Cooling Jacket of CSTR: For Process Fluid
Cooling Jacket of CSTR: For Process Fluid
NRe = D2N /
= (0.75)27560/13.553
= 1.517105 (so turbulent flow)
Npr = Cp/k
= 2.52073.7610-3 1000/ 0.201
= 47.15
Agitator blade turbine with no baffles
Nu = 0.68 (NRe) 0.67 (Npr) 0.33 (/w) 0.14
Nu = 8757.45 w/m.0c
hi = 862.86 w/m. 0c
Cold Fluid
Viscosity = 0.000875 kg/m.sec
Thermal Conductivity = 0.6191 w/m. 0c
Specific heat, Cp = 4.18 kJ/kg.0c
Density, = 1000 kg/m3
NRe = De V /
D e = (Do2 D12)/Di
D e = 0.311 m
Jacket Cross sectional area, A = Do2 D12)/4
A = 0.498 m2
V = Q/A
Q = 2.5 x 10-5 m3/sec
V = 2.5 x 10-5/ 0.498
V = 5.03 x 10-5 m/sec
NRe = De V /
NRe = 17.87 (Laminar flow)
Pr = Cp /k
Pr = 4.18 x 1000 x (0.000875)/0.6191
Pr = 5.90
Jacket type is Annular with spiral baffling
Nu = 1.86 (NRe)(N Pr) (De/L)0.33(/w) 0.14
Nu = 56
h0 = 111.4 w/m2.0c
1 1 1
= +
U hi ho
1
1
1
=
+
U 862.86 111.4
1
=98.727
U
w/ m2 0c
Deviation
Causes
Consequences
No
Flow
More
Flow