS316L OVERLAY ON FACE.

IA

N I GER

03

L