0% found this document useful (0 votes)
135 views

Cell Reselection:: C2 C1+CRO-TO H (PT-T) When PT Is Not Equal To 31: C2 C1-CRO When PT Is Equal To 31

Cell reselection is the process by which a mobile station tunes to a new cell. For cells within the same location area, if the target cell's C2 value is higher than the serving cell's for over 5 seconds, reselection occurs. For different location areas, the target C2 must exceed the serving C2 by at least the CRH value and last 5+ seconds. Cell reselections from C2 comparisons have a minimum 15 second interval. Reselection also occurs if the serving cell is prohibited, the downlink fails, or C1 is below 0 for 5+ seconds. C2 is calculated using C1, CRO, TO, PT, and other parameters.

Uploaded by

Syed Yawer Imam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views

Cell Reselection:: C2 C1+CRO-TO H (PT-T) When PT Is Not Equal To 31: C2 C1-CRO When PT Is Equal To 31

Cell reselection is the process by which a mobile station tunes to a new cell. For cells within the same location area, if the target cell's C2 value is higher than the serving cell's for over 5 seconds, reselection occurs. For different location areas, the target C2 must exceed the serving C2 by at least the CRH value and last 5+ seconds. Cell reselections from C2 comparisons have a minimum 15 second interval. Reselection also occurs if the serving cell is prohibited, the downlink fails, or C1 is below 0 for 5+ seconds. C2 is calculated using C1, CRO, TO, PT, and other parameters.

Uploaded by

Syed Yawer Imam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

Cell Reselection:

Cell reselection for cells in same location area


If the C2 value of the target cell is higher than that of the serving cell and
last for longer than 5 seconds, a cell reselection process will be performed
and the MS tunes to the new cell.
Cell reselection for cells in different location areas
If the C2 value of the target cell is higher than that of the serving cell by at
least the value of CRH and last for longer than 5 seconds, a location
updating process and the cell reselection process will be performed.
Cell reselections caused by C2 have a time interval of 15 seconds
If current serving cell is prohibited, or down link fails or C1 is less than 0
continuously for 5s, cell reselection will also be triggered.
C2=C1+CRO-TO*H (PT-T) When PT is not equal to 31:
C2=C1-CRO When PT is equal to 31.
Wherein:
1. Function H(x) =0, when x<0; H(x) =1, when x>0.
2. T is a timer with initial value 0. When a certain cell becomes of one of the six neighbor
cells with highest signal level, T corresponding to this cell begins to count with accuracy
of one TDMA frame (about 4.62ms). When it is out of the six strongest neighbor cells,
the corresponding timer is reset.
3. CRO is used for manually correct the cell reselection parameter C2.
4. The function of TO is to reduce the value of C2 from the time when timer begins to
count to the time when the value of timer reaches the stipulated PENALTY_TIME.
5. PT is the time TO acts on C2. But PT=31 is reserved as the symbol to change the
CROs effect on C2.
CRO
Value range: 0~63, the corresponding level value: 0~126dB, stepped every 2dB.
Unit: None
Content: Cell Reselect Offset. It is a parameter in C2 calculation to give a manual
modification in MS cell reselection.
Recommendation: 0
TO
Value range: 0~7 , the corresponding value is 0~60dB, 7 corresponds to Infinite
Unit: None
Content: Cell Reselect Temporary Offset. It is a parameter in C2 criterion to give
a temporary modification within PT time.
Recommendation: 0

PT
Value range: 0~31, the corresponding time is 20~620s. 31 is to change the
function direction of CRO on C2.
Unit: None
Content: Cell Reselect Penalty Time.
Recommendation: 0
CRH
Value range: 0~14 , the step size is 2
Unit: dB
Content: Cell Reselection Hysteresis. It is the parameter used when cell
reselection happens between two location areas.
Recommendation: 4

You might also like