MM AQUA TECH. LTD.

M M AQUA TECHNOLOGIES LIMITED, CHENNAI


CLIENT: FLAMEMAX ENGG.
Design Sheet for Tube Settler Clarifier:
DATE 13-07-2015
Flow rate
cu.m/d
12000
cu.m/hr
500.00
Number of Clarifier/Settler
Nos
2
Design flow per clarifier
cu.m/hr
500.00
Vertical ht. Of TS
m
1.00
Shape
MMATL Make Hex.-Chevron
Cross section size
mm X mm
120 X 44
Settling area
sq.m/cu.m
11
Angle of inclination
degrees
55
Settling velocity
m/hr
0.55
0.6
Factor of safety
Plan area reqd.
sq.m
1515.15
Vol. Of TUBEDEK/clarifier
cu.m
137.74
Area of TUBEDEK
sq.m
137.74
SLR
cu.m/sq.m-hr
3.63
Design SLR
cu.m/sq.m-hr
4.00
Area of TUBEDEK required
sq.m
125.00
Dim. Of TUBEDEK
mXm
12.00 X 10.42
Angle correction
m
0.70 SAY 0.7
Inlet chamber
m
0.6
Tank dimension
mXm
12.00 X 11.72
Actual Tube plan area
sq.m
125.00
Actual Tube volume
cu.m
125.00
SLR at design flow
cu.m/sq.m-hr
4.00
Water above T.S.
m
0.50
Water below T.S.
m
1.00
Side water depth
m
2.50
Free board
m
0.30
2.80
Tank depth(excl. hopper)
m
12 X 11.7166666666667 X 2.8
Tank Dimension
mXmXm
1
No. of Hoppers
Bottom slope
degrees
45
Hopper depth
m
5.61
Tank Depth(total)
m
8.41
TUBEdek volume
cu.m
125.00